• 제목/요약/키워드: Pulse wave analysis

검색결과 244건 처리시간 0.027초

Analysis of photothermal response in a two-dimensional semiconducting material thermally excited by pulse heat flux

  • Saeed, Tareq;Abbas, Ibrahim
    • Structural Engineering and Mechanics
    • /
    • 제82권4호
    • /
    • pp.469-476
    • /
    • 2022
  • A mathematical model of Lord-Shulman photo-thermal theorem induced by pulse heat flux is presented to study the propagations waves for plasma, thermal and elastic in two-dimensional semiconductor materials. The medium is assumed initially quiescent. By using Laplace-Fourier transforms with the eigenvalue method, the variables are obtained analytically. A semiconductor medium such as silicon is investigated. The displacements, stresses, the carrier density and temperature distributions are calculated numerically and clarified graphically. The outcomes show that thermal relaxation time has varying degrees of effects on the studying fields.

고전압 방전 충격펄스를 이용한 유용광물 회수에 관한 실험적 연구 (Experimental Study on the Recovery of Useful Minerals Using High Voltage Discharge Shock Pulse)

  • 조상호;정상선
    • 화약ㆍ발파
    • /
    • 제40권1호
    • /
    • pp.17-28
    • /
    • 2022
  • 고전압 방전에 의한 파분쇄기술 중 ED(Electrical pulse Disintegration)는 고체 내 절연파괴를 유도하여 고체 내 취약한 경계면을 분리하여 유가자원을 분리·회수하는 고효율 자원처리 기술로 알려져 있다. 본 연구에서는 고전압 방전에 의하여 고체 내 발생한 충격파가 황화광물 내 존재하는 아연광물의 단체분리특성을 분석하기 위하여, ED분쇄실험과 기계식 분쇄실험을 수행하고 분쇄산물에 대한 SEM-BSE 분석과 Microfocus X-Ray CT 분석을 수행하여 단체분리도를 비교하였다.

두 개의 광전용적맥파 기반의 수축기 혈압과 이완기 혈압 추정 융합 알고리즘 모델 분석 (Analysis of the Convergence Algorithm Model for Estimating Systolic and Diastolic Blood Pressure Based on Two Photoplethysmography)

  • 김선칠;조성현
    • 한국융합학회논문지
    • /
    • 제10권8호
    • /
    • pp.53-58
    • /
    • 2019
  • 최근 만성질환자 건강관리의 목적으로 혈압측정에 대한 접근성을 높이는 제품 연구가 지속적으로 이루어지고 있다. 기존 연구에서는 심전도(ECG)와 광전용전맥파(PPG)를 분석하여 수축기혈압과 이완기 혈압을 산출하는 방식을 사용하고 있다. 주 과제는 정확도와 재현성을 위한 분석 알고리즘 개발이다. 본 연구에서는 초소형 혈압측정장치를 개발하는 단계에서 장치의 크기를 줄이고 측정방법도 간단히 하는 동시에 알고리즘도 두 개의 PPG만을 이용하여 최고혈압(SBP)을 추출하고 이에 따른 최저혈압(DBP)을 구하고자 하였다. 이를 위해 두 개의 PPG에서 얻은 측정값과 SBP, DBP 관계를 통계적으로 추적하여 상호관계를 분석하였다. PPG의 차이 값인 DF_P는 SBP와 반비례 관계가 있으며, DBP와는 비례적 관계가 성립되어 알고리즘에 의해 혈압값을 유추할 수 있으며, SBP를 통해 DBP를 추적할 수 있다.

복제 방지용 PUF의 전자계 해석 방안 (Consideration of EM Analysis for Unclonnable PUF)

  • 김태용;이훈재
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2012년도 춘계학술대회
    • /
    • pp.80-82
    • /
    • 2012
  • 본 논문에서는 Debye 분산 특성을 가지는 복제 방지용 PUF를 설계하기 위한 전자계 해석 방안을 고려하였다. 공기층과 분산매질(Si)로 구성된 1차원 모델 내에 전파하는 펄스를 모형하기 위해 FDTD법을 이용하였다. 불연속 경계면에 도달한 펄스는 일부 반사되고 일부는 투과되어 빠르게 감쇠되는 것으로 나타났다. 그 결과 FDTD법에 의한 Debye 분산특성을 가지는 1차원 복제방지용 PUF 설계 및 모델링에 적용 가능한 것을 확인하였다.

