• Title/Summary/Keyword: Pulse test

Search Result 1,181, Processing Time 0.025 seconds

Electrical Switching Characteristics of Ge1Se1Te2 Chalcogenide Thin Film for Phase Change Memory

  • Lee, Jae-Min;Yeo, Cheol-Ho;Shin, Kyung;Chung, Hong-Bay
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.1
    • /
    • pp.7-11
    • /
    • 2006
  • The changes of the electrical conductivity in chalcogenide amorphous semiconductors, $Ge_{1}Se_{1}Te_{2}$, have been studied. A phase change random access memory (PRAM) device without an access transistor is successfully fabricated with the $Ge_{1}Se_{1}Te_{2}$-phase-change resistor, which has much higher electrical resistivity than $Ge_{2}Sb_{2}Te_{5}$ and its electric resistivity can be varied by the factor of $10^5$ times, relating with the degree of crystallization. 100 nm thick $Ge_{1}Se_{1}Te_{2}$ thin film was formed by vacuum deposition at $1.5{\times}10^{-5}$ Torr. The static mode switching (DC test) is tested for the $100\;{\mu}m-sized$ $Ge_{1}Se_{1}Te_{2}$ PRAM device. In the first sweep, the amorphous $Ge_{1}Se_{1}Te_{2}$ thin film showed a high resistance state at low voltage region. However, when it reached to the threshold voltage, $V_{th}$, the electrical resistance of device was drastically reduced through the formation of an electrically conducting path. The pulsed mode switching of the $20{\mu}m-sized$ $Ge_{1}Se_{1}Te_{2}$ PRAM device showed that the reset of device was done with a 80 ns-8.6 V pulse and the set of device was done with a 200 ns-4.3 V pulse.

The Study of Latch-up (펄스감마선에 의한 DC/DC 컨버터의 Latch-up현상에 대한 연구)

  • Oh, Seung-Chan;Lee, Nam-Ho;Lee, Heung-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.719-721
    • /
    • 2012
  • In this study, we carried out transient radiation experiments for identify failure situation by a transient radiation effect on DC/DC converter device due to high energy ionizing radiation pulse induced to electronic device. This experiments were carried out using a 60 MeV electron beam pulse of the LINAC(Linear Accelerator) facility in the Pohang Accelerator Laboratory. In this experiment, we has found that the latch-up phenomena could be checked in more than $1.0{\times}10^8$rad(si)/sec condition.

  • PDF

Pressure Control Characteristics of a 2-Way Solenoid Valve Driven by PWM Signal (2방향 전자밸브의 PWM 신호에 의한 압력제어 특성)

  • Jeong, Heon-Sul;Kim, Hyoung-Eui
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.8
    • /
    • pp.1565-1576
    • /
    • 2002
  • By way of driving a 2-way on/off solenoid hydraulic valve with a pulse width modulation (PWM) signal, control of the pressure in a certain volume is frequently used in various applications. However, the pressure built-up according to the duty ratio and carrier frequency of the PWM signal is not so well understood. In order to clarify the characteristics of 2-way valve hydraulic pressure control systems, in this paper two formula fur the mean and ripple of the load pressure were derived through theoretical analysis. And the accuracy of the derived formula were verified by comparison with the experimental test result. Generally 2-way valve systems are constructed as a bleed-off circuit, while 3-way valves are used as a control element in a meter-in circuit pressure control system. In a bleed-off circuit, the system supply pressure from a hydraulic power pack does not remain constant, but changes according to their external load. In turn, the relief valve in the hydraulic power pack reacts accordingly showing complicated dynamic behavior, which makes an analytical study difficult. In order to resolve the problem, simple but accurate empirical dynamic models fer a bleed-off system were used in the course of formula derivation. As the result, selection criteria for two major control parameters of the driving signal is established and the basic strategy to suppress the unnecessary pressure fluctuation can be provided for a hydraulic pressure control system using a 2-way on/off solenoid valve.

