• Title/Summary/Keyword: QCM sensor

Search Result 38, Processing Time 0.028 seconds

Sensing and Degradation Properties in the QCM Gas Sensor Coated with the PVC and GC Blended Liquid (PVC 및 GC물질의 혼합액을 코팅한 QCM가스센서의 센싱 및 열화특성)

  • 장경욱;김명호;이준웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.483-486
    • /
    • 2000
  • In the recognition of the gases using the quartz crystal rnicrobalance (QCM) coated with the film materials, it is important to obtain the recognition ability of gases, and the stability of film coated above the QCM. Especially, the thickness of film coated above the QCM is decreased according with the using circumstance and time of QCM gas sensor. Therefore, the sensing chararcteristics of film is changed with these. In this paper, we coated the lipid GC materials varing with the blended amount of PVC(Po1y Vinyl Chloride) and solution (Tetra Hydrofan:THF) above QCM to obtain the stability of lipid PC film. QCM gas sensors coated with film materials were measured the frequency change in the chamber of stationary gas sensing system injected 1-hexane, ethyl acetate, ethanol and benzene of 20.4 respectively. Also, we measured the degradation characteristics of QCM gas sensor to show the properties of stability.

  • PDF

Sensing and Degradation Characteristics in the QCM Gas Sensor Coated with the PVC and PC (PVC 및 PC 혼합액을 코팅한 QCM 가스센서의 센싱 및 열화 특성)

  • Jang, Kyung-Uk;Kim, Myung-Ho;Lee, Joon-Ung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.04b
    • /
    • pp.176-179
    • /
    • 2000
  • In the recognition of the gases using the quartz crystal microbalance (QCM) coated with the film materials, it is important to obtain the recognition ability of gases, and the stability of film coated above the QCM. Especially, the thickness of film coated above the QCM is decreased according with the using circumstance and time of QCM gas sensor. Therefore, the sensing chararcteristics of film is changed with these. In this paper, we coated the lipid PC (Phosphatidyl Choline) materials varing with the blended amount of PVC(Poly Vinyl Chloride) and solution (Tetra Hydrofan:THF) above QCM to obtain the stability of lipid PC film. QCM gas sensors coated with film materials were measured the frequency change in the chamber of stationary gas sensing system injected 1-hexane, ethyl acetate, ethanol and benzene of $20{\mu}{\ell}$, respectively. We obtained the principal component analysis (PCA) from the frequency change due to the absorption of gas. Also, we measured the degradation characteristics of QCM gas sensor to show the properties of stability.

  • PDF

Fabrication of TiO2/polyelectrolyte thin film for a methyl mercaptan gas sensor (메칠멜캅탄 가스센서용 TiO2/전해질폴리머 박막 제조)

  • Kim, Jin-Ho;Hwang, Jong-Hee;Lee, Mi-Jai;Kim, Sei-Ki;Lim, Tae-Young
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.20 no.5
    • /
    • pp.221-226
    • /
    • 2010
  • Quartz crystal microbalance (QCM) gas sensor to detect methyl mercaptan ($CH_3SH$) gas was fabricated by depositing $TiO_2$ nanoparticles and polyelectrolyte on the electrode of QCM. The $TiO_2$/poly(sodium 4-styrenesulfonate) (PSS) thin film fabricated by a layer-by-layer self-assembly (LBL-SA) method showed a high surface area and increased the sensitivity of gas sensor. When the QCM sensors coated with triethanolamine (TEA) or ($TiO_2$/PSS) were exposed to methyl mercaptan gas (1.0 ppm), the frequency shifts of QCM with TEA casting film and $TiO_2$/PSS thin film were ca. 9 Hz and ca. 24 Hz, respectively. As the bilayer number of ($TiO_2$/PSS) increased, the frequency shift of QCM sensor with ($TiO_2$/PSS) thin film was gradually increased. In addition, the frequency shift of QCM sensor was gradually increased as the concentration of methyl mercaptan gas increased from 0.5 ppm to 2.0 ppm. In this study, the surface morphology and sensor property of QCM sensor coated with ($TiO_2$/PSS) thin film were measured.

