• Title/Summary/Keyword: Pulse wave analysis

Search Result 243, Processing Time 0.023 seconds

A Study on Falling Pressure Surge of ABS Using High Frequency PWM Control (고주파수 PWM제어를 이용한 ABS의 맥동 저감에 관한 연구)

  • Lee, Yong-Joo;Kim, Byeong-Woo;Park, Ho
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.12 no.3
    • /
    • pp.38-44
    • /
    • 2003
  • The solenoid valve in ABS hydraulic modulator is a two directional on-off valve and is controlled by around 100Hz high speed pulse width modulation. When the valve is switched from open state to closed state, noise and vibration due to pressure surge phenomena in the hydraulic line and wheel cylinder are made. In this study, we identify Pressure surge phenomenon in the braking process of a ABS, and investigate the way to reduce the phenomenon. For the purpose of theoretical analysis on the pressure surge in the closed state hydraulic line, characteristic curve method based on wave equation was utilized. To reduce the surge, high frequency control of 20kHz was attempted. The result showed that the surge pressure of 50% was reduced compared to one observed in the low frequency control. Duty variation of high frequency can control current of solenoid valve and prevent sudden change of displacement.

A Study on the Real Features of Harmonic Obstacle (고조파 장해의 진상에 관한 연구)

  • 이해기
    • Journal of the Korean Society of Safety
    • /
    • v.13 no.4
    • /
    • pp.162-171
    • /
    • 1998
  • This paper presents the harmonics obstacle analysis and countermeasure of electrical consumption a place. Harmonics that can be cosidered as a environmental pollution of the power systems become the cause of the accidents and damages. The responsibility of eliminating the harmonics firstly lies on the generating side. But the original characteristics of the system sush as the harmonic transfer characteristics and the impedance of the system affect each other in the process of the generation and transmission of the harmonic. Therefore it is very difficult to specify clearly the harmonic controlling responsibility, because electric machinery generating harmonics are various in the industrial fields. The output of a inverter has a high harmonic content. There are several ways of minimizing the output harmonic content. One way is to use pulse width modulation techniques within inverter. An alternative method is to combine a number of square-wave inverters. In this research, we measure the harmonic of the countermeasure of electrical consumption a place. The paper present the problem of new harmonic elimination method of PWM inverter fed induction motor system using W-FT series. In the future, the proposed PWM pattern by W-FT series is effective not only to the induction motor but also to the electromagnetic machine such as voltage reglator, UPS.

  • PDF

Analysis of high-frequency resonant Inverter character using efficient ozonizer (고효율 오존생기용 고주파 공진형 인버터의 특성 해석)

  • Kim, Young-Hoon;Hwang, Young-Min;Noh, In-Bae;Kim, Young-Bin;Heo, Tae-Won;Woo, Jung-In
    • Proceedings of the KIEE Conference
    • /
    • 2002.11d
    • /
    • pp.246-248
    • /
    • 2002
  • This paper presents a high-frequency voltage source inverter for silent corona discharge ozonizer application, which is characterized by the power control based on pulse density modulation (PDM). The PDM inverter produces either a square -wave ac-voltage state or a zero-voltage state at its ac terminals to control the average output voltage under constant do voltage and operating frequency. This results in a wide range of power control in the silent corona discharge load with a strong nonlinear characteristics. And proposed addition circuit for maintain discharge on the center of the airgap. In this paper, schemed equivalent electric circuit of the discharge electrode for simulation. Finally, the effectiveness of this discharge tube character of silent corona ozonizer is investigated in the simulation results.

  • PDF

Analysis of Ultrasonic Resonance Signal for Detecting the Defect of Adhesive Interface in Exit Cone (확대부 내열재의 접착계면 결함 검출을 위한 초음파 공진 신호 분석)

  • Kim, Dong-Ryun;Kim, Jae-Hoon;Lim, Soo-Yong;Park, Sung-Han;Yeh, Byung-Hahn
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.230-237
    • /
    • 2012
  • The ultrasonic resonance method was applied to detect the disbond interface and empty layer between steel and FRP of the exit cone. The ultrasonic resonance method can easily detect the disbond interface and empty layer by amplifying the ultrasonic signal, but pulse echo method is difficult to distinguish adhesive interface from disbond interface or empty layer. The resonance frequency was predicted using the pressure reflection coefficient of 3-layered medium, and measured from ultrasonic signal of the test block using Fast Fourier Transform. The ultrasonic resonance proved that the predicted resonance frequency was in good agreement with the measured resonance frequency.