  • PDF

노화에 따른 동맥벽 탄성도 저하가 심실세포의 Cross-bridge 동역학에 미치는 영향에 대한 수치적 연구 (Numerical analysis of the effect of the age-related increase of arterial wall stiffness on the Cross-bridge dynamics of the cardiac myocyte)

  • 전형민;심은보
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1674-1678
    • /
    • 2008
  • 본 연구에서는 심장의 세포 변화에서부터 혈류 순환의 시스템 변화까지 일련의 과정을 시뮬레이션 할 수 있는 통합모델을 개발하였다. 본 통합 모델을 이용하여 대동맥의 탄성도 변화 따른 Pulse Wave Velocity를 추정하였으며 심근의 수축 Mechanics의 변화를 시뮬레이션 하였다. 심장은 단순한 구 형상으로 모델링 되었다. 특히 동맥순환의 특성인 Wave propagation 과 Wave deflection의 현상을 모델링하기 위해 기존 모델에서 사용된 동맥계 순환 모델을 수정하였다. 즉 기존의 동맥 모델을 1차원의 운동방정식과 연속방정식을 기반으로 하는 Distributed arterial model로 대체하였다. Distributed arterial model은 혈액의 점성에 의한 에너지 손실, 혈관의 점탄성 효과 그리고 분지 되는 혈관에서의 에너지 손실을 포함하는 정교한 동맥 순환 모델이다. 정교한 동맥계 순환 모델의 동맥 탄성도 값을 조절함으로써 탄성도 변화에 대한 PWV를 계산 할 수 있었다. 이러한 수치적 방법을 사용하여 노화에 따른 동맥벽 탄성도의 저하가 심근세포의 Cross-bridge 동역학에 미치는 영향을 시뮬레이션 하였다.

  • PDF

유도초음파를 이용한 대구경 배관 적용에 관한 연구 (Application of Thin-Walled Tubes Using Guided Wave)

  • 박상기;이영호
    • 동력기계공학회지
    • /
    • 제12권1호
    • /
    • pp.58-65
    • /
    • 2008
  • A method to test thin-walled tubes by guided ultrasonic wave is reported. The principle is that applicate two types of axially symmetric ultrasonic tube modes and "longitudinal" modes with particle displacement, which is coupled in axial and radial directions for transverse failures and torsional modes, oscillating in the circumferential direction only, for longitudinal failures. Both types of modes propagate along the tube in the axial direction. Therefore, a pulse-echo technique is possible. The pulses are excited and received at one end of the tube without contact electro-dynamic transducers. As soon as the tubes is put into a transducer coil at one end, the test of the whole tube can be accomplished in a few milliseconds. It is not necessary to rotate and transport the tubes during the test.

  • PDF

동맥경화 평가를 위한 연령별 맥파 주요인자 분석 (Analysis of Pulse Wave Parameters According to Aging for Arteriosclerosis Evaluation)

  • 이나라;이승욱;김수병;이용흠
    • Korean Journal of Acupuncture
    • /
    • 제28권4호
    • /
    • pp.79-89
    • /
    • 2011
  • Objectives : The aim of this study is to propose the W area of pulse (AW) as a new index which can confirm the arteriosclerosis by analyzing parameters of 5-level pressure pulse waveform measurement system for normotensive group according to aging. Methods : We measured radial pulse waveforms of normotensive group (20 to 60 years old) using 3-dimensional pulse imaging analyser (DMP-3000, DAEYOMEDI Co., Korea). And then we analyzed various parameters for sclerosis of the arteries such as Height (h1, h2, h3, h4, h5), Time (t1, t2, t3, t4, t5), AW, AW rate, Total area of pulse (At) and Augmentation Index (AIx). Results : As a result of analyzing parameters according to the aging, h2, h3, AS (systolic area rate to AT), AIx and AW were increased but t2/t, t3/t, t5/t and AD (diastolic area rate to AT) were decreased. Conclusions : We checked blood vessel conditions for normotensive group according to aging and confirmed various parameters. Also, we found that AW was analogous to AIx which has been used for diagnosing arteriosclerosis. Furthermore, we confirmed the usefulness of AW as a new parameter for checking vessel condition and characteristic compared with the AIx.

