• Title/Summary/Keyword: Pumping power

Search Result 361, Processing Time 0.024 seconds

Drag Reduction Phenomena of Surfactant Turbulent Pipe Flows (계면활성제에 의한 난류 관내 유동의 마찰감소 현상)

  • Yoon, Hyung-Kee;Shin, Kwang-Ho;Chang, Ki-Chang;Ra, Ho-Sang;Yoo, Seong-Yeon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.12
    • /
    • pp.1025-1032
    • /
    • 2006
  • This is to characterize the fluid mechanics of surfactant water solutions, which exhibit drag reduction in the turbulent flow as compared to pure water. The emphasis is placed on those fluid characteristic aspects of drag reducing solutions which are relevant for application in closed circulation loops for the purpose of pumping power savings, like hydronic cooling and heating systems in buildings. The experiments are carried out with the solutions of the surfactant Beraid DR-IW 616 in concentration of $100{\sim}3,000ppm$. The following key parameters are focused in this study: surfactant concentration, solution temperature and pipe diameter.

Numerical Simulation of Flow and Heat Transfer in Cooling Channel with a Staggered V-shaped Rib (엇갈린 V-형 리브가 부착된 냉각유로에서의 열유동 수치해석)

  • Myong, Hyon-Kook;Kim, Kwang-Yong
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2448-2453
    • /
    • 2008
  • The present study numerically investigates the flow and heat transfer characteristics of rib-induced secondary flow in a cooling channel with staggered V-shaped ribs, extruded on both walls. The rib-height-to-hydraulic diameter ration (h/$D_h$) is 0.17; the rib pitch-to-height ratio (p/h) equals 2.8; the Reynolds number is 50,000. Shear stress transport (SST) turbulence model is used as a turbulence closure. The present results are compared with those for a continuous V-shaped rib. Computational results show that, for average heat transfer rate the staggered V-shaped rib gives about 2.5 times higher values than the continuous V-shaped rib, while, for the streamwise pressure drop the former gives about 5 times higher values than the latter. Consequently, for the thermal performances, based on the equal pumping power condition, the staggered one gives about 2 times higher values than the continuous one. Also, for the staggered V-shaped rib, complex secondary flow patterns are generated in the duct due to the snaking flow in the streamwise direction, and more uniform heat transfer distributions are obtained.

  • PDF

A Study on the Heating Characteristics of Radiant Floor Panel Using Heat Pipes with the Double Wick (이중 윅 타입 히트파이프를 이용한 바닥복사패널의 난방특성 연구)

  • Kim, Yong-Ki;Lee, Tae-Won
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.2
    • /
    • pp.183-189
    • /
    • 2012
  • Most of the domestic residential buildings have used the traditional radiant heating system, circulating hot water through the cross-linked polyethylene(PE-X) pipe buried in the floor panel of the heating space. New type of the heating panel was recently developed using heat pipes with double wicks. Some experiments were carried out in this study to verify the thermal characteristics of this heating system at the unit heating space which surrounded by outer space whose temperature of air be maintained scheduled value with time. Through the various experiments with several parameters, such as flow rate, inlet and outlet temperatures of hot water and the heating duration and so on, we found that the floor heating system with heat pipes was able to reduce the pumping power for hot water circulation by 4~31% compared with the conventional panel heating system using PE-X pipe. These results could be used for optimal design and efficient operation of the heating system as well as improvement of thermal comfort.

Performance evaluation of bubble pump used on solar water heating system

  • Xuesong, Li;Park, Gi-Tae;Kim, Pil-Hwan;Chung, Han-Shik;Jeong, Hyo-Min
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.416-422
    • /
    • 2007
  • The application analysis of bubble pump on the domestic solar water heater system is presented. The system investigated in this study is a passive device, self pumping and self regulating. It was test to use the bubble pump on solar water heater system. The test experiment has been taken on the existed vacuum tube about the efficiency, working fluid temperature and pressure and circulated power. In order to check the working temperature and working pressure effectively, the bubble pump was test separated from the solar water heater. The equipment consists of the bubble pump, heater and heat exchanger. The main structure of bubble pump was design depend on the character of two phase flow. The complete system was instrumented to measure pressures, temperatures and their relationship with the solar radiation intensity. The theory analysis of design bubble pump has been given and the experiment result analysis has been included in the paper.

