• Title/Summary/Keyword: Pulse test

Search Result 1,181, Processing Time 0.036 seconds

Development of DDL(Digital Delay Line) Module Using Interleave Method Based on Pulse Recognition and Delay Gap Detection (펄스 인식 및 지연 간격 검출을 통한 인터리브 방식의 디지털 시간 지연 모듈 개발)

  • Han, Il-Tak
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.6
    • /
    • pp.577-583
    • /
    • 2011
  • Radar performance test is one of the major steps for radar system design. However, it is restricted by time and cost when radar performance tests are performed with opportunity targets. So various simulated target generators are developed and used to evaluate radar performance. To simulate the target's range, most of simulated target generators are developed with optical line or DRFM(Digital RF Memory) technique but there are many restrictions such as limit of range imitation and test scenario because of their original usage. In this paper, DDL(Digital Delay Line) module for development of simulated target generator is designed with precise range simulation and easily embodiment feature. And pulse recognition and delay gap detection technique are used to simulate the time delay without distortions. Developed DDL module performances are verified through their performance tests and test results are described in this paper.

Study for Correlation of 3D-MAC and DSOM with ABR-2000 (피부전기저항측정기(ABR-2000)의 맥진기(3D-MAC) 및 한방진단시스템(DSOM)과의 상관성 연구)

  • Song, Jung-Oh;Kim, Min-Ae;Lee, In-Seon
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.31 no.1
    • /
    • pp.57-83
    • /
    • 2018
  • Purpose: This research has been carried out to find out correlation between test results of ABR-2000 and other diagnostic equipments to enhance significance of accurate diagnosis and clinical usage of ABR-2000. Methods: Duration of the 31 months from December 2012 to June 2015, records of 564 outpatients at gynecology department have been selected. The 564 patients were tested, using all 3 different test equipments of ABR-2000, DSOM, and 3D Blood Pressure Pulse Analyzer (3D-MAC) without test errors or mis-recordings. Correlation between 3D Blood pressure Pulse Analyzer, DSOM and ABR-2000 were analyzed by frequency & ratio factor of statistic data records of patients groups devided by 8 different disease symptom and by comparison of the groups in the form of Regulation and Graph presented on ABR-2000 equipment. Results: 1. The indicator L in all 1, 2, and 3 quadrant in the graph means the activity and reactivity of the upper body biodynamics detection rate is low and which result is very common symptom among gynecological patients. 2. The portion of patients with hypermenorrhea, endometritis, and menstrual pain symptom among the indicator L group in the reactivity 1-3 quadrantin is significantly high. 3. When 3D Mac analyzer indicates H, diastole decreases while systole increases and tachycardia increases then the blood circulation is expected to increase. In case of indication L, diastole increases and systole decreases then, the blood circulation is expected to decrease.

A Comparative Study of Pulse-echo Method and TOFD Method for the Defect in the Welding Joint of the STS304 Stainless Steel (STS304 스테인리스강 용접부 결함평가에 대한 Pulse-echo법과 TOFD법의 비교연구)

  • Kil, Doo-Song;Choi, Won-Doo
    • Journal of Power System Engineering
    • /
    • v.6 no.4
    • /
    • pp.68-72
    • /
    • 2002
  • For the evaluation of a flaw in a welded stainless steel by the Time of Flight Diffraction(TOFD) Method, we have made the reference specimen for experimentation. As a result, we could analyze a specific character and the inner state of the structure in a welded stainless steel and we came to the conclusion as followed. (1) For analyze the structure state of a section in a welded stainless steel through the optical microscope, we could have analyzed the generated shape and the location of a flaw and the inner parts of the structure state through the microscope of eighty magnification and two hundred magnification about the soundness, the heat affected zone(HAZ) and the welded part. (2) Through the comparison with the shape and the size of a flaw in the welded part about the conventional ultrasonic test and the TOFD Method, we could make an observation the special character of the TOFD Method and principles. (3) We analyzed and collected the merit of the TOFD Method on the basis of the experimental result by the shape and the size of a flaw in the inner welded parts. So, we made up a base that we could use as a basic data for a similar flaw like that. Through the study as mentioned above, we could make an observation the flaw detective method and principles used in the TOFD Method.

