• Title/Summary/Keyword: Pump Module

Search Result 94, Processing Time 0.032 seconds

A Study of the Localization Development of Cryogenic Submerged Pump for the Fuel Supply system of 600-Liter-Grade LNG Vehicles (600L급 LNG 차량 연료공급용 초저온 액중펌프 국산화개발에 관한 연구)

  • Kim, Yong Gil;Kim, Do Hyun;Lee, Won Young;Yi, Chung Seob
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.4
    • /
    • pp.113-118
    • /
    • 2021
  • In this study, localized development of a submerged cryogenic pump for use in LNG containers is conducted with large-sized commercial vehicles as the target. The submerged pump installed in an LNG storage container is the key module that supplies fuel to the engine through the reciprocating motion of a piston. Research and development on 660-L fuel containers is performed herein. The target is to achieve a mileage of 600 km or more by applying it to major NGV vehicles worldwide. In this manner, the present study aims to verify the operating mechanisms of the major parts of currently advanced products through reverse engineering in the early development process and draw basic design data.

A DC-DC Converter Design with Internal Capacitor for TFT-LCD Driver IC (TFT -LCD 구동 IC용 커패시터 내장형 DC-DC 변환기 설계)

  • Lim Gyu-Ho;Kang Hyung-Geun;Lee Jae-Hyung;Sohn Ki-Sung;Cho Ki-Seok;Baek Seung-Myun;Sung Kwan-Young;Li Long-Zhen;Park Mu-Hun;Ha Pan-Bong;Kim Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.7
    • /
    • pp.1266-1274
    • /
    • 2006
  • A non-overlap boosted-clock charge pump(NBCCP) with internal pumping capacitor, an advantageous circuit from a minimizing point of TFT-LCD driver IC module, is proposed in this paper. By using the non-overlap boosted-clock swinging in 2VDC voltage, the number of pumping stages is reduced to half and a back current of pumping charge from charge pumping node to input stage is also prevented compared with conventional cross-coupled charge pump with internal pumping capacitor. As a result, pumping current of the proposed NBCCP circuit is increased more than conventional cross-coupled charge pump, and a layout area is decreased. A proposed DC-DC converter for TFT-LCD driver IC is designed with $0.18{\mu}m$ triple-well CMOS process and a test chip is in the marking.

Design and Fabrication of PZT Disc Actuated Micro Pump for Bio-Applications (II): Optimal Design & Fabrication of Embedding-type PZT Module (바이오용 압전디스크방식 마이크로 펌프 설계 및 제작 (II) -임베드방식의 압전모듈의 최적설계 및 제작-)

  • Kim, Hyung-Jin;Chang, In-Bae;Seo, Young-Ho;Kim, Byeong-Hee
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.3
    • /
    • pp.362-367
    • /
    • 2012
  • Though a micro pump is a crucial element in miniaturized bio-fluidic systems or drug delivery systems, most of the conventional micro pumps still have some limitations to miniaturize their controller system and to obtain the sufficient back pressure which can rise over the inner pressure of human body or experimental animals. In this paper, to overcome these limitation, a new PZT disc and its controller were designed and fabricated to get the sufficient flowrate and the back pressure with guaranteeing embeddability of the controller into pumping body. The amplitudes of the disc deflections were as large as 40 ${\mu}m$ at 200 V - 100 Hz condition. As results of experiments, the flow rate and the back pressure increase when the frequency increases. The obtainable maximum flow rate and back pressure are 5.2 ml/min at 95 Hz and 13.14 kPa at 90 Hz respectively.

A study on the Heat Transfer Performance according to Ground Heat Exchanger Types (지중열교환기의 종류에 따른 열전달 성능에 관한 연구)

  • Hwang, SuckHo;Song, Doosam
    • KIEAE Journal
    • /
    • v.10 no.4
    • /
    • pp.75-80
    • /
    • 2010
  • Generally, ground-source heat pump (GSHP) systems have a higher performance than conventional air-source systems. However, the major fault of GSHP systems is their expensive boring costs. Therefore, it is important issue that to reduce initial cost and ensure stability of system through accurate prediction of the heat extraction and injection rates of the ground heat exchanger. Conventional analysis methods employed by line source theory are used to predict heat transfer rate between ground heat exchanger and soil. Shape of ground heat exchanger was simplified by equivalent diameter model, but these methods do not accurately reflect the heat transfer characteristics according to the heat exchanger geometry. In this study, a numerical model that combines a user subroutine module that calculates circulation water conditions in the ground heat exchanger and FEFLOW program which can simulate heat/moisture transfer in the soil, is developed. Heat transfer performance was evaluated for 3 different types ground heat exchanger(U-tube, Double U-tube, Coaxial).

An Experimental Study on the Load Delivery Characteristics of Hybrid Energy System with Geothermal and Solar Heat Sources (지열-태양열원 복합시스템의 부하추종특성에 관한 실험 연구)

  • Hwang, In-Ju;Woo, Nam-Sub
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.2 no.2
    • /
    • pp.1-8
    • /
    • 2006
  • The objective of the present study is to investigate the load delivery characteristics of a hybrid-renewable energy system with geothermal and solar heat sources for hot water, heating and cooling of a residential house in Korea. The hybrid energy system consists of ground source heat pump of 2 RT for cooling with a 150 m vertical U-bend ground heat exchanger, solar collectors of 4.8 m2 and gas fired backup boiler. The averaged coefficient of performance of geothermal module during cooling and heating seasons are evaluated as about 4.5 and 3.8, respectively.