  • PDF

Impact test of a centrifugal pump used in nuclear power plant under aircraft crash scenario

  • Huang, Tao;Chen, Mengmeng;Li, Zhongcheng;Dong, Zhanfa;Zhang, Tiejian;Zhou, Zhiguang
    • Nuclear Engineering and Technology
    • /
    • v.53 no.6
    • /
    • pp.1858-1868
    • /
    • 2021
  • Resisting an accidental impact of large commercial aircrafts is an important aspect of advanced nuclear power plant (NPP) design. Especially after the 9·11 event, some regulations were enacted, which required the design of NPPs should consider the accidental impact of large commercial aircrafts. Normal working of equipment is important for stopping reactor under an impact when an NPP is in operation. However, there is a lack of reliable analysis and research on the impact test of nuclear prototype equipment. Therefore, in order to study the response of the equipment under high acceleration impact, a centrifugal pump is selected as the research object to perform the impact test. A horizontal half-sinusoidal pulse wave was applied to the working pump. The test results show that the horizontal response of the motor and flange is greater compared to other parts, as well as the vertical response of the coupling. The stress response of the pump body support and motor support is high, hence these parts should be considered in the design of the pump. Finally, combined with the damage and stress evaluation results of the pump under different amplitudes, the ultimate impact acceleration that the pump can withstand is given.

Effect of College Students' Perceived Stress, Cognitive Response to Stress, and Somatization on Heart Rate Variability (대학생의 지각된 스트레스, 인지적 스트레스, 신체화가 심박변이도에 미치는 영향)

  • Park, Keum Suk;Yoon, Hea Min
    • Journal of Korean Biological Nursing Science
    • /
    • v.21 no.3
    • /
    • pp.178-187
    • /
    • 2019
  • Purpose: The purpose of this study was to investigate how college students' perceived stress, cognitive stress, and somatization affect their heart rate variability (HRV). Methods: This study is a cross-sectional survey research on 191 university students, registered at the G University. The perceived stress scale (PSS) and cognitive stress response scale, were used to assess level of stress. The somatization symptom scale of the Symptom Check List 90 (SCL-90), was used to assess level of somatization caused by stress. To assess heart rate variability (HRV), we conducted a five-minute test using a pulse wave analyzer, to analyze short-term HRV. Results: The SCL-90 somatization score had relatively high positive correlation (p< .001) with cognitive stress, but low positive correlation (p< .001) with perceived stress. Cognitive stress response had low negative correlation (p< .001) with 1nSDNN and 1nRMSSD among HRV parameters. Perceived stress was not correlated with HRV. Multiple regression analysis showed that variables of perceived stress, cognitive stress, and somatization symptoms, could not explain HRV. By contrast, one of the HRV indicators, 1nSDNN, was affected by age, gender, and aggressive-hostile thought, the latter being a subscale of the cognitive stress response scale. Conclusion: This study suggests that stress evaluation for people in early adulthood will be more effective, if the evaluation examines cognitive stress and heart rate variability.

Physical Recovery through Health Management Education for the Disabled or the Elderly

  • SON, Byung-Kook;CHOI, Eun-Mee;KWON, Lee-Seung
    • Journal of Wellbeing Management and Applied Psychology
    • /
    • v.4 no.1
    • /
    • pp.27-34
    • /
    • 2021
  • Purpose: The number of people with disabilities and the elderly over 65 years of age is gradually increasing due to physical disabilities and social aging. Their typical physical disorders or chronic diseases include low back pain, sciatic pain, arthritis, and musculoskeletal systems such as discs. The average prevalence of disease is 78%. These are various physical obstacles and hindrances in daily life. Research design, data and methodology: From August 6, 2019 to September 24, 2019, the Senior Welfare Center in Gyeyang-gu, Incheon, operated a healthy body exercise and health education program for living health management. Results: The vascular health index using U-Bio pulse wave was relatively good at the first average of +7.4, but the second average of -6.3. This can be seen as a result of the combination of diet and lifestyle education along with the effect of corrective exercise. As a result of body shape measurement analysis, the number of persons requiring management with 3 or more body imbalances was found to be from 75% before to 62.5% afterwards. Conclusions: Exercise effect appears when exercise lasts for at least 10 weeks. Some performances were good, but there were limitations due to the operation of a short training period.

