• Title/Summary/Keyword: Pupil Size

Search Result 106, Processing Time 0.03 seconds

Approach to pupillary abnormalities via anatomical pathways (동공 질환의 접근: 해부학적 경로를 통해서)

  • Kim, Sung-Hee
    • Journal of Yeungnam Medical Science
    • /
    • v.34 no.1
    • /
    • pp.11-18
    • /
    • 2017
  • The pupillary size and movement are controlled dynamically by the autonomic nervous system; the parasympathetic system constricts the iris, while the sympathetic system dilates the iris. Under normal conditions, these constrictions and dilations occur identically in both eyes. Asymmetry in the pupillomotor neural input or output leads to impaired pupillary movement on one side and an unequal pupil size between both eyes. Anisocoria is one of the most common signs in neuro-ophthalmology, and the neurological disorders that frequently cause anisocoria include serious diseases, such as vascular dissection, fistula, and aneurysm. A careful history and examination can identify and localize pupillary disorders and provide a guide for appropriate evaluations.

Study of UV-cut Effect by Luminance and Size of pupil in lens (Luminance와 동공크기 변화에 따른 렌즈에서 UV 차단효과 연구)

  • Kim, Yong-Geun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.17-21
    • /
    • 2001
  • We analyzed the luminance in the visual light region and the size of pupil by the luminance to estimate an UV-A line cut efficiency in the lens. The size of pupil by the luminance(L) was given by ${\Phi}=d-e{\cdot}tanh(f{\cdot}logL)$ and the transmittance efficiency value of a size of pupil was given by $T_r(r)=1-gr^2+hr^4$. We derived the absolute cut efficiency value ${\alpha}$ and the exclusion index $b=(1-{\alpha}){\times}100%$ about the UV-A in the $320{\sim}400nm$ regions. The ${\alpha}$ and b values were obtained respectively 0.018, 0.31, 0.273, 0.153 and 98, 69, 72, 85% of Uv-cut Lens, CR-39, red color and blue color.

  • PDF

Concealed information test using ERPs and pupillary responses (ERP와 동공 반응을 이용한 숨긴정보검사)

  • Eom, Jin-Sup;Park, Kwang-Bai;Sohn, Jin-Hun
    • Science of Emotion and Sensibility
    • /
    • v.15 no.2
    • /
    • pp.259-268
    • /
    • 2012
  • In a P300-based concealed information test (P300 CIT), the result of the test is greatly affected by the value of the probe stimulus. With a probe stimulus of low value, the detection rate decreases. The aim of this study was to determine whether the pupil-based concealed information test (Pupil CIT) could be used in addition to the P300 CIT for the probes of low value. Participants were told to choose one card from a deck of five cards (space 2, 3, 4, 5, 6), Then a P300 CIT and a Pupil CIT for the selected card were administered. P300s were measured at 3 scalp sites (Fz, Cz, and Pz), and the pupil sizes of left and right eyes were recorded. The P300 amplitude measured at Fz, Cz, and Pz was significantly different between the probe and irrelevant stimuli. And, in the Pupil CIT, the pupil size was also different between the two stimuli for both eyes. The detection rates of the P300 CIT were 44% at Fz and Cz sites and 36% at Pz site. And the detection rates of the Pupil CIT were 52% for the left eye and 60% for the right eye. There is a trend that the detection rate of the Pupil CIT was higher than that of the P300 CIT, but the difference didn't reach significance partly because of the relatively small sample size. The correlation between the decision based on the P300 CIT and that based on the Pupil CIT was not significant. As a conclusion, it is recommended to use a Pupil CIT instead of a P300 CIT when the value of the probe is low. And a combination of the measures may be superior to either one of them in detection rate.

