• 제목/요약/키워드: Push-up System

검색결과 56건 처리시간 0.031초

기류 가시화기법을 이용한 방해기류 방향과 속도에 따른 푸쉬풀 후드 효율 평가 (Evaluation of Capture Efficiencies of Push-Pull Hood Systems by Cross Draft Directions and Velocities Using Smoke Visualization Technique)

  • 송세욱;김태형;하현철;강호경
    • 한국산업보건학회지
    • /
    • 제15권1호
    • /
    • pp.36-44
    • /
    • 2005
  • A push pull hood system is frequently applied to control contaminants evaporated from an open surface tank in recent years. Efficiency of push pull hood system is affected by various parameters, such as cross draft, vessel shapes, size of tanks surface, liquid temperature, and so on. Among these, velocity of cross draft might be one of the most influencing factor for determining the ventilation efficiency. To take account of the effect of cross draft velocities over 0.38m/s, a flow adjustment of ${\pm}$20% should be considered into the push and +20% into the pull flow system Although there are many studies about the efficiency evaluation of push pull hood system based on CFDs(Computational Fluid Dynamics) and experiments, there have been no reports regarding the influence of velocities and direction of cross-draft on push-pull hood efficiency. This study was conducted to investigate the influence of cross draft direction and velocities on the capture efficiency of the push-pull ventilation system. Smoke visualization method was used along with mock-up of push-pull hood systems to verify the ventilation efficiency by experiments. When the cross-draft blew from the same origins of the push flows, the efficiency of the system was in it's high value, but it was decreased significantly when the cross-draft came from the opposite side of push flows Moreover, the efficiency of the system dramatically decreased when the cross-draft of open surface tank was faster than 0.4m/s.

아크 용접 와이어의 장거리 송급을 위한 Push-pull 방식의 와이어 송급장치 개발 (Development of Push-pull Type Arc Welding Wire Feeder)

  • 윤현준;황인성;김동철;강문진;최기갑
    • Journal of Welding and Joining
    • /
    • 제31권3호
    • /
    • pp.39-43
    • /
    • 2013
  • It is difficult to feed welding wire stably, when the distance between welding wire feeder and welding torch is far enough. In order to solve this problem, arranging a extension wire feeder between them could be one of useful methods. However, the welding wire could be twisted up in the extension cable between extension and terminal wire feeders in the case that RPM of extension wire feeding motor is higher than that of terminal motor. In this study, feeding problem of normal push-pull wire feeding system occurred at low welding current range less than 250A. In order to solve the problem, two new wire feeding systems of push-pull type were introduced. Welding wire feeding tests were preformed in the range of 150A to 400A with the developed push-pull feeding system. In addition, weldability test was performed at the welding current of 200A, 300A, and 400A. The welding wire twisting problem that was observed in the normal feeding system did not occur in the new push-pull wire feeding system.

푸시업플러스(Push-up plus) 운동 시 견갑골 익상 유무에 따른 어깨안정근의 근활성도 비교 (A Comparison of the Shoulder Stabilizer Muscle Activities During Push-up Plus Between Persons With and Without Winging Scapular)

  • 박준상;전혜선;권오윤
    • 한국전문물리치료학회지
    • /
    • 제14권2호
    • /
    • pp.44-52
    • /
    • 2007
  • This study was carried out to compare the muscle activities of the shoulder stabilizers between persons with and without winging scapular during push-up plus exercise (adds the scapular protraction to the general push-up exercise). For this study, eleven males with winging scapular and eleven healthy males were recruited. Surface electromyographic (EMG) activity was recorded from the serratus anterior, upper trapezius, lower trapezius, infraspinatus, and pectoralis major while the subjects performed the push-up plus. Each push-up plus was subdivided into three phases according to the elbow position which was measured using the 3-D motion analysis system: elbow flexion (EF), elbow extension (EE), and shoulder protraction phases (SP). Two-way repeated measure ANOVA (phase ${\times}$ group) were used for statistical analysis. There was significant phase by group interaction only on the EMG composition ratio of the serratus anterior (p>.05). The EMG composition ratio of the serratus anterior was significantly higher in SP than in either EF or EE however, it was not different between winging scapular and normal groups. For both groups, the EMG composition ratio of upper trapezius, lower trapezius, and pectoralis major was significantly different across the phases of push-up plus, but the infraspinatus EMG composition ratio was not. For both groups, in EF and EE phases, the EMG composition ratio of both pectoralis major and serratus anterior were relatively higher than that of other muscles. However, in both groups, the EMG composition ratio of the serratus anterior became much more predominant than that of the pectoralis major. In addition, infraspinatus activated greater than pectoralis major. These results showed that the push-up plus exercise is effective to selectively strengthen the serratus anterior for both individuals with and without winging scapular, but not equally effective for other shoulder stabilizers.

