• Title/Summary/Keyword: Q&A System

Search Result 1,963, Processing Time 0.028 seconds

A Study on initial value Q of Anti-collision Algorithm in Gen2 Protocol Based RFID Systems (GEN2 기반 RFID 시스템에서의 충돌방지 알고리즘의 초기 값 Q에 대한 연구)

  • Im, Song-Bin;Oh, Young-Hwan
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.5
    • /
    • pp.33-39
    • /
    • 2010
  • In this paper, we propose an improved anti-collision algorithm. We have designed an anti-collision unit using this algorithm for the 18000-6 Type C Class 1 Generation 2 standard (Gen2). The Gen2 standard uses a Q-algorithm for incremental method on the Dynamic Slot-Aloha algorithm. It has basically enhanced performance over the Slot-Aloha algorithm. Unfortunately, there are several non-clarified parts: initial value. If an incorrect value is selected, it causes degradation in performance. To increase throughput and system efficiency, and to decrease tag identification time, we propose an improved anti-collision algorithm. prorosed Q algorithm has an increment of 5% of system efficiency and a decrement of 9% of tag identification time.

Effects of Coenzyme Q10 on the Antioxidant System in Blood and Liver of Laying Hens (산란계에서 Coenzyme Q10 급여가 혈액 및 간 조직의 항산화 작용에 미치는 영향)

  • Moon, Yang-Soo;Jang, In-Surk
    • Korean Journal of Poultry Science
    • /
    • v.49 no.2
    • /
    • pp.115-124
    • /
    • 2022
  • The objective of this study was to investigate the effects of dietary coenzyme Q10 (CoQ10) sources on the antioxidant defense system in the blood and liver of laying hens. Thirty-six 40-wk old Lohmann Brown hens were randomly assigned to three groups based on body weight, with four cages with three layers each. Laying hens were divided into one of the following groups: control (CON), powdered CoQ10 (PCoQ, 100 mg/kg diet), and emulsified CoQ10 (ECoQ, 100 mg/kg diet). All hens were fed a control diet or a control diet supplemented with powdered or emulsified CoQ10 ad libitum for five weeks. There were no differences in body weight, weight gain, and organ weights among the treatment groups, including the liver and spleen. The blood total antioxidant power (TAP) in the ECoQ group increased (P<0.05) by approximately 2-fold compared to that in the CON group. However, there was no significant difference in blood TAP levels between the PCoQ and ECoQ groups, although a decreasing trend (P<0.13) was observed for levels of TAP in the ECoQ group. The mRNA expression and specific activities of superoxide dismutase, glutathione peroxidase, and catalase in the liver were not affected by dietary CoQ10 or type of CoQ10. However, hepatic lipid peroxidation in the ECoQ group was lower (P<0.05) than in the CON group. In conclusion, emulsified CoQ10 increased blood TAP and decreased hepatic lipid peroxidation without affecting antioxidant enzymes, suggesting that emulsified CoQ10 might be more applicable as an active antioxidant supplement than powdered type in laying hens.

A Study on Tuning Factor(δ) and Quality Factor(Q) Values in Design of Single-Tuned Passive Harmonic Filters (단일동조 수동고조파필터 설계시의 동조계수(δ) 및 양호도(Q)값 연구)

  • Cho, Young-Sik;Cha, Han-Ju
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.64-70
    • /
    • 2010
  • This paper presents how to decide on tuning factor(${\delta}$) and quality factor(Q) values in design of single-tuned passive harmonic filters. Tuning factor(${\delta}$) and quality factor(Q) values have to consider before decision on circuit parameters of passive filters. A Study on these two value has not been scarcely performed and only experienced values has been used in passive harmonic filter design by far. As a experienced value, in cases of 5th and 7th filter, tuning factor(${\delta}$) is about 0.94 and 0.96 respectively and quality factor(Q) is, in all cases of, 50. If Single-tuned passive harmonic filter will be off-tuned, performance of filter will be decreased steeply and occur to parallel resonance between system reactance and filter capacitance. Therefore During the operation, In order not to off-tuning, Filter must be tuned at former order than actual tuning order. This is the same that total impedance of filter must have a reactive impedance. In this paper, Tuning factor(${\delta}$) is decided via example of real system and using the bode-plot and then performance of filters confirmed by filter current absorbtion rate. And Quality factor(Q) decided using the bode plot in example system and then performance of filters confirmed by filter current absorbtion rate also, which makes a calculated filter parameters to satisfy IEEE-519 distortion limits. Finally, Performance of the designed passive harmonic filter using the tuning factor(${\delta}$) and quality factor(Q) values, decided in this paper is verified by experiment and shows that 5th, 7th, 9th, 11th and 13th current harmonic distortions are decreased within IEEE-519 distortion limits, respectively.