  • PDF

Emotion Classification Method Using Various Ocular Features (다양한 눈의 특징 분석을 통한 감성 분류 방법)

  • Kim, Yoonkyoung;Won, Myoung Ju;Lee, Eui Chul
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.10
    • /
    • pp.463-471
    • /
    • 2014
  • In this paper, emotion classification was performed by using four ocular features extracted from near-infrared camera image. According to comparing with previous work, the proposed method used more ocular features and each feature was validated as significant one in terms of emotion classification. To minimize side effects on ocular features caused by using visual stimuli, auditory stimuli for causing two opposite emotion pairs such as "positive-negative" and "arousal-relaxation" were used. As four features for emotion classification, pupil size, pupil accommodation rate, blink frequency, and eye cloased duration were adopted which could be automatically extracted by using lab-made image processing software. At result, pupil accommodation rate and blink frequency were statistically significant features for classification arousal-relaxation. Also, eye closed duration was the most significant feature for classification positive-negative.

The Changes in Contrast Sensitivity and Glare Sensitivity when Wearing Circle Contact Lenses after the Refractive Surgery (시력교정술 후 써클콘택트렌즈 착용 시 대비감도 및 눈부심감도 변화)

  • Kwon, Ki Nam;Park, Sang Hee;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.1
    • /
    • pp.23-34
    • /
    • 2016
  • Purpose: In the present study, the effect of circle contact lenses wear on contrast sensitivity and glare sensitivity in a refractive surgery group was investigated. Methods: The contrast sensitivity and glare sensitivity were evaluated using by CGT-1000 for a non-refractive surgery group as control group(40 eyes) and a refractive surgery group(30 eyes) applied plano circle contact lenses, and pupil size was also measured. The correlation between contrast/glare sensitivity and the pupil size was analyzed. Results: In the refractive surgery group, contrast sensitivity in the range of high spatial frequency decreased with wearing circle contact lenses, and amount of decrease for the refractive surgery group was larger than for the control group. The correlation between pupil size and the change of contrast sensitivity was decreased by wearing circle contact lenses, and the correlation was lower in the refractive surgery group than the control group. Furthermore, the wear of circle contact lenses affected on glare sensitivity. In analyzing the change of glare sensitivity by pupil size, the glare was larger in the refractive surgery group than control group. Circle contact lenses in refractive surgery group were not fitted on the center of cornea. Conclusions: In the present study, it is suggested that the sufficient understanding and consideration about the decrease of contrast sensitivity and the increase of glare by wearing circle contact lenses after the refractive surgery is necessary.

Pupil Data Measurement and Social Emotion Inference Technology by using Smart Glasses (스마트 글래스를 활용한 동공 데이터 수집과 사회 감성 추정 기술)

  • Lee, Dong Won;Mun, Sungchul;Park, Sangin;Kim, Hwan-jin;Whang, Mincheol
    • Journal of Broadcast Engineering
    • /
    • v.25 no.6
    • /
    • pp.973-979
    • /
    • 2020
  • This study aims to objectively and quantitatively determine the social emotion of empathy by collecting pupillary response. 52 subjects (26 men and 26 women) voluntarily participated in the experiment. After the measurement of the reference of 30 seconds, the experiment was divided into the task of imitation and spontaneously self-expression. The two subjects were interacted through facial expressions, and the pupil images were recorded. The pupil data was processed through binarization and circular edge detection algorithm, and outlier detection and removal technique was used to reject eye-blinking. The pupil size according to the empathy was confirmed for statistical significance with test of normality and independent sample t-test. Statistical analysis results, the pupil size was significantly different between empathy (M ± SD = 0.050 ± 1.817)) and non-empathy (M ± SD = 1.659 ± 1.514) condition (t(92) = -4.629, p = 0.000). The rule of empathy according to the pupil size was defined through discriminant analysis, and the rule was verified (Estimation accuracy: 75%) new 12 subjects (6 men and 6 women, mean age ± SD = 22.84 ± 1.57 years). The method proposed in this study is non-contact camera technology and is expected to be utilized in various virtual reality with smart glasses.