Bayesian in-situ parameter estimation of metallic plates using piezoelectric transducers

  • Asadi, Sina;Shamshirsaz, Mahnaz;Vaghasloo, Younes A.
    • Smart Structures and Systems
    • /
    • v.26 no.6
    • /
    • pp.735-751
    • /
    • 2020
  • Identification of structure parameters is crucial in Structural Health Monitoring (SHM) context for activities such as model validation, damage assessment and signal processing of structure response. In this paper, guided waves generated by piezoelectric transducers are used for in-situ and non-destructive structural parameter estimation based on Bayesian approach. As Bayesian approach needs iterative process, which is computationally expensive, this paper proposes a method in which an analytical model is selected and developed in order to decrease computational time and complexity of modeling. An experimental set-up is implemented to estimate three target elastic and geometrical parameters: Young's modulus, Poisson ratio and thickness of aluminum and steel plates. Experimental and simulated data are combined in a Bayesian framework for parameter identification. A significant accuracy is achieved regarding estimation of target parameters with maximum error of 8, 11 and 17 percent respectively. Moreover, the limitation of analytical model concerning boundary reflections is addressed and managed experimentally. Pulse excitation is selected as it can excite the structure in a wide frequency range contrary to conventional tone burst excitation. The results show that the proposed non-destructive method can be used in service for estimation of material and geometrical properties of structure in industrial applications.

Association between fish and shellfish, and omega-3 PUFAs intake and CVD risk factors in middle-aged female patients with type 2 diabetes

  • Kim, Hyesook;Park, Seokyung;Yang, Hyesu;Choi, Young Ju;Huh, Kap Bum;Chang, Namsoo
    • Nutrition Research and Practice
    • /
    • v.9 no.5
    • /
    • pp.496-502
    • /
    • 2015
  • BACKGROUND/OBJECTIVES: This study was performed to investigate the association between the dietary intake of fish and shellfish, and omega-3 polyunsaturated fatty acids (PUFAs) and cardiovascular disease (CVD) risk factors in the middle-aged Korean female patients with Type 2 diabetes (T2D). SUBJECTS/METHODS: A cross-sectional analysis was performed with 356 female patients (means age: 55.5 years), who were recruited from the Huh's Diabetes Clinic in Seoul, Korea between 2005 and 2011. The dietary intake was assessed by a validated semi-quantitative food frequency questionnaire and analyzed using the Computer Aided Nutritional Analysis program (CAN-Pro) version 4.0 software. RESULTS: In a multiple regression analysis after the adjustment for confounding factors such as age, BMI, duration of diagnosed T2D, alcohol consumption, fiber intake, sodium intake, and total energy intake, fish and shellfish intake of the subjects was negatively associated with triglyceride and pulse wave velocity (PWV). Omega-3 PUFAs intake was negatively associated with triglyceride, systolic blood pressures, diastolic blood pressures, and PWV. The multiple logistic regression analysis with the covariates showed a significant inverse relationship between the omega-3 PUFAs consumption and prevalence of hypertriglyceridemia [OR (95% CI) for greater than the median compared to less than the median: 0.395 (0.207-0.753)]. CONCLUSIONS: These results suggest that the consumption of fish and shellfish, good sources of omega-3 PUFAs, may reduce the risk factors for CVD in the middle-aged female patients with T2D.

Analysis of Change Rate of SBP and DBP Estimation Fusion Algorithm According to PTT Measurement change PPG Pulse Wave Analysis (PPG 맥파 분석의 PTT 측정변화에 따른 SBP, DBP 추정 융합 알고리즘 변화율 분석)

  • Kim, Seon-Chil
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.7
    • /
    • pp.35-40
    • /
    • 2020
  • Recently, devices such as smart watches capable of measuring small biosignals have been released. Body composition, blood pressure, heart rate, and oxygen saturation can be easily obtained. However, the part that is not trusted by the user is accuracy. These biosignals are sensitive to the external environment and have large fluctuations depending on the conditions inside the subject's body. Blood pressure measurements, in particular, still give different results, depending on how the conditions in the body are handled. Therefore, in this study, PPG was analyzed to measure PTT at two points of 80% and 100%, the highest in PTT measurement. The effect of the measured value on SBP and DBP was analyzed and a method was proposed to increase the accuracy. As a result of the study, the measured value of PTT at 80% of the peak PPG is more effective in estimating blood pressure of SBP and DBP than the value measured at 100%. In the regression analysis of the rate of change blood pressure estimation, the coefficient of determination of SBP (80%) was 0.6946, and DBP (100%) was 0.547.