• 제목/요약/키워드: Pump Supply Pressure

검색결과 151건 처리시간 0.037초

오리피스와 방향제어밸브를 이용한 미세유량 분사제어시스템 (Infinitesimal Fluid Injection Control System by using an Orifice and a Directional Control Valve)

  • 정은석;오인호;이일영
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.67-68
    • /
    • 2006
  • This study suggests a precision flow control system that enables fluid injection of a few grams at a time in a few ms time duration. The fluid injection system suggested here consists of a high pressure fluid pump, a 3 way 3 position directional control valve, an injector and an orifice. The orifice is located between the directional control valve and the injector. By supplying current signal to the directional control valve, the prescribed small amount of fluid can be supplied to a plant through the injector. The control robustness of the suggested system against the disturbances like the pressure change in a plant and the viscosity variation of the injected fluid is secured easily by using an orifice with very small inside diameter and setting the supply pressure with comparatively high value. The control performances of the suggested system are verified by numerical simulations and experiments. The outcomes of this research could be applied to the common rail injection control of lubrication oil for large size marine diesel engines, and other industrial plants.

  • PDF

PAG 오일이 $CO_2$ 증발열전달에 미치는 영향에 관한 실험적 연구 (Experimental Study on Effects of PAG Oil for $CO_2$ Evaporation Heat Transfer)

  • 이상재;김대훈;최준영;이재헌;권영철
    • 설비공학논문집
    • /
    • 제20권5호
    • /
    • pp.357-363
    • /
    • 2008
  • In order to investigate $CO_2$ heat transfer coefficient and pressure drop by PAG oil concentration during $CO_2$ evaporation, the experiment on evaporation heat transfer characteristics in a horizontal micro-fin tube was performed. The experimental apparatus consisted of a test section, a DC power supply, a heater, a chiller, a mass flow meter, a pump and a measurement system. Experiment was conducted for various mass fluxes($400{\sim}1200\;kg/m^2s$), heat fluxes($10{\sim}30\;kW/m^2$) and saturation temperatures ($-5{\sim}5^{\circ}C$), and PAG oil concentration($0{\sim}5\;wt%$). The variation of the heat transfer coefficient was different in accordance with the oil concentration. With the increase of the oil concentration, the evaporation heat transfer coefficient decreased and the delay of dryout by oil addition was found. Pressure drop increased with the increase of the oil concentration and heat flux, and the decrease of saturation temperature.

수위센서를 이용한 액적 토출 시스템 설계에 관한 연구 (A Study on the Design of a Liquid Droplet Discharge System Using a Water Level Sensor)

  • 이윤민;신진섭
    • 한국인터넷방송통신학회논문지
    • /
    • 제24권4호
    • /
    • pp.129-134
    • /
    • 2024
  • 본 논문에서는 적외선 센서, 레이저 센서, 초음파 센서, 정전용량 센서로 실험을 통해 수위의 변화를 선형적으로 감지할 수 있는 수위센서를 이용한 액적 토출 시스템을 연구하였다. 전원 공급으로 SMPS, 레귤레이터 5V, LDO 3.3V를 설계하였으며 수위 센서 입력부 ADC 회로와 마이크로프로세서를 이용하였다. 또한 솔레노이트 밸브 제어, 양압/음압 발생을 위한 펌프 출력 제어부와 산업용 통신을 위한 CAN 통신, 이터넷 통신, UART 통신, USB를 사용하였다. 수위의 변화를 통해 압력의 변화를 확인하였으며, 압력의 변화를 최소화하여 액적 토출을 위한 시스템을 구현하였다.

에어챔버가 설치된 인라인 취수펌프장에서 수격현상 (Waterhammer for the In-Line Intake Pumping Station with Air Chamber)

  • 김경엽;안철홍;김범준
    • 한국유체기계학회 논문집
    • /
    • 제15권6호
    • /
    • pp.70-76
    • /
    • 2012
  • Recently, because people are taking a great interest in the water supply system and the related facilities are getting larger, the surge suppression is very important problem. The waterhammer occurs when the pumps are started or stoped for operation or tripped due to the power failure. As the waterhammer problems as a result of the pump power failure were very serious, these situations were carefully investigated. Accordingly, we carried out both numerical simulations and field tests to confirm the safety of Juam intake pumping station in which had the in-line pumps. In this paper, it was reviewed that the water supply system has the reliability on the pressure surge, in case the air chambers were installed at both the inlet and the oulet of the in-line pumping station. From the numerical simulations, we found that negative pressure occurred at the inlet disappeared and high pressure occurred at the outlet reduced due to the air chambers. And these results of numerical simulations verified by the field tests. The field tests carried out in case of normal start, normal stop, one and two of pumps emergency stop. By results of simulations and field tests, we are sure that Juam intake pumping station in which have the air chambers is safe for the waterhammer. In addition, we suggested the operation methods of facilities for safe maintenance of the pumping station.

