• 제목/요약/키워드: Pure shear loading

검색결과 43건 처리시간 0.021초

Tension-Shear Experimental Analysis and Fracture Models Calibration on Q235 Steel

  • Huang, Xiaogang;Zhou, Zhen;Zhu, Yazhi;Zhu, Dongping;Lu, Lu
    • 국제강구조저널
    • /
    • 제18권5호
    • /
    • pp.1784-1800
    • /
    • 2018
  • Tension-shear loading is a common loading condition in steel structures during the earthquake shaking. To study ductile fracture in structural steel under multiple stress states, experimental investigations on the different fracture mechanisms in Chinese Q235 steel were conducted. Different tension-shear loading conditions achieved by using six groups of inclined notch butterfly configurations covering pure shear, tension-shear and pure tension cases. Numerical simulations were carried out for all the specimens to determine the stress and strain fields within the critical sections. Two tension-shear fracture models were calibrated based on the hybrid experimental-numerical procedure. The equivalent fracture strain obtained from the round bar under tensile loading was used for evaluating these two models. The results indicated that the tension-shear criterion as a function of the shear fracture parameter had better performance in predicting the fracture initiation of structural steel under different loading conditions.

순수 모드 II하중 하에서의 SPS 시험편의 연성파괴 특성에 관한 연구 (Ductile Fracture Behaviour of SPS Specimen Under Pure Mode II Loading)

  • 오동준
    • 대한기계학회논문집A
    • /
    • 제25권2호
    • /
    • pp.289-295
    • /
    • 2001
  • The aim of this study is to investigate the ductile fracture behaviour under pure Mode II loading using A533B pressure vessel steel. Single punch shear(SPS) test was performed to obtain the J-R curve under pure Mode II loading which was compared with that of the Model I loading. Simulation using Rousellier Ductile Damage Theory(RDDT) was carried out with 4-node quadrilateral element(L(sub)c=0.25mm). For the crack advance, the failed element removal technique was adopted with a $\beta$ criterion. Through the $\beta$ value tuning-up procedures, $\beta$(sub)crit(sup)II was determined as 1.5 in contrast with $\beta$(sub)crit(sup)I=5.5. In conclusion, it was found that the J-R curve under Mode II loading was located at lower part than that under Mode I loading obtained from the previous study and that the $\beta$ values strongly depended on the loading type. In addition, the predicted result using RDDT showed a good agreement with the SPS experimental one under pure Mode II loading.

SC구조 평판의 면내전단내력 평가 (Evaluation of Steel Plate Reinforced Concrete Panels under In-plane Shear)

  • 이명재;이현욱;진성찬
    • 한국강구조학회 논문집
    • /
    • 제20권4호
    • /
    • pp.571-581
    • /
    • 2008
  • 최근 공기단축, 인건비절감 및 시공성 향상을 위한 간편한 시공법으로 그 구조적 성능이 우수한 SC구조시스템이 제안되었다. 이 연구에서는 SC구조 기술의 전반적인 연구의 일환으로 기본적인 SC구조 면내 전단력에 대한 거동특성을 파악함과 동시에 평판에 순수면내전단력을 가력하는 방법에 대해 타당성 검토를 병행한다. 특히 SC구조의 거동특성 중 순전단응력상태 및 축력과 전단응력이 동시에 작용하는 상황에서 면내전단에 대한 내력과 변형 등 기본적 역학특성 및 구조적 성능을 파악하고 평판 면내전단가력 방법을 제안하는 것이다. SC구조 평판전단내력실험을 통해 강재와 콘크리트의 일체 거동을 통한 평판의 내력 상승 및 축력의 유무에 따른 내력 상승을 확인하였으며, 전단력에 의한 평판의 파괴 양상을 파악하였다. 또한 평판에 순수 전단력만을 가력하기 위한 4힌지 프레임에 의한 평판전단내력 실험방법의 가능성 또한 확인하였다.

