• Title/Summary/Keyword: Pulse-on Time

Search Result 1,713, Processing Time 0.033 seconds

A hierarchical approach to state estimation of time-varying linear systems via block pulse function (블럭펄스함수를 이용한 시스템 상태추정의 계층별접근에 관한 연구)

  • 안두수;안비오;임윤식;이재춘
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.3
    • /
    • pp.399-406
    • /
    • 1996
  • This paper presents a method of hierarchical state estimation of the time-varying linear systems via Block-pulse function(BPF). When we estimate the state of the systems where noise is considered, it is very difficult to obtain the solutions because minimum error variance matrix having a form of matrix nonlinear differential equations is included in the filter gain calculation. Therefore, hierarchical approach is adapted to transpose matrix nonlinear differential equations to a sum of low order state space equation from and Block-pulse functions are used for solving each low order state space equation in the form of simple and recursive algebraic equation. We believe that presented methods are very attractive nd proper for state estimation of time-varying linear systems on account of its simplicity and computational convenience. (author). 13 refs., 10 figs.

  • PDF

Reducing PAPR for OFDM system by using Pulse-shping (OFDM 시스템에서 Pulse-shaping을 이용한 PAPR의 감소 방안)

  • 권혁일;양윤기
    • Proceedings of the IEEK Conference
    • /
    • 2002.06a
    • /
    • pp.263-266
    • /
    • 2002
  • Many methods have been Proposed to reduce the PAPR of the OFDM signal. Among them a method that uses the time waveform of the different sub-carriers. The method is referred to as pulse shaping and it works with arbitrary number of sub-carriers and my type of base-band linear modulation. It has been shown, using this technique, that it is possible to design a set of time waveforms that reduce the PAPR of the OFDM transmitted signal and improve its power spectrum simultaneously. In this paper, we investigate the effect of some of these sets of time waveforms on the OFDM system performance in terms of Bit Error Rate (BER).

  • PDF

Optical Transient Characteristics of Au-Compensated Silicon p-i-n Diode Switches (금이 보상된 실리콘 p-i-n 다이오드 스위치의 광 과도 특성)

  • Min, Nam-Ki;Henderson, H.T.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1205-1208
    • /
    • 1995
  • The optically-gated p-i-n diode switches have been fabricated with gold-compensated silicon. The turn-on and turn-off delay times and the rise and fall times were measured as a function of optical power level, bias, and pulse width. The turn-on characteristics shows a strong dependence an optical pulse power and a delay time(${\delta}{\iota}$) between two pulses, but a weak dependence on the width of optical pulse. Actually there is no turn-off delay in gold-doped p-i-n switches and the fall time is negligible.

  • PDF

Analysis of the Pulse Distortion on Tapered Microstrip Lines (테이퍼형 마이크로스트립 선로에서 펄스의 왜곡 특성 분석)

  • Kim, Gi-Rae
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.37 no.8
    • /
    • pp.45-51
    • /
    • 2000
  • The distortion of an electrical pulse, which has a rise/fall time due to the dispersion and the reflection, on tapered microstrip lines has investigated In time domain. The voltage and current transfer functions are shown for the tapered line. The dispersion distortion obtained by using these trans(or functions are represented for the nonideal square pulse along the triangular, Tchebycheff and exponential tapered lines, and analyzed the influence of the reflection and the frequency dispersion on the distorted voltage wave in the tapered lines. The observed overshoot in front of the distorted wane is caused due to the frequency dispersion and the sustained tail of that comes from the reflection in the tapered line.

  • PDF

The Effect of $Sa-Am$ Lung Sedating Acupuncture on Wrist Pulse in Healthy Human Subjects (폐승격(肺勝格) 자침이 촌관척(寸關尺) 맥파변화에 미치는 영향)

  • Kim, Seok-Joo;Lee, Hyun
    • Journal of Acupuncture Research
    • /
    • v.29 no.2
    • /
    • pp.43-57
    • /
    • 2012
  • Objectives : The purpose of this study is to observe the effects of $Sa-Am$ lung sedating acupuncture (LS) on wrist pulse changes in healthy participants. Method : Forty healthy subjects participated in this study, and were divided into an acupuncture group and controlled group. Using a three-dimensional pulse imaging system (DMP-3000), wrist pulse was measured before, immediately after, 30 minutes after and 60 minutes after acupuncture in the acupuncture group, with the rest in controlled group. Sixteen parameters between the acupuncture group and the controlled group were analyzed at Cun, Guan and Chi in each time. Result : After LS acupuncture, wrist pulse sixteen parameters were changed significantly according to the time at each measuring region. 1. Heart rate significantly decreased in immediately after, 30 minutes after and 60 minutes after, Pulse period significantly increased in 30 minutes after and 60 minutes after. 2. T4 didn't significantly changed, T-T4 significantly increased in immediately after, 30 minutes after and 60 minutes after. T4/T, T4/(T-T4), T1/T, T5/T significantly decreased in immediately after, 30 minutes after and 60 minutes after. (T-T4)/T significantly decreased in immediately after, 30 minutes after and 60 minutes after. T5 significantly increased in 30 minutes after and 60 minutes after. 3. Modulus of elasticity significantly decreased in left Cun 60 minutes after, significantly increased in left Chi 30 minutes after. 4. Variance of Amplitude significantly increased in right Guan 60 minutes after. 5. Area of pulse significantly increased in left Cun 60 minutes after, left Chi 30 minutes after and right Cun 60 minutes after. Systolic pulse area significantly decreased left Chi 30 minutes after, right Cun immediately after, 30 minutes after and 60 minutes after, right Guan in immediately after. 6. Energy/min significantly decreased in left Chi 60 minutes after and right Cun immediately after. EIx significantly decreased in right Cun immediately after. 7. In both sides Cun, Guan, Chi wrist pulse, a lot of significant changes in right Cun and left Chi appeared, and then followed by the left Cun, right Guan. Conclusion : This study analyzed that the correlation between LS acupuncture and radial pulse(cun, guan, chi) is considered to be meaningful, hereafter clinical studies on this are needed.