  • PDF

체간의 나선방향운동이 운동능력에 미치는 효과 (The Effect Spiral Way Movement of a Trunk Exerts on the Movement Ability)

  • 이인학;남택길
    • 대한임상전기생리학회지
    • /
    • 제5권2호
    • /
    • pp.35-45
    • /
    • 2007
  • The purpose of this study was to examine spiral way movement of a trunk exerts on the movement ability. The details established to achieve for this article. This examination confirmed the weight, weight/height2 index, ratio of lumbar to pelvic, musculoskeletal quantity, push up for 2 minute, pitch a ball and voluntary isometric contraction with flexion and extension of knee joint of the subjects with spiral direct movement. Healthy eighteen subjects who understand fully the significance of procedure, consented to a plan, without neuromuscular disease were participated in two groups of experiment. The group were a spiral movement(9), rectilinear movement(9). Trunk movement tested 2 sessions of a spiral movement and rectilinear movement with a push up for 2 minute, 5days per a week, for the 4 weeks. This experiment tested 3 times with a sufficient rest for fatigue limitation. An analysis of the results used a paired samples t-test for difference from before and after experiment. The following results were obtained; At an internal change of the body, the musculoskeletal quantity was increased significantly to spiral movement group, but the weight was increased significantly, the musculoskeletal quantity was not significant to rectilinear movement. The movement ability evaluation for a external change was increased significantly in a push up for 2 minute, pitch a ball, isometric contraction with extension of knee joint of a spiral movement group, but a push up for 2 minute was increased significantly in a push up for 2 minute on the abdominal muscle training of a rectilinear movement group. As compared with a rectilinear movement, a spiral movement was more effect by cooperation with nerve and musculoskeletal system and an increase in movement ability was caused by learning acknowledgment, muscular reeducation. These results lead us to the conclusion that a spiral movement of trunk was more effect than a rectilinear movement, the coordination of nerve and musculoskeletal system was of importance of Multi-direction movement. Therefore, A further studies concerning the therapeutic exercise intervention and active-dynamic analysis could enhance the development of the most effect on the trunk.

  • PDF

불안정한 생산환경하에서의 시뮬레이션에 의한 JIT시스템 수행도 평가 (A Simulation Analysis of JIT System with Uncertainty Situation)

  • 박성미;남상진;김정자
    • 산업경영시스템학회지
    • /
    • 제17권32호
    • /
    • pp.155-162
    • /
    • 1994
  • The Japanese "Just-In-Time" technique reduces inventory and unnecessary factors. This technique makes the success of Japanese firms, therefore many Korean firms try to apply it to their situation. But the technique doesn't bare the same success in Korean firms. This paper, therefore, considers the different situations between Korean rim and Japanese firm, then simulates the Pull system and Push system for a multiline, multistage production system. This paper drives the different results of simulation according to variable processing times, variable demand, set-up time and shortages in Pull system and Push system using GPSS. The results show that the performance of Pull system is lower than Push system's in variable master production scheduling and variable processing times.ing times.

