• Title/Summary/Keyword: Pulse width ratio

Search Result 167, Processing Time 0.02 seconds

Active optical coupler using the side polished single mode fiber and thermo-optic polymer multimode planar waveguide (측면 연마된 단일모드 광섬유와 열 광학 다중모드 평면도파로를 이용한 능동형 광 결합기)

  • 김광택;유호종;김성국;이소영;송재원;이상재;김시홍;강신원
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.3
    • /
    • pp.248-253
    • /
    • 1999
  • In this paper, we have investigated a fiber type active coupler which utilizes the mode coupling between the side polished single mode optical fiber and the active multimode planar waveguide. The proposed device can be used for not only tunable wavelength filter or optical intensity modulator but also a tool for measuring optical properties of guiding material such as refractive index, birefringence, electro-optic coefficient, and thermo-optic coefficient. We gave designed and optimized a coupler structure using the BPM and fabricated the device using thermo-optic polymer as active planar waveguide overlay. The device showed that insertion loss was less then 0.5 dB, extinction ratio was -13 dB at the resonance wavelength, and the wavelength tunablity due to thermo-optic effect was -1.5 nm/$^{\circ}C$. The active coupler using thermo-optic effect can be used as a wavelength tunable filer, an optical intensity modulator and an optical sensor. pulses that are subsequently compressed by a dispersive optical fiber. Experimental results show that $sech^2$ shape pulses with a pulse width of ~14 ps and a time bandwidth product of ~0.34 are successfully generated at 10 GHz repetition rate. In contrast to other methods, such as higher order soliton compression, this approach does not depend on the optical power and thus shows promise for application to low-power lasers.

  • PDF

A CMOS Band-Pass Delta Sigma Modulator and Power Amplifier for Class-S Amplifier Applications (S급 전력 증폭기 응용을 위한 CMOS 대역 통과델타 시그마 변조기 및 전력증폭기)

  • Lee, Yong-Hwan;Kim, Min-Woo;Kim, Chang-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.1
    • /
    • pp.9-15
    • /
    • 2015
  • A CMOS band-pass delta-sigma modulator(BPDSM) and cascode class-E power amplifier have been developed CMOS for Class-S power amplifier applications. The BPDSM is operating at 1-GHz sampling frequency, which converts a 250-MHz sinusoidal signal to a pulse-width modulated digital signal without the quantization noise. The BPDSM shows a 25-dB SQNR(Signal to Quantization Noise Ratio) and consumes a power of 24 mW at an 1.2-V supply voltage. The class-E power amplifier exhibits an 18.1 dBm of the maximum output power with a 25% drain efficiency at a 3.3-V supply voltage. The BPDSM and class-E PA were fabricated in the Dongbu's 110-nm CMOS process.

A Study for Color and Illuminance Control Algorithm of Broadcast LED Lighting (방송용 LED 조명의 광색과 조도 제어 알고리즘에 대한 연구)

  • Shin, Dong-Seok;Park, Chul-Hyung;Park, Chong-Yeun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.11
    • /
    • pp.6-17
    • /
    • 2015
  • In this paper, colors of broadcast lightings composed of Red, Green, and Blue LED(Light Emitted Diode) can be linearly and quantitatively controlled in low illuminance. Because LED cannot emit uniform illuminance in low illuminance, the colors of RGB LED are unmixable. Furthermore, the illuminances are nonlinear with the dimming values of the RGB LED due to the nonlinearity of the output illuminance with the current through the LED. This nonlinearity generated errors of the target colors and illuminances. The proposed algorithm set up the target colors, which is expressed by the color coordinates in CIE 1931 color space, and the target illuminances. Then the illuminances of RGB LED were calculated using color mixing theory. The calculated illuminances determined the dimming values of the RGB LED for transmission via DMX512 communication. After the broadcasting lighting received the dimming values of the RGB LED via DMX512 communication,.RGB LED can emit target color and illuminance, and be controlled by calculating the PWM(Pulse Width Modulation) duty ratio of the hybrid LED driver which be considered the nonlinearity for the illuminances of the LED. As a result, the proposed algorithm can linearly and quantitatively control the colors and illuminances in full range of illuminance. Then we verify experimentally that the errors of the emitted color coordination x, y and illuminance are 2.27%, 3.6% and 1.5%, respectively.

