• Title/Summary/Keyword: Pulse wave analysis

Search Result 243, Processing Time 0.027 seconds

Numerical modelling and finite element analysis of stress wave propagation for ultrasonic pulse velocity testing of concrete

  • Yaman, Ismail Ozgur;Akbay, Zekai;Aktan, Haluk
    • Computers and Concrete
    • /
    • v.3 no.6
    • /
    • pp.423-437
    • /
    • 2006
  • Stress wave propagation through concrete is simulated by finite element analysis. The concrete medium is modeled as a homogeneous material with smeared properties to investigate and establish the suitable finite element analysis method (explicit versus implicit) and analysis parameters (element size, and solution time increment) also suitable for rigorous investigation. In the next step, finite element analysis model of the medium is developed using a digital image processing technique, which distinguishes the mortar and aggregate phases of concrete. The mortar and aggregate phase topologies are, then, directly mapped to the finite element mesh to form a heterogeneous concrete model. The heterogeneous concrete model is then used to simulate wave propagation. The veracity of the model is demonstrated by evaluating the intrinsic parameters of nondestructive ultrasonic pulse velocity testing of concrete. Quantitative relationships between aggregate size and testing frequency for nondestructive testing are presented.

The Classification and Frequency Analysis in Radial Pulse (맥파의 인식상의 분류와 주파수 해석)

  • Kil, S.K.;Han, S.H.;Kwon, O.S.;Park, S.H.;Hong, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.263-264
    • /
    • 1998
  • In this paper, we present the result of feature points recognition and classification of radial pulse by the shape of pulse wave. And we analyze radial pulse in frequency domain. The recognition algorithm use the method which runs in parallel with both the data of ECG and differential pulse simultaneously to recognize the feature points. Also fie specified 3-time elements of pulse wave as main parameters for diagnosis and measured them by execution of algorithm, then we classify the shape of radial pulse by existence and position of feature points. lastly we execute frequency analysis on the feature points and get the power spectrum of radial pulse.

  • PDF

The oriental medical study about the arrythmia detected on the radial pulses and the result of ECG (촌관척(寸關尺)부의 검측한 부정맥과 electrocardiographic 결과와의 한의학적 검토)

  • Lyu, Heui-Yeong;Heo, Eun-Jung;Kim, Ji-Hyon;Yun, Jung-Mi;Jeon, Seong-Ha
    • Journal of the Korean Institute of Oriental Medical Informatics
    • /
    • v.14 no.1
    • /
    • pp.81-106
    • /
    • 2008
  • The ECG which used for this paper, is analysis result from alogrisms of arrythmia, and we have studied that how we could certain Cold(寒 )type or Heat(熱) type and that Deficiency(虛) type or Excess(實)type of organs from various special diseases, and we obtained like these results. 1. we depend on our examination about Pulse(脈) because we can't discriminate arrythmia using EKG analysis instruments. 2. We obtained that Cold(寒) type diseases had wave that prolonged above normal baseline and ST wave which had downward aptitude. 3. We obtained that Heat(熱) type diseases had the fibrillation which had shortend wave that compare to normal and had downward aptitude or negative aptitude. 4. We obtained that Respiratory system (肺) diseases had wave that is within normal or is short of normal range and had much fluctuation in potential difference or trans on P wave. 5. The character of EKG which presented about diseases of gastric systems is prolonged above narmal range of wave, and the EKG had represented mixed wave with Heat(熱) type when accompany inflammatory in gastric system. 6. The wave of Blood Stasis(瘀血) type had upward aptitude of QRS wave, and the wave of anemia or blood loss type(少血 ) had downward aptitude of QRS wave, the wave which had both Cold(寒) and Heat (熱) represented mixed waves. 7. The Knotted Pulse(結脈) and Intermittent Pulse(代脈) is corresponded with sinus brady cardia, and the Swift Pulsle(疾脈) is corresponded with fibrillation. 8. We pay attention to the relations of formations about pressures pulse from formations of EMD( electromechanical dissociation ). From these results, we will have to study about EKG which using in tests of change of Parkinsons disease.