Effect of light and sediment grain size on the vertical migration of benthic diatoms

  • Du, Guo Ying;Oak, Jung-Hyun;Li, Hongbo;Chung, Ik-Kyo
    • ALGAE
    • /
    • v.25 no.3
    • /
    • pp.133-140
    • /
    • 2010
  • Using chlorophyll fluorescence, the vertical migration of benthic diatoms responding to light intensity and affected by sediment grain size was studied. Minimal fluorescence ($F_o$) of surface sediment was measured by imaging pulse amplitude modulated (Imaging-PAM) fluorometer, and used to monitor diatom biomass variation in surface sediments. The test diatoms, Amphora coffeaeformis (C. Agardh) K$\ddot{u}$tzing and Cylindrotheca closterium (Ehrenberg) Reimann & Lewin, migrated to the sediment surface under irradiance from 50 to 500 ${\mu}mol$ photons $m^{-2}s^{-1}$. However, the diatoms exhibited no evident increase of surface biomass under dark conditions, and even showed slightly decrease of surface biomass under irradiances over 1,000 ${\mu}mol$ photons $m^{-2}s^{-1}$. The light intensity inducing the maximum surface migration of A. coffeaeformis was 100 ${\mu}mol$ photons $m^{-2}s^{-1}$, while the light intensity producing the same effect for C. closterium was 250 ${\mu}mol$ photons $m^{-2}s^{-1}$. C. closterium showed higher motility than A. coffeaeformis. Faster diatom surfacing was observed in larger grain size sediments (125-335 ${\mu}m$) than smaller ones (63-125 ${\mu}m$). This study confirmed the significant influence of light as a main triggering factor behind migration, indicated the distinct effect of different sediment grain size, and highlighted the species-specific migratory ability.

A Study on Men's 8-Constitutional Characteristics Using the Oneway Analysis of Variance (일원배치 분산분석을 응응한 남자의 한의학적 8체질 임상특성 연구)

  • Rhee Sang-Beom;Park Young-Bae;Choi Kyung-Mee
    • The Korean Journal of Applied Statistics
    • /
    • v.19 no.2
    • /
    • pp.203-215
    • /
    • 2006
  • In Oriental Medicine, there have been a number of researches in 8-Constitution medicine which classifies human bodies into one of 8 categories. Since the diagnosis of 8-Constitution depending on pulse types is often subjective, standardization of the diagnosis and therapy requires objective characteristics of 8 constitutions. A questionnaire of 80 items about personal symptoms were given to patients while they were classified into one of 8 constitutions based on their pulse types and responses to constitution-based acupuncture therapy. One-way analysis of variance and Duncan's multiple comparison test were used to verify the significant items. Most of the significant items in this study coincided with supposed-to-be clinical characteristics of 8-constitutions.

Quantitative Evaluation for Improvement Effects of Performance After Mechanical Rehabilitation Treatments on Agricultural Groundwater Well (농업용 관정의 기계적 처리 이후 성능 개선 효과의 정량적 평가 사례)

  • Song, Sung-Ho;Lee, Byung-Sun;An, Jung-Gi
    • Journal of Soil and Groundwater Environment
    • /
    • v.21 no.4
    • /
    • pp.42-49
    • /
    • 2016
  • Step-drawdown pumping tests for identifying the improvement of groundwater well performance after rehabilitation treatments were conducted in three longstanding wells. Three selective mechanical treatment methods including power bubble, high-voltage electric pulse, and air surging were applied to these wells and the applicability of these methods to secure additional groundwater resources were evaluated quantitatively. Commonly, drawdown at final stage of stepdrawdown pumping tests after rehabilitation decreased by as much as 0.61~0.70 meters compared to those before rehabilitation. In addition, final specific drawdown values of three wells increased from 9% to 14% after rehabilitation. Formation loss coefficient and well loss coefficient decreased to 6.1% and 60.6%, respectively, indicating some clogging materials by precipitation/corrosion/microbe within pores of aquifer materials, gravel packs, and screens were effectively removed by applied methods. Decrease of formation loss coefficient was higher in the well applied by the power bubble method meanwhile high-voltage electric pulse method demonstrated the higher decrease of well loss coefficient. Additionally secured groundwater amounts after rehabilitation ranged from 23.3 to 32.1 m3/day, which account for 8~16% of initially developed pumping rates of the wells. From the results of this study, the effective selection of rehabilitation treatments considering aquifer characteristics are expected to contribute to secure groundwater resources for irrigation as well as to plan systematic management program for groundwater resources in rural area.

