• Title/Summary/Keyword: Pulse test

Search Result 1,181, Processing Time 0.036 seconds

Development and rotating test of the high temperature superconducting motor with on-board cryocooler (탑재형 냉동기를 이용한 고온 초전도 모터 개발 및 회전 실험)

  • Ki, Tae-Kyung;Kim, Young-Kwon;Kim, Hee-Sun;Jeong, Sang-Kwon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.13 no.1
    • /
    • pp.12-16
    • /
    • 2011
  • In this paper, the prototype of the HTS motor with an on-board cryocooler, is fabricated and tested. The overall system is composed of the stator with conventional copper winding, the rotor with superconductor, and the rotating cryocooler designed from the on-board concept. The rotor is fabricated as the race-track coil with 2G, YBCO tape and contacts with the on-board cryocooler while being rotated together. An inline-type pulse tube refrigerator is used as the on-board cryocooler. The cryocooler is fabricated from optimal process to satisfy the structure and thermal stability of the on-board system. Each component is integrated according to carefully defined sequence. Specially, a combining method of torque tubes is an important part for sustaining stability of the rotor and the cryocooler. In the rotating test, the HTS motor is successfully operated with 240 rpm of rotating speed when 75 A current is supplied to the superconducting rotor. In this paper, potential problems of the HTS motor system using the on-board cryocooler are proposed and solved, and realistic possibility of this concept is also confirmed.

The Effect of Recorded Mother's Voice on the Body Weight and Physiological Reactions of the Premature Infants (신생아 중환자실 미숙아에게 엄마목소리 제공이 미숙아의 체중과 생리적 반응에 미치는 효과)

  • Kang, In-Soon;Kim, Young-Hee
    • Journal of Korean Biological Nursing Science
    • /
    • v.13 no.2
    • /
    • pp.94-101
    • /
    • 2011
  • Purpose: The purpose of this study is to examine effects of Recorded Mother's Voice on weight and physiological reactions to the premature infants. Methods: This study was conducted on the nonequivalent control group pre-posttest quasi-experimental design and the subject group was the premature infants who were admitted in Neonatal Intensive Care Unit in Pusan National University Hospital. Total 50 infants, divided into two groups 25 experimental and control were participated in the study. The data were analyzed using frequency, %, chi-square test, t-test between the two groups. Results: The results of this study were as followingsfollowings; In the physical response(heart rate, respiration rate, pulse oximetry saturation), there were significant statistical difference between two groups. Conclusion: In short, it turned out that the intervention of the recorded mother's voice had some significance as nursing intervention with positive impacts. Such as improving infant's growth and stablizing their physical response. By providing the effectiveness of such intervention, the study will further provide the evidence-based information in developing the practice of pediatric nursing.

The Effects of Dance Sports Program on Health Promotion in Rural Women (댄스스포츠 프로그램이 농촌여성의 건강증진에 미치는 효과)

  • Kim, Dong-Oak;Lee, Hyeon-Soon;Kwon, Young-Sook
    • Journal of Korean Biological Nursing Science
    • /
    • v.14 no.2
    • /
    • pp.84-93
    • /
    • 2012
  • Purpose: This study was performed to identify the effects of dance sports programs on the parameters of health promotion (blood pressure, pulse, glucose, blood lipids, musculoskeletal pain, fatigue, self-efficacy, and depression) in rural women. Methods: A non-equivalent control group pretest-posttest experimental design was used. The study subjects were 38 women who were aged 45-78 and cultivating perilla leaves in a rural area. An experimental group (n=20) received the dance sports program from December 3rd, 2009 to June 3rd, 2010 and a control group (n=18) did not. Data was collected 3 times (before the program, 12 during and 24 weeks after the program) and were analyzed with $X^2$ test, t-test, and Repeated Measures ANOVA using SPSS/WIN 18.0. Results: For the experimental group, significant improvement was found in high density lipoprotein cholesterol (HDL-C), low density cholesterol (LDL-C), triglyceride (TG) musculoskeletal pain, fatigue, self-efficacy, and depression as compared to the control group. Conclusion: The findings of the study indicates that the dance sports program is effective on health promotion for rural women. Therefore, dance sports programs can be recommended for health promotion of rural residents.