Effects of Frequency Type on Muscle Function of the Thigh during Electrical Muscle Stimulation (전기근육자극 시 주파수 차이가 대퇴 근육 기능에 미치는 영향)

  • Woen-Sik Chae;Jae-Hu Jung
    • Korean Journal of Applied Biomechanics
    • /
    • v.33 no.1
    • /
    • pp.17-24
    • /
    • 2023
  • Objective: The purpose of this study was to investigate the effects of different frequency on of knee extensors muscle function during electrical muscle stimulation (EMS). Method: In this research, 40 subjects who have no musculoskeletal disorder, and less than a year workout experience were recruited in order to analyze effects of EMS with different stimulus frequency. Forty subjects were randomly divided into four groups of ten subjects in each group. A EMS training program with different frequencies (without EMS [WE], EMS with frequency 30 Hz [E30], EMS with frequency 60 Hz [E60], EMS with frequency 90 Hz [E90]) was assigned to each group. Throughout eight weeks of training, test subjects were simultaneously carried out knee extension exercises such as squat, leg extension, and leg-press while using EMS with different frequency (20 min, pulse width 250 ㎲, on-off ratio 1:1). Isokinetic knee extension strength, muscle activity of the rectus femoris (RF), the vastus medialis (VM), and the vastus lateralis (VL), and the median frequency of the RF, the VM, and the VL were collected and compared between pre and post training in order to find effects of applying EMS with different frequencies. For each dependent variable, a one-way ANOVA was to determine whether there were significant differences among four different conditions (p<.05). When a significant difference was found, post hoc analyses were performed using the contrast procedure. Results: When compared to WE and E90, E30 causes significant increase in isokinetic knee extension strength. No significant differences were found in EMG values across different EMS conditions. However, the median frequency of the VM in E30 was significantly increased than the corresponding value for WE. Conclusion: The results of this study showed that EMS training with 30 Hz frequency had positive effect on knee extensor. Based of the findings of the present study, EMS training with lower frequency may help the performer to focus on developing strength in knee extensor muscles.

A Low Area and High Efficiency SMPS with a PWM Generator Based on a Pseudo Relaxation-Oscillating Technique (Pseudo Relaxation-Oscillating 기법의 PWM 발생기를 이용한 저면적, 고효율 SMPS)

  • Lim, Ji-Hoon;Wee, Jae-Kyung;Song, Inchae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.11
    • /
    • pp.70-77
    • /
    • 2013
  • We suggest a low area and high efficiency switched-mode power supply (SMPS) with a pulse width modulation (PWM) generator based on a pseudo relaxation-oscillating technique. In the proposed circuit, the PWM duty ratio is determined by the voltage slope control of an internal capacitor according to amount of charging current in a PWM generator. Compared to conventional SMPSs, the proposed control method consists of a simple structure without the filter circuits needed for an analog-controlled SMPS or the digital compensator used by a digitally-controlled SMPS. The proposed circuit is able to operate at switching frequency of 1MHz~10MHz, as this frequency can be controlled from the selection of one of the internal capacitors in a PWM generator. The maximum current of the core circuit is 2.7 mA, and the total current of the entire circuit including output buffer driver is 15 mA at 10 MHz switching frequency. The proposed SMPS has a simulated maximum ripple voltage of 7mV. In this paper, to verify the operation of the proposed circuit, we performed simulation using Dongbu Hitek BCD $0.35{\mu}m$ technology and measured the proposed circuit.