Clinical Study on the Sasang Constitutional Pulse Using Array Piezoresistive Sensor (어레이 압저항 센서를 활용한 체질맥 임상연구)

  • Lee, Si-Woo;Joo, Jong-Cheon;Kim, Kyung-Yo;Kim, Jong-Yeol
    • Journal of Sasang Constitutional Medicine
    • /
    • v.18 no.1
    • /
    • pp.118-131
    • /
    • 2006
  • 1. Objective Pulse diagnosis is generally applied to Traditional Oriental Medicine but not to Sasang Constitution diagnosis. Recently new pulse analyzer using array piezoresistive sensor and multi-channel robot arm developed. It reflects Oriental Medical Doctors' diagnostic processes, and its reproducibility test was done at Korea Institute of Oriental Medicine. We performed this study to set parameters diagnosing Sasang Constitution. 2. Methods One hundred thirty three subjects participated in this study. They are healty and approved this study. Before being tested with pulse analyzer, they had interview with Sasang Constitution Specialist to diagnose their Sasang Constitution. We established some useful parameters from parameters of pulse analyzer according to the Original Texts of Oriental Medicine and clinical experiences to analyze with clinical data of this study. 3. Results (I) There is a significant difference in pre-dicrotic notch time among all parameters of pulse analyzer in Sasang Constitution groups(P=0.047). (2) There is a significant difference in maximum pulse pressure in 33 to 48 year Sasang Constitution groups(P=0.010). (3) There is a significant difference in frequency width in 17 to 32 year Sasang Constitution groups(P=0.002). (4) There is a significant difference in CFS value in groups which OMD diagnoses; Floating & Sinking pulse(P=0.020). (5) There is a significant difference in pulse rate in groups which OMD diagnoses; Rapid & Slow pulse(P=0.000). (6) There is a significant difference in maximum pulse pressure in groups which OMD diagnoses; Deficient & Solid pulse(P=0.000). 4. Conclusions Analyzing parameters in each Sasang Constitution group, we found it shows significant difference in maximum pulse pressure and corresponding tendency in coefficient of floating & sinking pulse with theories of Sasang Consti-tutional Medicine. As we accumulate more clinical data, we will establish algorithm to diagnose Sasang Constitution using a pulse analyzer.

  • PDF

The study on the interrelationship of fixing the Ki-Gu(氣口) pulse and the Yin-Yeong(人迎) pulse in front of Kwan(關) the distance of 1 Pun(分) and the development of the Kwan-Pulse(關脈) (기구인영맥(氣口人迎脈)의 '관전일분처(關前一分處)' 비정(比定)과 관맥(關脈) 형성과정(形成過程)의 상관성(相關性)에 관한 연구(硏究))

  • Kim, Jeong-Giu
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.13 no.2
    • /
    • pp.14-23
    • /
    • 2009
  • In the Ki-Gu(氣口) pulse and the Yin-Yeong(人迎) pulse are the arterial pulsation position of the Lung Channel of Hand-Taeuem(手太陰) and the Stomach Channel of Foot-Yangmyeong(足陽明). At the pulses we can examine the circulation of Ki-Hyeol(氣血), the balance of Uem-Yang(陰陽), the deficiency and excess of the diseases, whether the disease is in Uem-Channel(陰經) or Yang-Channel (陽經), whether the disease is internel injury or externel injury. In the Ki-Gu(氣口) pulse and the Yin-Yeong(人迎) pulse are in front of the Right-Kwan(右關) and the Left-Kwan(左關) the distance of 1 Pun(分) because of completion of the Chon-Ku-Pulse-Taking(寸口脈診). The purpose of examnation is same to . In the Kwan-Pulse(關脈) doesn't have the position. It has only the role of a gateway of the circulation of Ki-Hyeol(氣血), the balance of Uem-Yang(陰陽). And it is same to role of the Ki-Gu(氣口) pulse and the Yin-Yeong(人迎) pulse in . So we can think that the Kwan-Pulse(關脈) in and the Ki-Gu(氣口) pulse and the Yin-Yeong(人迎) pulse in are the same thing. And we must have the different standard when examine the condition of Sam-Cho(三焦) and the circulation of Ki-Hyeol(氣血), the balance of Uem-Yang(陰陽) because the position of the Kwan-Pulse(關脈) came out after the time of .