A Study on the System Loss Minimizing Algorithm by Optimal Re-location of Static Condenser Using System Power Loss Sensitivity (계통손실 감소를 위한 전력용 콘덴서의 適正 再配置에 대한 연구)

  • 이상중;김건중;정태호;김원겸;김용배
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.44 no.1
    • /
    • pp.21-24
    • /
    • 1995
  • The larger and the more complicated the system size and configuration grow, the more serious the system loss problem becomes. Exessive system loss causes severs system voltage depression, which even may result in system voltage collapse. This paper proposes an effective tool for minimizing the system power loss by optimal re-location of the static condenser based on the system loss sensitivity index .lambda.$_{Q}$. It is possible to determine the optimal location and amount of VAR investment for minimizing the system loss by priority of .lambda.$_{Q}$ index given for each bus. Several computational techniques for avoiding divergency of the load flow solution are proposed. The loss sensitivity index .lambda.$_{Q}$ uses information of normal power flow equations and their Jacobians. Two case studies proved the effectiveness of the algorithm proposed.posed.

  • PDF

EXISTENCE OF SOLUTIONS FOR FRACTIONAL p&q-KIRCHHOFF SYSTEM IN UNBOUNDED DOMAIN

  • Bao, Jinfeng;Chen, Caisheng
    • Bulletin of the Korean Mathematical Society
    • /
    • v.55 no.5
    • /
    • pp.1441-1462
    • /
    • 2018
  • In this paper, we investigate the fractional p&q-Kirchhoff type system $$\{M_1([u]^p_{s,p})(-{\Delta})^s_pu+V_1(x){\mid}u{\mid}^{p-2}u\\{\hfill{10}}={\ell}k^{-1}F_u(x,\;u,\;v)+{\lambda}{\alpha}(x){\mid}u{\mid}^{m-2}u,\;x{\in}{\Omega}\\M_2([u]^q_{s,q})(-{\Delta})^s_qv+V_2(x){\mid}v{\mid}^{q-2}v\\{\hfill{10}}={\ell}k^{-1}F_v(x,u,v)+{\mu}{\alpha}(x){\mid}v{\mid}^{m-2}v,\;x{\in}{\Omega},\\u=v=0,\;x{\in}{\partial}{\Omega},$$ where ${\Omega}{\subset}{\mathbb{R}}^N$ is an unbounded domain with smooth boundary ${\partial}{\Omega}$, and $0<s<1<p{\leq}q$ and sq < N, ${\lambda},{\mu}>0$, $1<m{\leq}k<p^*_s$, ${\ell}{\in}R$, while $[u]^t_{s,t}$ denotes the Gagliardo semi-norm given in (1.2) below. $V_1(x)$, $V_2(x)$, $a(x):{\mathbb{R}}^N{\rightarrow}(0,\;{\infty})$ are three positive weights, $M_1$, $M_2$ are continuous and positive functions in ${\mathbb{R}}^+$. Using variational methods, we prove existence of infinitely many high-energy solutions for the above system.

An experimental study on the improving reliability of grouting by using p-q-t chart analyzing technique (P-q-t chart 분석기법을 이용한 그라무팅 신뢰성 향상 방안에 관한 실험적 연구)

  • Chon, Byung-Sik;Choi, Dong-Chan;Kim, Jin-Chun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.10 no.4
    • /
    • pp.383-395
    • /
    • 2008
  • The grouting is one of the improved techniques which is aim to decrease the permeability and to strengthen the soft ground. But The grouting method has many problems about a suitability of grouting procedure and an effectiveness of grouting after grouting work because of a technical characteristic operated inside the soil. The grouting $p{\sim}q{\sim}t$ chart of a typical index about grouting rate and time alteration of grouting pressure is one method to estimate the suitability of grouting factor with monitoring during grouting procedure. This study is automatic grouting system (AGS) which can control the testing and grouting procedures. It can make the detailed $p{\sim}q{\sim}t$ chart and analyze the grouting characters of the ground by comparing the detailed pattern of $p{\sim}q{\sim}t$ chart with standard pattern. If using the $p{\sim}q{\sim}t$ chart derived from AGS in the grouting work, it is an objective standard estimating the suitability of grouting factor with grouting materials, grouting method, grouting rate and grouting pressure, as results it expects successfully to improve reliability of the grouting work.

