• Title/Summary/Keyword: Pyrex glass

Search Result 104, Processing Time 0.031 seconds

Enrichment of Lithium Isotopes by Cation Exchange Chromatography (양이온 교환 크로마토그래피에 의한 리튬 동위원소의 농축)

  • Kim, Dong Won;Kim, Chang Suck;Choi, Ki Young;Jeon, Young Shin;Jeong, Young Kyu;Park, Sung Up
    • Analytical Science and Technology
    • /
    • v.7 no.2
    • /
    • pp.201-204
    • /
    • 1994
  • Cation exchange column chromatography of lithium was carried out to investigate the lithium isotope separation in aqueous ion exchange system. A Pyrex glass column of $50cm{\times}6mm$ inner radius with a water jacket was used as the separation column in experiment. Upon column chromatography using hydrochloric and succinic acid mixtures as an elunent, single separation factor, ${\alpha}$, 1.0068 was obtained. From the experiment, it was found that $^6Li$ was enriched in the resin phase and $^7Li$ in the solution phase.

  • PDF

Wafer Level Packaging of RF-MEMS Devices with Vertical Feed-through (수직형 Feed-through 갖는 RF-MEMS 소자의 웨이퍼 레벨 패키징)

  • Park, Yun-Kwon;Lee, Duck-Jung;Park, Heung-Woo;kim, Hoon;Lee, Yun-Hi;Kim, Chul-Ju;Ju, Byeong-Kwon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.10
    • /
    • pp.889-895
    • /
    • 2002
  • Wafer level packaging is gain mote momentum as a low cost, high performance solution for RF-MEMS devices. In this work, the flip-chip method was used for the wafer level packaging of RF-MEMS devices on the quartz substrate with low losses. For analyzing the EM (electromagnetic) characteristic of proposed packaging structure, we got the 3D structure simulation using FEM (finite element method). The electric field distribution of CPW and hole feed-through at 3 GHz were concentrated on the hole and the CPW. The reflection loss of the package was totally below 23 dB and the insertion loss that presents the signal transmission characteristic is above 0.06 dB. The 4-inch Pyrex glass was used as a package substrate and it was punched with air-blast with 250${\mu}{\textrm}{m}$ diameter holes. We made the vortical feed-throughs to reduce the electric path length and parasitic parameters. The vias were filled with plating gold. The package substrate was bonded with the silicon substrate with the B-stage epoxy. The loss of the overall package structure was tested with a network analyzer and was within 0.05 dB. This structure can be used for wafer level packaging of not only the RF-MEMS devices but also the MEMS devices.

A Study of the Viscosity of Some Electrolytic Solutions and Its Concentration Function (電解質溶液의 粘度係數의 測定과 濃度關係에 對한 考察)

  • Sakong, Yull;Hwang, Jung-Eui
    • Journal of the Korean Chemical Society
    • /
    • v.8 no.1
    • /
    • pp.9-14
    • /
    • 1964
  • The viscosities of strong electrolytic solutions, such as KCl, KI and NaI have been measured over a fairy wide range of concentration variation (from 0.00002 to 3.7M). It was hoped that a study of the data in the light of modern theories on solution might reveal new relation between viscosity and surface tension of electrolytic solution. To secure more accurate measurements of viscosity and surface tension of the solutions, Ostwald viscometer was made with pyrex glass and modified the timing system for the transit of the meniscus with a new electronics system and with a pulse counter. As the experimental data obtained were in good agreement with the Jone's values, Jones-Dole equations for the electrolytic solutions were deduced, ${\eta}KCl\;=\;1\;+\;0.0052{\sqrt{c}}\;-\;0.01612c\;+\;0.00808c^2\;at\;30^{\circ}C$ ${\eta}KI\;=\;1\;+\;0.0220{\sqrt{c}}\;-\;0.01290c\;+\;0.02988c^2\;at\;25^{\circ}C$${\eta}Na\; =\;1\;+\;0.0240{\sqrt{c}}\;-\;0.0640c\;+\;0.03268c^2\;at\;25^{\circ}C$Gruneisen effect appeared in the dilute solution, whereas anti-Gruneisen effect was found for the extremely dilute solution. No satisfactory interpretation for the variation of the viscosity with concentration can be found at the present.

  • PDF

Align-free Micro-optic Mach-Zehnder Interferometric Filter (정렬에 무관한 마이크로옵틱 마하젠더 간섭계형 필터)

  • Lee, Jong-Hoon;Kim, Hyun-Deok;Song, Jae-Won
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.3
    • /
    • pp.285-289
    • /
    • 2006
  • A novel alignment-free micro-optic MZI filter has been demonstrated. The filter is composed of two fiber-pigtailed collimators and a beam-splittingplate with a periodically etched stripe pattern. We fabricated the plate through a standard lithographic formulation process by using a pyrex substrate glass with SU-8 resist coating on its one of the surfaces. The maximum insertion loss of the implemented filter was less than 2 dB over 1000 nm to 1600 nm and the extinction ratio was larger than 33 dB. The measured PDL within the 3-dB pass band of the filter was less than 0.15dB and the maximum extinction ratio variation was less than 2 dB even when the worst alignment error occured.

