• Title/Summary/Keyword: Pulse wave analysis

Search Result 244, Processing Time 0.024 seconds

Finite Element Analysis of Pressure Distribution by Ultrasound in Human Thigh Model (대퇴부 모델에서의 초음파 압력분포에 관한 유한요소 해석)

  • Choi, Ho-Seon
    • The Journal of Information Technology
    • /
    • v.8 no.1
    • /
    • pp.43-50
    • /
    • 2005
  • Quantitative analysis for distribution of penetrating ultrasound in vivo is very important to determine the treatment region and method. In this paper, we constructed a simplified 2-D femoral region model that consists of skin-fat-muscle-bone layered system, and simulated the pressure distribution in the model in case of applying ultrasound using Finite Element Method(FEM). The ultrasound used in the simulation was assumed to be pulse wave and the pressure distribution was analyzed during only one period of pulse wave. In order to find the penetration depth, amplitude of pressure and sphere that ultrasound reaches in the model, we performed the simulation with varying the applied frequency, transducer size and amplitude of transducer's output. The result showed that applied frequency is inversely proportional to the penetration depth and amplitude of pressure but the amplitude of transducer's output is proportional to the amplitude of pressure in the model. Also, the sphere that ultrasound reaches was widened and the amplitude of pressure became larger as the transducer size became larger. This results were similar to that obtained from the previous model consisting of fat-muscle-bone layered system, but we observed that the pressure of ultrasound is decreased due to the decrements of pressure by the absorption coefficient of skin and the interference that depends on the reflection of ultrasound caused by the difference of acoustic impedance of skin and fat. Finally, we can infer that the model proposed in this study is closer to the realistic model than the previous ones. It shows that the results obtained from this study can be useful in designing the ultrasound treatment instrument or in setting up the treatment plan.

  • PDF

Elevation of heart-femoral pulse wave velocity by short-term low sodium diet followed by high sodium diet in hypertensive patients with sodium sensitivity

  • Rhee, Moo-Yong;Kim, Ji-Hyun;Na, Sang-Hoon;Chung, Jin-Wook;Bae, Jun-Ho;Nah, Deuk-Young;Gu, Namyi;Kim, Hae-Young
    • Nutrition Research and Practice
    • /
    • v.10 no.3
    • /
    • pp.288-293
    • /
    • 2016
  • BACKGROUND/OBJECTIVES: We compared changes in heart-femoral pulse wave velocity (hfPWV) in response to low sodium and high sodium diet between individuals with sodium sensitivity (SS) and resistance (SR) to evaluate the influence of sodium intake on arterial stiffness. SUBJECTS/METHODS: Thirty-one hypertensive and 70 normotensive individuals were given 7 days of low sodium dietary approach to stop hypertension (DASH) diet (LSD, 100 mmol NaCl/day) followed by 7 days of high sodium DASH diet (HSD, 300 mmol NaCl/day) during 2 weeks of hospitalization. The hfPWV was measured and compared after the LSD and HSD. RESULTS: The hfPWV was significantly elevated from LSD to HSD in individuals with SS (P = 0.001) independently of changes in mean arterial pressure (P = 0.037). Conversely, there was no significant elevation of hfPWV from LSD to HSD in individuals with SR. The percent change in hfPWV from the LSD to the HSD in individuals with SS was higher than that in individuals with SR. Subgroup analysis revealed that individuals with both SS and hypertension showed significant elevation of hfPWV from LSD to HSD upon adjusted analysis using changes of the means arterial pressure (P = 0.040). However, there was no significant elevation of hfPWV in individuals with SS and normotension. CONCLUSION: High sodium intake elevated hfPWV in hypertensive individuals with SS, suggesting that high sodium intake increases aortic stiffness, and may contribute to enhanced cardiovascular risk in hypertensive individuals with SS.

Analysis of Shielded Twisted Pair Cable to External Field Coupling by Expanded Chain Matrix Modeling

  • Cho, Yong-Sun;Jung, Hyun-Kyo;Cheon, Changyul;Chung, Young-Seek
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.2049-2057
    • /
    • 2014
  • In this paper, a numerical method for analyzing coupling between high-altitude electromagnetic pulse (HEMP) as external field and a shielded twisted pair (STP) cable is proposed, which is based on an expanded chain matrix. Load responses of electromagnetic (EM) field excitation in uniform transmission line (TL) are solved by Baum-Liu-Tesche (BLT) equations in frequency domain, however, it is difficult to apply BLT equations to solve load responses of STP cable because the iteratively changing configuration of each twisted pairs are involved in cable. To avoid this problem and decrease memory and CPU time, we proposed the expanded chain matrix modeling method that is calculated using ABCD parameters, and applied multi-conductor transmission line (MTL) theory to consider the EMP coupling effectiveness of each twisted pairs. The results implemented by the proposed method are presented and compared with those obtained by the finite-difference time domain (FDTD) method as a kind of 3D full wave analysis.

