• Title/Summary/Keyword: Pylon

Search Result 135, Processing Time 0.021 seconds

Investigations on seismic response of two span cable-stayed bridges

  • Bhagwat, Madhav;Sasmal, Saptarshi;Novak, B.;Upadhyay, A.
    • Earthquakes and Structures
    • /
    • v.2 no.4
    • /
    • pp.337-356
    • /
    • 2011
  • In this paper, cable-stayed bridges with single pylon and two equal side spans, with variations in geometry and span ranging from 120 m to 240 m have been studied. 3D models of the bridges considered in this study have been analysed using ANSYS. As the first step towards a detailed seismic analysis, free vibration response of different geometries is studied for their mode shapes and frequencies. Typical pattern of free vibration responses in different frequencies with change in geometry is observed. Further, three different seismic loading histories are chosen with various characteristics to find the structural response of different geometries under seismic loading. Effect of variation in pylon shape, cable arrangement with variation in span is found to have typical characteristics with different structural response under seismic loading. From the study, it is observed that the structural response is very much dependent on the geometry of the cable-stayed bridge and the characteristics of the seismic loading as well. Further, structural responses obtained from the study would help the design engineers to take decisions on geometric shapes of the bridges to be constructed in seismic prone zones.

Validation of Chimera Grid Method Applied to UMSAPv With Prediction of Carriage Load (장착하중 예측을 통한 UMSAPv에 적용된 중첩 격자 기법 검증)

  • Kang, SeonWook;Ahn, Kyehyun;Lee, Seungsoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.10
    • /
    • pp.669-676
    • /
    • 2022
  • In this paper, the carriage load analyses of stores installed on aircraft are conducted to validate the chimera grid method applied to an unstructured CFD solver, UMSAPv. First, the chimera grid method of UMSAPv is verified for the well-known Eglin Wing/Pylon/Finned store problem. Next, an angle of attack sweep of F/A-18C clean configuration is conducted at a subsonic speed. The computed results are compared with the results of the previous study using MSAPv, a structured CFD solver, to show the validity of Umsapv. Finally, the carriage of F/A-18C JDAM is carried out with a chimera grid as well as a single block grid. The computed results are compared with other computational, experimental and the flight tests.

Seismic Fragility Analysis by Key Components of a Two-pylon Concrete Cable-stayed Bridge (2주탑 콘크리트 사장교의 주요 부재 지진 취약도 분석)

  • Shin, Yeon-Woo;Hong, Ki-Nam;Kwon, Yong-Min;Yeon, Yeong-Mo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.4
    • /
    • pp.26-37
    • /
    • 2020
  • This study intends to present a fragility analysis method suitable for concrete cable-stayed bridges by performing an analysis reflecting design criteria and material characteristics from the results of inelastic time-history analysis. In order to obtain the fragility curve of the cable-stayed bridge, the limit state of the main component of the cable-stayed bridge is determined, and the damage state is classified by comparing it with the response value based on inelastic time history analysis. The seismic fragility curve of the cable-stayed bridge was made by obtaining the probability of damage to PGA that the dynamic response of the vulnerable parts to input ground motion would exceed the limit state of each structural member. According to the pylon's fragility curve, the probability of moderate damage at 0.5g is 32% for the longitudinal direction, while 7% for the transversal direction, indicating that the probability of damage in the longitudinal direction is higher in the same PGA than in the transversal direction. The seismic fragility curve of the connections showed a very high probability of damage, meaning that damage to the connections caused by earthquakes is very sensitive compared to damage to the pylon and cables. The cable's seismic fragility curve also showed that the probability of complete damage state after moderate damage state gradually decreased, resulting in less than 30% probability of complete damage at 2.0g.

항공기에 장착된 POD 연결부의 구조 신뢰성 평가

  • 윤혁중;신규인;박상윤;박재학;김도형;주진원;주영식;전승문
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2003.10a
    • /
    • pp.101-106
    • /
    • 2003
  • 항공기 외부 장착물인 POD는 전자전 방해장치(ECM, electronic counter measures)로서 전자방해 장비 및 부분 부품인 전ㆍ후방 러그(lug)와 외부 케이스로 이루어져 있다. POD는 항공기 외부 동체 하단부 및 파일런(pylon)에 장착되어 작동하므로 항공기의 운용중 이륙부터 착륙간의 기동에 의한 피로하중을 주로 받게 되므로 POD 부품들에 대한 구조 건전성 확보하기 위해서는 MIL-STD-1530의 요구에 따라 내구성(durability) 및 손상허용설계(damage tolerance design) 의 평가가 요구되고 있다.(중략)

  • PDF

Nonlinear Analysis of Cable-Stayed Bridges Using Energy Method (에너지법을 이용한 사장교의 비선형 해석)

  • Choi, Dong-Ho;Lee, Gi-Young
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.10a
    • /
    • pp.187-194
    • /
    • 2003
  • This paper presents an energy method for the analysis of the in-plane ultimate load capacity of cable-stayed bridges considering deck and pylon connection. The potential energy of the whole bridge, including bridge deck, stayed cables, and pylons, and the work done by external loads are considered in the development of the bridge energy equation. Both geometric and material nonlinearities are taken into account in the analysis. The method is simple to use and has a high convergence rate.