Characteristics of Liquid-Liquid Direct Contact Heat Exchanger for a Solar System (태양열 이용을 위한 직접접촉식 액-액 열교환기 특성)

  • 강인석;김종보;강용혁;곽희열
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.12
    • /
    • pp.3276-3286
    • /
    • 1994
  • In most direct contact liquid-liquid heat exchangers, oil or hydrocarbon with a density less than water is normally used as dispersed working fluid. The main difficulty that arises with this arrangement lies in the control of the interface at the top of the column. When it is connected with a solar collector which uses water as its working fluid, the main difficulties arise from the fact that the water can be frozen during winter time. In order to solve these problems and to demonstrate the technical feasibility of a direct contact liquid-liquid heat exchanger, liquids heavier than water with low freezing temperature has been utilized as dispersed phase liquids in a small laboratory scale model made of pyrex glass. In the present investigation, dimethyl phthalate(C/sub 6/H/sub 4/)COOCH/sub 3/)/sub 2/) and diethyl phthalate (C/sub 6/H/sub 4/(CO/sub 2/C/sub 2/H/sub 5/)/sub 2/) are utilized as heavy dispersed phase working fluids. The results of the present investigation the technical in the utilization of heavier dispersed working liquid in the spray-column liquid-liquid heat exchanger for a solar system. The overall average temperature difference along the column is found to be almost half of the initial temperature difference between the dispersed and the continuous phase. Despite the fact that the two phthalates tested in the experiment differ significantly in some of their physical properties, the volumetric heat transfer coefficients in terms of dispersed fluid superficial velocities were found to be similar for both phthalates tested.

The transparent and conducting tin oxide thin films by the pulse laser deposition (펄스레이저증착에 의한 투명전도성 산화주석 박막)

  • 윤천호;박성진;이규왕
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.2
    • /
    • pp.114-121
    • /
    • 1997
  • The transparent conductiong thin films of tin oxides were prepared on pyrex glass substrates by the pulse laser deposition. In the atmospheres of vacuum, O2, and $Sn(CH_3)_4$ a polycrystalline $SnO_2$ target was ablated by Nd-YAG laser beam to deposit thin films on the substrates at room temperature, and as-deposited films were subsequently heat-treated in the air for 2 h at 230, 420 and $610^{\circ}C$, respectively. The characteristics of the thin films were examined by UV-VIS-NIR spectrometry and X-ray diffractometry, and the electrical properties were measured by four-point probe method along with film thickness monitored by the stylus method. It was observed that in the presence of $Sn(CH_3)_4$, $SnO_2$ phases were grown even at room temperature. This suggests that the microplasma producted during the laser ablation plays an important role in the dissociaation of precursor molecules.

  • PDF

Blood Flow Changes by Anastomotic Method in Fontan Operation (폰탄 수술에서 문합방법에 따른 혈류 변화)

  • Kim, S.H.;Park, Y.H.;Cho, B.K.;Kim, J.H.;Hong, Y.S.;Kim, Y.H.;Kim, S.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.203-206
    • /
    • 1996
  • To understand the local fluid dynamics for different desists of Fontan operation, five models were made out of Pyrex glass to facilitate in-vitro study. Model I, II and III have same position of the center of the anastomosis of the IVC( inferior vena cava) with that of the SVC(superior vena cava), but Model IV and V have 10 mm offset between them. Also the anastomotic junction angles are different(Model I and $IV:90^{\circ}$, Model II and $V:70^{\circ}$, Model $III:45^{\circ}$). These models were then connected to a flow loop for flow visualization study. In Model I any dominant vortex was not seen in the central region of the juntion, but a large unstable vortex was created in the Model II and III. In Model IV and V a significant stagnation region was created in the middle of the offset region. It also showed that the flow direction from the IVC and SVC to the LPA(left pulmonary artery) and RPA(right pulmonary artery) highly depends on the offset of the junction rather than the anastomotic junction angle.

  • PDF

Study on Plrene Removal Characteristic From An Artificially Contaminated EPA Synthetic Soil Matrix With Varying Heat Treatment Conditions (Pyrene으로 오염된 EPA토양의 열적처리조건에 따른 오염물질 제거 특성 연구)