PSD Analysis of HRV Using the Kaiser Window (Kaiser Window를 이용한 HRV의 PSD분석)

  • Choi, K.S.;Kim, D.C.;Lee, J.Y.;Kim, J.H.;Jeong, K.S.;Lee, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.3233-3235
    • /
    • 2000
  • A new method for HRV(heart rate variability} detection from the R-wave signal, based on the IPFM (integral pulse frequency modulation) model and its similarity to pulse position modulation, is presented. The proposed method exert lowpass filtering with a Kaiser window. In this paper, The proposed method presents a powerful, but simple, tool for investigation of HRV. It also guarantees real-time behavior, simplicity in design, and phase linearity. Even without the basic assumption of IPFM model, the new algorithm can still be used on-line and with higher performance. It is thoroughly proved that lowpass filtering is an ideal method for PSD (Power Spectrum Density) analysis of HRV.

  • PDF

Analysis of Ultrasonic Scattering from Side-drilled Holes (원주형 기공에 대한 초음파 산란 해석)

  • Jeong, Hyun-Jo;Park, Moon-Cheol
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.6
    • /
    • pp.559-565
    • /
    • 2004
  • Two different methods were used for the scattering analysis of side-drilled holes(SDH). The scattering models include an explicit model based on the Kirchhoff approximation and the solution of the exact separation of variables. The far-field scattering amplitude was calculated and their time-domain results were compared for the case of shear vertical wave. The exact solution predicts the existence of the creeping wave. The Kirchhoff approximation agreed to the exact solution, except the case of the creeping wave. Two measurement models were introduced to predict the response from the SDHs for the case of immersion, pulse-echo testing. The received voltage was calculated for the case of the shear vertical waves with the incident angle of $45^{\circ}$ to the SDH with the diameter of 1mm, and compared with the experimental results.

Nondestructive Evaluation of Creep Damage Materials by using Ultrasonic Spectrum Analysis (초음파 Spectrum 해석에 의한 Creep 손상재의 비파괴평가)

  • Kim, C.I.;Yi, W.;Lim, Y.H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.11 no.2
    • /
    • pp.42-47
    • /
    • 1991
  • Nondestructive evaluation study was made on creep damage materials by ultrasonic spectrum analysis. The evaluation methods was developed in order to predict the change of ultrasonic attenuation with increasing creep damage. A new algorithm for the improvement of measuring accuracy of ultrasonic attenuation using a spectrum analysis has been developed. Normally, the ultrasonic attenuation is evaluated from 1st and 2nd peak values of the pulse-echo ultrasonic wave. The algorithm developed is incorporated in a measuring system which consists of a personal computer with ultrasonic apparatus and a digital storage oscilloscope. By the spectrum analysis method, it become popssible to describe approximately the attenuation change with increassing creep damage in Cr-Mo-V forging.

  • PDF

A Study on the Correlation of Atherosclerosis Risk Factor and Pulse Wave Velocity(PWV) of Carotid-Femoral Artery With Sasang Constitution (맥파전도속도(PWV)를 이용한 체질별 죽상동맥경화 위험인자에 대한 상관관계 연구)

  • Im, Eun-Young;Lee, Je-Won;Chang, Woo-Seok;Baek, Kyung-Min;Cheon, Woo-Hyun;Chung, In-Kwon
    • The Journal of Internal Korean Medicine
    • /
    • v.31 no.3
    • /
    • pp.467-476
    • /
    • 2010
  • Object : The purpose of this study was to investigate the correlation of atherosclerosis risk factors and pulse wave velocity (PWV) of carotid-femoral artery with Sasang constitution. This study also aimed to investigate the relationship between PWV and risk factors of atherosclerosis, including serum cholesterol and homosisteine, hs-CRP. Methods : We enrolled 160 patients without experience strokes who visited our hospital for a medical examination from January 1, 2008 to April 30, 2010 except patients whose body constitutions were undetermined according to QSCCII. We investigated the correlation between serum cholesterol values, blood pressure, body mass index(BMI), homosistein, hs-CRP and PWV. Pearson's correlation and partial correlation analysis were applied to examine the relationship between PWV and risk factors of atherosclerosis. Result : Among the 160 subjects, 54 were Taeumin, 54 were Soyangin, and 52 were Soeumin. The prevalences of high BMI (P-value <0.01), high hs-CRP(P-value <0.05), and high PWV(P-value <0.05) of Taeumin were higher than those of the other constitutions. PWV of carotid-femoral artery was significantly different among the three constitutional groups(Taeumin: $8.12{\pm}1.64m/sec$, Soyangin: $7.48{\pm}1.16m/sec$, Soeumin: $7.49{\pm}1.12m/sec$)(P-value <0.05). This research has show a statistical significance between the average amount of carotid-femoral artery PWV that is higher in Taeumin. Age factor of Taeumin was the effective determinant of the increase of mean PWV of carotid-femoral arteries. Conclusions : There were significant differences in the prevalence of atherosclerosis according to Sasang constitution. This study showed that atherosclerosis was more prevalent in Taeumin. Therefore, according to our results, risk of atherosclerosis was higher in Taeumin than among other constitutions.