The Effect of Pulsatile Flow on Ultrafiltration In-Vitro Study and Comparison with Roller Pump

  • Lee K.;Jeong J. H.;Mun C. H.;Lee J. C.;Min B. G.
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.5
    • /
    • pp.337-341
    • /
    • 2005
  • Blood pulsation has been reported to have an advantageous effect on extracorporeal blood circulation. However, the study of pulsatile blood flow in renal replacement therapy is very limited. The in-vitro experimental results of pulsatile blood flow on ultrafiltration, when compared with the conventional roller pump, are described in this paper. Methods: Blood flow rate (QB) and transmembrane pressure (TMP) were considered as regulating factors that have an influence on ultrafiltration. Experiments were performed under the condition of equal TMP and OB in both pulsatile and roller pump groups, Several kinds of hollow fiber dialyzers were tested using distilled water containing chemicals as a blood substitute. Mean TMP (mTMP) varied from 10 to 90mmHg while the QB was 200ml/min. Results: Ultrafiltration rate (QUF) was found to be linearly proportional to TMP, whereas QB had little influence on QUF. In addition, QUF was higher in the pulsatile group than the roller pump group at the identical TMP. Conclusion: In the controlled test, QUF increased solely as a consequence of blood pulsation, which implies that the pulse frequency represents an additional and important clinical variable during renal replacement therapy.

A Study on Super Resolution Algorithm to Improve Spatial Resolution of Optical Signals (광신호의 공간 해상도 향상을 위한 초 분해능 알고리즘 연구)

  • Lee, Byung-Jin;Yu, Bong-Guk;Kim, Kyung-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.1
    • /
    • pp.71-77
    • /
    • 2018
  • The optical time domain reflectometer (OTDR) is the most widely used method to monitor problems with currently installed optical fibers. The OTDR is an instrument designed to test the FTTx network and evaluates the physical properties of the fiber, such as transmission loss and connection loss. It is important to improve the spatial resolution in order to accurately grasp the optical path problems by using the OTDR. When the pulse width is less than twice the distance between the two reflectors, the signals reflected from the two reflectors are reflected without overlap, so that the reflected signal can be distinguished. However, when the pulse width is larger than twice the distance between the two reflectors, so that the reflected signal can not be distinguished. In order to overcome these limitations, this paper proposed a method of improving spatial resolution by applying a super resolution algorithm. As a result of the simulation, the resolution is improved when the super resolution algorithm is applied, and the event interval can be analyzed more precisely.

Ground Penetrating Radar System for Landmine Detection Using 48 Channel UWB Impulse Radar (지뢰탐지용 48채널 배열 UWB 임펄스 레이더 방식 지면투과레이더시스템 개발)

  • Kwon, Ji-Hoon;Kwak, No-Jun;Ha, Seoung-Jae;Han, Seung-Hoon;Yoon, Yeo-Sun;Yang, DongWon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.12
    • /
    • pp.3-12
    • /
    • 2016
  • This paper describes the development of the ground penetrating radar (GPR) system using UWB impulse radar with 48 Channel array. GPR is an effective alternative technology to resolve th disadvantages of metal detectors. Metal detectors have a very low detection probability of non-metallic landmine and high false alarm rates caused by metallic materials under the ground. In this paper, we use the mono-cycle pulse waveform with about 600 ps pulse width to obtain high resolution landmine microwave images. In order to analyze performances of this system, we utilize indoor test facility that made up of rough sandy loam which representative Korean soil. The mimic landmine models of metal/non-metal and anti-tank/anti-personnel landmines buried in DMZ (demilitarized zone) of Korea are used to analyze the detection depth and the shape of the mines using microwave image.

Electrochromic Properties of Li+-Modified Prussian Blue (리튬이온이 첨가된 프루시안 블루의 전기변색 특성 연구)

  • Yoo, Sung-Jong;Lim, Ju-Wan;Park, Sun-Ha;Won, Ho-Youn;Sung, Yung-Eun
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.2
    • /
    • pp.126-131
    • /
    • 2007
  • The durability problem of Prussian blue in non-aqueous $Li_+$-based electrolytes has been due to the degradation of the Prussian blue electrode matrix during the insertion/extraction processes by $Li_+$. In this work, we designed and synthesised the Prussian blue without reducing the electrochromic performance in non-aqueous $Li_+$-based electrolytes. Prussian blue was electrodeposited on a glass which has ITO coating, and the coating solution is a mixture solution of $FeCl_3\;and\;K_3Fe(CN)_6$ with deionized water added HCl, KCl, and LiCl, respectively. The durability of Prussian blue was evaluated by an in-situ transmittance measurement during a continuous and pulse potential cycling test, and measured by electroactive layer thickness due to evaluating the degradation.