  • PDF

A Study on the Significant Point Detection Algorithm and Design of Hardware for Pulse Automatic Diagnosis (맥파자동진단을 위한 하드웨어의 설계 및 특성점 검출 알고리즘에 관한 연구)

  • Lee, J.Y.;Lee, J.W.;Lee, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2255-2258
    • /
    • 1998
  • Method of diagnosis in oriental medicine, the unbalance of the physiological function of the five viscers and six bowels of the human body is determined from time immemorial with the condition of blood circulation which is performed through blood vessels by the vitality of the heart. In oriental medicine, treatment is largely attempted by adjusting this unbalance. The analysis of pulse wave, which mainly measures the changes in blood flows, is to evaluate the shapes of a pulse wave rather than the quantitative changes like rates and strength of the pulse. This paper presents the development of Hardware System and Pulse Diagnosis Algorithm for automatic diagnosis of the pulse wave. This system makes the precise diagnosis and the objective recording possible.

  • PDF

Development of an Measuring System for Pulse Wave Corresponding to Different Radial Artery Diameters Caused by Indentation (요골동맥 직경 변화에 따른 맥파 측정 시스템 개발)

  • Lee, Jeon;Woo, Young-Jae;Jeon, Young-Ju;Lee, Yu-Jung;Kim, Jong-Yeol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2351-2357
    • /
    • 2008
  • Noninvasive radial artery pulse wave has been widely used not only for the pulse wave analysis(PWA) itself but also for assessment of arterial stiffness with estimated aortic pulse wave from peripheral pulse wave. However, it has been found that the deformation of pulse shape can be caused readily by changing measuring position, indentation pressure, and so on. So, in this study, we have developed a system which can measure radial pulse wave and skin displacement simultaneously while the indentation body goes down to occlude subject's radial artery. This system can be divided into a measuring apparatus part, an indentation control hardware part, a data acquisition part and a control and computation part. And, the measuring apparatus consists of an arm-rest, a step motor, an indentation body, a laser displacement sensor(LK-G30, Keyence Co.) and pulse wave sensor. Under load-free condition and radial artery loaded condition, the evaluation of developed system has been performed. From these results, we can conclude: 1) The developed system can control the indentation body quantitatively and the adopted laser displacement sensor shows linear output characteristic even with skin as a reflector. 2) This system can measure the pulse wave and the displacement of indentation body, that is, skin displacement simultaneously at each specific level of indentation body. 3) This system can provide the number of motor steps used to get down the indentation body, the measured skin displacement, the calculated indentation pressure, the calculated pulse pressure and the pulse waveform as well as the information generated by combining these with each others. 4) This system can reveal the relationship between the morphological changes of pulse wave and the estimated displacement of radial artery wall by indentation. Consequently, the developed system can furnish more abundant information on radial artery than previous diagnosis systems based on tonometric measurement. In further study, we expect to setup the standard measuring process and to concrete the algorithm for the estimation of radial artery's diameter and of displacement of radial artery's wall. Furthermore, with well designed clinical studies, we hope to turn out the usefulness of developed system in the field of cardiovascular system evaluation.

The Correlation of Pulse Wave Velocity and Atherosclerotic Risk Factor in Stroke Patients

  • Jin, Bok Hee;Han, Min Ho
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.47 no.1
    • /
    • pp.28-34
    • /
    • 2015
  • Pulse wave velocity (PWV) is used to non-invasively estimate the severity of arteriosclerosis by measuring arterial stiffness. Increased arterial stiffness measured by PWV stands for progressive arteriosclerosis and is caused by atherosclerotic risk factors. This study is focused on how brachial-ankle pulse wave velocity (baPWV) is related to the leading risk factors for arteriosclerosis or atherosclerosis. Subjects were 114, 69 males and 45 females who are in 60's and had baPWV test for acute stroke. The results are as follows: the group with increased arterial stiffness showed significant increase in HbA1c, total cholesterol, BSBP (brachial artery systolic blood pressure), BDBP (brachial artery diastolic blood pressure), CSBP (central artery systolic blood pressure), CDBP (central artery diastolic blood pressure), augmentation index (AIx) and diabetes mellitus. Correlation analysis between baPWV and atherosclerotic risk factor showed significant relationship in age, HbA1c, LDL cholesterol, BSBP, BDBP, CSBP, CDBP and augmentation index. baPWV was independently related to age and BSBP in multiple linear regression analysis. The group with increased arterial stiffness was independently related to BDBP in multiple logistic regression analysis. This study might be meaningful in evaluating the relationship between arterial stiffness and atherosclerotic risk factor in a new way, and be helped to make various studies for cardiovascular disease.