1 MW급 유기랭킨 사이클 시스템 개발 (Development of 1MW Organic Rankine Cycle System)

  • 박흥수;조한창;이용국
    • 에너지공학
    • /
    • 제10권4호
    • /
    • pp.318-326
    • /
    • 2001
  • 중저온 배열회수를 통해 열설비의 열효율을 향상시키기 위하여 1 MW급 유기랭킨사이클시스템을 설계, 개발하였다. 포항제철소에 있는 두 대의 100 MW급 기력발전소에서 발생하는 175$^{\circ}C$의 배가스를 산업체에서 발생하는 대표적인 중저온배열원으로 선정하고, 환경오염을 최소화할 수 있는 신냉매인 HCFC-123을 시스템의 작동유체로 선정하였다. 유기냉킨사이클시스템의 시험운전을 통하여 유기랭킨사이클시스템이 산업체의 중저온배열을 회수하는데 유용함을 확인하였다. 열수의 가열, 터빈기동 및 전기투입방법 등의 운전방법을 최적화하였다. 그러나 HCFC-123 공급펌프의 능력부족으로 작동유체의 공급이 부족하여 정격출력보다 낮은 670kW의 전력을 생산할 수 있었다. HCFC-123의 공급유량을 증가시키기 위하여 파이프의 압력손실저하 및 펌프의 성능 향상을 위한 펌프교체 등이 고려되어야 함을 알 수 있었다.

  • PDF

Irradiation of Intense Characteristic X-rays from Weakly Ionized Linear Plasma

  • Sato, Eiichi;Hayasi, Yasuomi;Tanaka, Etsuro;Mori, Hidezo;Kawai, Toshiaki;Takayama, Kazuyoshi;Ido, Hideaki
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.396-399
    • /
    • 2002
  • Intense quasi-monochromatic x-ray irradiation from the linear plasma target is described. The plasma x-ray generator employs a high-voltage power supply, a low-impedance coaxial transmission line, a high-voltage condenser with a capacity of about 200 nF, a turbo-molecular pump, a thyristor pulse generator as a trigger device, and a flash x-ray tube. The high-voltage main condenser is charged up to 55 kV by the power supply, and the electric charges in the condenser are discharged to the tube after triggering the cathode electrode. The x-ray tube is of a demountable triode that is connected to the turbo molecular pump with a pressure of approximately 1 mPa. As electron flows from the cathode electrode are roughly converged to the molybdenum target by the electric field in the tube, the weakly ionized plasma, which consists of metal ions and electrons, forms by the target evaporating. In the present work, the peak tube voltage was almost equal to the initial charging voltage of the main condenser, and the peak current was about 20 kA with a charging voltage of 55 kV. When the charging voltage was increased, the linear plasma x-ray source grew, and the characteristic x-ray intensities of K-series lines increased. The quite sharp lines such as hard x-ray lasers were clearly observed. The quasi-monochromatic radiography was performed by a new film-less computed radiography system.

  • PDF

한국형발사체 연료 동시충전을 위한 유량제어 방식에 대한 고찰 (Analysis on Flow Control Method for Simultaneous Fuel Filling of the Korea Space Launch Vehicle-II)

  • 여인석;이재준;안재철;강선일
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.5-13
    • /
    • 2017
  • 한국형발사체 발사를 위하여 나로우주센터에 제 2발사대가 구축될 예정이며 연료공급설비 역시 새롭게 설치된다. 한국형발사체 발사대시스템의 연료공급설비는 나로호 발사대의 설계를 기본 바탕으로 하였다. 하지만 한국형발사체는 나로호 또는 시험발사체와는 달리 3단형 발사체이기 때문에 연료 이송펌프 1대로 1, 2, 3단의 발사체 연료 탱크로 연료를 공급해야한다. 유동해석을 통해 충전 시나리오를 선정하는 과정에서 펌프 토출압력의 급격한 상승 문제를 확인하였다. 이는 오리피스타입의 유량제어방식으로 각 단의 충전모드 전환에 따른 유량변화에 대해 리턴유량이 능동적으로 대응할 수 없기 때문에 발생하였다. 이 문제를 해결하기 위해 다양한 경우에 대해 유동해석을 통해 accumulator 설치와 각 단의 충전모드 전환 순서를 적절히 조정함으로써 안정적으로 공급할 수 있음을 확인하였다.

