• Title/Summary/Keyword: Pulsed operation

Search Result 124, Processing Time 0.033 seconds

Gate Driver for Power Cell Driving of Bipolar Pulsed Power Modulator (양극성 펄스 파워 모듈레이터의 파워셀 구동을 위한 게이트 드라이버)

  • Song, Seung-Ho;Lee, Seung-Hee;Ryoo, Hong-Je
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.2
    • /
    • pp.87-93
    • /
    • 2020
  • This study proposes a gate driver that operates semiconductor switches in the bipolar pulsed power modulator. The proposed gate driver was designed to receive isolated power and synchronized signals through the gate transformer. The gate circuit has a separate delay in the on-and-off operation to prevent a short circuit between the top and bottom switches of each leg. On the basis of the proposed gate circuit, a bipolar pulsed power modulator prototype with a 2.5 kV/100 A rating was developed. Finally, the bipolar pulsed power modulator was tested under resistive load and plasma reactor load conditions. It is verified that the proposed gate driver can be applied to a bipolar pulsed power modulator.

Neutronic and thermohydraulic blanket analysis for hybrid fusion-fission reactor during operation

  • Sergey V. Bedenko ;Igor O. Lutsik;Vadim V. Prikhodko ;Anton A. Matyushin ;Sergey D. Polozkov ;Vladimir M. Shmakov ;Dmitry G. Modestov ;Hector Rene Vega-Carrillo
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2678-2686
    • /
    • 2023
  • This work demonstrates the results of full-scale numerical experiments of a hybrid thorium-containing fuel plant operating in a state close to critical due to a controlled source of D-T neutrons. The proposed facility represented a level of generated power (~10-100 MWt) in a small pilot. In this work, the simulation of the D-T neutron plasma source operation in conjunction with the facility blanket was performed. The fission of fuel nuclei and the formation of spatial-energy release were studied in this simulation, in pulsed and stationary modes of the facility operation. The optimization results of neutronic and fluid dynamics studies to level the emerging offsets of the radial energy formed in the volume of the facility multiplying part due to the pulsed operation of the D-T neutron plasma source were presented. The results will be useful in improving the power control-based subcriticality monitoring method in coupled systems of the "pulsed neutron source-subcritical fuel assembly" type.

Analysis of Power Supply System for 8.5 MVA Magnetic Power Supply Using EI (EMTDC를 이용한 8.5 MVA급 Magnetic Power Supply의 전력공급 시스템 분석)

  • Jeong, Yong-Hoo;Nho, Eui-Cheol;Kim, In-Dong;Choi, Jung-Wan
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1114-1116
    • /
    • 2002
  • The characteristics of voltage drop and THD for parallel operating 11 PCRs (Phase Controlled Rectifiers) are analysed. The PCRs are used to drive high current (1.6 kA ${\sim}$ 3.7 kADC) electromagnetic coils for electromagnets. All the PCRs operate simultaneously in pulsed mode, and the pulse shot occurs every 150 seconds. During the pulse operation the PCR output current ramps up for 4 seconds, and then keeps flat top state for 2 seconds, and finally ramps down for 4 seconds. For the flat top mode a severe voltage drop and distortion appear in the power system because transformers for the PCRs are designed considering pulsed mode operation. It is expected that the analysis method can be applied to improve the system performance including power factor and design of high power pulsed mode operating power supply systems.

  • PDF

A Study on Characteristics of Light Triggered Thyristor for Pulsed Power Application (펄스전력용 광점호 싸이리스터의 특성 연구)

  • Lee, Byung-Ha;Kim, Jin-Sung;Kim, Young-Bae;Cha, Han-Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.4
    • /
    • pp.762-767
    • /
    • 2010
  • This paper describes characteristic of a light triggered thyristor investigated by experiment to adopt it into a main switch of a pulsed power unit. Triggering principle of the light triggered thyristor are referred with its structure and equivalent circuit. Operational principle and simulation result of a capacitive pulsed power circuit are explained. A variety of triggering conditions of triggering circuit and characteristics on turn-on, turn-off, voltage dividing in series operation, overvoltage protection function of the light triggered thyristor are investigated by experiments. Experimental result of 40 kJ pulsed power unit using the light triggered thyristor is presented.

Development of Current Sensor for Pulsed Power and its Characteristics Evaluation (펄스파워 전류 측정용 센서 개발 및 특성 평가)

  • Han, Sang-Bo
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.230-234
    • /
    • 2019
  • This paper shows the development of current sensor for the measurement of hundreds of nanoseconds large current in pulsed power and its characteristics evaluation. The developed current sensor was designed for measuring induced voltage from magnetic flux under the operation of pulsed power. Output characteristics of developed current sensor was good consistent with commercial one, and the realistic current of fast pulsed power was detected easily with the calibration curve using output voltage of developed sensor. Therefore, the developed current sensor is possible to apply the realistic system.

