• Title/Summary/Keyword: Pulse-on Time

Search Result 1,715, Processing Time 0.032 seconds

Effect of thermal laser pulse in transversely isotropic Magneto-thermoelastic solid due to Time-Harmonic sources

  • Lata, Parveen;Kaur, Iqbal;Singh, Kulvinder
    • Coupled systems mechanics
    • /
    • v.9 no.4
    • /
    • pp.343-358
    • /
    • 2020
  • The present research deals with the time-harmonic deformation in transversely isotropic magneto thermoelastic solid with two temperature (2T), rotation due to inclined load and laser pulse. Generalized theory of thermoelasticity has been formulated for this mathematical model. The entire thermo-elastic medium is rotating with uniform angular velocity and subjected to thermally insulated and isothermal boundaries. The inclined load is supposed to be a linear combination of a normal load and a tangential load. The Fourier transform techniques have been used to find the solution to the problem. The displacement components, stress components, and conductive temperature distribution with the horizontal distance are computed in the transformed domain and further calculated in the physical domain using numerical inversion techniques. The effect of angle of inclination of normal and tangential load for Green Lindsay Model and time-harmonic source for Lord Shulman model is depicted graphically on the resulting quantities.

Analytical solution of a two-dimensional thermoelastic problem subjected to laser pulse

  • Abbas, Ibrahim A.;Alzahrani, Faris S.
    • Steel and Composite Structures
    • /
    • v.21 no.4
    • /
    • pp.791-803
    • /
    • 2016
  • In this article, the problem of a two-dimensional thermoelastic half-space are studied using mathematical methods under the purview of the generalized thermoelastic theory with one relaxation time is studied. The surface of the half-space is taken to be thermally insulated and traction free. Accordingly, the variations of physical quantities due to by laser pulse given by the heat input. The nonhomogeneous governing equations have been written in the form of a vector-matrix differential equation, which is then solved by the eigenvalue approach. The analytical solutions are obtained for the temperature, the components of displacement and stresses. The resulting quantities are depicted graphically for different values of thermal relaxation time. The result provides a motivation to investigate the effect of the thermal relaxation time on the physical quantities.

Degradation of Composite Insulator as Accelated Aging Test (가속열화 실험에 의한 고분자 애자의 분해)

  • 이용희;장동욱;박영국;박정남;강성화;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.144-147
    • /
    • 2000
  • The effect of accelerated aging test on ethylene-propylene-diene monomer(EPDM) rubber used for outdoor insulation was studied by X-ray photoelectron spectroscopy(XPS), scanning electron microscope(SEM), FFT spectrum alalysis, and electrical pulse counts using PC by oscilloscope(300 MHz). In electrical alalysis, FFT spectrum analysis indicated arcing caused a significant increase in the third harmonic content of the leakage current of polluted insulator. Also, pulse counts increased as aging time. The surface oxygen and aluminum content were found to increase and that of carbon and nitrogen were found to decrease with time. The detailed XPS analysis indicated that the concentration of carbon in C-C decreased and concentration of highly oxidized carbons increased with time, which was due to the oxidation of EPDM rubber polymer SEM analysis indicated that crack and erosion of EPDM rubber occurred with time.

  • PDF

Time-dependent Analysis of Optical Receivers Using Receiver Eigenmodes

  • Seo, Kyung Hee;Lee, Jae Seung;Willner, Alan E.
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.4
    • /
    • pp.305-311
    • /
    • 2013
  • Using receiver eigenmodes, we perform a time-dependent analysis of optical receivers whose optical inputs are corrupted by the amplified spontaneous emission. We use Gaussian receivers for the analysis with Gaussian input pulses. We find the number of contributing eigenmodes increases as the measurement time moves from the pulse center towards the pulse edges at the output of the optical receiver's electrical filter. This behavior is dependent on the bandwidth ratio between the optical and the electrical filters as well as the input pulse's time width.

The Study on the Mutual Characteristics Between Transmitting Efficiency of Pulse Energy and Wall Plug Consumed Power of Non-Thermal Plasma (저온 플라즈마의 펄스에너지 전송효율과 Wall Plug 소비전력과의 상호 특성에 관한 연구)

  • Jeong, Jong-Han;Jeong, Hyeon-Ju;Kim, Hwi-Yeong;Jeong, Yong-Ho;Song, Geum-Yeong;Kim, Geun-Yong;Kim, Hui-Je
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.10
    • /
    • pp.506-510
    • /
    • 2002
  • In this paper, we study on the mutual characteristics between transmitting efficiency of pulse energy and wall plug consumed power of non-thermal Plasma for removing environmental pollutive gas of coal plant. To obtain high pulse energy of our system, we used MPC(magnetic pulse compressor) of power switch and tested their characteristics by adjusting electrode length of reactor and charging voltage in capacitor. As a result, we obtained consumed power of wall plug and a compressed pulse of voltage 110kV, rising time 500ns. Impedance of load on increasing electrode length was decreased, but electrical efficiency was increased. These results indicate we can control critical voltage of pulse corona and electrical efficiency of economic cost in power plant.