Intracameral Epinephrine Injection after Phacoemulsification on Pupil Dilation during Phacovitrectomy for Proliferative Diabetic Retinopathy (유리체절제술과 수정체유화술 동시 수술 시 백내장수술 후 앞방내 에피네프린 주입과 동공 확대)

  • Kim, Sangbum;Park, Jongyeop;Shin, Jaeryung;Lee, Seungwoo
    • Journal of The Korean Ophthalmological Society
    • /
    • v.59 no.12
    • /
    • pp.1137-1141
    • /
    • 2018
  • Purpose: We explored the mydriatic effects of injected intracameral epinephrine after phacoemulsification (PE) combined with phacovitrectomy to treat proliferative diabetic retinopathy (PDR). Methods: We enrolled 96 patients (96 eyes) who underwent phacovitrectomy to treat PDR; we used ImageJ software to measure pupil sizes and the ratios of pupil to cornea area (PCA) before and after PE and after pars plana vitrectomy (PPV). We compared pupil sizes between those who received intracameral epinephrine (0.001% w/v) after PE but before PPV (study group, 46 eyes) and patients not so treated (control group, 50 eyes). Results: The PCA ratios of the study group were $0.52{\pm}0.11$ before PE, $0.43{\pm}0.12$ after PE, and $0.51{\pm}0.11$ after PPV, respectively. Changes in pupil size were significant (p < 0.001, p < 0.001 respectively). The PCA ratios of the control group were $0.52{\pm}0.10$ before PE, $0.39{\pm}0.15$ after PE, and $0.43{\pm}0.15$ after PPV, respectively. Changes in pupil size after PE were significant (p = 0.011) but the change after PPV was not (p = 0.056). Conclusions: Intracameral epinephrine given after PE but before PPV effectively dilates the pupils during phacovitrectomy to treat PDR.

Red-Eye Removal Using an Inpainting Method (인페인팅 기법을 이용한 적목현상 제거)

  • Yoo, Seung-Hwan;Park, Rae-Hong
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.365-366
    • /
    • 2007
  • In this paper, a novel correction method of red-eye effect is proposed. Conventional methods simply reduce red components in red-eye regions, not considering the expanded size of a pupil, thus the correction results can be unnatural. In the proposed method, an exemplar-based inpainting method is used for reducing the pupil region and filling the iris texture instead. Experimental results show that the proposed method is effective and its correction results look more natural than those of conventional methods.

  • PDF

Realistic Expression Factors According to Visual Presence in Terms of Iris color and Pupil Accommodation of Virtual Avatar (가상 아바타의 홍채색과 동공 조절에 따른 시각적 실재감에 대한 실감표현요소)

  • Won, Myoung Ju;Park, Sang-In;Lee, Eui Chul;Whang, Min-Cheol
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.4
    • /
    • pp.1-8
    • /
    • 2014
  • The virtual avatar is a principal way as media for communicating language and affective feelings in virtual environment. As similar purpose, this study evaluates user's visual feeling according to the changes of iris color and pupil size of virtual avatar which is considered as new factors for representing realistic avatar. Virtual avatars were configured by pupil accommodation and iris color(green, brown). After presenting above image to 32 participants, a questionnaire(18 items) based on previous studies was created, and reported as a 5-point scale. Experimental result showed that the case of adopting pupil accommodation induced more realistic visual feeling of subjects. This result can be regarded as a basis for designing realistic virtual avatar by confirming the effectiveness of pupil accommodation of avatar in terms of representing visual presence.

Pupil plane wavefront sensing with a static pyramidal prism: Simulation and preliminary evaluation

  • Lee, Jun-Ho;Doel, A.P.;Walker, D.D.
    • Journal of the Optical Society of Korea
    • /
    • v.4 no.1
    • /
    • pp.1-6
    • /
    • 2000
  • Adaptive optics(AO) removes or compensates the distortion caused by a turbulent atmosphere or medium. A wavefront sensormeasures the distortion, on which the correction of AO is based. A new idea of pupil plane wavefront sensing, which consists of a relay lens and a pyramidal-shaped prism, was previously proposed. This paper reviews the idea of pupil wavefrontsensing and presents prism, was previously proposed. The simulation shows that pupilwavefront sensing provides full wavefront sensing when the intensity peak of PSF is located within half of the Airy radius from the apex of the sensor. Adding to this, the sensor is shown to have optimum sensor output with a finite bevel size of the pyramidal prism.