• Title/Summary/Keyword: Pumping speed

Search Result 162, Processing Time 0.02 seconds

FPSO Cargo Pumping 시스템 가상운전 시스템 개발

  • Nam, Ki-Il;Han, Ki-Hun;Chang, Kwang-Pil;Oh, Tae-Young;Chang, Dae-Jun;Song, Seok-Ryong
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.251-252
    • /
    • 2006
  • This study developed the virtual operation system for the hydraulic pump system for marine usage. The scope of this study is to develop a process dynamic simulation model for the hydraulic pump system for marine usage, to investigate the process dynamic characteristics using the models, to accomplish the logic diagram for the PLC control and to achieve a human-machine interface (HMI) for the convenience of operators to monitor and control the process. The virtual operation system provides a virtual operation environment for the pumping system, enabling the operators to simulate the change of process variables. The system will assist in developing advanced control logics and then optimal design of the system.

  • PDF

Effects of Variable Valve Timing Operation Modes on Engine Performance (가변 밸브개폐시기 기구 운전의 엔진 성능에의 영향)

  • 구준모;배충식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.6
    • /
    • pp.24-29
    • /
    • 2001
  • Adaptive valve timing control is one of the promising techniques to accomplish the optimized mixture formation and combustion depending on the load and speed, which is needed to meet the future challenges in reducing fuel consumption and exhaust emissions. The behavior and the effect of adaptive valve timing control system has been investigated by computer simulation, which simulates the gas dynamics in engines. Improved fuel economy can be achieved by reduction of pumping loss under low and mid load conditions. EIVC(Early Intake Valve Closing) strategy turns out to be superior to LIVC(Late Intake Valve Closing) strategy in reducing fuel consumption. Deterioration of combustion quality can be overcome by introducing LIVO(Late Intake Valve Opening) strategy, which increases turbulent intensity in cylinders. Furthermore, LIVO can reduce HC emission by decreasing the required amount of fuel to be injected during cold start.

  • PDF

Effects of VGT on Part Load Performance of Diesel Engine (VGT가 디젤엔진의 부분부하 성능에 미치는 영향)

  • Choi, Kwon Sick;Song, Seung Jin
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.680-686
    • /
    • 2004
  • Recently, the application of variable geometry turbocharger (VGT) to the high speed direct injection (HSDI) diesel engine has gained more and more interest in automotive industry. A steady state experimental investigation has been undertaken on a 1.5L HSDI diesel engine to verify the benefits of VGT comparing to the standard engine having a waste gate turbocharger (WGT). Specifically, part load performances (e.g., fuel economy and emission) have been investigated under various vane angles of the VGT. The results show that the real exhaust gas recirculation (EGR) rate as well as the pumping loss is very important to improve break specific fuel consumption (BSFC). It was previously known that the pumping loss only is a main parameter. In addition, the trade-off relationship between BSFC and NOx according to boost pressure, and the decreasing tendency of NOx with increasing real EGR rate have been verified. 1-D numerical analysis also has been performed, and the numerical results are in good agreement with experimental results.

  • PDF

분자 드래그 회전자 형상에 따른 복합분자펌프의 배기성능에 관한 실험적 연구

  • Hwang Yeong-Gyu;Gwon Myeong-Geun
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2006.05a
    • /
    • pp.202-205
    • /
    • 2006
  • Recently, high vacuum pumps are widely used in the semi-conduction and liquid-crystal display ( LCD ) process. The composite-type high vacuum pumps are widely used in the various processes. In this study, the pumping performance of composite-type molecular pumps has been investigated experimentally. The experimented pumps are a compound molecular pump ( CMP ) and hybrid molecular pump ( HMP ). The CMP consists with helical-type drag pump, at lower part, and with turbomolecular pump ( TMP ), at upper part. The HMP consists with disk-type drag pump, at lower part, and with TMP, at upper part. The experiments are performed in the outlet pressure of $0.2\;{\sim}\;533\;Pa$. We have measured the ultimate pressure, compression ratio, and pumping speed

  • PDF

Analysis of Two-Dimensional Flow Fields in the Multi-Stage Turbomolecular Pump Using the DSMC Method

  • Heo, Joong-Sik;Hwang, Young-Kyu
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.2
    • /
    • pp.8-18
    • /
    • 2001
  • The direct simulation Monte Carlo Method is applied to investigate the two-dimensional flow fields of a turbomolecular pump(TMP) in both molecular and transition flow regions. The pumping characteristics of the TMP are investigated for a wide range of the Knudsen number. The maximum of compression ratio and of pumping speed strongly depend on the Knudsen number in transition region, while they weakly depend on the Knudsen number in free molecular flow region. The present numerical results show good agreement with the previously known experimental data. Finally. the results of the single blade row in both molecular and transition regions are used to predict the overall performance of a TMP, which has three kinds of blade with 24-rows.

