• 제목/요약/키워드: Punching shear strength

검색결과 131건 처리시간 0.023초

슬래브-기둥 접합부의 뚫림 전단강도에 대한 래티스 보강상세의 영향 (Effects of details of lattice reinforcement for punching shear strength of slab-column connections)

  • 김유니;박홍근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.17-20
    • /
    • 2006
  • A flat plate-column connection is susceptible to brittle punching shear failure, which may result in the necessity of shear reinforcement. In previous, experimental tests were performed to study the capacity of slab-column connections strengthened with various shear reinforcement, and the capacity of the specimens with lattice reinforcement are superior to the others. In present study, to study for effects of details of lattice reinforcement, experimental studies was performed. Main parameters are the amount of lattice shear reinforcement, arrangement of lattice and the effect of flexural re-bar. And capacity of the specimen with small amount of lattice reinforcement was higher than the capacity of other shear reinforcement.

  • PDF

리브 형상을 갖는 반단면 프리캐스트 바닥판의 피로 안전성 평가 (Fatigue Safety Evaluation of the Half-Depth Precast Deck with RC Rib Panel)

  • 황훈희
    • 한국안전학회지
    • /
    • 제34권5호
    • /
    • pp.103-110
    • /
    • 2019
  • In order to reduce the accidents occurring at construction sites, it is necessary to approach with harmonious measures considering various aspects such as systems, training, facilities, and protection equipments. Suggestion of safe construction method can be a good alternative. In the previous study, the half-depth precast deck with RC rib panel was proposed as an alternative method for safe bridge deck construction, and the performance required by the design code was verified through a four-point bending test. But the actual bridge deck is subjected to the repetitive action of the wheel load rather than the bending condition due to the four-point load. In this study, fatigue test was performed by repeating the wheel load $2{\times}10^6$ cycles to verify the safety of the half-depth precast deck with RC rib panel under actual conditions. As a result, fatigue effect due to repetition of wheel load was not significant in terms of serviceability such as crack width and deflection. In the residual strength test conducted after the fatigue test, the half-depth precast deck with RC rib panel failed by punching shear which is typical failure mode of bridge decks and the residual strength was similar to the punching strength of the RC and PSC bridge decks in spite of the fatigue effects.

80 MPa급 고강도 콘크리트를 적용한 RC 바닥판의 피로 성능 평가 (Evaluation of Fatigue Performance of RC Deck Slabs by 80 MPa High-Strength Concrete)

  • 배재현;황훈희;유동민;박성용
    • 한국안전학회지
    • /
    • 제32권4호
    • /
    • pp.66-72
    • /
    • 2017
  • Recently, the use of high-strength concrete is increasing due to the trend of constructing high-rise and long span structures. The benefit of using the high-strength concrete is that it increases the durability and strength while it reduces the cross-sectional area of the bridge deck slabs. Moreover, it offers more safety as these bridge deck slabs applying high-strength requires strict structural performance verification. In this study, the fatigue performance of the bridge deck slabs applying 80 MPa high-strength concrete was verified through various experiments. The experimental results showed that the specimens satisfy the conditions of flexural strength, punching shear strength, deflection and cracking. In conclusion, the bridge deck slabs designed by 80 MPa high-strength concrete are enough safe despite of its low thickness.

2방향 슬래브의 펀칭전단성능 향상을 위한 고성능 철근의 적용 (Application of High-Performance Steels to Enhance the Punching Shear Capacity of Two-Way Slabs)

  • 양준모;신현오;이주하;윤영수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권2호
    • /
    • pp.161-169
    • /
    • 2011
  • 본 연구에서는, 철근 밀집 감소, 노무비 및 보수 보강비 절약, 향상된 부식 저항성, 공기 단축 등의 장점을 가지고 있는 고성능 철근으로 휨 보강된 이방향 슬래브를 제작하고 구조실험을 실시하였다. 상부 휨철근비, 기둥 인접부 휨철근의 집중배근, 강섬유 보강 콘크리트의 타설을 변수로 하여 실험하였고, 펀칭 전단강도 및 균열후 강성을 일반 철근 및 GFRP bar로 휨 보강된 슬래브의 펀칭 전단실험 결과와 비교하였다. 또한, 휨철근의 변형률 분포 및 균열제어 효과 등을 비교, 분석하였고, 휨철근비 계산을 위한 유효폭 산정 방법을 검토하였다. 고성능 철근의 사용으로 펀칭 전단강도가 향상되었고, 휨 철근량을 감소시킬 수 있었다. 기둥 인접부 휨철근의 집중배근을 통해 철근비의 감소 때문에 작아진 강성을 회복시킬 수 있었고, 훌륭한 변형률 분포 및 균열제어 효과를 나타내었다. 또한, 기둥 인접부에 대한 강섬유 보강 콘크리트의 타설은 펀칭 전단강도의 증가와 균열 제어에 탁월한 효과를 보였다. 휨철근비 산정을 위한 유효폭은 기둥면으로부터 슬래브 두께의 2배 이상으로 확대하는 것이 합리적이라 판단된다.

