• Title/Summary/Keyword: Pulse-on Time

Search Result 1,713, Processing Time 0.036 seconds

Study on Machining Speed according to Parameters in Micro ECM (가공 인자에 다른 미세 전해 가공 속도 변화 연구)

  • Kwon, Min-Ho;Park, Min-Soo;Shin, Hong-Shik;Chu, Chong-Nam
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.3
    • /
    • pp.308-314
    • /
    • 2011
  • In micro electrochemical machining (micro ECM), machining conditions have been determined to maintain a small side gap and to machine a workpiece stably However, machining speed is slow. To improve machining speed while maintaining the form accuracy, the paper investigates machining parameters such as pulse amplitude, duty ratio, pulse on-time, and the electrolyte's temperature and concentration. The experiment in this study shows that the electrolyte's concentration is the key factor that can reduce machining time while maintaining the form accuracy Micro square columns were fabricated to confirm the machining parameters' effects.

Evaluation of Compressive Strength and Ultrasonic Pulse Velocity according to Elapsed Time on Normal and Lightweight Aggregate Concrete at Early Age (초기재령에서 보통 및 경량골재 콘크리트의 경과시간에 따른 압축강도 및 초음파 펄스 속도의 평가)

  • Kim, Won-Chang;Choi, Hyeong-Gil;Nam, Jeong-Soo;Kim, Gyu-Yong;Lee, Tae-Gyu
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.409-410
    • /
    • 2023
  • In this study, the compressive strength and ultrasonic pulse velocity were evaluated according to the elapsed time on concrete mixed with normal and lightweight aggregates at early age. For evaluation in various strength ranges, the design compressive strength was set to 30, 45, and 60MPa and evaluated. As a result of the experiment, the compressive strength of concrete mixed with lightweight aggregates developed 5MPa earlier compared to normal aggregate concrete, and the UPV showed a similar tendency.

  • PDF

Study on the Formation Mechanism of Hard Chrome Surface Morphology by Atomic Force Microscopy

  • Lee, B.K.;Park, Y.;Kim, Man;S.C. Kwon
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.35-35
    • /
    • 2002
  • Atomic force microscopy was applied to study the formation and growth mechanism of thin chrome layers prepared under various pulse plating conditions. The chrome was electro-deposited from an electrolyte bath containing 250 gl-l of chromic acid, 25 gl-l of sulfuric acid using direct current density of $1.6{\;}mA.$\textrm{mm}^{-2} and pulse currents with on-off time from 5 to 900 ms. The higher current density enhanced nucleation rate which resulted in refining grain size. The chrome growth kinetics determining nodule size and shape significantly depends on the duration of on-time rather than duration of off-time and on/off time ratio.

  • PDF

Real-Time Pressure-Measuring System for Evaluating the Depth of Pulse (맥진 깊이 판단을 위한 실시간 압력 측정기)

  • Cho, Jong Ho;Kim, Dae Bok;Kim, Gi Wang
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.27 no.3
    • /
    • pp.313-317
    • /
    • 2013
  • In order to standardize the pressure/depth against radial artery, the externally-applied-pressure measuring system was fabricated and evaluated. Based on the resistance-variable characteristic of the very thin($10{\mu}m$) film conductive tape along the pressure of a tip of a examiner's hand, this system was designed. The change of the pressure was processed through voltage regulator and Matlab S/W, then showed on computer monitor. The signal output through voltage regulator, and Matlab S/W was evaluated on various conditions. The evaluation was executed on these cases; an examiner slowly increases and decreases the pressure, rapidly increases and decreases the pressure, sequentially increases and decreases the pressure, sustains the pressure, micro-changes the pressure. As a pulse examiner varies the pressure on the radial artery of the examinee, the system's real-time output consistently varies according to the pressure. From the results, it is concluded that this system consistently shows the pressure of the tip of a examiner's hand in real time without interrupting the evaluation of the radial artery pulse. Therefore this system is expected to standardize the value of the pressure/depth externally applied by an examiner.

