• 제목/요약/키워드: QRS Detection

검색결과 101건 처리시간 0.026초

An SPC-Based Forward-Backward Algorithm for Arrhythmic Beat Detection and Classification

  • Jiang, Bernard C.;Yang, Wen-Hung;Yang, Chi-Yu
    • Industrial Engineering and Management Systems
    • /
    • 제12권4호
    • /
    • pp.380-388
    • /
    • 2013
  • Large variation in electrocardiogram (ECG) waveforms continues to present challenges in defining R-wave locations in ECG signals. This research presents a procedure to extract the R-wave locations by forward-backward (FB) algorithm and classify the arrhythmic beat conditions by using RR intervals. The FB algorithm shows forward and backward searching rules from QRS onset and eliminates lower-amplitude signals near the baseline using a statistical process control concept. The proposed algorithm was trained the optimal parameters by using MIT-BIH arrhythmia database (MITDB), and it was verified by actual Holter ECG signals from a local hospital. The signals are classified into normal (N) and three arrhythmia beat types including premature ventricular contraction (PVC), ventricular flutter/fibrillation (VF), and second-degree heart block (BII) beat. This work produces 98.54% accuracy in the detection of R-wave location; 98.68% for N beats; 91.17% for PVC beats; and 87.2% for VF beats in the collected Holter ECG signals, and the results are better than what are reported in literature.

Fully Analog ECG Baseline Wander Tracking and Removal Circuitry using HPF Based R-peak Detection and Quadratic Interpolation

  • Nazari, Masoud;Rajeoni, Alireza Bagheri;Lee, Kye-Shin
    • Journal of Multimedia Information System
    • /
    • 제7권3호
    • /
    • pp.231-238
    • /
    • 2020
  • This work presents a fully analog baseline wander tracking and removal circuitry using high-pass filter (HPF) based R-peak detection and quadratic interpolation that does not require digital post processing, thus suitable for compact and low power long-term ECG monitoring devices. The proposed method can effectively track and remove baseline wander in ECG waveforms corrupted by various motion artifacts, whereas minimizing the loss of essential features including the QRS-Complex. The key component for tracking the baseline wander is down sampling the moving average of the corrupted ECG waveform followed by quadratic interpolation, where the R-peak samples that distort the baseline tracking are excluded from the moving average by using a HPF based approach. The proposed circuit is designed using CMOS 0.18-㎛ technology (1.8V supply) with power consumption of 19.1 ㎼ and estimated area of 15.5 ㎟ using a 4th order HPF and quadratic interpolation. Results show SNR improvement of 10 dB after removing the baseline wander from the corrupted ECG waveform.

유비쿼터스 헬스케어 시스템을 위한 노드기반의 R피크 검출 알고리즘 (R-peak Detection Algorithm in Wireless Sensor Node for Ubiquitous Healthcare Application)

  • 이대석;황기현;차경환
    • 한국정보통신학회논문지
    • /
    • 제15권1호
    • /
    • pp.227-232
    • /
    • 2011
  • 현재 무선센서노드 기반의 헬스케어 모니터링 시스템이 활발히 연구되고 있다. 하지만 생체신호의 모니터링을 위한 전체 데이터의 전달은 무선센서네트워크 내의 데이터 트래픽과 에너지 소모가 증가하게 된다. 본 연구에서는 경량의 전처리 과정 및 알고리즘을 통해 ECG신호에서 의미있는 파라미터만을 검출하여 전송하였다. 본 연구에서는 정상적인 ECG에서 무선센서노드에서 R피크, RR간격을 검출할 수 있는 TinyOS 기반 어플리케이션을 구현하였으며 결과로 dECG, R피크, RR간격, HRV를 그래프로 확인 할 수 있었다. 따라서 본 연구를 이용하면 ECG신호 전체 데이터가 아닌 주요 정보만을 보냄으로서 에너지 소모, 데이터량을 줄일 수 있다.

심전도 신호 처리를 위한 기저함수 추출에 관한 연구 (A Study on the Extraction of Basis Functions for ECG Signal Processing)

  • 박광리;이전;이병채;정기삼;윤형로;이경중
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제53권4호
    • /
    • pp.293-299
    • /
    • 2004
  • This paper is about the extraction of basis function for ECG signal processing. In the first step, it is assumed that ECG signal consists of linearly mixed independent source signals. 12 channel ECG signals, which were sampled at 600sps, were used and the basis function, which can separate and detect source signals - QRS complex, P and T waves, - was found by applying the fast fixed point algorithm, which is one of learning algorithms in independent component analysis(ICA). The possibilities of significant point detection and classification of normal and abnormal ECG, using the basis function, were suggested. Finally, the proposed method showed that it could overcome the difficulty in separating specific frequency in ECG signal processing by wavelet transform. And, it was found that independent component analysis(ICA) could be applied to ECG signal processing for detection of significant points and classification of abnormal beats.

고해상도 심전계의 개발 (Development of a High-Resolution Electrocardiography)

  • 이호성;우응제;박승훈;이종민;박광석
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1996년도 춘계학술대회
    • /
    • pp.179-183
    • /
    • 1996
  • Most of the conventional electrocardiogaphies fail to detect signals other than P-QRS-T due to the limited SNR and bandwidth. High-resolution electrocardiography (HRECG) provides better SNR and wider bandwidth for the detection of micro-potentials with higher frequency components such as ventricual late potentials(LP). In this paper, we developed a HRECG using uncorrected XYZ lead. The overall gain of the amplifier is 4000 and the bandwidth is $0.5{\sim}300Hz$ without using 60Hz notch filter. Three 16-bit AH converters sample X, Y, and Z signals simultaneously with a sampling frequency of 2000Hz. Sampled data are transmitted to PC via a DMA-controlled serial communication channel using RS-485 and HDLC protocol. The noise level of the developed HRECG is less than $5{\mu}V_{rms,\;RTI}$. In order to further reduce the noise level, signal averaging technique is implemented utilizing template matching method. The SNR of the developed HRECG is high enough for the detection of LP.

