안전등급 PLC 기반 제어봉제어계통 제어함 설계 (Design of Control Cabinet Based on Safety PLC for Control Rod Control System)

  • 천종민;김춘경;김석주;이종무;권순만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.291-292
    • /
    • 2007
  • This paper deals with the design of control cabinet based on safety PLC for Control Rod Control System(CRCS). The CRCS controls the operation of the CRDMs(Control Rod Drive Mechanisms). The CRDM moves the control rods which regulate the reactor power. vertically in the reactor core. The Control Cabinet in CRCS makes and conveys control signals to the power cabinet which provides power to the CRDM. We designed the Control Cabinet, based on POSAFE-Q, safety PLC. The application programs working in PLC can be programmed by pSET(POSAFE-Q Software Engineering Tool), Identified Development Environment.

  • PDF

전력계통의 전력조류제어를 위한 진화연산의 비교 (Comparison of Evolutionary Computation for Power Flow Control in Power Systems)

  • 이상근
    • 전기학회논문지P
    • /
    • 제54권2호
    • /
    • pp.61-66
    • /
    • 2005
  • This paper presents an unified method which solves real and reactive power dispatch problems for the economic operation of power systems using evolutionary computation such as genetic algorithms(GA), evolutionary programming(EP), and evolution strategy(ES). Many conventional methods to this problem have been proposed in the past, but most of these approaches have the common defect of being caught to a local minimum solution. The proposed methods, applied to the IEEE 30-bus system, were run for 10 other exogenous parameters and composed of P-optimization module and Q-optimization module. Each simulation result, by which evolutionary computations are compared and analyzed, shows the possibility of applications of evolutionary computation to large scale power systems.

집파리에 대한 Chlorpyrifos, Dichlovos 및 Permethrin의 저항성 유발과 교차저항성 (Resistance Development and Cross-Resistance of Chlorpyrifod, dichorovs and Permethrin-Selected House Fly (Musca domestica L.))

  • 이용규;김정화;이형래
    • 한국응용곤충학회지
    • /
    • 제33권3호
    • /
    • pp.166-172
    • /
    • 1994
  • 집파리를 chlorpyrifos, dichlorvos 및 permethrin 등 3종의 살충제로 누대도태하여 저항성 유발과 교차저항성을 조사하였다. chlorpyrifos, dichlorvos 및 permethrin으로 11세대 누대도채한 계통의 저항성 비는 감수성계통의 암컷에 비하여 42.0배, 3.8배 및 18.7배로 증가하였고, 수컷에서는 42.0배, 4.1배 및 16.4배이었다. chlorpyrifos 도태계통은 permethrin에서 암.수컷 각각 7.5배와 9.6배로 다른 살충제보다 높은 교차저항성을 보였으나, propoxur 에 대해서는 역상관 교차저항성을 나타내었다. dich-lorvos도태계통은 chlorpyrifos에서 암.수각각 13.3배와 15.9배로 높은 교차저항성을 나타내었으며 permethrin 도태계통에서도 chlorpyrifos에 대해서 암.수 각각 8.7배와 9.7배로 비교적 높은 교차저항성을 보였다.

  • PDF

세포내 기생세균의 병원성 관련 유전자의 분석에 관하여 (Analysis of Genes Involved in the Pathogenesis of Intracellularly Survival Bacteria)

  • 전태일;이태윤;김성광
    • Journal of Yeungnam Medical Science
    • /
    • 제9권2호
    • /
    • pp.248-255
    • /
    • 1992
  • S. typhimurium의 세포내생존을 가능케하는 유전자가 다른 세균에서도 존재하는지를 조사하기 위해 8주의 세균주를 사용하였다. phoP-PhoQ operon은 세포내 환경의 자극을 인지하고 그 환경의 적응에 관여하는 유전자의 유전자표현을 조절한다고 알려져 있다. S. typhimurium의 phoP region의 514 basepairs EcoRV DNA fragment를 probe로 dot blot hybridization을 실시하였다. K. pneumoniae, P. aeruginosa, S. marscescens, E. cloacae, S. typhimurium의 phoP/phoQ gene과 유사한 DNA sequence를 가지지 않았으며 E. coli, S. dysenteriae, E. cloacae에서는 세포내 생존가능세균이 아님에도 불구하고 positive signal을 나타내었다. 이상의 결과에서 S. typhimurium외의 세포내 생존가능세균에는 phoP/PhoQ operon이 없다는 것을 알게 되었고 세포내 생존이 가능하지는 않지만 S. typhimurium과 계통발생학적으로 가까운 세균주에서 phoP/phoQ operon이 발견되었다. L. monocytogenes의 세포내 생존에는 phoP/phoQ에 의존하지 않는 어떤 다론 기전이 존재할 것으로 사료된다.

  • PDF

배전계통의 역률보상 콘덴서의 최적 위치 및 용량 산정 (The Optimal Condenser Position & Capacity for Power Factor Compensation in Distribution System)

  • 장정태;전영수
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권10호
    • /
    • pp.1190-1197
    • /
    • 1999
  • The management of power factor(PF) in the distribution line is treated according to the measurement a month about the feeder unit at the substation. In Korea, we have not researched into power factor in distribution system due to it's less weight. The reactive power in advanced countries is controlled automatically by the compensative condenser switch on/off under the monitoring. This paper first presents the optimal condenser position and proper capacity by lagrangue factor ${\lambda}_{Q}$ which is the line loss index about reactive power unit. Therefore, the largest ${\lambda}_{Q}$ node is the condenser injection point and we find out the best condenser capacity when the line loss is saturated by the moderation of condenser volume. By this method, we suggest 0.6% uprising PF by injection of 15 kVA condenser. Additionally, PF is analysed into 5 areas; large city, middle city, small city, farm village, fishing village by the use of Power Platform which is classified the same concept of the low load management in KEPCO. Two feeders of each area are selected by the worst results of PF in specified areas.