고강도 콘크리트를 적용한 RC 바닥판의 정적 성능 평가 (Evaluation of Structural Performance of RC Deck Slabs by High-Strength Concrete)

  • 배재현;황훈희;박성용;조근희
    • 한국안전학회지
    • /
    • 제31권3호
    • /
    • pp.89-95
    • /
    • 2016
  • Lately, the high-strength concrete is often used to increase the lifespan of bridges. The benefits of using the high-strength concrete are that it increases the durability and strength. On the contrary, it reduces the cross-section of the bridges. This study conducted structural performance tests of the bridge deck slabs applying high-strength concrete. As result of the tests, specimens of bridge deck slabs were destroyed through punching shear. Moreover, the tests exposed that the high-strength concrete bridge deck slabs satisfy the flexural strength and the punching shear strength at ultimate limit state(ULS). Also, limiting deflection of the concrete fulfilled serviceability limit state(SLS) criteria. These results indicated that the bridge deck slabs designed by high-strength concrete were enough to secure the safety factor despite of its low thickness.

슬래브-기둥 접합부에 대한 전단강도모델 (Shear Strength Model for Slab-Column Connections)

  • 최경규;박홍근;김혜민
    • 콘크리트학회논문집
    • /
    • 제22권4호
    • /
    • pp.585-593
    • /
    • 2010
  • 선행연구에서 제안된 변형률기반 전단강도모델에 근거하여, 슬래브-기둥 내부 및 외부접합부의 직접뚫림전단강도와 불균형휨모멘트강도를 정확하게 평가할 수 있는 강도모델을 개발하였다. 슬래브-기둥 접합부는 뚫림전단파괴에 앞서서 휨균열에 의해서 손상을 받으므로, 이 연구에서는 위험단면의 압축대에서 대부분의 전단저항이 발휘된다고 가정하였다. 슬래브 휨모멘트에 의해서 유발되는 압축수직응력이 콘크리트 압축대의 전단강도에 미치는 영향을 고려하기 위하여, 다축응력 상태에 대한 콘크리트 재료파괴기준을 이용하였다. 그 결과 위험단면의 전단성능이 휨손상의 정도에 따라서 정의되었다. 외부접합부는 비대칭적인 위험단면을 가지고 있으므로 하중재하방향을 고려하여 휨모멘트강도를 정의하였다. 실험 결과와 비교 결과, 제안된 강도모델은 현행 설계기준 보다 실험체의 강도를 더 정확하게 추정하는 것으로 밝혀졌다.

Effect of progressive shear punch of a foundation on a reinforced concrete building behavior

  • Naghipour, Morteza;Niak, Kia Moghaddas;Shariati, Mahdi;Toghroli, Ali
    • Steel and Composite Structures
    • /
    • 제35권2호
    • /
    • pp.279-294
    • /
    • 2020
  • Foundation of a building is damaged under service loads during construction. First visit shows that the foundation has been punched at the 6 column's foot region led to building rotation. Foundation shear punching occurring has made some stresses and deflections in construction. In this study, progressing of damage caused by foundation shear punching and inverse loading in order to resolve the building rotation has been evaluated in the foundation and frame of building by finite element modeling in ABAQUS software. The stress values of bars in punched regions of foundation has been deeply exceeded from steel yielding strength and experienced large displacement based on software's results. On the other hand, the values of created stresses in the frame are not too big to make serious damage. In the beams and columns of ground floor, some partial cracks has been occurred and in other floors, the values of stresses are in the elastic zone of materials. Finally, by inverse loading to the frame, the horizontal displacement of floors has been resolved and the values of stresses in frame has been significantly reduced.