  • PDF

부정맥 분류를 위한 ECG 신호의 파형검출 알고리즘 (Detection of ECG Signal Waveform for Arrhythmia Classification)

  • 민철홍;김태선
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.453-456
    • /
    • 2005
  • 일반적으로 심전도는 심장계통의 질환을 판단할 때 사용된다. 이러한 심장질환의 이상 유무를 자동으로 진단하기 위해서는 QRS파형 검출을 필요로 하며, 이를 위하여 웨이블렛변환 방법이나 템플릿매칭, 룰 베이스 방법 등 여러 가지 방법들이 쓰이고 있으나, 심전도 신호가 표준화된 형태를 갖지 않는 경우는 검출 능력에 많은 한계를 갖고 있다. 본 논문은 파형의 베이스라인(baseline)을 기준으로 진폭 값에 절대치을 취하는 방법으로 파형의 R피크값을 검출하는 알고리즘을 제안한다. 결과를 검증하기 위해 MIT-BIH 데이타베이스에서 제공하는 데이터와 R피크값을 본 논문의 알고리즘으로 추출된 R피크값과 비교한 결과 96.7%의 검출률을 보였다.

  • PDF

Flash Memory Card를 이용한 Intelligent Ambulatory Monitoring 시스템 설계 (Design of an Intelligent Ambulatory Monitoring System Using Flash Memory Card)

  • 송근국;이경중;윤형로
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 춘계학술대회
    • /
    • pp.330-333
    • /
    • 1997
  • In this paper, we designed a low power and small-sized, light weighted intelligent ambulatory monitoring system using a flash memory card. The system's hardware specifications are as follows: 2 channels, 8bit/250Hz sampling rate, 20M byte storage capacity, a single-chip microcontroller (68HC11E9). To easily interface with PC based system, FFS(Flash File System) was used. We obtained the QRS detection rate of 99.14 through the evaluation with MIT/BIH database.

  • PDF

ECG 신호의 분산처리를 위한 Preprocess Module에 관한 연구 (A Design of the Preprocess Module for the Distributed Process of the ECG signals)

  • 송향봉;이경중;윤형로;이명호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 전기.전자공학 학술대회 논문집(II)
    • /
    • pp.1338-1340
    • /
    • 1987
  • This paper describes the design of ECG data preprocess module for the ECG signals. This module process the data obtained from two channels. It is composed of the AID converter, QRS detector, one chip micro-computer and memory. This module performs the following functions;digital filtering, R wave detection and determination of reference point for the ST segment. The measured points are transfered to the next data module by the interrupt process. This preprocessor data module is available to the basis for the parallel data processing for the real time automatic diagnosis.

  • PDF

웨이블릿 알고리즘을 적용한 휴대용 텔레미트리 시스템 (Implementation of a portable telemetry system based on wavelet transform.)

  • 박차훈;서희돈
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 하계종합학술대회 논문집(5)
    • /
    • pp.113-116
    • /
    • 2000
  • In this paper presents the portable wireless ECG data detection and diagnosis system based on discreet wavelet transform. An algorithm based on wavelet transform suitable for real time implementation has been developed in order to detect ECG characteristics. In particular, QRS complex, S and T waves may be distinguished form noise, baseline drift or artifacts. Proposed telemetry system that a transmitting media using radio frequency(RF) for the middle range measurement of the physiological signals and receiving media using optical for electromagnetic interference problem. A standard hi-directional serial communication interface between the telemetry system and a personal computer or laptop, allows read-time controlling, diagnosing and monitoring of system. A portable telemetry system within a size. of 65${\times}$125${\times}$45mm consists of three parts: a digital signal processing part for physiological signal detect or diagnose, RF transmitter for data transfer and a optical receiver for command receive. Advantages of proposed telemetry system is wireless middle range(50m) FM transmission, reduce electromagnetic interference to a minimum. which enables a comfortable diagnosis system at home.

  • PDF

광용적맥파 신호 최대 dV/dt 검출 알고리즘 개발 (Maximum dV/dt Detection Alaorithm for Photoplethysmography Waveform)

  • 신항식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.1395-1396
    • /
    • 2015
  • 본 연구의 목적은 광용적맥파 해석에 중요하게 사용되는 최대 상승기울기(maximum dV/dt) 지점 검출 알고리즘 개발로, 미분 및 필터링을 통한 전처리 과정, 극점 검출과정, 역탐색 등의 후처리 과정으로 구성되는 알고리즘을 구현하였다. 제안된 알고리즘의 성능을 평가하기 위하여 총 74,225개의 맥박파형을 사용한 검증을 수행하였으며, 동시에 측정된 심전도 QRS지점을 기준으로 최대 dV/dt 측정 위치 정확성을 판정하였다. 시뮬레이션 결과, 적응형 임계치 극점 검출 방법과 함께 사용하였을 때, 제안된 알고리즘은 기존 광용적맥파 상단, 하단극점 검출 알고리즘과 유사한 성능인 98.57%, 99.98%의 민감도와 특이도, 0.02%의 오검출율을 가지는 것으로 나타났다.

  • PDF