The Experiment of High Voltage Capacitor Charger for Pulsed Power Application (펄스전원용 고압커패시터 충전기 시험)

  • Jang, S.R.;Ahn, S.H.;Ryoo, H.J.;Kim, J.S.;Kim, Y.B.;Kim, J.S.;Lee, B.H.;Kim, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1025_1026
    • /
    • 2009
  • This paper introduces the test a rapid pulsed power charging system for pulsed power application. The charger is designed based on three-phase series resonant inverter followed by air cooled step-up transformers. It has many advantages of lower weight, small size and high efficiency compared with large bulky traditional pulse power charging system. To apply 150kJ pulsed power system, detail test was carried out at various condition and its results shows 90% efficiency at full load condition. And additional experiments such as short, open, and self discharging during charging status are performed to verify reliable operation at abnormal condition and it was confirmed that developed capacitor charger showed very reliable operation all over the tests.

  • PDF

IMPROVEMENT OF GAS TUNGSTEN ARC WELDABILITY FOR FERRlTIC STAINLESS STEELS

  • Cui Li;Jeong, Ho-shin;Park, Byung-Il;Kim, Sung-Kab
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.107-112
    • /
    • 2002
  • Ferritic stainless steels would be the most important alloys under the chloride environment. They are a cheaper alternative to austenitic stainless steels [1]. The present study is related to gas tungsten arc welding (GTAW) characteristics of Type 444 stainless steels. The heat of welding leads to grain coarsening in the HAZ and in the weld metal of ferritic stainless steels because they solidify directly from the liquid to the ferritc phase without any intermediate phase transformation. It is therefore recommended that these alloys be welded with a low heat input and at high welding speeds. Attempts to improve weldability were made by using of direct current straight polarity (DCSP) and pulsed current GTAW processes in this study. Measuring weld bead, grain size and Erichsen test were performed and the effects of heat input, pulse frequency on the weld metal and HAZ were studied. The main results were obtained as followings: decreasing heat input was effective to control the width of weld both in DCSP welding and in pulsed current welding; pulsed current welding was found to refine the grain size effectively and the finest grain size was found at the frequency of 150Hz in pulsed current welding; it was found that decreasing heat input also refine the HAZs effectively and the frequency had no different effect on HAZ at the same heat input; the ductility could be improved effectively in pulsed current welding.

  • PDF

Scheme for Measuring Refrigeration Capacity of Cryopump Refrigerator (크라이오 펌프 냉동기 냉각용량 측정방안)

  • In, S.R.;Cho, H.S.;Jeong, S.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.4
    • /
    • pp.243-251
    • /
    • 2011
  • An apparatus for measuring the refrigeration capacity of cryopump refrigerators including the pulse tube type being developed domestically and the GM type has been designed, manufactured, and tested. The refrigeration capacity of a commercial refrigerator was evaluated for confirming the measurement procedure and the operation performance of the apparatus. The measured 2-D refrigeration capacity chart showed the intrinsic characteristics of the refrigerator model used in the experiment. In this paper, design specifications and test results of the refrigeration capacity measurement system is reported and discussed.

The Effect of Music Therapy on Postoperative Pain in Patients with Total Hip Replacement (음악요법이 전고관절 대치술 환자의 수술 후 통증에 미치는 영향)

  • Park, Jeong Sook;Yeom, Ji Ho;Shin, Hye Jeong
    • Korean Journal of Adult Nursing
    • /
    • v.18 no.2
    • /
    • pp.183-193
    • /
    • 2006
  • Purpose: The purpose of the study was to test the effects of music therapy on postoperative pain in patients with total hip replacement. Method: The research design was a nonequivalent control group pretest-posttest design. The subjects were composed of thirty patients with total hip replacement. Fifteen of them were assigned to the experimental group and fifteen to the control group. Fifteen minutes tailored music therapy was given to the experimental group during five consecutive days. The instruments used for this study were pain NRS(numerical rating scale). The data were analyzed using percent, mean, standard deviation, ${\chi}^2-test$ and repeated measure ANOVA using SPSS WIN 11.0. Results: Hypothesis 1 "The score of pain NRS of experimental group will be lower than those of control group" was accepted(F=15.945, p<.001). Hypothesis 2 "The frequency of PCA analgesics of experimental group will be fewer than those of control group" was accepted (t=-2.312, p=.028). Hypothesis 3 "The vital signs(pulse, systolic BP and diastolic BP) of experimental group will be different from those of control group" was rejected. Conclusion: This music therapy can be recommended as an efficient nursing intervention to reduce postoperative pain in patients with total hip replacement.