Electron Discharge Machining (EDM) and Hole EDM of Cold Heat-treated Tool Steel Molds (STD11) by using Cu Electrodes (냉간 금형용 공구강의 Cu 전극을 이용한 방전 홀에 관한 연구)

  • Park, In-Soo;Lee, Eun-Ju;Kim, Hwa-Jeong;Wang, Deok-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.4
    • /
    • pp.76-82
    • /
    • 2018
  • 3D formed Electrical Discharge Machining (EDM) and hole EDM were conducted for die and mold manufacturing with electrodes which were made by mechanical machining and wire EDM. It is difficult to machine the hardened material after heat treatment and quenching with traditional machining. The only method of machining hardened material is die-sinking EDM. In this research, hole EDM was conducted for heat-treated cold-worked tool steel (SKD11) for use as a die material. The EDM surfaces were analyzed by pulse-on time and peak current of EDM current, according to the machining conditions of EDM. The EDM surface profiles were affected by the peak current. The contribution of each factor is peak current (91.63%) and pulse-on time (0.93%). The best surface roughness was obtained with a $130{\mu}s$ pulse-on time and a 14.2 A peak current. With uniform EDM processing, the surface deteriorated with increasing pulse-on time and peak current. The thickness of the solidified layer induced by EDM was increased as the peak current, crater shapes, and erupted shapes of EDM surfaces were increased. Therefore, microcracking gaps induced by surface tension were increased.

A study on the reason that pulse-feeling method of meridians diagnosis flows into diagnostic method by taking pulse of setting six region for Chon(寸), Gwan(關) and Cheok(尺), i.e. the Chon[寸] spot pulse -A study on the transition of pulse-feeling method- (경맥진단(經脈診斷)의 맥진법(脈診法)이 기구맥(氣口脈)의 촌관척(寸關尺) 육부정위맥진법(六部定位脈診法)으로 연변(演變)된 연유(緣由)에 관(關)한 연구(硏究) -경맥학설(經脈學說) 및 맥진법(脈診法)의 상관성(相關性)-)

  • Lim, Han-je;Yoon, Jong-hwa
    • Journal of Acupuncture Research
    • /
    • v.21 no.1
    • /
    • pp.1-20
    • /
    • 2004
  • Pulse-feeling took its origin from making a diagnosis along meridians in the course of discovering and forming meridians and for a long time its meaning was mixed with meridians in the course of recognizing "The Pulse" then was separated from meridians in the early days of Western Han Dynasty. Ancient pulse-feeling methods are pulse-feeling method by the twelve regular meridians, pulse-feeling method by three regions and nine modes, pulse-feeling method by Inyeong(人迎) and Chon-gu(寸口), etc. Pulse-feeling was changed in proportion to diagnostic purpose and method of treating and if method and region of pulse-feeling is arranged, we will infer correlation between meridians and pulse-feeling and will infer transitional system of past pulse-feeling and will forecast transition of future pulse-feeling. As the result that I study the transition of the above three pulse-feeling methods of meridians diagnosis: 1. Three pulse-feeling methods of meridians diagnosis flowed into diagnostic method by taking pulse of setting six region for Chon(寸), Gwan(關) and Cheok(尺), i.e. the Chon[寸] spot pulse of $\ll$Nan-gyeong$\gg$ and were changed into diagnostic method being fit for use of five Su points, The Front-Mo points and Back-Su points that grasp the pathology of mutual internal organs and treat the disease. 2. Today it is suggesting the transition of another pulse-feeling method that do not apply diagnostic method by taking pulse of setting six region for Chon(寸), Gwan(關) and Cheok(尺), i.e. the Chon[寸] spot pulse of $\ll$Nan-gyeong$\gg$ to 19C Sasang(四象) Constitutional Medicine or 20C Eight Constitutional Medicine.

  • PDF

Field Study on Stabilization of Landfill Gas by Air Injection Mode (공기주입방식에 의한 매립지가스 안정화에 관한 현장연구)

  • Kim, Kyung;Park, Joonseok
    • Journal of the Korean GEO-environmental Society
    • /
    • v.7 no.4
    • /
    • pp.63-71
    • /
    • 2006
  • This study was conducted to evaluate air injection mode on stabilization of landfill gas and to predict the time for landfill mining. It took 8 times longer for pulse aeration to get to aerobic condition, compared to continuous aeration. It was evaluated that continuous aeration mode is more preferable than pulse mode for rapid air exchange in landfill mining. High correlation ($r^2$ = 0.95) was found between continuous aeration time and time to maintain aerobic condition when $0.2m^3/min$ of air was continuously injected and stopped. The aerobic condition ($CH_4$ < 5%) was maintained for 1.5 times longer than aeration time.