  • PDF

Hot Firing Test of a Quadrature NEA SSD9103S1 Configuration

  • Ja-Chun, Koo;Hee-Sung, Park;Max, Guba
    • International Journal of Aerospace System Engineering
    • /
    • v.9 no.2
    • /
    • pp.1-9
    • /
    • 2022
  • The NEA release mechanism is used to provide restraint and release functions with low shock for critical deployment operations on solar arrays after launch. The GK3 solar array consists of 2 wings and 6 hold down points per panel. The NEA SSD9103S1 is a part of the GK3 solar array hold-down and release mechanism. Each NEA unit is equipped with two Z-diodes which provide power to a NEA unit connected in series after actuation of the fuse wire. This paper presents the hot firing test results of a quadrature NEA SSD9103S1 configuration. One output powers a maximum of 4 NEA SSD9103S1 units simultaneously. The necessary actuation pulse duration has been determined to meet margin requirement for thermal energy of minimum 4. Actuation thermal energy difference is about 6.6% between each half of two fired serial NEAs. Thermal energy margin at worst case is minimum 5.9 in case of an actuation pulse duration of 500 ms. Two series Zener impedance depend on current applied has been characterized by an additional actuation after all fuse wires are open circuit. Total number of actuation commands to the GK3 NEA unit reduce drastically from 24 in case of single NEA configuration down to 8 in case of parallel and quadrature NEA configurations. It can be accommodated by the existing HP2U Pyro design without any impact.

A comparative evaluation of peppermint oil and lignocaine spray as topical anesthetic agents prior to local anesthesia in children: a randomized clinical trial

  • Harika Petluru;SVSG Nirmala;Sivakumar Nuvvula
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.24 no.2
    • /
    • pp.119-128
    • /
    • 2024
  • Background: In pediatric dentistry, fear and anxiety are common among children. Local anesthetics (LA) are widely used to control pain and reduce discomfort in children during dental treatment. Topical anesthetics play a vital role in reducing pain and the unpleasant sensation of a needle puncture in children. Peppermint oil has been extensively used for various diseases. However, its anesthetic properties remain unknown. Peppermint oil, used in mouthwashes, toothpastes, and other topical preparations has analgesic, anesthetic, and antiseptic properties. This study aimed to compare and evaluate pain perception following the topical application of peppermint oil versus lignocaine spray before an intraoral injection in children, aged 8-13 years. Method: Fifty-two children, aged between 8-13 years, who required local anesthesia for dental treatment were divided into two groups of 26 each by simple random sampling (Group 1: 0.2% peppermint oil and Group 2: lignocaine spray). In both groups, physiological measurements (e.g., heart rate) were recorded using pulse oximetry before, during, and after the procedure. Objective pain measurement (Sound Eye Motor (SEM) scale) during administration and subjective measuremeant (Wong-Baker Faces Pain Rating Scale (WBFPRS)) after LA administration were recorded. This was followed by the required treatment of the child. Physiological parameters were compared between the two groups using an independent t-test for intergroup assessment and a paired t-test and repeated-measures ANOVA for intragroup comparisons. The Mann-Whitney U test was used to analyze the pain scores. Results: Intragroup mean heart rates, before, during, and after treatment were statistically significantly different (P < 0.05). However, the intergroup mean pulse rates did not differ significantly between the two groups. The mean WBFPS score in the lignocaine spray group was 4.133 ± 2.06 was statistically different from that of the peppermint oil group (0.933 ± 1.03; P < 0.001*). The mean SEM score was significantly lower in the peppermint oil group than that in the lignocaine spray group (P = 0.006). No negative effects were observed in this study. Conclusion: 0.2% peppermint oil was effective in reducing pain perception.

High-temperature ultrasonic thickness monitoring for pipe thinning in a flow-accelerated corrosion proof test facility

  • Cheong, Yong-Moo;Kim, Kyung-Mo;Kim, Dong-Jin
    • Nuclear Engineering and Technology
    • /
    • v.49 no.7
    • /
    • pp.1463-1471
    • /
    • 2017
  • In order to monitor the pipe thinning caused by flow-accelerated corrosion (FAC) that occurs in coolant piping systems, a shear horizontal ultrasonic pitch-catch waveguide technique was developed for accurate pipe wall thickness monitoring. A clamping device for dry coupling contact between the end of the waveguide and pipe surface was designed and fabricated. A computer program for multi-channel on-line monitoring of the pipe thickness at high temperature was also developed. Both a four-channel buffer rod pulse-echo type and a shear horizontal ultrasonic waveguide type for high-temperature thickness monitoring system were successfully installed to the test section of the FAC proof test facility. The overall measurement error can be estimated as ${\pm}10{\mu}m$ during a cycle from room temperature to $200^{\circ}C$.

