• 제목/요약/키워드: Pump-pulsation

검색결과 81건 처리시간 0.018초

다이아프램 정량펌프의 맥동감쇄 장치 (Pulsation Dampener for Diaphragm Metering Pump)

  • 윤승원
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.1143-1147
    • /
    • 2004
  • A mechanical type pulsation dampener for the diaphragm metering pump has been developed. The pulsation pressure is an inevitable phenomenon for the positive displacement pump such as cam operated or solenoid operated metering pump. The pulsation pressure of the metering pump could be the noise source and would be harmful for the piping system which delivers hydraulic fluid. Developed pulsation dampener consists of three coil springs which have different spring constant and height each other. Depending on pressure magnitude of the piping system, total hydraulic pressure on damping diaphragm which compresses coil springs will be varied. Force equilibrium of the pulsation dampener will be set by manual by adjusting the compressed coil spring height. During the discharge stroke, pulsation dampener stores potential energy that is released as the pumping diaphragm back to an initial position during the suction stroke.

  • PDF

Design of Port Plate in Gerotor Pump for Reduction of Pressure Pulsation

  • Kim Sang-Yeol;Nam Yun-Joo;Park Myeong-Kwan
    • Journal of Mechanical Science and Technology
    • /
    • 제20권10호
    • /
    • pp.1626-1637
    • /
    • 2006
  • The pressure pulsation due to the gear geometry of the gerotor (generalized rotor) pump mainly occurs in an instant that the chamber of the gerotor enters the delivery port and leaves the suction one. Such a pressure pulsation may result in undesirable vibration and noise of pump components as well as cavitation in hydraulic system. Therefore, it is very important to examine the pressure characteristic of the gerotor pump at its design and analysis stages. In this paper, in order to reduce the pressure pulsation in the gerotor pump, the port plate with the relief grooves is designed by referring to as notch of vane pump and relief groove of piston pump. A series of the theoretical analyses on the pressure pulsation is performed in consideration of various design parameters of the port plate, including the installation positions of the port inlet/outlet and the groove width, and the operating conditions such as rotational velocity and delivery pressure.

Research on non-uniform pressure pulsation of the diffuser in a nuclear reactor coolant pump

  • Zhou, Qiang;Li, Hongkun;Pei, Lin;Zhong, Zuowen
    • Nuclear Engineering and Technology
    • /
    • 제53권3호
    • /
    • pp.1020-1028
    • /
    • 2021
  • The nuclear reactor coolant pump transferring heat energy inherently brings with it the unsteady flow and inevitably threatens to the safe operation of the pump unit, especially with the pressure pulsation induced by the rotor-stator interaction. In this paper, the characteristics of pressure pulsation of the diffuser in a nuclear reactor coolant pump were investigated by the numerical simulation with experimental validation. Pressure pulsation signals measured synchronously from sensors mounted on the radial diffuser of a model pump were analyzed via Welch's method. Frequency components induced by the rotor-stator interaction can be revealed by the diameter mode analysis method. The pressure pulsation of the diffuser is dominated by the blade passing frequency and its harmonics, which are free from the effect of flow rate and rotational speed while the corresponding amplitudes are easily affected by different operational conditions and measuring positions. The non-uniformity is much more affected by the rotational speed than the flow rate. This research is helpful for further work to reduce the pressure pulsation for the reactor coolant pump.

다중 토출 레이디얼 유압 피스톤 펌프의 압력 맥동 특성 (Pressure Pulsation Characteristics of a Multiple-Delivery Radial Piston Hydrulic Pump)

  • 최세령;임종철;이일영
    • 드라이브 ㆍ 컨트롤
    • /
    • 제11권2호
    • /
    • pp.1-8
    • /
    • 2014
  • In this study, the authors carried out experiments and numerical simulations in order to clarify the pressure pulsation characteristics in multiple-delivery rotating-cam and stationary-cylinder type radial piston pumps. Also, a tee filter was applied to the pump in order to mitigate the pressure pulsation. Through the experiments and simulations, it was known that pressure pulsation with a magnitude higher than 40% of the mean load pressure could occur in the pump used in the experiments. Moreover, it was confirmed that a tee filter designed in this study could effectively mitigate the pressure pulsation.

가변 사판식 피스톤펌프의 맥동 변수 분석 및 최적 밸브플레이트 노치 설계를 위한 압력 및 유량맥동에 관한 연구 (Study of Pressure and Flux Pulsation to Design Optimum Valve-Plate Notch and Pulsation-Variables Analysis of Swash-Plate-Type Piston Pump)

  • 배준형;정원지;장준호;윤영환;전주열
    • 한국생산제조학회지
    • /
    • 제24권2호
    • /
    • pp.244-250
    • /
    • 2015
  • We propose a simulation technique to estimate the reduction effect of the pressure/flow pulsation by analysis of the pulsation variables and notch shape of the valve plate of a swash-plate-type variable piston pump. First, using SimulationX$^{(R)}$, we perform a theoretical kinematic analysis according to the variable swash-plate angle and rotational velocity in order to design a single-piston pump. In designing the notch shape of the valve plate of the swash-plate-type variable piston pump as one of the pulsation variables, we investigate the effect of the pulsation by comparing two notch types (circular type and V type). Then, we extend our analysis to a nine-piston pump model. This paper not only confirms the effect of the pressure/flow pulsation according to pulsation variables but can also be applied to the development of a SimulationX$^{(R)}$-based simulation technique for notch-shape optimization for a swash-plate-type variable piston pump.

