• Title/Summary/Keyword: QD)

Search Result 239, Processing Time 0.025 seconds

Rapid detection of the hepatitis a virus from fresh lettuce using immunomagnetic separation and quantum dots assay (IMS-QD assay를 활용한 상추에서 간염 A형 바이러스의 신속순수분리 및 형광 검출법 연구)

  • Lee, Hee-Min;Kwon, Joseph;Choi, Jong-Soon;Won, Yong-Gwan;Kim, Eun-Sun;Chung, Jae-Keun;Kim, Min-Ji;Kim, Duwoon
    • Food Science and Preservation
    • /
    • v.21 no.2
    • /
    • pp.170-174
    • /
    • 2014
  • Hepatitis A virus (HAV) infection leads to acute liver failure and death through the intake of contaminated food. The polymerase chain reaction (PCR) has been used to detect HAV in food samples. HAV detection takes a long time, however, due to the virus concentration step required before PCR assay. In this study, a rapid method of detecting the HAVs present in lettuce using immunomagnetic separation combined with quantum dots (IMS-QDs) assay was developed. The detection limit of IMS-QDs for HAV was 10 $TCID_{50}/mL$, similar to the result that was obtained using RT-PCR combined with PEG or IMS. The application of IMS-QDs assay completed the viral detection within one hour, but this was not possible using PEG combined with RT-PCR. In conclusion, IMS-QDs assay is a rapid and efficient method for detecting HAV at a low concentration in agricultural products.

Syntheses and Properties of ZnS:Mn/ZnS Core-Shell Quantum Dots Prepared via Thermal Decomposition Reactions of Organometallic Precursors at Various Reaction Temperatures (다양한 온도 조건에서의 ZnS:Mn/ZnS 코어-쉘 양자점의 합성 및 광 특성에 관한 연구)

  • Lee, Jae-Woog;Hwang, Cheong-Soo
    • Journal of the Korean Chemical Society
    • /
    • v.53 no.6
    • /
    • pp.677-682
    • /
    • 2009
  • ZnS:Mn/ZnS core-shell quantum dots (QDs), were synthesized via a thermal decomposition reaction of organometallic precursors in a hot solvent mixture. The synthetic conditions of the quantum dots were monitored at various reaction temperatures for the core formation, while the shell formation temperature was fixed at 135$^{\circ}C$. The obtained colloidal nanocrystals at corresponding temperatures were characterized by UV-Vis, solution photoluminescence (PL) spectroscopies, and further obtained powders were characterized by XRD, HR-TEM, and EDXS analyses. The synthetic temperature condition to obtain the best PL emission intensity for the core-shell QD was 135$^{\circ}C$, for both core and shell formation. At this temperature, solution PL spectrum showed a narrow emission peak at 583 nm with a relative PL quantum efficiency of 42.15%. In addition, the measured spherical particle sizes for the ZnS:Mn/ZnS nanocrystals via HR-TEM were in the range of 4.0 to 5.4 nm, while ellipsoidal particles were obtained at 150$^{\circ}C$.

Study of Multi-stacked InAs Quantum Dot Infrared Photodetectors Grown by Metal Organic Chemical Vapor Deposition (유기금속화학기상증착법을 이용한 적층 InAs 양자점 적외선 수광소자 성장 및 특성 평가 연구)

  • Kim, Jung-Sub;Ha, Seung-Kyu;Yang, Chang-Jae;Lee, Jae-Yel;Park, Se-Hun;Choi, Won-Jun;Yoon, Eui-Joon
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.3
    • /
    • pp.217-223
    • /
    • 2010
  • We grew multi-stacked InAs/$In_{0.1}Ga_{0.9}As$ DWELL (dot-in-a-well) structure by metal organic chemical vapor deposition and investigated optical properties by photoluminescence and I-V characteristics by dark current measurement. When stacking InAs quantum dots (QDs) with same growth parameter, the size and density of QDs were changed, resulting in the bimodal emission peak. By decreasing the flow rate of TMIn, we achieved the uniform multi-stacked QD structure which had the single emission peak and high PL intensity. As the growth temperature of n-type GaAs top contact layer (TCL) is above $600^{\circ}C$, the PL intensity severely decreased and dark current level increased. At bias of 0.5 V, the activation energy for temperature dependence of dark current decreased from 106 meV to 48 meV with increasing the growth temperature of n-type GaAs TCL from 580 to $650^{\circ}C$. This suggest that the thermal escape of bounded electrons and non-radiative transition become dominant due to the thermal inter-diffusion at the interface between InAs QDs and $In_{0.1}Ga_{0.9}As$ well layer.