Dynamic elastic local buckling of piles under impact loads

  • Yang, J.;Ye, J.Q.
    • Structural Engineering and Mechanics
    • /
    • v.13 no.5
    • /
    • pp.543-556
    • /
    • 2002
  • A dynamic elastic local buckling analysis is presented for a pile subjected to an axial impact load. The pile is assumed to be geometrically perfect. The interactions between the pile and the surrounding soil are taken into account. The interactions include the normal pressure and skin friction on the surface of the pile due to the resistance of the soil. The analysis also includes the influence of the propagation of stress waves through the length of the pile to the distance at which buckling is initiated and the mass of the pile. A perturbation technique is used to determine the critical buckling length and the associated critical time. As a special case, the explicit expression for the buckling length of a pile is obtained without considering soil resistance and compared with the one obtained for a column by means of an alternative method. Numerical results obtained show good agreement with the experimental results. The effects of the normal pressure and the skin friction due to the surrounding soil, self-weight, stiffness and geometric dimension of the cross section on the critical buckling length are discussed. The sudden change of buckling modes is further considered to show the 'snap-through' phenomenon occurring as a result of stress wave propagation.

A Study on the Clinical Use of 7-zone-Diagnostic System (2) - the Comparative Analysis of the Rule and the Decipher for each Equipment - (7구역진단기의 임상응용에 대한 고찰 (2) - 각 제품에 따른 원리와 판독의 비교 -)

  • Song, Beom-Yong
    • Journal of Acupuncture Research
    • /
    • v.23 no.5
    • /
    • pp.11-21
    • /
    • 2006
  • The 7-zone-diagnostic system(ABR-2000, BIO MEDIC 700Plus, CP-6000A, OMD 3000, VEGA-DFM 722) is a diagnostic device which applies pulse signals to predetermined bodily locations. Applying alternating positive and negative stress to tissues with positive and negative pulses first manifests itself as negative and positive wave forms. This system make a diagnosis of functional disorder or some typical organic diseases include stress of the mind or the body, and the energetic situation, reserves. We are known a disorder or disease throw the result charts. And these result represents various characteristic signals are assisted diagnosis and care. These result chart contains disorder flow wave forms and some valuable diagnostic hints or marks. But we have several various products for the 7-zone-diagnostic system. I think that we need the comparative analysis of the general rule and the decipher for each equipment. Because these letters(marks) each product are different, we necessary various plentiful research and suitable statistics in these points. And we must carry out many various research in the future.

  • PDF

Measurement of Cardiac Pulse Transit Time using Photoplethysmography Sensor (광전용적맥파 센서를 이용한 맥파전달시간의 측정)

  • Choi, Byeong-Cheol;Jung, Dong-Keun;Jeong, Do-Un;Ro, Jung-Hun;Jeon, Gye-Rok
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.383-391
    • /
    • 2004
  • In this study, we implemented the pulse transit time (PTT) system to examine usefulness of the monitoring method of distensibility and elasticity using photoplethysmography sensor in vivo. PTT is defined as the time interval between the peak of QRS complex in ECG signal and the maximum slope point of photoplethysmography. these two signals were converted to digital data by means of AID converter, then PTT was evaluated by heartbeat using PC. Results of analysis were displayed as a graph using spline interpolation method. The variance of PTT was measured repetitiously to verify efficiency of PTT system in resting state and hyperemic state. Repeated measurement of PTT was not same value but showed that coefficients of correlation were related with each other as 0.8302 (P<0.01) in resting state. And also repeated measurement of PTT showed significant correlation as 0.868 (P<0.01) in the hyperemic state. These result showed that PTT is reflect on transient pressure variance in the artery and is very useful method for the evaluation of prognosis of the hypertension and arteriosclerosis.