• Title/Summary/Keyword: Pulse test

Search Result 1,181, Processing Time 0.037 seconds

Effects of subtraction meditation on perceived stress, self-efficacy, systolic pressure, diastolic pressure, and pulse rate in paramedic students (마음수련명상 프로그램이 응급구조학과 학생의 지각된 스트레스, 자기효능감, 혈압, 및 맥박수에 미치는 효과)

  • Lee, In-Soo;Choi, Eun-Sook
    • The Korean Journal of Emergency Medical Services
    • /
    • v.21 no.2
    • /
    • pp.89-102
    • /
    • 2017
  • Purpose: The purpose of the study was to investigate the effects of subtraction meditation on perceived stress, self-efficacy, blood pressure, and pulse rate in paramedic students. Methods: A quasi-experimental study with non-equivalent comparison groups using pre and post-test design was performed. The experimental group consisted of 27 participants who attended the meditation program, and the control group consisted of 26 non-participants of the program. The data were analyzed using SPSS/WIN 24.0. Results: There were a statistically significant differences between the experimental group and the control group in perceived stress(t=2.301, p=.026), systolic pressure(F=18.531, p=.000), diastolic pressure(F=9.745, p=.003), and pulse rate(F=33.869, p=.000) between pretest and posttest results. Conclusion: The subtraction meditation program can help reduce perceived stress, systolic pressure, diastolic pressure, and pulse rate.

Comparison of Manual Chest Compression and Chest Compression Using AutoPulseTM Device in Pre-Hospital Simulation Cardiac arrest

  • Ko, Jang-Sik;Kim, Yong-Seok;Lim, Se-Young;Kim, Soo-Tae;Kim, Keun-Hee;Hwang, Sung-Hoon;Cho, Byung-Jun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.23 no.10
    • /
    • pp.151-156
    • /
    • 2018
  • The purpose of this study was to find more effective method through comparison of manual chest compression and chest compression using $AutoPulse^{TM}$ device in pre-hospital simulation cardiac arrest. In order to achieve the purpose of the study, ambulance workers did two different style CPR in pre-hospital simulation cardiac arrest. Data analyzed by T test and ANOVA. Findings of this study are as follows. Firstly, manual chest compression is more effective than chest compression using $AutoPulse^{TM}$ device on scene. Secondly, chest compression using $AutoPulse^{TM}$ device is more effective manual chest compression in ambulance and in elevator. In conclusion, these findings provide strong evidence for the importance of hands off time and stable CPR before hospital arrival in explaining patient's prognosis. Therefore, strategies to conduct precise hands off time and stable CPR are needed to improve patient's prognosis.

Thermal Shock Behavior of TiN Coating Surface by a Pulse Laser Ablation Method

  • Noh, Taimin;Choi, Youngkue;Jeon, Min-Seok;Shin, Hyun-Gyoo;Lee, Heesoo
    • Korean Journal of Metals and Materials
    • /
    • v.50 no.7
    • /
    • pp.539-544
    • /
    • 2012
  • Thermal shock behavior of TiN-coated SUS 304 substrate was investigated using a laser ablation method. By short surface ablation with a pulse Nd-YAG laser, considerable surface crack and spalling were observed, whereas there were few oxidation phenomena, such as grain growth of TiN crystallites, nucleation and growth of $TiO_2$ crystallites, which were observed from the coatings quenched from $700^{\circ}C$ in a chamber. The oxygen concentration of the ablated coating surface with the pulse laser also had a lower value than that of the quenched coating surface by Auger electron spectroscopy and electron probe micro analysis. These results were attributed to the fact that the properties of the pulse laser method have a very short heating time and so the diffusion time for oxidation was insufficient. Consequently, it was verified that the laser thermal shock test provides a way to evaluate the influence of the thermal shock load reduced oxidation effect.