Deformation of a rectangular plate with an arbitrarily located circular hole under in-plane pure shear loading

  • Yang, Yeong-Bin;Kang, Jae-Hoon
    • Structural Engineering and Mechanics
    • /
    • 제60권2호
    • /
    • pp.351-363
    • /
    • 2016
  • Exact solutions for stresses, strains, displacements, and the stress concentration factors of a rectangular plate perforated by an arbitrarily located circular hole subjected to in-plane pure shear loading are investigated by two-dimensional theory of elasticity using the Airy stress function. The hoop stresses, strains, and displacements occurring at the edge of the circular hole are computed and plotted. Comparisons are made for the hoop stresses and the stress concentration factors from the present study and those from a rectangular plate with a circular hole under uni-axial and bi-axial uniform tensions and in-plane pure bending moments on two opposite edges.

Dynamic characteristics of combined isolation systems using rubber and wire isolators

  • Lee, Seung-Jae;Truong, Gia Toai;Lee, Ji-Eon;Park, Sang-Hyun;Choi, Kyoung-Kyu
    • Nuclear Engineering and Technology
    • /
    • 제54권3호
    • /
    • pp.1071-1084
    • /
    • 2022
  • The present study aims to investigate the dynamic properties of a novel isolation system composed of separate rubber and wire isolators. The testing program comprised pure compressive, pure-shear, compressive-stress dependence, and shear-strain dependence tests that used full-scale test specimens according to ISO 22762-1. A total of 22 test specimens were fabricated and investigated. Among the tests, the pure compressive test was a destructive test that reached up to the failure stage, whereas the others were nondestructive tests before the failure stage. Similar to the pure-shear test, at each compressive-stress level in the compressive dependence test or at each shear-strain level in the shear-strain dependence test, the cyclic loading was conducted for three cycles. In the nondestructive tests, examination of the dynamic shear properties in the X-direction was independent of the Y-direction. The test results revealed that the increase in the shear strain increased the energy dissipation but decreased the damping ratio, whereas the increase in the compressive stress increased the damping ratio. In addition, a macro model was developed to simulate the load-displacement response of the isolation systems, and the prediction results were consistent with the experimental results.

틸팅차량용 차체의 Hybrid 복합재 접합체결부의 정적 및 피로 파괴 평가 (Static and Fatigue Fracture Assessment of Hybrid Composite Joint for the Tilting Car Body)

  • 정달우;김정석;서승일;조세현;최낙삼
    • 대한기계학회논문집A
    • /
    • 제31권2호
    • /
    • pp.166-173
    • /
    • 2007
  • Fatigue fracture behavior of a hybrid bolted joint was evaluated in comparison to the case of static fracture. Two kinds of specimens were fabricated for the mechanical tests; a hybrid bolted joint specimen for the shear test and a hybrid joint part specimen applied in the real tilting car body for the bending test. Characteristic fracture behaviors of those specimens under cyclic toads were obviously different from the case under static loads. For the hybrid bolted joint specimen, static shear loading caused the fracture of the bolt body itself in a pure shear mode, whereas cyclic shear loading brought about the fracture at the site of local tensile stress concentration. For the hybrid joint part specimen, static bend loading caused the shear deformation and fracture in the honeycomb core region, while cyclic bend loading did the delamination along the interface between composite skin and honeycomb core layers as well as the fracture of welded joint part. Experimental results obtained by static and fatigue tests were reflected in modifications of design parameters of the hybrid joint structure in the real tilting car body.

Behavior of tunnel form buildings under quasi-static cyclic lateral loading

  • Yuksel, S. Bahadir;Kalkan, Erol
    • Structural Engineering and Mechanics
    • /
    • 제27권1호
    • /
    • pp.99-115
    • /
    • 2007
  • In this paper, experimental investigations on the inelastic seismic behavior of tunnel form buildings (i.e., box-type or panel systems) are presented. Two four-story scaled building specimens were tested under quasi-static cyclic lateral loading in longitudinal and transverse directions. The experimental results and supplemental finite element simulations collectively indicate that lightly reinforced structural walls of tunnel form buildings may exhibit brittle flexural failure under seismic action. The global tension/compression couple triggers this failure mechanism by creating pure axial tension in outermost shear-walls. This type of failure takes place due to rupturing of longitudinal reinforcement without crushing of concrete, therefore is of particular interest in emphasizing the mode of failure that is not routinely considered during seismic design of shear-wall dominant structural systems.