사판식 피스톤 펌프-관로계에서의 맥동류 해석 (Analysis of Pulsating Flow in a Swash Plate Type Piston Pump and Transmission Line)

  • 최영학;이일영
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.45-49
    • /
    • 2000
  • Vibration and noise problem in a hydraulic system became one of very important factors in evaluating the performance of a hydraulic system. It is known that vibration and noise in a hydraulic system is directly related to flow pulsation in the hydraulic pump in the system. This study investigated a modeling and simulation technique for pulsating flow in a swash plate type axial piston pump. The key design factors of the pump related to flow pulsation phenomenon of the pump are the physical parameters for notches on the valve plate of the pump. By the numerical analysis, effects of the physical parameters of the notch on the flow pulsation was elucidated.

  • PDF

유압 굴삭기용 펌프의 개구면적 규명에 관한 연구 (A Study on Identification of Open Area of Pump for Hydraulic Excavator)

  • 임태형;오병수;이홍선;양순용
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.101-102
    • /
    • 2006
  • The purpose of this paper is pulsation-analysis of the swash plate type axial piston pump for excavator and the method of side branch hose application, which is used normally in construction equipments. In this paper, draw the mathematical modeling for pressure pulsation mechanism of the swash plate type axial piston pump for excavator, expression the flow pulsation in the pipelines by transfer matrix method, programmed simulation for pulsation by AMEsim software, and the reliability of that was verified by the comparison with the experimental results.

  • PDF

전산유체해석을 이용한 축류형 혈액펌프의 용혈평가 (Evalution of Hemolysis in Axial Flow Blood Pump with Computational Fluid Dynamics Analysis)

  • 임상필;김동욱
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2003년도 춘계학술발표논문집
    • /
    • pp.256-259
    • /
    • 2003
  • Artificial heart is divided pulsation style and nonpulsation style greatly according to flowing of blood. nonpulsation pump is advantage of miniaturization avaliable because it is simple and non-volumic-pump than pulsation pump. Non pulsation pump is derided axial flow style and centrifugal style accordig to rotating style. An axial flow blood pump can be made smaller than a centrifugal blood pump because of its higher specific speed. A hemolysis is an important factor for the development of an axial flow blood pump. It is difficult to identify the areas where hemolysis nun. Evaluation of hemolysis both in in vitro and in vivo require a long time and are costly. Computational fluid dynamics(CFD) analysis enables the engineer to predict hemolysis on a computer. The aims of this study is Computational fluid dynamics in the whole axial flow pump and to verify the accuracy of prediction results of CFD analysis compare with in vitro experimental results.

  • PDF

엘리베이터용 기어펌프 개발 (Development of the Hydraulic Gear Pump for an Elevator)

  • 정석훈
    • 한국기계기술학회지
    • /
    • 제13권4호
    • /
    • pp.117-124
    • /
    • 2011
  • A gear pump is a type of pump that displaces a volume of fluid by physical or mechanical action, or positive displacement pump. Power is applied to one of the gears and transmitted to a second driven gear via meshing teeth. This paper describes the hydraulic gear pump for an elevator. In gear pump, since geometrically special forms of gear tooth, 'Pulsations' is always caused in the delivery pressure and quantity. In other words, it is found that the number of delivery pressure pulsation per each revolution is always equal to that of the gear-teeth of the gear, which is coincident with the pulsation of the ideal delivery quantity. Some experimental results are given to verify the effectiveness of the developed pump.

중대형 굴삭기 유압시스템의 압력 맥동 저감 연구 (A Study on the Pulsation Pressure Reduction for the Hydraulic System of Medium-Large Excavator)

  • 김영현;주원호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 추계학술대회 논문집
    • /
    • pp.421-426
    • /
    • 2010
  • With hydraulic noise test facility, a variety of tests were performed to investigate the pulsation pressure generation mechanism and its transmission characteristics and to derive the noise control methodology. Many experiments were carried out by changing average pressure, flow rate, pump speed, hose length and MCV spool condition. From the test results, the correlations between pulsation pressure and other design parameters, such as static pressure, flow rate and MCV spool opening area and length of hose, were found out. And also each contribution factors were evaluated from the regression analysis. By changing hose length, the pulsation pressure resonance phenomenon was investigated. In order to find out the pulsation pressure reduction measures pulsation pressure analysis, such as pulsation pressure of hydraulic pump itself and pulsation pressure of hydraulic system, by using AMESim were studied. In addition hydraulic silencer was developed based on the Helmholtz resonator. And its performance was evaluated by installing the silencer at the excavator.

  • PDF