  • PDF

Seismic response analysis of mega-scale buckling-restrained bracing systems in tall buildings

  • Gholipour, Mohammadreza;Mazloom, Moosa
    • Advances in Computational Design
    • /
    • 제3권1호
    • /
    • pp.17-34
    • /
    • 2018
  • Tall buildings are categorized as important structures because of the large number of occupants and high construction costs. The choice of competent lateral load resisting systems in tall buildings is of crucial importance. Bracing systems have long been an economic and effective method for resisting lateral loads in steel structures. However, there are some potential adverse aspects to bracing systems such as the limitations they inflict on architectural plans, uplift forces and poor performances in compression. in order to eliminate the mentioned problems and for cost optimization, in this paper, six 20-story steel buildings and frames with different types of bracing, i.e., conventional, mega-scale and buckling-restrained bracing (BRB) were analyzed. Linear and modal push-over analyses were carried out. The results pointed out that Mega-Scale Bracing (MSB) system has significant superiority over the conventional bracing type. The MSB system is 25% more economic. Some other advantages of MSB include: up to 63% less drift ratio, up to 38% better performance in lateral displacement, up to 100% stiffer stories, and about 50% smaller uplift forces. Moreover, MSB equipped with BRB attests even a better seismic behavior in the aforementioned parameters.

AC 모듈형 태양광 모듈 집적형 컨버터를 위한 소프트 스위칭 DC-DC 컨버터 (Soft Switching DC-DC Converter for AC Module Type PV Module Integrated Converter)

  • 윤선재;김영호;정용채;원충연
    • 전력전자학회논문지
    • /
    • 제18권3호
    • /
    • pp.247-255
    • /
    • 2013
  • In this paper, a soft switching DC-DC converter for AC module type photovoltaic (PV) module integrated converter is proposed. A push-pull converter is suitable for a low voltage PV AC module system because the step-up ratio of a high frequency transformer is high and the number of primary side switches is relatively small. However, the conventional push-pull converters do not have high efficiency because of high switching losses by hard switching and transformer losses (copper and iron losses) by high turns-ratio of the transformer. In the proposed converter, primary side switches are turned on at zero voltage switching (ZCS) condition and turned off at zero current switching (ZVS) condition through parallel resonance between secondary leakage inductance of the transformer and a resonant capacitor. Therefore the proposed push-pull converter decreases the switching loss using soft switching of the primary switches. Also, the turns-ratio of the transformer can be reduced by half using a voltage-doubler of secondary side. The theoretical analysis of the proposed converter is verified by simulation and experimental results.

3지 교차로에서 보행자 교통량에 따른 보행자작동신호기를 이용한 신호제어효율에 관한 분석 (An Analysis on Signal Control Efficiency in a Three-Leg Intersection Adopting Pedestrian Push-Button System Following Pedestrian volume)

  • 김응철;조한선;정동우;김형수
    • 한국도로학회논문집
    • /
    • 제11권3호
    • /
    • pp.121-128
    • /
    • 2009
  • 본 연구는 기존 정주기식 신호제어로 인하여 비효율적으로 운영되고 있는 3지 교차로의 문제점을 보완하는 방안으로써 반감응 신호제어를 기본으로 하고 보행자작동신호기를 사용하는 신호운영방식의 효율성을 분석하였다. 반감응 신호제어의 경우 부도로에 교통량이 적을 때 주도로의 교통소통을 원활히 하여 교차로 내 지체를 감소시킬 수 있으며, 보행자작동신호기는 보행자가 없음에도 불구하고 보행자 신호를 작동시켜 발생하는 불필요한 대기시간을 줄일 수 있는 장점을 가지고 있다. 위의 두 가지의 장점을 모았을 경우 기존의 정주기식 신호제어와 반감응식 신호제어에 비하여 얼마나 효과가 있는지 미시적 시뮬레이션 프로그램인 VISSIM을 사용하여 정량화된 차량당 평균지체 감소의 정도를 분석하고자 하였다. 본 연구는 인천의 1개 3지 교차로를 대상으로 현장조사를 실시하였고 각각의 신호제어 방식에 따라서 보행자 교통량을 변화시켜 민감도 분석을 실시하였다. 시나리오 별 분석을 통하여 차량당 평균지체시간을 비교한 결과, 대상교차로는 정주기식 신호제어에 비하여 보행자작동신호기를 이용한 신호제어방식이 최소 3.7초(10%), 최대 6초(16%)의 감소효과를 나타내었으며 반감응식 신호제어와의 비교에서는 보행자교통량이 측정교통량의 20% 이하일때보다 효율적인 것으로 나타났다.