Design of a PWM DC-DC Boost Converter IC for Mobile Phone Flash (휴대전화 플래시를 위한 PWM 전류모드 DC-DC converter 설계)

  • Jung, Jin-Woo;Heo, Yun-Seok;Park, Yong-Su;Kim, Nam-Tae;Song, Han-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.6
    • /
    • pp.2747-2753
    • /
    • 2011
  • In this paper, a PWM current-mode DC-DC boost converter for mobile phone flash application has been proposed. The converter which is operated with 5 Mhz high switching frequency is capable of reducing mounting area of passive devices such as inductor and capacitor, consequently is suitable for compact mobile phones. This boost converter consists of a power stage and a control block. Circuit elements of the power stage are inductor, output capacitor, MOS transistors and feedback resistors. Meanwhile, the control block consists of pulse width modulator, error amplifier, oscillator etc. Proposed boost converter has been designed and verified in a $0.5\;{\mu}m$ 1-poly 2-metal CMOS process technology. Simulation results show that the output voltage is 4.26 V in 3.7 V input voltage, output current 100 mA which is larger than 25 ~ 50 mA in conventional 500 Khz driven converter when the duty ratio is 0.15.

Photosynthetic Characteristics of Porphyra yezoensis Ueda Measured in situ by Diving Pulse-Amplitude Modulated (PAM) Fluorometry on the Southwestern Coast of the Korean Peninsula (남서해역에서 양식되는 방사무늬김(Porphyra yezoensis Ueda)의 Diving-PAM에 의한 광합성 특성)

  • Kim, Jeong Bae;Lee, Won-Chan;Kim, Hyung Chul;Choi, Hee-Gu;Park, Jung-Im;Cho, Yoonsik;Park, Hwan Hee
    • Korean Journal of Environmental Biology
    • /
    • v.30 no.3
    • /
    • pp.210-218
    • /
    • 2012
  • The morphological characteristics, carbon and nitrogen concentrations, stable isotope values and photosynthetic rates of Porphyra yezoensis were studied at the main purple lavers production areas on southwestern coast of Korea. The morphological characteristics of leaf length, leaf width and weight of Porphyra blades were between 11.6~16.3 (average 13.8) cm, 4.6~6.3 (average 5.4) cm, $1.1{\sim}2.6(average\;1.86)g\;DW\;m^{-2}$, respectively. Photosynthetic pigment of Chl a concentration of Porphyra blades was between $2.18{\sim}17.77(average\;9.65)mg\;DW\;Chl\;a\;m^{-2}$. Carbon and nitrogen concentrations of Porphyra blades was between $201{\sim}317(average\;240)mg\;DW\;g^{-1}$, $39.8{\sim}50.0(average\;43.5)mg\;DW\;g^{-1}$ and C/N ratio 5.0~6.7 (average 5.5). The range of average ${\delta}^{13}C$ and ${\delta}^{15}N$ values of Porphyra blades was between - 25.6 to - 24.0 (average - 24.7)‰ for ${\delta}^{13}C$, and 1.3 to 4.1 (average 2.1)‰ for ${\delta}^{15}N$. Photosynthetic characteristics of seaweeds measured by pulse amplitude modulation (PAM) fluorometry was used as an indicator of photosynthetic activity. We use Diving-PAM fluorometry to examine photosynthetic rates of the seaweeds Porphyra yezoensis at each station. Maximum quantum yield of Porphyra blades was between 0.46~0.55 (average 0.52), the variance of the effective PS II maximum quantum yield of the station was broadly similar. Maximum relative electron transport rate (rETRmax) of Porphyra blades was between $4.71{\sim}5.84(average\;5.33){\mu}mol\;electrons\;m^{-2}\;s^{-1}$, the changes of maximum relative electron transport rate (rETRmax) of Porphyra yezoensis were similar to those of PS II maximum quantum yield. Photosynthetic efficiency (${\alpha}$) was between 0.027~0.045 (average 0.036). Minimum saturating irradiance ($E_k$) range was $139{\sim}180(average\;156){\mu}mol\;photons\;m^{-2}\;s^{-1}$. Minimum saturating irradiance ($E_k$) made a difference by station within the area on southwestern coast. Carbon and nitrogen concentrations and photosynthetic rates of Porphyra blades production areas on southwestern coast were broadly similar. The photosynthetic characteristics showed low photosynthetic rates because the low maximum quantum yields and low maximum relative electron transport rate.