Development of a hygroscopic polymer-coated QCM humidity sensor and its characteristics (감습 고분자막이 코팅된 수정미소저울 습도센서 제작 및 특성연구)

  • Kwon, Su-Yong;Kim, Jong-Chul;Choi, Byung-Il;Nham, Hyun-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.395-401
    • /
    • 2005
  • A highly stable quartz crystal microbalance (QCM) that showed a stability of frequencies and exhibited a very low noise level has been developed. The long-term drift was <0.05 Hz/h over a period of 10 h, and the short-term rms (root mean square) noise was <0.015 Hz. Our QCM sensor was used as a humidity sensor employing a poly(methyl methacrylate) (PMMA) polymer film as a hygroscopic layer, which showed good characteristics in the relative humidity (RH) range of $2{\sim}90%$ RH. Comparing the characteristics of the QCM sensor with those of other types of humidity sensors employing PMMA film as a hygroscopic layer, and with other QCM sensors employing other hygroscopic layers is represented.

Degradation Properties in the QCM Gas Sensors Coated with the PEG Materials (PEG 물질을 도포한 QCM 가스센서의 열화특성)

  • Jang, Kyung-Uk;Kim, Myung-Ho;Lee, Won-Jae;Kim, Sang-Keol;Jung, Dong-Hoe;Lee, Joon-Ung;Lee, Ho-Sik;Kim, Tae-Wan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.218-222
    • /
    • 2002
  • In the recognition of the gases using the quartz crystal microbalance (QCM) coated with the PEG film materials, it is important to obtain the recognition ability of gases, and the stability of PEG film coated above the QCM. Especially, the thickness of PEG film coated above the QCM is decreased according with the using circumstance and time of QCM gas sensor. Therefore, the sensing characteristics of PEG film is changed with these. In this paper, we coated the PEG materials varing with the blended amount of PVC(Poly Vinyl Chloride) and chloroform above QCM to obtain the sensitive and the stability of PEG film. We measured the degradation characteristics of QCM gas sensor in the ethyle acetate 50[%] concentration to show the properties of stability.

  • PDF

Optimization of Quartz Crystal Microbalance-Precipitation Sensor Measuring Acetylcholinesterase Activity

  • Kim, Nam-Soo;Park, In-Seon;Kim, Dong-Kyung
    • Journal of Microbiology and Biotechnology
    • /
    • v.16 no.10
    • /
    • pp.1523-1528
    • /
    • 2006
  • The optimization of a batch-type quartz crystal microbalance (QCM)-precipitation sensor measuring acetylcholinesterase (AChE) activity was conducted. To covalently bind AChE onto the gold electrode of a QCM surface, glutaraldehyde cross-linking to a cystamine self-assembled monolayer was tried at different cystamine concentrations. At the optimum conditions of the QCM-precipitation sensor, 0.1 M potassium phosphate buffer (pH 8.0), containing 0.01% Tween 80, was used as the reaction buffer, with the enzyme amount of 5 units for immobilization and the substrate concentration of 50 mg/ml. The current biosensor might find a future applicability to the sum parameter detection on organophosphorus and carbamate pesticides.

Development of QCM dew point sensor and its sensing characteristics study (수정미소저울 노점센서 제작 및 반응특성 연구)

  • Kwon, Su-Yong;Kim, Jong-Chul;Choi, Byung-Il
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.4
    • /
    • pp.269-276
    • /
    • 2006
  • This paper represents development of quartz crystal microbalance (QCM) and usage as a dew point sensor. The temperature of a quartz resonator was controlled precisely from $20^{\circ}C$ to $-30^{\circ}C$ with the ramping rate of $0.1^{\circ}C/s$ by using a custom-made crystal holder housing the quartz resonator associated with a thermoelectric cooler (Peltier cooler), which results in the working range from $15.2^{\circ}C$ to $-24.0^{\circ}C$ based on an accurate holder temperature compensation and temperature effect compensation process. The developed QCM dew point sensor and analysis techniques show very good sensing characteristics at measurement of moist air with the relative humidity from 10 %R.H. to 90 %R.H. generated by a divided-type humidity generator and the dew point temperatures were determined with an accuracy of less than ${\pm}0.18^{\circ}C$, which also showed good agreement with reference values in their error range.