CFT기둥-RC 무량판 접합부의 펀칭전단강도 및 거동 (Punching Shear Strength and Behavior of CFT Column to RC Flat Plate connections)

  • 이철호;김진원
    • 한국강구조학회 논문집
    • /
    • 제18권4호
    • /
    • pp.491-502
    • /
    • 2006
  • 본 논문은 중력하중의 지배를 받는 CFT기둥-RC 무량판 접합부의 실물대 실험결과를 요약한 것이다. CFT구조는 여러 가지 구조및 시공상의 장점으로 인하여 국내 건설 현장에서 상대적으로 짧은 시간에 폭넓게 수용되고 있다. 주차장 용도로 주로 사용되는 지하층은 철근콘크리트 무량판으로 시공하여 경제성을 도모하는 것이 국내에서 일반적으로 요구되는 시공관행이다. 그러나 CFT기둥-R C 무량판 접합부의 효율적인 디테일은 아직 국내 외적으로 제시된 바가 없어서 이 분야의 연구가 매우 필요한 실정이다. 현장 시공시 경제성을 극대화할 수 있는 몇 가지 전략을 기초로 해서, 여러가지 접합 상세를 제안하였고 실험을 통하여 검증하엿다. 실험결과 본 연구에서 제시된 CFT기둥-RC 무량판 접합 상세의 펀칭강도 및 강성이 RC 무량판 접합부와 동등하거나 이를 상회하는 것을 확인할 수 있었다. CFT기둥-RC 무량판 접합부의 초기 탄성거동에서 펀칭파괴이후 휨철근의 국부 현수작용에 이르기까지의 모델링 방안을 제시하고 본 연구의 실험결과를 기초로 5개의 모델링 변수를 캘리브레이션하였다. 또한 무량판구조의 연쇄붕괴방지 설계에 본 연구의 결과를 응용하는 방안을 사례를 통하여 예시하였다.

거푸집 패널이 부착된 2방향 중공슬래브의 뚫림 전단 안전성 평가 (Evaluation of Punching Shear Safety of a Two-Way Void Plywood Slab System with Form)

  • 허무원;우형식;박정민;강현욱;박태원
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권5호
    • /
    • pp.182-189
    • /
    • 2021
  • VPS는 중공재의 형상을 최적화 하고 중공재의 부상 및 작업하에 의한 이탈을 방지하는 기능을 가진 기존 중공슬래브공법이다. 본 연구에서는 기존연구에서 제안한 거푸집 패널이 부착된 중공슬래브(VPS)를 활용하여 플랫 플레이트의 뚫림전단 안전성을 검토하였다. 실험 결과, 가력점으로 부터 기둥 폭의 2.0배를 넘어 중공재를 배치한 VSPS 실험체는 기준 실험체에 대비 내력이 9.4%감소하였다. KBC2016에서 제시한 설계 값의 약 1.57배 이상의 강도 값을 나타내었다. 중공재를 배치한 VSPS 실험체가 전단파괴가 발생하기 전까지 기준 실험체 대비 강성의 변화는 없는 것으로 나타났다. 이는 휨 철근을 충분하게 배근하여 본 실험이 전단에 의해 파괴되고 있음을 알 수 있다.

정(井)자형 H형강으로 구속된 철근콘크리트 기둥접합부의 뚫림전단에 관한 실험적 연구 (An Experimental Study on Punching Shear at the Connection of RC Column Constrained by H-Beam with 井 Shape)

  • 김량운;이수권;이정윤;정창용;김상식
    • 콘크리트학회논문집
    • /
    • 제21권3호
    • /
    • pp.319-326
    • /
    • 2009
  • 정(井)자형 H형강을 강축의 수직 방향에 대해 띠판으로 연결한 조립보를 수평버팀대로 사용하면 구조적으로 약축 방향의 세장비를 줄여 구조 효율을 높일 수 있으며 또한 이를 구조물 지하 골조의 일부로 사용하여 시공성을 개선시킬 수 있다. 이 시스템의 H형강이 서로 만나는 교차 부분에는 콘크리트가 채워지고 그 사각형 가운데는 철근콘크리트 기둥이 위치하게 된다. 보-기둥 접합부의 뚫림 전단거동은, 사변을 구속하고 있는 H형강에 의해 전단균열에 의한 방사변형이 구속되어지며, H형강이 접합부를 충분히 구속할 수 있는 경우 하중 전달이 효과적으로 이루어지고, 일반적인 경우의 뚫림 전단강도보다는 더 큰 내력을 가지게 된다. 이 현상을 확인하기 위하여 구속 여부와 기둥면에서 구속 H형강까지의 거리를 변수로 하여 실험하였다. 실험 결과는 콘크리트구조설계기준을 준용하여 얻은 식과 비교하였고, 제안된 식을 통하여 계산된 결과는 실험을 통해 얻은 뚫림 전단강도와 비슷한 결과를 나타냈다.