• Title/Summary/Keyword: Pulsed corona discharge

Search Result 33, Processing Time 0.03 seconds

Effect of Propene($C_3H_6$) ON NO-$NO_2$ Conversion Process in a Pulsed Corona Discharge (펄스코로나 방전에서 프로핀($C_3H_6$)이 NO-$NO_2$ 변환에 미치는 영향에 관한 연구)

  • 박광서;전배혁;전광민
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.5
    • /
    • pp.67-77
    • /
    • 2000
  • Investigated was the effect of propene(C3H6) on the NO-NO2 conversion in dry exhaust gases from lean burn engine using a pulsed corona discharge. A kinetic model was developed to characterize the plasma chemistry in simulated exhausts containing propene. The model uses ELENDIF program to solve Boltzmann equation for electron energy distribution function, and CHEMKIN-II program to solve stiff ODE(ordinary differential equation) problems for species concentrations. The corona discharge energy per pulse and the time-space averaged E/N were obtained by fitting the model to experimental data. The model calculation shows good agreement for NO and NO2 concentrations with the experimental data, and predicts the formation of byproducts such as CH2O, CH3HCO, CO AND CH3NO2 Propene enhances the NOx conversion enormously at lower energy density and the NOx conversion increases with the increase of initial propene and oxygen concentration, and temperature.

  • PDF

Removal of NOx by Pulsed Streamer discharge (펄스 스트리머 방전을 이용한 NOx 제거)

  • 고희석;박재윤;김건호
    • Electrical & Electronic Materials
    • /
    • v.10 no.8
    • /
    • pp.807-811
    • /
    • 1997
  • In this paper we have investigated the removal characteristics of NOx by pulsed corona discharge with a multi-pointplane electrode where a magnetic field is applied in the discharge region. The efficiency of NOx removal was measured and analyzed as a function of pulse frequency gas flow rate NOx initial concentration magnetic flux density. In this result the highest removal efficiency of NOx was obtained at the following operating conditions; the frequency =400[Hz] gas flow =1[$\ell$/min] initial concentration= 400[ppm] and magnetic flux density=0.36[T].

  • PDF

Study on the Reduction of Energy Consumption in the Pulsed Corona Discharge Process for NOx Removal (질소산화물 제거를 위한 펄스코로나 방전공정의 에너지 소모 저감에 관한 연구)

  • 정재우;손병학;조무현;목영선;남궁원
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.4
    • /
    • pp.475-483
    • /
    • 1999
  • A lab-scale test was carried out to study the reduction of electrical energy consumption in the pulsed corona discharge process for nitrogen oxides removal. The experiment was mainly focused on 1) the activation of pollution removal reactions by chemical additives and 2) the optimization of electrical circuit for the efficient energy transfer from the power supply to the corona reactor. Hydrocarbon chemical additives used in the experiment are thought to be responsible for the enhancement of the NO conversion through the chain reactions of free radicals such as, R, RCO, and RO. Electrical energy consumption per converted NO molecule has a minimum value of 17 eV when pentanol is injected. When ethylene and propylene are injected, 30 eV and 22 eV of electrical energy consumption is required for the conversion of NO molecule respectively. The ratio of the pulse forming capacitance$(C_e)$ to the reactor capacitance$(C_R)$ plays an important role in the energy transfer efficiency to the reactor. Maximum energy transfer efficiency of approximately 72% could be obtained by using the pulse forming capacitance which is 3.4 times larger than the reactor capacitance, and also the maximum NO conversion efficiency was observed with the same condition.

  • PDF

A Study on the Removal of SOx/NOx by a Pulsed Corona Discharge in the Wire-Plate Reactor (Wire-Plate 반응기에서 펄스 코로나 방전을 이용한 탈황 탈질에 관한 연구)

  • Shin, Wan-Ho;Song, Yong-Hoon;Kim, Han-Seok;Choi, Yeon-Seok;Kim, Seok-Joon
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1910-1912
    • /
    • 1996
  • This paper presents the results of laboratory experimentals to remove $SO_2$ and $NO_x$ by a pulsed corona discharge in the wire-plate reactor. A rotating spark gap switch was used to generate the pulse by chewing the dc high voltage. Repetition frequency of the pulse was 60Hz and rising time of 50ns. The photo pictures of positive streamer corona taken by ICCD camera, pulse voltage and current were measured using a digital oscilloscope. Simultaneous effects of $C_{2}H_{4}$ injection and heterogeneous chemical reactions on nonthermal plasma process to remove $SO_2$ and $NO_x$ from flue gas were investigated in the present study

  • PDF

Test Results of Pulsed Power Supply for Nonthermal Plasma Process (저온 플라즈마 공정용 펄스발생 전원장치의 성능시험)

  • Jang, S.D.;Byun, Y.C.;Cho, M.H.;Shin, D.N.
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1574-1575
    • /
    • 2011
  • The application of a pulsed power system is being extended to an environmental and industrial field. The non-destructive gaseous pollutants from industrial plants such as power generation plants and incinerators can be processed by applying high voltage pulses with a fast rising time (a few nanoseconds) and short duration (nano to microseconds) in a pulsed corona discharge reactor. The pulsed plasma generator with a triggered switch has been developed. Its corona current in load can be adjusted by applied voltage and repetition rate. We investigated the performance of the pulsed plasma generator by analyzing the concentration of ozone in small reactor. This paper describes the electrical characteristics of the pulse generator with a voltage of 30 kV at repetition rate of 50 PPS. In addition, we briefly discuss a configuration of the system and initial test results.