Detection of human and bovine haptoglobin by using quartz crystal microbalance sensor chip containing secondary antibody (이차항체를 포함하는 수정미소저울 센서 칩을 이용한 사람과 소의 헵토글로빈 측정)

  • Kim, Sung-Il;Ha, In-Young;Choi, Suk-Jung
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.160-167
    • /
    • 2009
  • In this study, secondary antibody-containing quartz crystal microbalance(QCM) sensor chip was prepared and utilized for the detection of human and bovine haptoglobin. Anti-goat immunoglobulin G antibody, which is a secondary antibody capable of capturing primary antibodies raised in goat, was immobilized through the reaction between hydrazide and aldehyde group prepared on the QCM surface and antibody respectively. The resulting sensor chip showed higher stability in the repeated surface regeneration with acidic dissociation solution as well as requiring lower amount of primary antibody when compared to the protein G sensor chip. The secondary antibody sensor chip was applied for the estimation of bovine and human haptoglobin.

Sensing and Degradation Properties in the Quartz Crystal Microbalance Coated with the PVC and the Lipid Blended Materials (지질과 PVC의 혼합액을 감응막으로 도포한 수정진동자 가스센서의 센싱 및 열화특성)

  • Jang, Kyung-Uk;Kim, Myung-Ho;Choi, Myung-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2000.07e
    • /
    • pp.44-47
    • /
    • 2000
  • In the recognition of the gases using the quartz crystal microbalance (QCM) coated with the film materials, it is important to obtain the recognition ability of gases, and the stability of film coated above the QCM. Especially, the thickness of film coated above the QCM is decreased according with the using circumstance and time of QCM gas sensor. Therefore, the sensing characteristics of film is changed with these. In this paper, we coated the lipid PC (Phosphatidyl Choline) materials varing with the blended amount of PVC(Poly Vinyl Chloride) and solution (Tetra Hydrofan:THF) above QCM to obtain the sensitive and the stability of lipid PC film. QCM gas sensors coated with film materials were measured the frequency change in the chamber of stationary gas sensing system injected 1-hexane, ethyl acetate, ethanol and benzene of $20{\mu}{\ell}$, respectively. We also measured the degradation characteristics of QCM gas sensor to show the properties of stability.

  • PDF

QCM biosensor for the determination of haptoglobin (헵토글로빈 측정을 위한 수정미소저울 바이오센서 개발)

  • Kim, Sung-Il;Lee, Hyeon-Jeong;Park, Soon-Hyuk;Bhang, Hyun-Soo;Lee, Jin-Ah;Choi, Suk-Jung
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.132-141
    • /
    • 2007
  • The purpose this research is to develop QCM (quartz crystal microbalance) biosensor for the determination of haptoglobin. Haptoglobin is an acute-phase protein with a hemoglobin-binding activity and has a potential to be used as a biomarker for infection or cancer. Haptoglobin level in milk has been used for the diagnosis of cow mastitis. In this study, anti-bovine haptoglobin antibody or bovine hemoglobin was chemically immobilized on the surface of the QCM, and the resulting sensor chips were tested for their response to samples containing haptoglobin at different concentrations. Concentration dependent frequency change was observed with both of the sensor chips. Especially, the sensor chip containing anti-bovine haptoglobin antibody showed sufficient sensitivity in the concentrations typically observed in the cows with mastitis.