  • PDF

관절경적 후방십자인대 재건술에 있어서 Transtibial Two Tunnel방법과 Modified Tibial Inlay방법의 비교 (The Results of Posterior Cruciate Ligament Reconstruction. -Transtibial Two Tunnel Technique vs. Modified Tibial Inlay Technique-)

  • 정영복;태석기;염재광;구본호
    • 대한관절경학회지
    • /
    • 제2권2호
    • /
    • pp.135-140
    • /
    • 1998
  • From 1989 to 1994, authors have reconstructed the posterior cruciate ligament(PCL) in 51 knees with an autogenous central one-third of the patellar tendon by transtibial two tunnel technique, but there were not a few cases of unfavorable results. So from January 1995, we have reconstructed the PCL deficient knees by "modified tibial inlay technique" to avoid the grafted tendon abrasion at the posterior opening of the tibial tunnel(killer turn). Purpose of this study was to compare the results of two surgical techniques and what its advantages and disadvantages are. We could follow up 39 cases of transtibial two tunnel techique group(group A) more than one year, average being 23.7 months and 21 cases of modified tibial inlay technique group(group B) more than 12 months, average being 14.7 months. The clinical results were evaluated by the OAK knee scoring system ($M{\ddot{u}}ller$'s criteria) and the posteror stress roentgenography (push view) with Telos stress device compared with the uninjured knees. The arthroscopic second-look findings were also evaluated. In group A : The $M{\ddot{u}}ller$'s knee score was average 80.1 points, the posteror displacement in push view was average 4.4mm at the last follow up. There were 17 cases(44%) of unfavorable results which showed unstable posterior displacement more than 4mm compared with the uninjured knee in push view. Among the 19 cases of arthroscopic second look examinations, nearly normal PCL appearances of the grafted tendons were noted only in 9 cases(47%). In group B : The $M{\ddot{u}}ller$'s knee score was average 86.7 points, the posterior displacemnet in push view was average 3.6mm at the last follow up. There were 5 cases(23.8%) of unfavorable results which showed unstable posterior displacement more than 4mm compared with the uninjured knee in push view but 4 out of 5 cases showed 6mm posterior displacement in push views. Among the 7 cases of arthroscopic second-look examinations, 6 cases(86%) showed nearly normal PCL appearances of the grafted tendons. In modified tibial inlay technique of PCL reconstruction, it was easier to pull out the BPTB and in cases of remained laxed meniscofemoral ligament it was easier to preserve the remained structures than transtibial two tunnel technique. We expect the "modified tibial inlay technique" may solve the problem of grafted patellar tendon abrasion at the posterior orifice of tibial tunnel and may contribute to the successful PCL reconstruction.

  • PDF

Light-gauge composite floor beam with self-drilling screw shear connector: experimental study

  • Erdelyi, Szilvia;Dunai, Laszlo
    • Steel and Composite Structures
    • /
    • 제9권3호
    • /
    • pp.255-274
    • /
    • 2009
  • This paper presents an experimental study of a newly developed composite floor system, built up from thin-walled C-profiles and upper concrete deck. Trapezoidal sheeting provides the formwork and the fastening of the sheet transmits the shear forces between the C-profiles and the deck. The modified formation of the standard self-drilling screw in the beam-to-sheet connection is applied as shear connector. Push-out tests are completed to study the composite behaviour of the different connection arrangements. On the basis of the test results the behaviour is characterized by the observed failure modes. The design values of the connection stiffness and strength are calculated by the recommendation of Eurocode 4. In the next phase of the experimental study six full-scale composite beams are tested. The global geometry is based on the proposed geometry of the developed floor system. The applied shear connections are selected as the most efficient arrangements obtained from the push-out tests. The experimental behaviour of the composite beams are discussed and evaluated. As a conclusion of the experimental study the Eurocode 4 plastic design method is validated for the developed composite floor.