  • PDF

An Analysis Technique of Ultrasonic Pulse Signal for Measuring Ship's Draught (선박의 홀수 측정을 위한 초음파 펄스 신호의 해석기법)

  • 이은방;이상집
    • Journal of the Korean Institute of Navigation
    • /
    • v.19 no.4
    • /
    • pp.1-8
    • /
    • 1995
  • Although ship's draught information onboard is substantial for both the safety of navigation and the estimation of loaded cargoes, its accuracy depends, in conventional surveying method, on the skillfulness of observers and the condition of the sea surface round the vessel. To obtain more accurate information accessibly, measuring instruments with sophisticated sensors such as mechanical, electronic and ultrasonic transducers have been developed. However, they have still limitation in accuracy and in making up a system due to the complexity of processing signal. In this paper, we propose a new technique for analyzing ultrasonic pulse signal, in order to improve the measurement accuracy and simplify a remote sensing system of draught by ultrasonic waves. In this technique, pulse signal is translated into phase curve which is composed of the phase value defined in time domain. Then, the time interval between two signals different in waveform, is waveform, is analytically determined by calculating average time difference on phase curves. Also, analytical procedure can be carried out in real time with the successive five data sampled at T/4, for high speed digital processing with computer and A/D converter. This technique is useful for measuring draught under the influence of sea condition and for interfacing its data briefly to the integrated bridge system.

  • PDF

Effect of Number and Condition of Reflection Site on Pulse Wave (반사 지점의 개수와 조건이 맥파에 미치는 영향)

  • Lee, Min-Woo;Jang, Min;Shin, Sang-Hoon
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.1
    • /
    • pp.8-13
    • /
    • 2020
  • To develop cardiovascular simulator capable of implementing pulse waves similar to the human body, accurate information about reflection wave is required. However, the conclusion is still not clear and various discussions are underway. In this study, the pulse wave velocity of the tube used in the experiment was first determined by measuring the pressure waves at two points in a single tube system with the experimental device to implement the pulse wave transmission of blood vessels, and the superposition time and characteristics of the reflection wave were confirmed. After that, an air chamber was set at the reflection site, and the effect of the change of air volume on the reflection wave was investigated. Finally, the effect of the number of branches connected to a single tube on the reflection wave was investigated. The superposition time of the reflection wave can be controlled by the air volume of the air chamber, and the magnitude of the reflection wave is influenced by the number of reflection sites that generate the reflection wave. The results of this study may be of practical assistance to simulator researchers who want to implement pulse wave similar to clinical data. It is expected that the more results similar to clinical are provided, the greater the scope of the simulator's contribution to clinical cardiovascular research.

Propagation Characteristic Analysis of Square and Gaussian Pulse Signals on the Microstrip Line (구형 및 가우시안 펄스신호의 마이크로스트립 선로상 전파특성 해석)

  • Park, Sun-Kuen;kim, Nam;Rhee, Sung-Yup;Choi, Jung-Hyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.7 no.5
    • /
    • pp.384-394
    • /
    • 1996
  • The propagation properties of square and Gaussian pulse signals on the microstrip line are investigated by using proper conventional models to meet the frequency range of a pulse, accuracy, and geometrical requirements of the microstrip line. Numerical integration technique which has its accuracy and is easily simulated, is used to obtain the time domain response of pulse signals. The dispersion of pulse signals is analyzed regarding to the relative permittivity $\varepsilon_r$, substrate height h, strip width w of the microstrip line and pulse width $\tau$ of signal pulse. The simulation results show that small relative permittivity and small rationale of w/h are advantageous for the dispersion of the pulse signals, and that pulse signals with small bandwidth cause smaller dispersion. The results of this paper are compatible to the trade-off determination of relative permittivity, substrate height, strip width and pulse width of signal pulse when a design of MIC and MMIC is necessary.

  • PDF