Preparation of Chitosan-Gold and Chitosan-Silver Nanodrug Carrier Using QDs (QDs를 이용한 키토산-골드와 키토산-실버 나노약물전달체 제조)

  • Lee, Yong-Choon;Kang, Ik-Joong
    • Korean Chemical Engineering Research
    • /
    • v.54 no.2
    • /
    • pp.200-205
    • /
    • 2016
  • A drug transport carrier could be used for safe send of drugs to the affected region in a human body. The chitosan is adequate for the drug delivery carrier because of adaptable to living body. The gold, a metallic nanoparticles, tends to form a nano complex at rapidly when it combined with chitosan because of its negative charge. having energy from the other, outer gold nano-complex make heat due to its property to release the contained drugs to the target area. Silver could be also formed an useful biocompatible nano-composites with chitosan which should be used as an useful drug transfer carrier because its special ability to protect microbial contamination. Being one of the oxidized nano metals, $Fe_3O_4$ is nontoxic and has been used for its magnetic characteristics. In this study, the control of catalyst, reducing agent, and solvent amount. The chitosan-$Fe_3O_4$-gold & silver nanoshell have been changed to form about 100 nm size by ionic bond between the amine group, an end group of chitosan, and the metal. It was observed the change in order to seek for its optimum reaction condition as a drug transfer carrier.

Analysis of Human Serum Amyloid A-1 Concentrations Using a Lateral Flow Immunoassay with CdSe/ZnS Quantum Dots (Human Serum Amyloid A-1 단백질 농도 분석을 위한 CdSe/ZnS 양자점 기반의 Lateral Flow Immunoassay 방법 개발)

  • Fajri, Aidil;Goh, Eunseo;Lee, Sanghyuk;Lee, Hye Jin
    • Applied Chemistry for Engineering
    • /
    • v.30 no.4
    • /
    • pp.429-434
    • /
    • 2019
  • A lateral flow immunoassay platform utilizing antibody functionalized water soluble CdSe/ZnS semiconductor quantum dots (QDs) was developed for the analysis of human serum amyloid A-1 (hSAA1) in a buffer solution. hSAA1 was chosen as a target protein because it is regarded as a potential biomarker associated with early diagnosis and prognosis in patients of lung cancer. The immunoassay strip on a nitrocellulose membrane was fabricated by spraying two lines composed of a test line with a monoclonal antibody against hSAA1 (10G1) (anti hSAA1) and a control line of anti-chicken IgY. While the CdSe/ZnS QDs synthesized in an organic phase were transferred to a water phase by ligand exchange using carboxylic acid modified alkane thiol. The QDs was then conjugated to monoclonal antibody against hSAA1 (14F8) [anti hSAA1 (14F8)] and used as a fluorescent detection probe. The sequential lateral flow of hSAA1 in different concentration and QDs-anti hSAA1 (14F8) complex allowed to form the surface sandwich complex of anti hSAA1 (10G1)/hSAA1/QD-anti hSAA1 (14F8), which was then analyzed using fluorescence microscope. A 100 nM concentration of hSAA1 protein can be detected by naked eyes under an optimized lateral flow buffer condition with a sensing time of 5 mins.

Monoclonal Antibody against leucocyte CD11b(MAb 1B6) increase the early mortality rate in Spraque Dawley with E. coli pneumonia (백혈구 CD11b에 대한 단 클론 항체 (MAb 1B6)는 Spraque Dawley의 E. coli 폐렴의 조기 사망률을 증가시킨다)

  • Kim, Hyung Jung;Kim, Sung Kyu;Lee, Won Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.4
    • /
    • pp.579-589
    • /
    • 1996
  • Background : Activation of neutrophil is critical for the clearance of microorganisms and toxic host mediators during sepsis. Unfortunately the activated neutrophil and its toxic byproducts can produce tissue injury and organ dysfunction. The leucocyte CD11/18 adhesion complex regulates neutrophil-endothelial cell adhesion, the first step in neutrophil migration to sites of injection and inflammation. To investigate the potential of neutrophil inhibition as a treatment strategy for sepsis, we evaluated the effects of monoclonal antibody against CD11b (MAb 1B6) in rats intrabronchial challenged with Escherichia coli. Methods : Animals were randomly assigned to receive monoclonal antibody against CD11b (1 mg/kg, sc) and bovine serum albumin(BSA, 1 mg/kg, sc) 6 hr before, at 0 and 6 hr after intrabronchial challenge of $20x10^9$ CFU/kg E. coli 0111. Animals were randomized to treat either 24, 60 or 90% oxygen after bacterial challenge and begining 4 hr after inoculation, all animals were received 100 mg/kg ceftriaxone qd for 3 days. Peripheral and alveolar neutrophil(by bronchoalveolar lavage) counts and lung injury parameters such as alveolar-arte rial $PO_2$ difference, wet to dry lung weight ratio and protein concentration of alveolar fluid were measured in survived rats at 12 hr and 96 hr. Results : Monoclonal antibody against CD11b decreased circulating and alveolar neutrophil especially more in 12 hr than in 96 hr The lung injury parameters of antibody-treated animals were not different from those of BSA-treated animals. but It was meaningless due to small number of survived animals. The early(6 hr) mortality rate was significantly increased in antibody-treated group(51%) compared to BSA-treated group(31%) (P=0.02) but late(from 12 hr to 72 hr) mortality rate was not different in antibody-treated group(44%) from BSA-treated group(36%) (P =0.089). Conclusion : Leucocyte CD11b/18 adhesion molecule is known to regulate neutrophil migration to the site of infection and inflammation. The monoclonal antibody against CD11b decreased alveolar neutrophil in rats with pulmonary sepsis and increased early mortality rate. Therefore, we can speculate that monoclonal antibody against CD11b blocks of alveolar recruitment of neutrophils, impairs host defense mechanism and increases early mortality rate of pulmonary sepsis in rat.