  • PDF

Technical Development of Flue Gas Control at Commercial Plant Using the Non-thermal Plasma Process (저온 플라즈마 공정을 이용한 상용설비의 배연가스 처리 기술개발)

  • Yoo, J.S.;Paek, M.S.;Kim, T.H.;Kim, J.I.;Kim, Y.S.;Choi, S.H.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.939-944
    • /
    • 2001
  • For the application of simultaneous $DeSO_{2}\;&\;DeNO_{x}$ equipment using non-thermal plasma process to the industrial and power plants, the many types of plasma device and process were studied. The e-beam and pulsed plasma corona discharge process are outstanding for the study to apply commercial large-scale plant from among these. In this paper, non-thermal plasma of technical trends and the characteristics of system developed by Doosan heavy industries & construction Co., Ltd. are explained. We have researched pulsed plasma corona discharge process since 1994. At the basis of reasonable results for the pilot plant, we constructed the demonstration plant at a domestic coal-fired power plant in 1999, as the previous step for commercial use. In near future, enough information about designs and costs of commercial-size system will be obtained.

  • PDF

A Study on the Energy Efficiency for NO Removal by Pulsed Corona Discharge (펄스 코로나 방전을 이용한 NO제거 에너지 효율에 대한 연구)

  • Kang, Hun;Song, Bong-Shik;Lee, Seok-Hyun;Doh, Hyun-Ho;Kim, Youn-Teag
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2010-2012
    • /
    • 1999
  • The product of electrons by Pulsed Corona Discharge leads to produce radicals which work on NO, and NO is finally removed. Energy efficiency for NO removal was improved with increasing peak voltage rather than with increasing pulse frequency. The rate of energy transfer increased with decreasing value of $C_p$( Pulse - Forming Capacitance 2.15, 1.06, 0.55, 0.36, 0.1[nF]. When the value of $C_p$ reached to 0.36 [nF], the energy efficiency for NO removal was maximized. And good agreement was obtained between chemical kinetic calculations and the experimental results.

  • PDF

Phenol Conversion Properties in Aqueous Solution by Pulsed Corona Discharge (펄스 코로나 방전에 의한 액체상 페놀 전환 특성)

  • Lee, Hyun-Don;Chung, Jae-Woo;Cho, Moo-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.1
    • /
    • pp.40-46
    • /
    • 2007
  • A laboratory scale experiment on phenol conversion properties by pulsed corona discharge process was carried out. Effects of operating parameters such as applied voltage, input oxygen, and electrode geometry on phenol conversion and solution properties were investigated. Electrical discharges generated in liquid phase increased the liquid temperature by heat transfer from current flow, decreased the pH value by producing various organic acids from phenol degradation, and increased conductivity by generating charge carriers and organic acids. The oxygen supply enhanced the phenol conversion through the ozone generation dissolution and the production of OH radicals. Series type electrode configuration induced more ozone production than reference type configuration because it produced gas phase discharges as well as liquid phase discharges. Therefore, the higher phenol conversion and TOC(total organic carbon) removal efficiency were obtained in series type configuration.

Effect of electrode coating and applied voltage of pulsed electric fields (PEF) on sludge solubilization (펄스전기장 (Pulsed Electric Fields)의 전극 코팅과 인가 전압에 따른 슬러지의 가용화 효과)

  • Um, Se-Eun;Chang, In-Soung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.10
    • /
    • pp.16-23
    • /
    • 2018
  • Alternative technologies for sludge treatment and disposal need to be developed urgently because the amount of produced production has increased continuously. In this study, Pulsed Electric Fields (PEF) technique was applied for sludge solubilization and the performance was evaluated. The PEF equipped with electrodes coated by epoxy resin and teflon was inducted to the activated sludge suspension, and the effect of the coating materials on the solubilization was determined. In addition, the effect of the applied voltage on the solubilization yield was investigated as the applied voltage was increased from 6 to 12 and 15 kV. Sludge solubilization was not observed when the epoxy-coated electrode was used for PEF induction regardless of the applied voltage. However, sludge solubilization occurred when 12 and 15 kV were applied to the teflon-coated electrodes. The MLSS decreased to 9%, and the soluble-COD increased to 496% when the applied voltage was 15 kV. But sludge solubilization did not happen under 6 kV condition. The corona discharge was observed at applied voltages of 12 and 15 kV, (Ed- sorry but I cannot understand the following highlight) but if 6 kV, strongly indicating that the corona discharge make the sludge solubilized, which suggests that the critical voltage for sludge solubilization lies between 6 and 12 kV. Consequently, proper selection of electrode-coating materials and the applied voltage of PEF could lead to sludge solubilization by corona discharge.

A Study on Improvement of the Performance of Pulsed AC Ion Bar (2) (바 형태 정전기제거장치의 정전기제거성능 향상을 위한 연구 (2))

  • Lee, Dong Hoon;Choi, Dong Soo;Kim, Sang Min;Park, Jin Chul
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.6
    • /
    • pp.40-45
    • /
    • 2014
  • In display such as LCD, LED, and AMOLED or semiconductor related industries are required to have static ionizer in order to produce reliable goods. The most general type of ionization is called, "corona discharge" that has a slight chances to generate unequal and unstable amount of each +/- ion to the target object. Then, the ionization performance will drastically decrease and end up with quality deterioration problem. continually "A study on the improvement of the performance of pulsed AC ion bar(1)", we have studied consecutive study to improve the current issue via appling "partition wall" at air nozzle surrounding. The results were that the charge decay time and the ion balance was maintained the satisfied range that was within 5 second and ${\pm}50$ V for a 180 days period of time. In additions, the contamination status on the electrode surface was investigated for a 180 days. The little particles was deposited on the electrode surface.