  • PDF

Behavior of Cable Suppored Bridges with RC Pylon Under Varying Seismicities (입력지진 세기에 따른 콘크리트 주탑 케이블교량의 부재별 거도 특성 연구)

  • Lim, Young-Geun;Jeong, Hyeok-Chang;Kim, Ick-Hyun;Lee, Jong-Seok
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.349-352
    • /
    • 2006
  • According to current bridge design code cable supported bridges are designed generally against 1000-year-return-period earthquake. Considering its importance, however, it may be desirable to design against 2400-year-return-period earthquake. But the seismic behavior of cable supported bridges under higher seismicity is not investigated fully. In this study, several cable supported bridges were analyzed under higher seismicity and then the response forces in prime members were compared with those analyzed under current design earthquake.

  • PDF

Design of Vam Cong Cable Stayed Bridge in Vietnam (베트남 밤콩 사장교의 설계)

  • Lee, Yong-Jin;Kang, Jeong-Woon;Bae, Sang-Woon;Yun, Yeon-Suk;Lho, Byeong-Cheol
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.1 no.2
    • /
    • pp.120-127
    • /
    • 2013
  • Vam Cong Cable Stayed Bridge which has 450m main span length is one of the Central Mekong Delta Region Connectivity Project and is located in Cuu Long Delta Region. It has steel-concrete composite girder with 4 lane and the type of cable is multi strand cable. The improved H-shape pylon and cast-in-place bored piles were applied. High strength concrete is applied for pylon, precast concrete slab and Cast-in-Situ concrete pile to ensure the structural safety. The present paper describe the design specifications and main features of Vam Cong Cable Stayed Bridge design.

Nonlinear dynamic performance of long-span cable-stayed bridge under traffic and wind

  • Han, Wanshui;Ma, Lin;Cai, C.S.;Chen, Suren;Wu, Jun
    • Wind and Structures
    • /
    • v.20 no.2
    • /
    • pp.249-274
    • /
    • 2015
  • Long-span cable-stayed bridges exhibit some features which are more critical than typical long span bridges such as geometric and aerodynamic nonlinearities, higher probability of the presence of multiple vehicles on the bridge, and more significant influence of wind loads acting on the ultra high pylon and super long cables. A three-dimensional nonlinear fully-coupled analytical model is developed in this study to improve the dynamic performance prediction of long cable-stayed bridges under combined traffic and wind loads. The modified spectral representation method is introduced to simulate the fluctuating wind field of all the components of the whole bridge simultaneously with high accuracy and efficiency. Then, the aerostatic and aerodynamic wind forces acting on the whole bridge including the bridge deck, pylon, cables and even piers are all derived. The cellular automation method is applied to simulate the stochastic traffic flow which can reflect the real traffic properties on the long span bridge such as lane changing, acceleration, or deceleration. The dynamic interaction between vehicles and the bridge depends on both the geometrical and mechanical relationships between the wheels of vehicles and the contact points on the bridge deck. Nonlinear properties such as geometric nonlinearity and aerodynamic nonlinearity are fully considered. The equations of motion of the coupled wind-traffic-bridge system are derived and solved with a nonlinear separate iteration method which can considerably improve the calculation efficiency. A long cable-stayed bridge, Sutong Bridge across the Yangze River in China, is selected as a numerical example to demonstrate the dynamic interaction of the coupled system. The influences of the whole bridge wind field as well as the geometric and aerodynamic nonlinearities on the responses of the wind-traffic-bridge system are discussed.

The Risk Analysis and Stability Estimation of Ship Collision Protection of Myodo-Gangyang Suspension Bridge (묘도-광양간 현수교의 선박충돌 방지공의 위험도 분석 및 안정성 평가)

  • Chang, Yong-Chai;Park, Ki-Chul;Kim, Kyung-Taek
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.15 no.2
    • /
    • pp.127-133
    • /
    • 2009
  • The suspension bridge between Myodo and Gwangyang is located in the main navigation channel to Gwangyang Harbor. So, there is need for the collision protection against large vessels. In this paper, the method of risk analysis and non-linear numerical analysis are conducted to consider the ship collision effects. The results of risk analysis, the annual frequency of collapse is more than the acceptable frequency 0.0001. Therefore, as a ship collision protection, island protection with concrete block quay wall is planned. The ship collision force on the pylon is less than the lateral capacity of pylon from the nonlinear numerical analysis.

  • PDF