  • PDF

Feasibility Study of Dose Evaluation of Stereotactic Radiosurgery using GafChromic $EBT^{(R)}$ Film (GafChromic $EBT^{(R)}$ 필름을 이용한 뇌정위방사선치료의 선량분석 가능성 평가)

  • Jang, Eun-Sung;Lee, Chul-Soo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.27-33
    • /
    • 2007
  • Purpose: We have performed SRS (stereotactic radiosurgery) for avm (arterry vein malformation) and brain cancer. In order to verify dose and localization of SRS, dose distributions from TPS ($X-Knife^{(R)}$ 3.0, Radionics, USA) and GafChromic $EBT^{(R)}$ film in a head phantom were compared. Materials and Methods: In this study, head and neck region of conventional humanoid phantom was modified by substituting one of 2.5 cm slap with five 0.5 cm acrylic plates to stack the GafChromic $EBT^{(R)}$ film slice by slice with 5 mm intervals. Four films and five acrylic plates were cut along the contour of head phantom in axial plane. The head phantom was fixed with SRS head ring and adapted SRS localizer as same as real SRS procedure. CT images of the head phantom were acquired in 5 mm slice intervals as film interval. Five arc 6 MV photon beams using the SRS cone with 2 cm diameter were delivered 300 cGy to the target in the phantom. Ten small pieces of the film were exposed to 0, 50, 100, 200, 300, 400, 500, 600, 700, 800, 900 cGy, respectively to calibrate the GafChromic $EBT^{(R)}$ film. The films in the phantom were digitized after 24 hours and its linearity was calibrated. The pixel values of the film were converted to the dose and compared with the dose distribution from the TPS calculation. Results: Calibration curve for the GafChromic $EBT^{(R)}$ film was linear up to 900 cGy. The R2 value was better than 0.992. Discrepancy between calculated from $X-Knife^{(R)}$ 3.0 and measured dose distributions with the film was less than 5% through all slices. Conclusion: It was possible to evaluate every slice of humanoid phantom by stacking the GafChromic EBT film which is suitable for 2 dimensional dosimetry, It was found that film dosimetry using the GafChromic $EBT^{(R)}$ film is feasible for routine dosimetric QA of stereotactic radiosurgery.

  • PDF

Decitabine in the Treatment of Acute Myeloid Leukemia and Myelodysplastic Syndromes, Which Combined with Complex Karyotype Respectively