The inner characteristics comparison analysis of each c-rate of the high power cylindrical lithium ion cell based on the shock test (C-rate별 고출력 원통형 리튬이온 원통형 셀의 충격 시험 기반 내부 특성 비교 분석)

  • Lee, Pyeong-Yeon;Kim, Jong-Hoon;Jang, Min-ho
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.383-384
    • /
    • 2016
  • 본 논문에서 shock test를 적용한 고출력 리튬이온 원통형 셀의 내부 전기화학적 특성을 비교하였다. 용량이 동일한 고출력 리튬이온 원통형 셀을 사용하여 shock test를 적용하였다. 충격 전후에 OCV (Open Circuit Voltage) 및 HPPC (Hybrid Pulse Power Characterization) 테스트 기반 방전용량 및 내부저항을 측정하였으며 이를 통해 각 고출력 리튬이온 원통형 셀의 일정한 변화율을 확보하였다.

  • PDF

The Effects of Aromatherapy Hand Massage on Anxiety before Gastroscopy (아로마테라피 손마사지가 위내시경 대상자의 검사 전 불안에 미치는 효과)

  • Lee, Hea-Sook
    • The Journal of Korean Academic Society of Nursing Education
    • /
    • v.12 no.1
    • /
    • pp.36-42
    • /
    • 2006
  • Purpose: The purpose of this study was to verify the effect of aromatherapy hand massage on the anxiety of gastroscopy clients. Method: The data were collected during the period from March 10 to May 20, 2004 at S-Hospital in Kyungi-Do. There were sixty subjects, 30 for the experimental and 30 for the control group. The data were analyzed by descriptive statistics, t-test, $X^2$-test and paired t-test with SPSS program. Result: The pulse rate was reduced significantly, but there were no significant differences in the systolic and diastolic blood pressure between two groups. The status anxiety of experimental group was lower than the control group, but there was no significant difference statistically. Conclusion: Aromatherapy could be useful in the nursing practice, and be utilized as a way of nursing intervention to reduce anxiety of the client in specific clinical situations.

  • PDF

An Experimental Study on Freezing and Thawing Resistance of Rice Straw Ash Concrete (볏짚재 콘크리트의 동결융해 저항성에 관한 실험적 연구)

  • 김영익;성찬용;김경태;서대석;남기성
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.161-166
    • /
    • 1998
  • This experiment was on purpose to estimate freezing and thawing resistance concering with developing rice straw ash concrete which were mixed rice straw ash to cement as ratio of cement weight. Freezing and thawing test was done by Method A of KS F 2456. It could estimate change of original mass, pulse velocity and dynamic modulus of elasticity during test. Test results showed that 5% filled rice straw ash concrete had the highest durability factor(DF) as 86 and from 5% to 7.5% filled rice straw ash concrete showed higher DF than normal cement concrete.

  • PDF

Shorted-Turn Diagnosis Test for Generator Rotor Windings using Low Voltage Pulse Signal (저전압 펄스신호를 이용한 발전기 회전자 턴단락 진단)

  • Lee, Young-Jun;Kim, Byung-Rae;Whang, Young-Ha
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2019_2020
    • /
    • 2009
  • A recurrent surge oscillograph(RSO) test was performed at the Taean thermal power plant on #5 turbine generator. The test was conducted using a rotor reflectometer and digital oscilloscope. A DC voltage step is applied to each end of the rotor winding in turn. Each reflected wave, at the input end of the winding, is monitored and the two waveforms are superimposed automatically and monitored on a single channel oscilloscope. As the half windings in a rotor are identical, the two waveforms monitored at each end of the rotor will also be identical for a healthy winding. A winding with a fault will cause different voltages to be monitored at the two ends.

  • PDF