  • PDF

Development of a Real-Time Steady State Detector of a Heat Pump System to Develop Fault Detection and Diagnosis System (열펌프의 고장진단시스템 구축을 위한 정상상태 진단기 개발)

  • Kim, Min-Sung;Yoon, Seok-Ho;Kim, Min-Soo
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2070-2075
    • /
    • 2008
  • Identification of steady-state is the first step in developing a fault detection and diagnosis (FDD) system. In a complete FDD system, the steady-state detector will be included as a module in a self-learning algorithm which enables the working system's reference model to "tune" itself to its particular installation. In this study, a steady-state detector of a residential air conditioner based on moving windows was designed. Seven representing measurements were selected as key features for steady-state detection. The optimized moving window size and the feature thresholds was suggested through startup transient test and no-fault steady-state test. Performance of the steady-state detector was verified during indoor load change test. From the research, the general methodology to design a moving window steady-state detector was provided for vapor compression applications.

  • PDF

Soot Generation System Utilizing High-Temperature Furnace (고온로를 이용한 매연발생장치)

  • Cho, Sanghwan;Park, Sunho;Nam, Younwoo;Choi, Yoo youl;Lee, Wonnam
    • 한국연소학회:학술대회논문집
    • /
    • 2013.06a
    • /
    • pp.55-58
    • /
    • 2013
  • A new soot particle generation system has been developed and tested. The soot generation system consists of two sections, a fuel supply and a soot production. In the fuel supply module, either liquid fuel precisely controlled by a syringe pump is mixed with preheated carrier gas and rapidly evaporated or gaseous fuel controlled by a MFC is diluted with dilution gas. The soot production module contains a heater that can raise the gas/fuel temperature up to $1400^{\circ}C$. The physical and chemical properties of produced soot particles depend on the type and concentration of fuel, the residence time, and temperature in the soot production section. The soot generation system will be utilized to produce well-defined soot particles for soot studies such as the evaluation of experimental sampling and analysis processes for the quantitative assessment of PM and BC from ships and the adverse health effects on pulmonary and cardiovascular systems of human body.

  • PDF

조합(게터+이온)펌프의 배기속도

  • Park, Jong-Do;Ha, Tae-Gyun;Kim, Se-Hyeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.240-240
    • /
    • 2013
  • PLS-II 저장링 진공시스템의 주 배기 장치로 설치되어 운용되고 있는 조합펌프(NEG+이온펌프)의 성능을 측정하였다. 이 조합펌프는 60 l/s 또는 30 l/s의 이온펌프와 WP950 (ZrVFe) getter module (1~3개)로 구성되어 있다. 이 펌프의 배기속도를 활성화 방법에 따라 측정하여 성능을 검증하고 재활성화 빈도, 흡착률을 실험적으로 측정하였다. 배기속도는 수소, 일산화탄소, 수소+일산화탄소의 혼합기체를 사용하여 측정하여 보고하고자 한다.

  • PDF

Layout Optimization of FPSO Topside High Pressure Equipment Considering Fire Accidents with Wind Direction (풍향에 따른 화재영향을 고려한 FPSO 상부구조물 고압가스 모듈내부의 장비 최적배치 연구)

  • Bae, Jeong-Hoon;Jeong, Yeon-Uk;Shin, Sung-Chul;Kim, Soo-Young
    • Journal of Ocean Engineering and Technology
    • /
    • v.28 no.5
    • /
    • pp.404-410
    • /
    • 2014
  • The purpose of this study was to find the optimal arrangement of FPSO equipment in a module while considering the economic value and fire risk. We estimated the economic value using the pipe connections and pump installation cost in an HP (high pressure) gas compression module. The equipment risks were also analyzed using fire scenarios based on historical data. To consider the wind effect during a fire accident, fuzzy modeling was applied to improve the accuracy of the analysis. The objective functions consisted of the economic value and fire risk, and the constraints were the equipment maintenance and weight balance of the module. We generated a Pareto-optimal front group using a multi-objective GA (genetic algorithm) and suggested an equipment arrangement method that included the opinions of the designer.

Demonstration of system to combat desertification using renewable energy (신재생에너지를 이용한 사막화 방지 시스템 실증 (몽골))

  • Kim, Man-Il;Lee, Seung-Hun;Whang, Jung-Hun;Cho, Woon-Sic;Park, Moon-Hee
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.73-76
    • /
    • 2009
  • Generally, wind or solar power system is operated as a stand-alone power system, the efficiency of which could be higher by designing wind-solar combined system considering average wind speed and solar radiation of the desert region, Mongolia. This system is designed to generate electricity for power users and pumps the ground water for irrigation using deep well pump. The ground water can be used for farming or forestation where there is no or little irrigation system. In connection with this study, a renewable energy park, Green Eco Energy Park, was developed at about 50km east of Ulaanbaatar. 3 sets of 10kW wind power generator and 70 kW of solar power module were installed there. The electricity generated from the system is used to on-site office building and deep well pump for ground water pumping. A 10kW stand-alone solar pumping system, which has no rechargeable battery system, is installed to pump the ground water with the amount of generated power. The ground water is stored in 3 artificial ponds and then it is used for raising nursery tree and farming. The purpose of this study is to provide a possible energy solution to desert regions where there is no or little power system. The system also supply power to ground water pump, and the water can be used for farming and forestation, which will also be a solution of preventing desertification or spreading of desert area.

  • PDF