  • PDF

Plant Community Structure of the Choksangsansong Area in T$\v{o}$kyusan National Park (덕유산 국립공원 적상산성 일원의 식물군집구조)

  • 오구균
    • Korean Journal of Environment and Ecology
    • /
    • v.7 no.2
    • /
    • pp.172-180
    • /
    • 1994
  • The forest of Choksangsansong area was studied to investigate vegetational structure with twenty-five plots(20m$\times$25m). Relative importance values, DBH class distribution, species, diversity indices, DCA ordination and TWINSPAN classification were used for vegetational structure analysis. Quercus mongolica, Carpinus cordata, Quercus serrata and Cornus controversa were appeared to be dominant species in each plot and dominant species in the Choksangsansong area was Quercus mongolica. The forest of Choksangsansong area was classified into four groups and showed seral stage from Quercus mongolica to Carpinus cordata. Vegetational succession in the Choksangsansong area shall be accelerated to moist and shade tolerant species due to cool and humid climatic condition by upper dam construction of the Mujuyangspalchonso (pumping up power station).

  • PDF

Genesis of Researches on Surges in Pumping Systems in Japan

  • Yamaguchi, Nobuyuki;Tsujimoto, Yoshinobu
    • International Journal of Fluid Machinery and Systems
    • /
    • v.9 no.1
    • /
    • pp.17-27
    • /
    • 2016
  • Researches on the mechanism of surging and the surge behaviors in the systems of pumps, or fans or compressors, and the effects of flow-paths had been initiated and had made a great progress in Japan in the decades from the nineteen-forties to the nineteen-sixties. In 1947, the essential cause of the surges, i.e., self-excited oscillation nature of the flow-system, was discovered analytically by Professor Sumiji Fujii of Tokyo University, and most of the characteristic behaviors of the phenomena had been explained clearly. Successive studies by many other Japanese researchers continued to prove experimentally the mechanism, to extend the analytical studies, and to attempt preventing surge occurrence, etc. in the following two decades. The historical information on the early surge studies could be helpful to some concerned people. At the same time, the basic and plain ways of discussions and reasoning about the phenomena in the pioneering researches could give us much to be learned even in the present time of high-power computing systems. Regrettably, many of the original research works have been published only in Japanese. The present review introduces very briefly the situations in memories of the pioneering researchers and engineers.

Performance Optimization of High Specific Speed Pump-Turbines by Means of Numerical Flow Simulation (CFD) and Model Testing

  • Kerschberger, Peter;Gehrer, Arno
    • International Journal of Fluid Machinery and Systems
    • /
    • v.3 no.4
    • /
    • pp.352-359
    • /
    • 2010
  • In recent years, the market has shown increasing interest in pump-turbines. The prompt availability of pumped storage plants and the benefits to the power system achieved by peak lopping, providing reserve capacity, and rapid response in frequency control are providing a growing advantage. In this context, there is a need to develop pumpturbines that can reliably withstand dynamic operation modes, fast changes of discharge rate by adjusting the variable diffuser vanes, as well as fast changes from pumping to turbine operation. In the first part of the present study, various flow patterns linked to operation of a pump-turbine system are discussed. In this context, pump and turbine modes are presented separately and different load cases are shown in each operating mode. In order to create modern, competitive pump-turbine designs, this study further explains what design challenges should be considered in defining the geometry of a pump-turbine impeller. The second part of the paper describes an innovative, staggered approach to impeller development, applied to a low head pump-turbine project. The first level of the process consists of optimization strategies based on evolutionary algorithms together with 3D in-viscid flow analysis. In the next stage, the hydraulic behavior of both pump mode and turbine mode is evaluated by solving the full 3D Navier-Stokes equations in combination with a robust turbulence model. Finally, the progress in hydraulic design is demonstrated by model test results that show a significant improvement in hydraulic performance compared to an existing reference design.