The Correlation analysis of Hydrotherapy and pulse wave velocity in patients with sequelae of CVA (중풍후유증 환자에 있어서 맥파전달속도와 초음파 족욕에 따른 상관관계에 관한 임상적 연구)

  • Yun, Dae-Chul;Kim, Hee-Taek;Ryu, Ju-Hyun;Choi, Jong-Min
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.19 no.1
    • /
    • pp.135-144
    • /
    • 2006
  • Objective : The purpose of this study was to know the clinical effects of hydrotherapy based Ultrasonic spa using SoPung-Tang on pulse wave velocity in patients with sequelae of CVA. Methods : PWV(Pulse wave velocity), Bio Chemistry, Hematology, Blood Pressure were investigated in 20 patients(Experimental group 13, Control group 7) who have been in Semyung Oriental medicine hospital from December 2005 to February 2006. Results : 1. In experimental group, Rt PWV diminished 4.8%, Lt PWV 5.1%. 2. In control group, Rt PWV diminished 3.3%, Lt PWV 1.8%. Conclusion : Hydrotherapy based Ultrasonic spa using SoPung-Tang showed useful effects in patients with sequelae of CVA.

  • PDF

Development of 3-channel Pulse Wave Measurement System (3채널 맥파 측정 시스템 개발)

  • Kim, Eun-Geun;Heo, Hyun;Nam, Ki-Chang;Kang, Hee-Jung;Huh, Young
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1049-1050
    • /
    • 2008
  • It is difficult to measure the pulse wave in a short time because radial artery position and located depth are different depending on the person. In this paper, the pulse wave measurement system was developed using 3 channel piezoresistive sensor array to detect the most significant pulse wave. Augmentation Index(AI) and Heart Rate(HR) analysis are also available for predicting cardiovascular risks. The developed system is small and easy to use. And it is promising to be used as home healthcare device.

  • PDF

Numerical Simulation of Borehole Expansion By Pulse Discharge (펄스 방전에 의한 시추공 확공 현상에 대한 수치해석)

  • Park, Hyun-Ku;Lee, Seung-Rae;Kim, Tae-Hoon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.1346-1353
    • /
    • 2009
  • In this study, a numerical study was carried out to simulate the expansion of ground borehole by pulse discharge technology using finite element analysis. Considering the mortar in the borehole as an acoustic medium and the surrounding soil as an elasto-plastic material, the strong shock wave developed by the pulse discharge was modeled using the underwater explosion model. The ground expansion was simulated based on a coupled acoustic-structural analysis with varying properties of mortar and soil, and the behavior between acoustic-structural interface.

  • PDF

Study on the Radial Pulse Wave Variables and Heart Rate Variability after Acupuncture Stimulation (침자극이 좌관맥상과 심박수 미세변화에 미치는 영향)

  • Won, Jae-Kyun;Jung, Soon-Kwan;Kim, Dong-Eun;Lim, Jin-Young;Kwon, Young-Dal;Yeom, Seung-Ryong;Lee, Su-Kyung;Song, Yung-Sun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.1
    • /
    • pp.237-244
    • /
    • 2009
  • We investigated the effects of acupuncture stimulation on pulse wave variables and heart rate variability (HRV) in healthy adults. To evaluate twenty healthy volunteers (10 men, 10 women) had acupuncture into both Hapkok (Ll4) and Taechung (Liv3) for 15 minutes. Radial pulse, Heart Rate Variability, body temperature and blood pressure were checked before and after acupuncture to evaluate Pulse Wave Variability and Autonomous Function. The results were as follows; Heart rate was significantly increased while systolic blood pressure (mmHg) and diastolic blood pressure (mmHg) were significantly increased after acupuncture treatment. Sixteen subjects didn't change representative pulse wave variables after acupuncture treatment. Energy, height of main peak (H1), height of pre-dicrotic valley (H2) and height of descending valley (H4) were decreased while height of dicrotic peak (H5) was significantly decreased after acupuncture treatment. Time to main peak (T1), time to pre-dicrotic valley (T2), time to dicrotic peak (T5), total time (T) and T-T4 were decreased while time to descending valley (T4) was increased after acupuncture treatment. Total area (At), area of main peak (Aw) and ratio of diastolic period area (Ad) were decreased while ratio of systolic period area (As) and angle of main peak (MPA) were increased after acupuncture treatment. The standard deviation of all normal RR intervals (SDNN) was increased while the root mean square of successive differences between the normal heart beats (RMSSD) was significantly increased after acupuncture treatment by time domain analysis. Low frequency power (LF) and LF/HF ratio were decreased while high frequency power (HF) was significantly increased after acupuncture treatment by frequency domain analysis. This study suggests that acupuncture treatment changes pulse wave variability and heart rate variability. Further study on various acupuncture treatment for pulse wave variability and heart rate variability is required.