  • PDF

Y-HisOnto: A History Ontology Model for Q&A System (Y-HisOnto: Q&A 시스템에서의 활용을 위한 역사 온톨로지 모형)

  • Lee, In Keun;Jung, Jason J.;Hwang, Dosam
    • Annual Conference on Human and Language Technology
    • /
    • 2013.10a
    • /
    • pp.156-159
    • /
    • 2013
  • 본 논문에서는 시간 개념이 포함된 역사적 지식을 표현할 수 있는 사건 온톨로지(event ontology) 기반의 역사 온톨로지 모형인 Y-HisOnto 를 제안한다. 제안한 역사 온톨로지 모형은 기존의 온톨로지에서 사용되는 이진 관계(binary-relationship)로 표현된 단편적 지식들을 조합하여 다진 관계(n-ary relationship)를 이용하여 역사적 사건 관련 지식을 표현한다. 제안한 온톨로지 모형에 기반하여 사건 중심의 지식을 온톨로지로 구축하고, 사건 관련 질의에 대해 온톨로지 논리 검색 실험을 수행함으로써 제안한 온톨로지 모형이 Q&A 시스템에서 효과적으로 활용될 수 있음을 확인한다.

  • PDF

EQUIDISTRIBUTION OF PERIODIC POINTS OF SOME AUTOMORPHISMS ON K3 SURFACES

  • Lee, Chong-Gyu
    • Bulletin of the Korean Mathematical Society
    • /
    • v.49 no.2
    • /
    • pp.307-317
    • /
    • 2012
  • We say (W, {${\phi}_1,\;{\ldots}\;,{\phi}_t$}) is a polarizable dynamical system of several morphisms if ${\phi}_i$ are endomorphisms on a projective variety W such that ${\otimes}{\phi}_i^*L$ is linearly equivalent to $L^{{\otimes}q}$ for some ample line bundle L on W and for some q > t. If q is a rational number, then we have the equidistribution of small points of given dynamical system because of Yuan's work [13]. As its application, we can build a polarizable dynamical system of an automorphism and its inverse on a K3 surface and can show that its periodic points are equidistributed.

A Study on a 3-phase Active Power Filter Under Unbalanced Input Voltage (불평형 전원시스템을 고려한 3상 능동전력 필터에 관한 연구)

  • 이승요;조준석;최규하;목형수;박영길;신우석
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.233-238
    • /
    • 1997
  • An important assumption for the active power filter design using instantaneous power theory and the d-q transformation method in a 3-phase power system is based on balanced 3-phase system. However, under pratical conditions, the 3-phase power system can not be continuously balanced due to unbalanced loading. In this paper, a method to control the 3-phase active power filer using instantaneous power theory and the d-q transformation under unbalanced power system is presented and the theoretical results are verified by simulated results.

  • PDF

Designing of the Beheshtabad water transmission tunnel based on the hybrid empirical method

  • Mohammad Rezaei;Hazhar Habibi
    • Structural Engineering and Mechanics
    • /
    • v.86 no.5
    • /
    • pp.621-633
    • /
    • 2023
  • Stability analysis and support system estimation of the Beheshtabad water transmission tunnel is investigated in this research. A combination approach based on the rock mass rating (RMR) and rock mass quality index (Q) is used for this purpose. In the first step, 40 datasets related to the petrological, structural, hydrological, physical, and mechanical properties of tunnel host rocks are measured in the field and laboratory. Then, RMR, Q, and height of influenced zone above the tunnel roof are computed and sorted into five general groups to analyze the tunnel stability and determine its support system. Accordingly, tunnel stand-up time, rock load, and required support system are estimated for five sorted rock groups. In addition, various empirical relations between RMR and Q i.e., linear, exponential, logarithmic, and power functions are developed using the analysis of variance (ANOVA). Based on the significance level (sig.), determination coefficient (R2) and Fisher-test (F) indices, power and logarithmic equations are proposed as the optimum relations between RMR and Q. To validate the proposed relations, their results are compared with the results of previous similar equations by using the variance account for (VAF), root mean square error (RMSE), mean absolute percentage error (MAPE) and mean absolute error (MAE) indices. Comparison results showed that the accuracy of proposed RMR-Q relations is better than the previous similar relations and their outputs are more consistent with actual data. Therefore, they can be practically utilized in designing the tunneling projects with an acceptable level of accuracy and reliability.