  • PDF

Dynamic Response of the System for Vacuum Pump Performance Evaluation (진공 펌프 성능 평가 계통의 동적 응답)

  • Sim, Woo-Gun;Lim, Jong-Yeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.11
    • /
    • pp.1359-1367
    • /
    • 2004
  • The demand of vacuum pump has been increased in the process of semi-conduct manufacturing, as a core component. The response of the system for vacuum pump performance test can be utilized to assess the system and to obtain the reliability of the apparatus for the test. The system consists of gas supply tank, pressure chamber, measurement chamber and transmission line. Transient analysis for compressible fluid has been conducted to evaluate the dynamic characteristic of the volume terminated transmission line. Numerical approach based on the method of characteristics is used for the analysis. The response is evaluated with the important parameters for the system: i.e., length and diameter of the line, volume of the terminal tank. Using the numerical results, pumping speeds are calculated and then compared to the experimental results.

Frictional and Electrical Characteristics of Herringbone Grooved Bearing for Scanner motor

  • Jeong, Sung-Hoon;Lee, Young-Ze
    • KSTLE International Journal
    • /
    • v.2 no.2
    • /
    • pp.146-149
    • /
    • 2001
  • Recently, laser printers have been developed to have high-speed laser scanner with hydrodynamic bearings. Among the bearings, herringbone grooved bearing (HGB) produces hydrodynamic pressure by high-speed rotating and so make the surfaces between the shaft and sleeve separated. Accordingly, the bearings with non-contact rotation are suitable to high-speed rotating and have long bearing life and reliability. HGB is a kind of journal bearing and uses oil for a lubricant. HGB has excellent stiffness and load carrying capacity. Also, HGB is leakage-free due to groove pumping action. Consequently, HGB is valuable to be applied to high-performance devices such as hard disk drive, copier, and so on.

  • PDF

Modeling and Simulation with a Variable Speed Drive System of a Electric Motor Using MATLAB/SIMULINK (MATLAB/SIMULINK를 이용한 전동기 가변속 구동시스템 모델링 및 시뮬레이션)

  • 정삼용;최연옥;한엄용;오금곤;정수복;조금배
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.141-147
    • /
    • 1997
  • The variable speed drive system of a electric motor is popular in industry due to its economical aspect and simplicity of implementation, comparing with a steam turbine or the other engine driven. For a large pumping load like a feedwater pump rated about or more than 20,000㎾, a synchronous motor could be primarily considered. In this paper, we studied the modelling of a variable speed drive system consisted with a load commutated inverter(LCI) and a brushless sailent pole rotor synchronous motor(SM) using MATLAB/SIMULINK. Simulation was performed with a small SM motor parameters.

  • PDF

Prediction of Vehicle Fuel Consumption on a Component Basis (가솔린 차량의 각 요소별 연료소모량 예측)

  • 송해박;유정철;이종화;박경석
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.2
    • /
    • pp.203-210
    • /
    • 2003
  • A simulation study was carried to analyze the vehicle fuel consumption on component basis. Experiments was also carried out to identify the simulation results, under FTP-75 Hot Phase driving conditions. and arbitrary driving conditions. A good quantitative agreement was obtained. Based on the simulation, fuel energy was used in pumping loss(3.7%), electric power generation(0.7%), engine friction(12.7%), engine inertia(0.7%), torque converter loss(4.6%), drivetrain friction(0.6%), road-load(9.2%), and vehicle inertia(13.4%) under FTP-75 Hot Phase driving conditions. Using simulation program, the effects of capacity factor and idle speed on fuel consumption were estimated. A increment of capacity factor of torque converter resulted in fuel consumption improvement under FTP-75 Hot Phase driving conditions. Effect of a decrement of idle speed on fuel consumption was negligible under the identical driving conditions.

Development of Improvement Technology for Achieving Higher Throughput Limit Utilized in the Evaluation of Next Generation Dry Pumps (첨단공정용 드라이펌프 유량 측정 한계 향상기술 개발)

  • Shin, J.H.;Ko, M.K.;Cheung, W.S.;Yun, J.Y.;Lim, J.Y.;Kang, S.W.
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.6
    • /
    • pp.411-417
    • /
    • 2009
  • The constant volume flow meter system (the chamber volume in the 22 L class) was developed to estimate the pumping speed of the dry pump used for the industry of the next generation semiconductor and display. In order to insure the validity of the system, The base pressure and the leak rate in the enclosed system were checked, which were the $6{\times}10^{-8}\;mbar$ and $1.5{\times}10^{-6}\;mbar-L/s$, respectively. Furthermore, it is also confirmed that the value of throughput limit in this system was as much as 1 order of magnitude lower than that in a previously developed system in the 875 L class. By using this developed system, the pumping speed of the new small dry pump was measured. It is believed that the new developed system can be alternating the expensive constant pressure flow meter system in the range of $1{\times}10^{-2}\;mbar-L/s{\sim}1{\times}10^{-3}\;mbar-L/s$.