Pipeline Transport of Dredged Soils (준설토의 관로유송)

  • 유동훈;김성오;선우중호
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.8 no.1
    • /
    • pp.114-122
    • /
    • 1996
  • Pipeline transport of dredged soils has been widely used for reclamation. In this case the fluid mixed with soils, so called slurries, has very much different characteristics from pure fluids. As the slurry fluid has a peculiar mode in the viscosity, a proper equation of friction factor has to be used which is pertinent to the characteristics of slurry flow for the estimation of pipeline transport of dredged soils. The slurry fluid has the characteristics of Newtonian fluid or non-Newtonian fluid largely depending on the size of particles. In the present study, new forms of pipe friction factor equations have been suggested for both conditions, and using these forms explicit equations have been developed for the computation of relevant pipe diameter and discharge as well as pumping power.

  • PDF

Heat Transfer and Frictions in the Convergent/divergent Channel with Λ/V-shaped Ribs on Two Walls

  • Kim, Beom-soo;Lee, Myung-sung;Ahn, Soo-whan
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.18 no.3
    • /
    • pp.395-402
    • /
    • 2017
  • The local heat transfer and total pressure drops of developed turbulent flows in the ribbed rectangular convergent/divergent channels with ${\Lambda}/V-shaped$ ribs have been investigated experimentally. The channels have the exit hydraulic diameter ($D_{ho}$) to inlet hydraulic diameter ($D_{hi}$) ratios of 0.67 for convergence and 1.49 for divergence, respectively. The ${\Lambda}/V-shaped$ ribs with three different flow attack angles of $30^{\circ}$, $45^{\circ}$, and $60^{\circ}$ are manufactured with a fixed rib height (e) of 10 mm and the ratio of rib spacing (S) to height (e) of 10 on the walls. Thermal performances of the ribbed rectangular convergent/divergent channels are compared with the smooth straight tube under identical pumping power. The results show that the flow attack angle of $45^{\circ}$ with ${\Lambda}-shaped$ rib has the greatest thermal performance at all the Reynolds numbers studied in the convergent channel; whereas, the flow attack angle of $60^{\circ}$ with V-shaped rib has the greatest thermal performance over Reynolds number of 30,000 in the divergent channel.

Photoluminescence Characteristics of InAs Quantum Dots Grown on AlAs Epitaxial Layer (AlAs 에피층 위에 성장된 InAs 양자점의 Photoluminescence 특성연구)

  • Kim, Ki-Hong;Sim, Jun-Hyoung;Bae, In-Ho
    • Korean Journal of Materials Research
    • /
    • v.19 no.7
    • /
    • pp.356-361
    • /
    • 2009
  • The optical characterization of self-assembled InAs/AlAs Quantum Dots(QD) grown by MBE(Molecular Beam Epitaxy) was investigated by using Photoluminescence(PL) spectroscopy. The influence of thin AlAs barrier on QDs were carried out by utilizing a pumping beam that has lower energy than that of the AlAs barrier. This provides the evidence for the tunneling of carriers from the GaAs layer, which results in a strong QD intensity compared to the GaAs at the 16 K PL spectrum. The presence of two QDs signals were found to be associated with the ground-states transitions from QDs with a bimodal size distribution made by the excitation power-dependent PL. From the temperature-dependent PL, the rapid red shift of the peak emission that was related to the QD2 from the increasing temperature was attributed to the coherence between the QDs of bimodal size distribution. A red shift of the PL peak of QDs emission and the reduction of the FWHM(Full Width at Half Maximum) were observed when the annealing temperatures ranged from 500 $^{\circ}C$ to 750 $^{\circ}C$, which indicates that the interdiffusion between the dots and the capping layer was caused by an improvement in the uniformity size of the QDs.