Structural damage detection through longitudinal wave propagation using spectral finite element method

  • Kumar, K. Varun;Saravanan, T. Jothi;Sreekala, R.;Gopalakrishnan, N.;Mini, K.M.
    • Geomechanics and Engineering
    • /
    • 제12권1호
    • /
    • pp.161-183
    • /
    • 2017
  • This paper investigates the damage identification of the concrete pile element through axial wave propagation technique using computational and experimental studies. Now-a-days, concrete pile foundations are often common in all engineering structures and their safety is significant for preventing the failure. Damage detection and estimation in a sub-structure is challenging as the visual picture of the sub-structure and its condition is not well known and the state of the structure or foundation can be inferred only through its static and dynamic response. The concept of wave propagation involves dynamic impedance and whenever a wave encounters a changing impedance (due to loss of stiffness), a reflecting wave is generated with the total strain energy forked as reflected as well as refracted portions. Among many frequency domain methods, the Spectral Finite Element method (SFEM) has been found suitable for analysis of wave propagation in real engineering structures as the formulation is based on dynamic equilibrium under harmonic steady state excitation. The feasibility of the axial wave propagation technique is studied through numerical simulations using Elementary rod theory and higher order Love rod theory under SFEM and ABAQUS dynamic explicit analysis with experimental validation exercise. Towards simulating the damage scenario in a pile element, dis-continuity (impedance mismatch) is induced by varying its cross-sectional area along its length. Both experimental and computational investigations are performed under pulse-echo and pitch-catch configuration methods. Analytical and experimental results are in good agreement.

추진기관의 라이너/추진제 미접착 검출 기법 연구 (Study on the Debonding Detection Techniques of Liner/Propellant Interface of Rocket Motor)

  • 김동륜;류백능
    • 한국추진공학회지
    • /
    • 제12권2호
    • /
    • pp.40-47
    • /
    • 2008
  • 초음파를 이용한 추진기관의 접착 계면 검사는 결함 검출 능력과 경제성이 우수하다고 알려져 있다. 하지만, 추진기관의 접착 구조는 다중 계면이므로 송신 펄스와 수신 펄스의 시간 간격이 짧아서 반사 신호의 분리가 어렵기 때문에 초음파의 신호 분석에는 많은 시간과 노력이 소요된다. 이런 이유로 추진기관의 초음파시험은 연소관과 내열재 사이의 미접착 결함과 같이 극히 제한된 영역에 대해서만 자동화 시스템으로 수행하고 있다. 본 논문에서는 기존의 초음파시험으로 검출이 불가능했던 라이너와 추진제 미접착 결함을 초음파의 공진 현상과 램파 특성을 이용하여 검출하는 새로운 기법에 대해 기술하였다.

Association of Uric Acid Levels with Arterial Stiffness in Korean Women and Non-smoking Men

  • Sull, Jae Woong;Koh, Eun Na;Cho, Sung Kweon;Bae, Hyung-Joon;Jee, Sun Ha
    • 대한의생명과학회지
    • /
    • 제23권3호
    • /
    • pp.201-207
    • /
    • 2017
  • Measuring the pulse wave velocity (PWV) is a non-invasive method for evaluating the stiffness of the vessel wall. While previous studies investigated the association of uric acid level with arterial stiffness, most did not consider smoking status and obesity as covariates. The objective of this study was to investigate the relationship between uric acid levels and arterial stiffness, considering smoking status and obesity. We studied 3390 subjects (1940 males and 1450 females). Abnormal PWV was also defined as the highest quartile of values in the subjects. Data were analyzed using Pearson correlation, t-test, and multiple regression analysis. Approximately 41.9% of men and 3.7% of women were current smokers. Prevalence of hypertension was 11.4% in men and 7.0% in women. In women, hyperuricemia was associated with abnormal PWV (OR 1.58; 95% CI 1.03~2.43). Hyperuricemia was also associated with abnormal PWV (OR 2.37; 95% CI 1.01~5.59) in non- or light male smokers with normal blood pressure. This study suggests that uric acid is associated with arterial stiffness in women and non-smoking men.