Synthesis of Silver Nanoparticles using Pulse Electrolysis in 1-n-butyl-3-methylimidazolium Chloride Ionic Liquid

  • Jeonggeun Jang;Jihee Kim;Churl Kyoung Lee;Kyungjung Kwon
    • Journal of Electrochemical Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.15-20
    • /
    • 2023
  • Ionic liquids are considered as a promising, alternative solvent for the electrochemical synthesis of metals because of their high thermal and chemical stability, relatively high ionic conductivity, and wide electrochemical window. In particular, their wide electrochemical window enables the electrodeposition of metals without any side reaction of electrolytes such as hydrogen evolution. The electrodeposition of silver is conducted in 1-n-butyl-3-methylimidazolium chloride ([C4mim]Cl) ionic liquid system with a silver source of AgCl. This study is the first attempt to electrodeposit silver nanoparticles without using co-solvents other than [C4mim]Cl. Pulse electrolysis is employed for the synthesis of silver nanoparticles by varying applied potentials from -3.0 V to -4.5 V (vs. Pt-quasi reference electrode) and pulse duration from 0.1 s to 0.7 s. Accordingly, the silver nanoparticles whose size ranges from 15 nm to ~100 nm are obtained. The successful preparation of silver nanoparticles is demonstrated regardless of the kinds of substrate including aluminum, stainless steel, and carbon paper in the pulse electrolysis. Finally, the antimicrobial property of electrodeposited silver nanoparticles is confirmed by an antimicrobial test using Staphylococcus aureus.

Hand-Yin Meridians of Unearthed Mawangdui Medical Texts Were Described by the Haptic Exploration (마왕퇴(馬王堆) 발굴(發掘) 경맥서(經脈書) 비음경(臂陰經) 연구(硏究) : 경맥(經脈)의 직접(直接) 지각(知覺))

  • SONG Seok-mo
    • The Journal of Korean Medical History
    • /
    • v.35 no.1
    • /
    • pp.87-99
    • /
    • 2022
  • The purpose of this paper is to test the hypothesis that some early Chinese meridians were described by haptic exploration of the arterial pulse. The method is as follows: First, the relevant passages of the Mawangdui medical texts, the oldest meridian monographs, are translated based on perceptual anatomy. Second, the pulse is haptically searched for in the palm, lower arm, upper arm, armpit, and torso of the human body. Finally, their locations are compared with the translation. As a result, It was confirmed that the pulse locations detected on the body were mostly consistent with the routes of the meridians described in the texts. So meridians were haptically detectable pulse routes. What is known today as the flow direction of hand-yin meridians is actually the direction of searching the pulse. Our result runs counter to Huang Longxiang's claim that the route of the meridians are virtual routes set by speculation. Our findings also dispute Vivien Shaw's claim that the meridians of Mawangdui medical texts were discovered by anatomical dissection. They also refute the claim that meridians were discovered by the extrasensory perception of the inner sight (內觀) and the subjective experience of the meridian sensitive person. The hand-yin meridians of Mawangdui medical texts are well described so that anyone can find them by touching them with their fingers.

Effects of Nurse Presence Program on Anxiety and Physiological Indicators in Patients with Gynecological Surgery (Nurse Presence 프로그램이 산부인과 수술환자의 불안 및 생리적 지수에 미치는 효과)

  • Kim, Yun Jeong;Jo, Kae Hwa
    • Journal of Korean Biological Nursing Science
    • /
    • v.16 no.4
    • /
    • pp.326-333
    • /
    • 2014
  • Purpose: This study was to examine the effects of Nurse Presence (NP) program on anxiety and physiological indicators in patients with gynecological surgery. Methods: This study used a randomized control group pre-test, post-test design. The patients were 25-65 years old who had undergone gynecological surgery with general anesthesia. The subjects were divided into an experimental group (n=30) and the control group (n=30). SPSS 21.0 was used to analyze the data with Chi-square, Fisher's exact test, t-test, and one sample t-test. Results: The results show that there were significant differences in anxiety and heart rate and were no significant differences in systolic pressure or peripheral oxygen saturation of the experimental group which received the NP program. Conclusion: Nurse Presence program decreased pulse rate which is a physiological indicator by relieving the anxiety of the patients before gynecological surgery. Thus, this intervention is effective to relieve anxiety of the patients before gynecological surgery and should be utilized in clinics.