  • Gao, Su;Li, Zheng;Fu, Jian-Hong;Hu, Xiao-Hui;Xu, Yang;Jin, Zheng-Ming;Tang, Xiao-Wen;Han, Yue;Chen, Su-Ning;Sun, Ai-Ning;Wu, De-Pei;Qiu, Hui-Ying
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.15
    • /
    • pp.6627-6632
    • /
    • 2015
  • Background: We conducted a study exploring the clinical safety and efficacy of decitabine in patients with acute myeloid leukemia (AML) and myelodysplastic syndromes (MDS), combined with a complex karyotype. Materials and Methods: From April 2009 to September 2013, a total of 35 patients with AML/MDS combined with a complex karyotype diagnosed in the First Affiliated Hospital of Soochow University were included for retrospective analysis. All patients were treated with decitabine alone ($20mg/m^2$ daily for 5 days) or combination AAG chemotherapy (Acla 20mg qod*4d, Ara-C $10mg/m^2$ q12h*7d, G-CSF $300{\mu}g$ qd, the dose of G-CSF adjusted to the amount in blood routinely). Results: In 35 patients, 15 exhibited a complete response (CR), and 6 a partial response (PR), the overall response rate (CR+PR) being 60% (21 of 35). Median disease-free survival was 18 months and overall survival was 14 months. In the 15 MDS patients with a complex karyotype, the CR rate was 53.3% (8 of 15); in 20 AML patients with complex karyotype, the overall response rate was 65% (13 of 20). The response rate of decitabine alone (22 cases) was 56.5% (13 of 22), while in the combination chemotherapy group (13 cases), the effective rate was 61.5% (8 of 13)(P>0.05). There are 15 patients with chromosome 7 aberration, after treatment with decitabine, 7 CR, 3 PR, overall response rate was 66.7% (10 of 15). Of 18 patients with 3 to 5 kinds of chromosomal abnormalities, 66.7% demonstrated a response; of 17 with more than 5 chromosomal abnormalities, 52.9% had a response. In the total of 35 patients, with one course (23 patients) and ${\geq}$two courses (12 patients), the overall response rate was 40.9% and 92.3% (P<0.05). Grade III to IV hematological toxicity was observed in 27 cases (75%). Grade III to IV infections were clinically documented in 7 (20%). Grades I to II non-hematological toxicity were infections (18 patients), haematuria (2 patients), and bleeding (3 patients). With follow-up until September 2013, 7 patients were surviving, 18 had died and 10 were lost to follow-up. In the 6 cases who underwent allogeneic hematopoietic stem cell transplantation (HSCT) all were still relapse-free survivors. Conclusions: Decitabine alone or combination with AAG can improve outcome of AML/MDS with a complex karyotype, there being no significant difference decitabine in inducing remission rates in patients with different karyotype. Increasing the number of courses can improve efficiency. This approach with fewer treatment side effects in patients with a better tolerance should be employed in order to create an improved subsequent chance for HSCT.

Usefulness of Gated RapidArc Radiation Therapy Patient evaluation and applied with the Amplitude mode (호흡 동조 체적 세기조절 회전 방사선치료의 유용성 평가와 진폭모드를 이용한 환자적용)

  • Kim, Sung Ki;Lim, Hhyun Sil;Kim, Wan Sun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.29-35
    • /
    • 2014
  • Purpose : This study has already started commercial Gated RapidArc automation equipment which was not previously in the Gated radiation therapy can be performed simultaneously with the VMAT Gated RapidArc radiation therapy to the accuracy of the analysis to evaluate the usability, Amplitude mode applied to the patient. Materials and Methods : The analysis of the distribution of radiation dose equivalent quality solid water phantom and GafChromic film was used Film QA film analysis program using the Gamma factor (3%, 3 mm). Three-dimensional dose distribution in order to check the accuracy of Matrixx dosimetry equipment and Compass was used for dose analysis program. Periodic breathing synchronized with solid phantom signals Phantom 4D Phantom and Varian RPM was created by breathing synchronized system, free breathing and breath holding at each of the dose distribution was analyzed. In order to apply to four patients from February 2013 to August 2013 with liver cancer targets enough to get a picture of 4DCT respiratory cycle and then patients are pratice to meet patient's breathing cycle phase mode using the patient eye goggles to see the pattern of the respiratory cycle to be able to follow exactly in a while 4DCT images were acquired. Gated RapidArc treatment Amplitude mode in order to create the breathing cycle breathing performed three times, and then at intervals of 40% to 60% 5-6 seconds and breathing exercises that can not stand (Fig. 5), 40% While they are treated 60% in the interval Beam On hold your breath when you press the button in a way that was treated with semi-automatic. Results : Non-respiratory and respiratory rotational intensity modulated radiation therapy technique absolute calculation dose of using computerized treatment plan were shown a difference of less than 1%, the difference between treatment technique was also less than 1%. Gamma (3%, 3 mm) and showed 99% agreement, each organ-specific dose difference were generally greater than 95% agreement. The rotational intensity modulated radiation therapy, respiratory synchronized to the respiratory cycle created Amplitude mode and the actual patient's breathing cycle could be seen that a good agreement. Conclusion : When you are treated Non-respiratory and respiratory method between volumetric intensity modulated radiation therapy rotation of the absolute dose and dose distribution showed a very good agreement. This breathing technique tuning volumetric intensity modulated radiation therapy using a rotary moving along the thoracic or abdominal breathing can be applied to the treatment of tumors is considered. The actual treatment of patients through the goggles of the respiratory cycle to create Amplitude mode Gated RapidArc treatment equipment that does not automatically apply to the results about 5-6 seconds stopped breathing in breathing synchronized rotary volumetric intensity modulated radiation therapy facilitate could see complement.