  • 김영규;양고수
    • Journal of Korea Soil Environment Society
    • /
    • v.5 no.2
    • /
    • pp.55-66
    • /
    • 2000
  • A U.S EPA Synthetic soil matrix was used for reference neat soil and pyrene contaminated soil. For the contaminated soil, 4.79 wt.% pyrene was dissolved completely into the djchlorornethane, and the soil was evenly soaked with the pyrene solution. The contaminated soil samples(50$\pm$0.5mg) were heated in a modified electrical screen heater reactor which consisted of a thin stainless foil (3.5cm$\times$13cm$\times$0.00254cm, 302 stainless steel shim), two electrodes, and a 20cm dia. $\times$30cm tall cylindrical Pyrex chamber sealed at both ends by aluminum flanges. The heating rate and time conditions were selected as $455^{\circ}C$ @ $1137^{\circ}C$ /s, $760^{\circ}C$ @ $950^{\circ}C$ /s and $977^{\circ}C$ @ $977^{\circ}C$/s. Tar samples after heating the soils were collected on the aluminum foil funnel and a glass filter paper (25mm dia. filter paper) The tar sample and remnant soil on the reactor were extracted with dichloromethane covering the filters, foils and soil by sonicating each in the waterbath for 10 minutes. The extractions were run on a HPLC. At the low peak temperature(about $455^{\circ}C$ @ $1137^{\circ}C$/s) the color of tar was "white", at the middle peak temperature (about 76$0^{\circ}C$ @ 95$0^{\circ}C$/s) the color of tar was "pink brown", at the high peak temperature (about 977$^{\circ}C$ @ 977$^{\circ}C$/s) the color of tar was "dark brown". Cyclopeta(cd)pyrene (CPEP) , which is an interesting species due to mutagenic effect on human cells, was detected in tar samples only above the middle peak temperature. This species was not detected at the low peak temperature. Six isomers of bipyrene were detected. Phenanthrene(C$_{14}$ $H_{10}$) and cyclopenta(def)phenanthrene(C$_{15}$ $H_{10}$) were also detected, but their content was very small relative to the other listed compounds.to the other listed compounds.

  • PDF

A Development of Tapered Metallic Microneedle Array for Bio-medical Application (생체의학에 적용 가능한 테이퍼형태의 금속성 마이코로니들 어레이의 개발)

  • Che Woo Seong;Lee Jeong-Bong;Kim Kabseog;Kim Kyunghwan;Jin Byung-Uk
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.11 no.2 s.31
    • /
    • pp.59-66
    • /
    • 2004
  • This paper presents a novel fabrication process for a tapered hollow metallic microneedle array using backside exposure of SU-8, and analytic solutions of critical buckling of a tapered hollow microneedle. An SU-8 meta was formed on a Pyrex glass substrate and another SU-8 layer, which was spun on top of the SU-8 mesa, was exposed through the backside of the glass substrate. An array of SU-8 tapered pillar structures. with angles in the range of $3.1^{\circ}{\sim}5^{\circ}$ was formed on top of the SU-8 mesa. Conformal electrodeposition of metal was carried out followed by a mechanical polishing using a pianarizing polymeric layer. All organic layers were then removed to create a metallic hollow microneedle array with a fluidic reservoir on the backside. Both $200{\mu}m\;and\;400{\mu}m$ tall, 10 by 10 arrays of metallic microneedles with inner diameters of the tip in the range of $33.6{\sim}101\;{\mu}m$ and wall thickness of $10{\mu}m\;-\;20{\mu}m$ were fabricated. Analytic solutions of the critical buckling of arbitrary-angled truncated cone-shaped columns are also presented. It was found that a single $400{\mu}m$ tall hollow cylindrical microneedle made of electroplated nickel with a wall thickness of $20{\mu}m$, a tapered angle of $3.08^{\circ}$ and a tip inner diameter of $33.6{\mu}m$ has a critical buckling force of 1.8 N. This analytic solution can be used for square or rectangular cross-sectioned column structures with proper modifications.

  • PDF

Microfluidic Immuno-Sensor Chip using Electrical Detection System (전기 검출 시스템을 이용한 Microfluidic Immuno-Sensor Chip)

  • Maeng, Joon-Ho;Lee, Byung-Chul;Cho, Chul-Ho;Ko, Yong-Jun;Ahn, Yoo-Min;Cho, Nahm-Gyoo;Lee, Seoung-Hwan;Hwang, Seung-Yong
    • KSBB Journal
    • /
    • v.21 no.5
    • /
    • pp.325-330
    • /
    • 2006
  • This study presents the characterization of an integrated portable microfluidic electrical detection system for fast and low volume immunoassay using polystyrene microbead, which are used as immobilization surfaces. In our chip, a filtration method using the microbead was adopted for sample immobilization and immunogold silver staining(IGSS) was used to increase the electrical signal. The chip is composed of an inexpensive and biocompatible Polydimethylsiloxane(PDMS) layer and Pyrex glass substrate. Platinum microelectrodes for electric signal detection were fabricated on the substrate and microchannel and pillar-type microfilters were formed in the PDMS layer. With a fabricated chip, we reacted antigen and antibody according to the procedures. Then, silver enhancer was injected to increase the size of nanogold particles tagged with the second antibody. As a result, microbeads were connected to each other and formed an electrical bridge between microelectrodes. Resistance measured through the electrodes showed a difference of two orders of magnitude between specific and nonspecific immuno-reactions. The detection limit was 10 ng/ml. The developed immunoassay chip reduced the total analysis time from 3 hours to 50 min. Fast and low-volume biochemical analysis has been successfully achieved with the developed microfilter and immuno-sensor chip, which is integrated to the microfluidic system.