A study on the impact pulse analysis with various shapes and materials of impactor (충격자의 형상 및 재질변화에 따른 펄스형성에 관한 연구)

  • Lee, Yeong-Sin;Kim, Dong-Jin;Gang, Geun-Hui;O, Jong-Su
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.1
    • /
    • pp.52-63
    • /
    • 1998
  • The impact programmer for impact test was designed and the impact analysis was conducted. The effects of the material and geometric parameters on the impact force and pulse shape were investigated. The impact characteristics were examined by experimental and finite element method. The impact test was conducted with free drop impact tester. The ABAQUS/Explicit 5.5 version was used for finite element analysis. The geometric parameters of the conical and dome type impact programmer were analyzed. The polyurethane impact programmers were fabricated and tested. The effects of the hardness and thickness of the impact programmer were studied. The peak acceleration and time duration of impact programmer have close correlation with the hardness, impact energy and thickness of the impactor. The experiment was good agreement with analytical predictions. The impact pulse shape generated with polyurethane impact programmer was half sine shape. The maximum impact force was proportional to impact energy. The impact acceleration was decreased with thickness of impact programmer. The maximum impact time duration level was about 2 msec.

A Sequential Design of Dual Pulse Generation System Based on Dynamic Analysis of Pulse Shape (이중충격파의 충격파형 동특성 분석에 근거한 충격시험장치의 순차적 설계)

  • Kang, Minsig;Shul, Changwon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.98-107
    • /
    • 2017
  • Electric components equipped with naval shipboards must endure mechanical shock caused by various mechanical impulsive sources. Thus the components must be designed carefully and reliability test is an essential procedure before use. In this study, a new design technology applicable to a large and heavy shock generation system which can generate various specific real mechanical shocks in specified time domain was introduced. Commonly, the shock transmitted through the wall of naval shipboard consists of dual shocks. The primary shock is of a very high amplitude and very short period half-sine form. The following shock is of an exponentially decaying harmonic form of relatively longer period. Based on the different dynamic characteristics of two shocks, we proposed a sequential design procedure to determine spring and damping coefficients of the generation system. Some numerical simulation results showed the feasibility of the proposed method.

Effects of Aroma inhalation on Blood Pressure, Pulse Rate, Sleep, Stress, and Anxiety in Patients with Essential Hypertension (아로마 흡입이 본태성고혈압 환자의 혈압, 맥박, 수면, 스트레스, 불안에 미치는 효과)

  • Choi, Eun-Mi;Lee, Kyung-Sook
    • Journal of Korean Biological Nursing Science
    • /
    • v.14 no.1
    • /
    • pp.41-48
    • /
    • 2012
  • Purpose: This experimental research explored the effects of aroma inhalation on blood pressure, pulse, sleep, stress, and anxiety in patients with essential hypertension who are taking antihypertensive medication. Methods: A pilot survey, pre-test and post-test were conducted. The data were collected from August to October, 2009. The participants were 44 patients randomly assigned to an experimental group (22 people) and a control group (22 people). The experimental group received individual instruction for aroma inhalation, which lasted for 3 minutes. They inhaled blended oils of Lavender, Majoram and Ylang Ylang (The mixed ratio was 4:3:3), three times a day, for two weeks. Data from 36 patients were used for the final analysis (20 from the experimental group, 16 from the control group). Data were analyzed using SPSS version 13.0. Results: Sleep disturbance decreased in the experimental group (t=-2.258, $p$=.030). Blood pressure, pulse, stress, and anxiety were not significantly different between the two groups ($p$ >.05). Additional analysis of the experimental group showed that physical stress and psychological stress were significantly lowered. Conclusion: Aroma inhalation is an effective paramedical intervention for patients with essential hypertension.

Research on the Multi - purpose Nd:YAG Laser Power System using LLC Converter (LLC 공진형 컨버터를 사용한 다용도 Nd:YAG 레이저 전원장치 설계)

  • Zheng, Tao;Kim, Hee-Je;Lee, Jae-cheol;Xu, Guo-Cheng
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.6
    • /
    • pp.885-890
    • /
    • 2015
  • LLC resonant converter has been widely used because of its high efficiency and high energy density. In this paper, we designed a LLC resonant converter as the main power supply of the Nd:YAG pulse laser. First harmonic approximation (FHA) is used to model the LLC resonant converter. FHA equivalent circuit model and the transfer function of the LLC resonant converter is proposed. Soft start technology is also used to suppress the surge current. The laser output simulation test result is identical with the practical test, the laser energy of every pulse can reach up to 2.5J, and the pulse per second (PPS) can be adjusted from 6 to 18. The power system is verified stable and reliable by both of the simulation and experiment results.