  • PDF

계통연계 태양광발전시스템의 제어기법 및 연계운전특성 (A control method and test results of utility interactive photovoltaic power generation systems)

  • 안교상;임희천;황인호;주형준
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.549-553
    • /
    • 1999
  • This paper describes a design method of grid-connected photovoltaic power generation systems with three phase inverter. A 3-phase 50kW photovoltaic power generation system including a DC/AC inverter is designed and made in order to investigate the system performance for grid connection. Also the control scheme of a three phase current-controlled PWM inverter is presented by using d-q transformation. The experimental waveforms show that the proposed system has stable behavior with an unit power factor in utility-interactive operation.

  • PDF

DSTATCOM의 개선된 전원전류 보상 방법 (DSTATCOM improved source current compensation method)

  • 박주현;최종우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.302-304
    • /
    • 2007
  • 본 논문은 3상 3선식 계통의 불평형 선형부하에서 p-q 이론을 이용한 DSTATCOM의 개선된 전류 지령 방법을 제시한다. 전역 통과 필터를 이용하여 부하측 유효전력의 교류성분을 추출하는 것이 기존의 저역 통과 필터를 응용한 것보다 개선된 전류 지령을 만들 수 있음을 보인다. 가상 실험 (Matlab/Simulink)을 통해 제안한 전원 전류 보상 방법의 타당성을 검증한다.

  • PDF

d-q축에서 반복제어기를 적용한 3상 계통연계형 인버터연구 (Research on grid connected 3-phase inverter appling repetitive controller in d-q axis)

  • 임정우;조영훈;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 추계학술대회 논문집
    • /
    • pp.151-152
    • /
    • 2015
  • This paper is research on design controller of grid connected 3-phase inverter. It confirms effects of high harmonics on controller and imposes repetitive controller to minimize effects on the high harmonics. The result of test in this paper is drawn by simulation tool.

  • PDF

하이브리드 타입 커패시터 뱅크를 이용한 공급신뢰도 및 전력품질 개선 방안 연구 (A Study on the Service Reliability and Power Quality Improvement Using Hybrid Type Capacitor Bank)

  • 이한상;윤동희
    • 전기전자학회논문지
    • /
    • 제18권3호
    • /
    • pp.313-319
    • /
    • 2014
  • 전력계통운영의 목표는 전력시스템의 안정성과 신뢰성을 유지하여 원활한 전력을 공급하는 것이다. 안정적인 전력 공급을 위하여 무효전력과 모선 전압에 대한 고려를 해야 하는데, 모선의 전압을 일정 범위 이내로 유지하기 위하여 커패시터 뱅크를 비롯한 다양한 방안이 사용되고 있다. 본 논문에서는 계통 안정도와 전력공급 신뢰도를 상시키기 위한 하이브리드 타입의 커패시터 뱅크 설계 과정에 대하여 기술하였다. 설계 과정에는 커패시터 뱅크의 용량 산정, 리액터 타입 결정 및 리액터 용량 산정과정이 포함된다. 기존의 커패시터 뱅크의 설계과정과 같이 정상상태 Q-V 해석이나 상정사고 분석과 같은 방법을 통하여 무효전력 마진을 계산하여 저전압이 발생하는 모선에 무효전력 보상량을 산정한다. 그리고 고조파 실측을 통해 산출된 개별 고조파의 성분 크기를 기반으로 직렬 리액터의 크기를 산정하는 방식으로 설계과정을 제안하였다. 논문에서는 제안된 방법을 통하여 고조파의 크기가 감소함을 증명하였으며, 특히 5차와 7차 고조파의 저감에 효율적임을 보여주었다.

클러스터링 기법을 이용한 3상 유도전동기 구동시스템의 고장진단 (Fault Diagnosis of 3 Phase Induction Motor Drive System Using Clustering)

  • 박장환;김승석;이대종;전명근
    • 조명전기설비학회논문지
    • /
    • 제18권6호
    • /
    • pp.70-77
    • /
    • 2004
  • 산업 응용분야에서 유도전동기 구동시스템의 예상치 않은 고장은 전체 계통의 정지, 막대한 손실 등을 가져올 수 있다. 이러한 문제점을 해결하는 방법 중에 하나로서 본 논문은 유도전동기 구동을 위한3상 전압형 PWM 인버터에 개방-스위치 손상의 고장진단에 대하여 연구한다. 고장진단 방법으로는, 먼저 고장의 특징추출을 위하여 3상 전류를 d-q 전류로 변환한 후 평균 전류벡터를 구한다. 다음으로 여러 종류의 고장 패턴을 진단하기 위하여 한 인공지능 알고리즘을 제안한다. 제안된 기법은 일반적인 뉴로-퍼지 시스템(adaptive neuro-fuzzy algorithm)의 전제 부에 클러스터링을 도입한 기법으로 적은 계산 양과 좋은 성능을 갖는다. 최종적으로, 여러 불확실한 요소를 가진 고장계통에 대하여 제안된 알고리즘의 유용성을 모의실험에 의해 검증하였다.