Effect of spiral reinforcement on flexural-shear-torsional seismic behavior of reinforced concrete circular bridge columns

  • Belarbi, Abdeldjelil;Prakash, Suriya;You, Young-Min
    • Structural Engineering and Mechanics
    • /
    • 제33권2호
    • /
    • pp.137-158
    • /
    • 2009
  • This paper investigates the behavior of reinforced concrete (RC) circular columns under combined loading including torsion. The main variables considered in this study are the ratio of torsional moment to bending moment (T/M) and the level of detailing for moderate and high seismicity (low and high transverse reinforcement/spiral ratio). This paper presents the results of tests on seven columns subjected to cyclic bending and shear, cyclic torsion, and various levels of combined cyclic bending, shear, and torsion. Columns under combined loading were tested at T/M ratios of 0.2 and 0.4. These columns were reinforced with two spiral reinforcement ratios of 0.73% and 1.32%. Similarly, the columns subjected to pure torsion were tested with two spiral reinforcement ratios of 0.73% and 1.32%. This study examined the significance of proper detailing, and spiral reinforcement ratio and its effect on the torsional resistance under combined loading. The test results demonstrate that both the flexural and torsional capacities are decreased due to the effect of combined loading. Furthermore, they show a significant change in the failure mode and deformation characteristics depending on the spiral reinforcement ratio. The increase in spiral reinforcement ratio also led to significant improvement in strength and ductility.

부분적(部分的)인 균일전단하중(均一傳達荷重)을 받는 평판(平板)에서의 응력분포(應力分布) (Stress Distributions in a Plate due to Shear Loading Uniformly Distributed on the End Portions of its Side Boundary.)

  • 김효철
    • 대한조선학회지
    • /
    • 제7권1호
    • /
    • pp.37-44
    • /
    • 1970
  • The plate under shear loading umformly distributed on the end portions of its side boundary was considered. Infinite hyperbolic serieses and Fourier serieses were combined as a stress function and from which exact solutions for the 15 cases for the parameters of b/L=0.25, 0.5, 1.0 and l/L=0.2, 0.4, 0.6, 0.8, 1.0 are obtained. In each cases the first 5 terms of the infinite series at the 36 points as shown in Fig. 3. The results are presented in Fig. 4-1, 4-2, and 4-3. The conclusions are as follows: 1) The stresses ${\sigma}_x$ increase very slightly as $\chi$ increases in the range of 0<x<L-l 2) When the parameters satisfy the conditions b/L<0.25 and l/L<0.2, the stresses in the region of 0<x<L-l can be obtained by replacing the uniform shear loading by the equivalent uniform shear loading by the equivalent uniform tensile force and pure bending moment at x=l. 3) The stress ${\sigma}_y$ is negligible throughout the region. 4) When the parameter b/L varies, the stresses ${\sigma}_x$ and u vary as L/b, while strain $\upsilon$ varies as $(L/b)^2$.

  • PDF

Experimental study of bearing capacity of strip footing on sand slope reinforced with tire chips

  • Keskin, Mehmet Salih;Laman, Mustafa
    • Geomechanics and Engineering
    • /
    • 제6권3호
    • /
    • pp.249-262
    • /
    • 2014
  • Tire chips and tire chips-soil mixtures can be used as alternative fill material in many civil engineering applications. In this study, the potential benefits of using tire chips as lightweight material to improve the bearing capacity and the settlement behavior of sand slope was investigated experimentally. For this aim, a series of direct shear and model loading tests were conducted. In direct shear tests, the effect of contents of the tire chips on the shear strength parameters of sand was investigated. Different mixing ratios of 0, 5, 10, 15 and 20% by volume were used and the optimum mixing ratio was obtained. Then, laboratory model tests were performed on a model strip footing on sand slope reinforced with randomly distributed tire chips. The loading tests were carried out on sand slope with relative density of 65% and the slope angle of $30^{\circ}C$. In the loading tests the percentage of tire chips to sand was taken as same as in direct shear tests. The results indicated that at the same loading level the settlement of strip footing on sand-tire chips mixture was about 30% less than in the case of pure sand. Addition of tire chips to sand increases BCR (bearing capacity ratio) from 1.17 to 1.88 with respect to tire chips content. The maximum BCR is attained at tire chips content of 10%.