Enthalpy transport in pulse tube refrigerators (맥동관냉동기의 앤탈피이동)

  • 강영구;정은수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.2
    • /
    • pp.180-192
    • /
    • 1998
  • Enthalpy transport in a pulse tube was investigated by two-dimensional analysis of mass, momentum and energy equations assuming that the axial temperature gradient in the pulse tube is constant. Time-averaged second-order conservation equations of mass, momentum and energy were used to show the existence of steady mass streaming and enthalpy streaming. Effects of axial temperature gradient, velocity amplitude ratio and heat transfer between the gas and the wall on the steady mass streaming and enthalpy streaming were shown. Enthalpy loss due to the steady mass streaming is zero for basic and orifice pulse tube refrigerators, but it is proportional to the axial temperature gradient and steady mass flow rate through a pulse tube for double inlet pulse tube refrigerators.

  • PDF

Net Enthalpy Transport in Pulse Tube Refrigerators

  • Kang, Young-Goo;Jeong, Eun-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.7
    • /
    • pp.33-44
    • /
    • 1999
  • Enthalpy transport in a pulse tube was investigated by two-dimensional analysis of mass, momentum and energy equations assuming that the axial temperature gradient in the pulse tube was constant. The time-averaged second-order conservation equations of mass, momentum and energy were used to show the existence of steady mass and enthalpy streaming. Effects of the axial temperature gradient, velocity amplitude ratio, and heat transfer between the gas and the tube wall On the steady mass and enthalpy streaming were shown. Enthalpy loss due to the steady mass streaming is zero for basic and orifice pulse tube refrigerators, but it is proportional to the axial temperature gradient and steady mass flow rate through a pulse tube for double inlet pulse tube refrigerators.

  • PDF

Use of near-fault pulse-energy for estimating critical structural responses

  • Chang, Zhiwang;Liu, Zhanhui;Chen, Zhenhua;Zhai, Changhai
    • Earthquakes and Structures
    • /
    • v.16 no.4
    • /
    • pp.415-423
    • /
    • 2019
  • Near-fault ground motions can impose particularly high seismic demands on structures due to the pulses that are typically observed in the velocity time-histories. In this study it is empirically found that the critical response can be estimated from the directions corresponding to the maximum (max) or minimum (min) pulse-energy. Determination of the pulse-energy requires removing of the high-frequency content. For achieving this, the wavelet analysis and the least-square-fitting (LSF) algorithm are adopted. Results obtained by the two strategies are compared and differences between them are analyzed. Finally, the relationship between the critical response and the response derived from directions having the max or min pulse-energy confirms that using the pulse-energy for deriving the critical response of the building structures is reasonable.

A Comparative Study of Transistor and RC Pulse Generators for Micro-EDM of Tungsten Carbide

  • Jahan, Muhammad Pervej;Wong, Yoke San;Rahman, Mustafizur
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.9 no.4
    • /
    • pp.3-10
    • /
    • 2008
  • Micro-electrical discharge machining (micro-EDM) is an effective method for machining all types of conductive materials regardless of hardness. Since micro-EDM is an electro-thermal process, the energy supplied by the pulse generator is an important factor in determining the effectiveness of the process. In this study, an investigation was conducted on the micro-EDM of tungsten carbide (WC) to compare the performance of transistor and resistance/capacitance (RC) pulse generators in obtaining the best quality micro-hole. The performance was measured by the machining time, material removal rate, relative tool wear ratio, surface quality, and dimensional accuracy. The RC generator was more suited for minimizing the pulse energy, which is a requirement for fabricating micro-parts. The smaller-sized debris formed by the low-discharge energy of RC micro-EDM could be easily flushed away from the machined zone, resulting in a surface free of burrs and resolidified molten metal. The RC generator also required much less time to obtain the same quality micro-hole in WC. Therefore, RC generators are better suited for fabricating micro-structures, producing good surface quality and better dimensional accuracy than the transistor generators, despite their higher relative tool wear ratio.

Research on Subcutaneous Pulse Shape Measurement by Near-infrared Moiré Technique

  • Chen, Ying-Yun;Liu, Zhizhen;Du, Jian;Chang, Rong-Seng
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.2
    • /
    • pp.123-129
    • /
    • 2015
  • A pulse is generated when the heart pumps blood into the arterial system. The heart pumps blood only when it contracts, not when it relaxes; therefore, blood enters the arterial system in a cyclical form. Artery beating is visible in some parts of the body surface, such as the radial artery of the wrist. This paper mainly uses the feature in which near-infrared spectroscopy penetrates skin to construct a non-invasive measurement system that can measure small vibration in the subcutaneous tissue of the human body, and then uses it for the pulse measurement. This measurement system uses the optical moir$\acute{e}$ principle, together with the fringe displacement made by small vibration in the subcutaneous tissue, and an image analysis program to calculate the height variation from small vibrations in the subcutaneous tissue. It completes a measurement system that records height variation with time, and that together with a fast Fourier transform (FFT) program, they can convert the pulse waveform generated by vibration (time-amplitude) to heartbeat frequency (frequency-amplitude). This is a new and non-invasive medical assistance system for measuring the pulse of the human body, with the advantages of being simple, fast, safe and objective.