  • PDF

Etch Characteristics of $SiO_2$ by using Pulse-Time Modulation in the Dual-Frequency Capacitive Coupled Plasma

  • Jeon, Min-Hwan;Gang, Se-Gu;Park, Jong-Yun;Yeom, Geun-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.472-472
    • /
    • 2011
  • The capacitive coupled plasma (CCP) has been extensively used in the semiconductor industry because it has not only good uniformity, but also low electron temperature. But CCP source has some problems, such as difficulty in varying the ion bombardment energy separately, low plasma density, and high processing pressure, etc. In this reason, dual frequency CCP has been investigated with a separate substrate biasing to control the plasma parameters and to obtain high etch rate with high etch selectivity. Especially, in this study, we studied on the etching of $SiO_2$ by using the pulse-time modulation in the dual-frequency CCP source composed of 60 MHz/ 2 MHz rf power. By using the combination of high /low rf powers, the differences in the gas dissociation, plasma density, and etch characteristics were investigated. Also, as the size of the semiconductor device is decreased to nano-scale, the etching of contact hole which has nano-scale higher aspect ratio is required. For the nano-scale contact hole etching by using continuous plasma, several etch problems such as bowing, sidewall taper, twist, mask faceting, erosion, distortions etc. occurs. To resolve these problems, etching in low process pressure, more sidewall passivation by using fluorocarbon-based plasma with high carbon ratio, low temperature processing, charge effect breaking, power modulation are needed. Therefore, in this study, to resolve these problems, we used the pulse-time modulated dual-frequency CCP system. Pulse plasma is generated by periodical turning the RF power On and Off state. We measured the etch rate, etch selectivity and etch profile by using a step profilometer and SEM. Also the X-ray photoelectron spectroscopic analysis on the surfaces etched by different duty ratio conditions correlate with the results above.

  • PDF

Experimental Investigation on Air Consumption and Pressure Wave Propagation inside A Filter Bag of A Dust Collector (집진기의 공기소모량과 백 필터내의 압력전파에 대한 실험적 연구)

  • Jeung, Won-Rark;Hong, Sung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.4
    • /
    • pp.886-891
    • /
    • 2008
  • This experimental investigation is concerned with the relationship between the electrical-on time of a solenoid which is located on the top of a pulse valve and air consumption of a dust collector. For the air consumption per pulse would be one of major factors affecting the operating cost of a dust collector, more attention is needed on the behaviour of a pulse valve. A pulse jet is blasted into a bag filter as the diaphragm valve opens and inflates a bag filter. This air-blast breaks up the dust layer and cleans the filter by dislodging dust cake. It is interpreted in this research that the cleaning filter is done by the impulse of a pulse jet. Hence, the magnitude and fluctuation of the dynamic pressure is measured using by a dynamic pressure sensor and the impulse is obtained by integrating dynamic pressure variation against time. Through this experimental work, conclusions are drawn implementing magnitude of averaged impulsive pressure per pulse or pressure impulse per unit volume of consumed air.

A Study on the Research Demands for the Pulse Analyzer (맥진기 연구개발에 대한 수요조사)

  • Kim, Gyeong-Cheol;Kim, Jong-Hwan;Shin, Woo-Jin;Lee, Hai-Woong;Kang, Hee-Jung
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.13 no.1
    • /
    • pp.29-40
    • /
    • 2009
  • The demand of research for the development of pulse meter and analyzer by the examination questionnaire made from repeated preliminary investigations. Which was presented in the exhibition KIMES 2008, it's has been proved to be practical. 159 people(oriental medical doctor) sent in the question papers and selected the double answers in the relevant question. At the time of the development of the pulse meter and analyzer, we put the investigation for oriental medical doctor's demands in practice and found the following results. The development of the pulse analyzer is getting more important for modernization of oriental medicine. The purpose of this study was to find out the research needs for the pulse analyzer considering the practical use in the oriental medical clinics. A survey was conducted at the KIMES 2008 exhibition with a set of questionnaires. We collected the data from 159 oriental medical doctors who attended the exhibition, and we found following results. The more oriental doctors did not think the diagnostic devices were important in their clinical practices. Most responders preferred to use the Chon-Kwan-Cheok pulse diagnosis. To find out the mechanism of the pulse diagnosis and to standardize it, the clinical data base containing the results of the pulse diagnosis and the patten discrimination of each patient should be established. In conclusion, the researches on the standardization of Chon-Kwan-Chuk pulse diagnosis including the measurement techniques and the pulse-pattern correlations are very important for developing the pulse analyzer.

  • PDF