  • PDF

Development of a Finite Element Model for Frontal Crash Analysis of a Large-Sized Truck (대형트럭의 정면 충돌 특성해석을 위한 유한요소모델의 개발)

  • Kim, Hak-Duck;Song, Ju-Hyun;Oh, Chae-Youn
    • Proceedings of the KSME Conference
    • /
    • 2001.11a
    • /
    • pp.489-494
    • /
    • 2001
  • This paper develops a finite element model for frontal crash analysis of a large-sized truck. It is composed of 220 parts, 70,041 nodes and 69,073 elements. This paper explains only major parts' models in detail such as frame, cab, floor, and bumper which affect on crash analysis a lot. In order to prevent penetration not only at a part itself but also between parts, all contact areas are defined using type-36, self-impact type. The developed model's reliability is validated by comparing simulation and crash test results. The results used for model validation are vehicle pulses at B-pillar, and frame and deformation of frame and cab. The frontal crash simulation is performed with the same conditions as crash test. And, it is performed using PAM-CRASH installed in super-computer SP2. The developed model whose reliability is verified may be used as a base to develop a finite element model for occupant behavior and injury coefficient analysis.

  • PDF

A study on the crack initiation of SCM 4 (SCM4 의 크랙開始点 에 관한 硏究)

  • 옹장우;박찬국;김재훈
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.2
    • /
    • pp.135-139
    • /
    • 1985
  • A J$_{IC}$ test procedure by ultrasonic method performed to observe the crack opening behavior of fatigue precrack and detect the initiation of crack propagation of compact tension specimen in this paper. Pulse-echo method with 5 MHz transducer was used on the Cr-Mo steel quenched and tempered at 593.deg. C. We obtained the following results in the elastic-plastic fracture toughness test by ultrasonic method. Echo height is a little increased linearly and rapidly at the early stage of loading . Then it is decreased considerably, finally at the unstable crack growth stage, it is rapidly increased at an unpredictable rae. The initiation of crack propagation is supposed to be at the stage deviated from linearly decreased region and then blunted. J$_{IC}$ value(10.15-12.15 Kgf/mm) by ultrasonic method is lower than that(12.2 Kgf/mm) by R-curve method. But, it is required that the research for the more exact evaluation about correlation between echo height and the crack opening behavior of precrack tip will be continued. continued.ued.

A Study on the Acoustic Baffle to Reduce Ghost Target According to Structure behind Cylindrical Array Sensor (원통형 배열센서 후면 구조물에 의해 발생하는 허위 표적 감소를 위한 음향 배플 연구)

  • Seo, Young Soo;Kim, Dong Hyun;Kim, Jin Tae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.6
    • /
    • pp.440-446
    • /
    • 2015
  • Acoustic signal is emitted from a vessel and received by a cylindrical array sensor at some distance from the vessel. Acoustic signal is the source for a cylindrical array sensor which is designed to detect the acoustic signal. Cylindrical array sensors seldom have an ideal hydrodynamic shape and are not sufficiently robust to survive without some protection and they are normally housed in a sonar dome. Reflected signals by some structure inside a sonar dome make unwanted signals. Therefore, an acoustic baffle is used to minimize unwanted signals. The performance of the acoustic baffles can be determined from the acoustic numerical analysis at the design stage. In this study, finite element method was used to analyze the acoustic field around the cylindrical array sensor and baffle effects. The baffle performance can be defined the echo reduction. To show the baffle performance, the specimens were made for pulse tube test and echo reductions were measured during the test. In this paper, the effect of echo reduction of the acoustic baffle was discussed.