  • PDF

한국형발사체 연료 동시충전을 위한 유량제어 방식에 대한 고찰 (Analysis on Flow Control Method for Simultaneous Fuel Filling of the Korea Space Launch Vehicle-II)

  • 여인석;이재준;안재철;강선일
    • 한국추진공학회지
    • /
    • 제22권5호
    • /
    • pp.132-140
    • /
    • 2018
  • 한국형발사체 발사를 위하여 나로우주센터에 제 2발사대가 구축될 예정이며 연료공급설비 역시 새롭게 설치된다. 한국형발사체 발사대시스템의 연료공급설비는 나로호 발사대의 설계를 기본 바탕으로 하였다. 하지만 한국형발사체는 나로호 또는 시험발사체와는 달리 3단형 발사체이기 때문에 연료 이송펌프 1대로 1, 2, 3단의 발사체 연료 탱크로 연료를 공급해야한다. 유동해석을 통해 충전 시나리오를 선정하는 과정에서 펌프 토출압력의 급격한 상승 문제를 확인하였다. 이는 오리피스타입의 유량제어방식으로 각 단의 충전모드 전환에 따른 유량변화에 대해 리턴유량이 능동적으로 대응할 수 없기 때문에 발생하였다. 이 문제를 해결하기 위해 다양한 경우에 대해 유동해석을 통해 accumulator 설치와 각 단의 충전모드 전환 순서를 적절히 조정함으로써 안정적으로 공급할 수 있음을 확인하였다.

공업용수 공급시스템의 효율적인 운영을 위한 시스템다이내믹스 모형의 개발 (Development of a System Dynamics Computer Model for Efficient Operations of an Industrial Water Supply System)

  • 김봉재;박수완;김태영;전대훈
    • 상하수도학회지
    • /
    • 제26권3호
    • /
    • pp.383-397
    • /
    • 2012
  • In this study, a System Dynamics (SD) simulation model for the efficient operations of an industrial water supply system was developed by investigating the feedback loop mechanisms involved in the operations of the system. The system was modeled so that as demand is determined the water supply quantity of intake pumping stations and dams are allocated. The main feedback loop showed that many variables such as the combinations of pump operation, unit electric power(kWh/$m^3$), unit electric power costs(won/$m^3$), water level of water way tunnel, suction pressure and discharge of pumping station, and tank and service reservoir water level had causal effects and produced results depending on their causal relationship. The configurations of the model included an intake pumping station model, water way tunnel model, pumping station model (including the tank and service reservoir water level control model), and unit electric power model. The model was verified using the data from the case study industrial water supply system that consisted of a water treatment plant, two pumping stations and four dams with an annual energy costs of 5 billion won. It was shown that the electric power costs could have been saved 7~26% during the past six years if the operations had been based on the findings of this study.

A FLOW AND PRESSURE DISTRIBUTION OF APR+ REACTOR UNDER THE 4-PUMP RUNNING CONDITIONS WITH A BALANCED FLOW RATE

  • Euh, D.J.;Kim, K.H.;Youn, Y.J.;Bae, J.H.;Chu, I.C.;Kim, J.T.;Kang, H.S.;Choi, H.S.;Lee, S.T.;Kwon, T.S.
    • Nuclear Engineering and Technology
    • /
    • 제44권7호
    • /
    • pp.735-744
    • /
    • 2012
  • In order to quantify the flow distribution characteristics of APR+ reactor, a test was performed on a test facility, ACOP ($\underline{A}$PR+ $\underline{C}$ore Flow & $\underline{P}$ressure Test Facility), having a length scale of 1/5 referring to the prototype plant. The major parameters are core inlet flow and outlet pressure distribution and sectional pressure drops along the major flow path inside reactor vessel. To preserve the flow characteristics of prototype plant, the test facility was designed based on a preservation of major flow path geometry. An Euler number is considered as primary dimensionless parameter, which is conserved with a 1/40.9 of Reynolds number scaling ratio. ACOP simplifies each fuel assembly into a hydraulic simulator having the same axial flow resistance and lateral cross flow characteristics. In order to supply boundary condition to estimate thermal margins of the reactor, the distribution of inlet core flow and core exit pressure were measured in each of 257 fuel assembly simulators. In total, 584 points of static pressure and differential pressures were measured with a limited number of differential pressure transmitters by developing a sequential operation system of valves. In the current study, reactor flow characteristics under the balanced four-cold leg flow conditions at each of the cold legs were quantified, which is a part of the test matrix composing the APR+ flow distribution test program. The final identification of the reactor flow distribution was obtained by ensemble averaging 15 independent test data. The details of the design of the test facility, experiment, and data analysis are included in the current paper.