The Experiment of High Voltage Capacitor Charger for Pulsed Power Application (펄스전원용 고압커패시터 충전기 시험)

  • Jang, S.R.;Ahn, S.H.;Ryoo, H.J.;Kim, J.S.;Kim, Y.B.;Kim, J.S.;Lee, B.H.;Kim, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1025_1026
    • /
    • 2009
  • This paper introduces the test a rapid pulsed power charging system for pulsed power application. The charger is designed based on three-phase series resonant inverter followed by air cooled step-up transformers. It has many advantages of lower weight, small size and high efficiency compared with large bulky traditional pulse power charging system. To apply 150kJ pulsed power system, detail test was carried out at various condition and its results shows 90% efficiency at full load condition. And additional experiments such as short, open, and self discharging during charging status are performed to verify reliable operation at abnormal condition and it was confirmed that developed capacitor charger showed very reliable operation all over the tests.

  • PDF

DESIGN AND TEST RESULTS ON A 45-KV PULSED POWER MODULATOR FOR A 1.5-MW MAGNETRON APPLICATION OF KSTAR LHCD

  • Jang, Sung-Duck;Son, Yoon-Gyu;Oh, Jong-Seok;Bae, Young-Soon;Cho, Moo-Hyun;NamKung, Won
    • Nuclear Engineering and Technology
    • /
    • v.38 no.8
    • /
    • pp.785-792
    • /
    • 2006
  • The microwave heating system of KSTAR consists of ECH and LHCD. ECH and LHCD offer the benefits ofa reliable operation at the start of plasma formation and a non-inductive current drive durable steady state operation, respectively. LHCD uses a C-band microwave system with a frequency of 5 GHz. A pulsed power modulator with a power of 3.6 MW, $4{\mu}S$, 200 pps is required to drive the high-powered magnetron. The development of a pulse modulator with 1:4 pulse transformers is the focus of the research in this study. The peak power handling capability is 3.6 MW (45 kV, 90 A at load side with a pulse width of $4{\mu}S$). This paper describes the system overview and test results of the pulsed modulator. In particular, a simulated waveform is compared with the tested waveform.

The Effects of Pulsed Electromagnetic Field on Functional Recovery and Expression of GAP-43 after Incomplete Spinal Cord Injury in Rats (맥동전자장이 불완전 척수손상 흰쥐의 기능회복과 GAP-43의 발현에 미치는 영향)

  • Bang, Hyun-Soo
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.7 no.3
    • /
    • pp.349-356
    • /
    • 2012
  • Purpose : This study was designed to investigate the effects of pulsed electromagnetic field on functional recovery and expression of GAP-43 after incomplete spinal cord injury (SCI) in rats. Methods : To confirm the damage of SCI and effects of pulsed electromagnetic field, 20 Sprague-Dawley male rats were used and divided randomly 2groups (SCI, PEMF). Incomplete SCI was induced by using modified NYU drop model. After operation, functional recovery test, immunohistochemistry and western blot analysis were measured at 1, 2, 3 weeks. Pulsed electromagnetic field were apply three weeks (one times a day, five days a week and twenty minutes a session). Results : In the this study, applications of pulsed electromagnetic field after incomplete SCI induced the significant improvement in functional recovery and expression of neurotrophic factor. The results were as follows; Foot print test, PEMF were significantly decreased than the SCI (p<.05). Expression of GAP-43, PEMF were significantly increased than the SCI at 2 and 3 weeks (p<.05). Conclusion : In conclusion, pulsed electromagnetic field were positive effect in functional recovery and expression of GAP-43 after incomplete SCI in rats.

Current Sensorless Control of the Voltage Bus Conditioner for a DC Power System with Parallel Pulsed Power Loads (병렬 펄스 부하를 갖는 직류 전력시스템을 위한 Voltage Bus Conditioner의 전류 센서 없는 제어)

  • Lee, Byung-Hun;Chang, Han-Sol;La, Jae-Du;Kim, Young-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.11
    • /
    • pp.1617-1624
    • /
    • 2012
  • A DC power system has many loads with varied functions. Also, there may be large pulsed loads with short duty ratios which can affect the normal operation of other loads. In this paper, Voltage Bus Conditioner(VBC) without any current sensors is proposed to damp the bus voltage transients by parallel pulsed loads. The proposed control approach requires only one voltage sensor and carries out both the functions of damping the bus voltage transients and maintaining the level of energy stored. The proposed control technique has been implemented on a TMS320F2812 Digital Signal Processor(DSP). Simulated results by a Matlab Simulink and experimental results are presented which verify the control principles and demonstrate the practicalty of the approach.

A Development of the X-Band 63 Watt Pulsed SSPA for Radar (레이더용 X-대역 63 Watt Pulsed SSPA 개발)

  • Chong, Min-Kil;Na, Hyung-Gi
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.3
    • /
    • pp.380-388
    • /
    • 2011
  • In this paper, we developed the X-band 63 watt pulsed SSPA(Solid State Power Amplifier) by using HMIC(Hybrid Microwave Integrated Circuits). The pulsed SSPA consists of power supply and 3-stage amplifier modules : pre-amplifier stage, driver-amplifier stage, final-amplifier stage. The developed pulsed SSPA provides more than 63 watts of output power with a short pulse width and the duty cycle of up to 1.2 % at $70^{\circ}C$. The fabricated module offers great than 37 dB of saturated gain across the operating band. Input and output VSWR is <1.5:1. This module has an average current of 400 mA typical and operates at a +28 $V_{dc}$ supply. The developed SSPA in this paper can apply to pulsed Doppler radar with high speed operation.