• 제목/요약/키워드: Pulse studies

검색결과 474건 처리시간 0.031초

담정격 및 담승격 자침이 정상 성인의 맥파변화에 미치는 영향 (The Effects of Gall Bladder Jeonggyeok and Seunggyeok on Radial Pulse Variation in Healthy Human Subjects)

  • 김윤주;강재희;윤광식;조성은;홍서진;윤지원;오서영;이현
    • Journal of Acupuncture Research
    • /
    • 제33권3호
    • /
    • pp.45-66
    • /
    • 2016
  • Objectives : The purpose of this study is to find parameters to compare the effects of Sa-Am acupuncture with gall bladder jeonggyeok and seunggyeok on radial pulse in healthy subjects. Methods : 60 healthy subjects participated in this study and divided into the gall bladder jeonggyeok group (GB+ group), the gall bladder seunggyeok group (GB- group) and the control group. Radial pulse was measured by a 3 dimensional pulse imaging system (DMP-3000) before, immediately after, 30 minutes after and 60 minutes after acupuncture on the Cun, Guan and Chi in the GB+, GB- group and at the same time for the control group. Results : 1. The GB+ and GB- group exhibited significantly increased T, M4/M1 and decreased T1/T, T2/T, T5/T, M1, M2 compared to the control group. 2. The GB+ and GB- group exhibited significantly increased H4, Ad/Ap, RAI/HR and decreased As/Ap, Aw/Ap in the right Guan and decreased pulse power volume/min in the left Guan compared to the control group. 3. The GB- group exhibited significantly decreased M3, M3/M1 and increased M4/M1, M5, M5/M1 compared to the GB+ group. The GB+ group exhibited significantly decreased T4/(T-T4) compared to the GB- group. 4. The GB- group exhibited significantly decreased H1 in the right Guan, Chi, H4, pulse area in the right Chi, H5, pulse power volume/min in the left Chi, right Chi, and increased main peak angle in the right Guan, Chi compared to the GB+ group. Conclusion : The effect of gall bladder jeonggyeok and seunggyeok in healthy humans may be observed on various parameters. The parameters analyzed in this study may be used to differentiate effects between gall bladder jeonggyeok and seunggyeok on radial pulse. Further studies on the effects of Sa-Am acupuncture using radial pulse are needed.

촌, 관, 척 위치의 맥파 특징 차이 검정에 대한 1례 (An Example of Test on Differences of Pulse Waveform Characteristics at Cun, Guan and Chi)

  • 이전;이유정;전영주;이혜정;유현희;김종열
    • 한국한의학연구원논문집
    • /
    • 제14권2호
    • /
    • pp.107-112
    • /
    • 2008
  • Although the pulse diagnosis position, Guan is apart from Cun or Chi by only $10{\sim}20$ mm at most, traditional medical doctors applies different indent pressures and even they states different pulse images are felt at Cun, Guan and Chi, To support their clinical behaviors, in this study, we tested statistically whether there are differences in pulse waveform measured at these three positions with SphygmoCor system used world widely, A 30 years old female subject without any evidence of cardiovascular diseases was involved in this experiment. Radial pulse waves were recorded at three different positions on left lower arm 10 times at three positions-Cun, Guan and Chi. With ANOVA, we tested whether, among three different positions. there are any differences in 12 parameters of radial pulse waveform and in estimated AIx(Augmentation Index) as an arterial stiffness index extracted from radial pulse waveform. As results, differences in optimal indent pressure h0 were observed at different measuring positions(P<0.001) but not significantly different. And pulse pressure his were found to be different(Chi$22.60{\pm}3.06%,\;18.60{\pm}3.37%\;and\;26.4{\pm}5.02%$ respectively. Consequently. AIx at Gwan seems to be lowest and that at Chi seems to be highest. So. we assert the AIx at Chi is likely to be overestimated. In further studies. we want to examine what make differences in these parameters between measuring positions. And it also seems to be worthy to investigate the relationship between the depth of radial artery and AIx. And, ultimately, we need to determine the best measuring process including measuring position, hold-down pressure, signal quality validation and so on. so to achieve the optimal waveform which represents subject's health condition for both western medicine and traditional medicine.

  • PDF

심혈관계 시뮬레이터 개발 동향 분석을 통한 맥파검사용기기 성능평가 시뮬레이터 연구개발 방향 모색 (A Study on the Direction of Developing a Simulator for Performance Evaluation of Pulse Wave Detectors Through a Review of the Development Status of Cardiovascular Simulators)

  • 이주연;김재영;고동현;이지원;이태희;박창원;이수경
    • 대한의용생체공학회:의공학회지
    • /
    • 제43권3호
    • /
    • pp.136-146
    • /
    • 2022
  • In this study, it is intended to provide basic data that can help develop a cardiovascular simulator for performance evaluation of pulse wave detectors by identifying the development status of domestic and overseas cardiovascular simulators. A total of 119 papers were selected by excluding duplicate literature, gray literature, and literature not related to a cardiovascular simulator. Based on the selected literature, the research trend of cardiovascular simulators was analyzed. As a result of analyzing the purpose of the study, most of the simulators were developed to evaluate the hemodynamic properties of artificial hearts and valves. In addition, it was used for simulation evaluation or hemodynamic studies such as pulse wave studies. As a result of analyzing configurations of the simulators, a heart most often consisted of only one left ventricle. For blood vessels, the Windkessel model was most often constructed using chambers and valves. In most studies, blood was reproduced by mixing glycerin and water to reproduce both density and viscosity. In addition, as a result of analysis from the perspective of medical device performance evaluation, simulators for evaluating artificial heart and artificial valves have been studied a lot, whereas simulators for blood pressure, pulse wave, and blood flow devices have been relatively insignificant. Based on the review results, we suggested considerations when developing a simulator for performance evaluations of a pulse wave detector.

팔체질 의학에 대한 논문 리뷰 (Review on Eight Constitution Medicine)

  • 이주호;김희주;신용섭;박영재;박영배
    • 대한한의학회지
    • /
    • 제33권1호
    • /
    • pp.90-106
    • /
    • 2012
  • Objectives: Eight constitution medicine (ECM), which was first introduced in 1965, has been further developed and refined over the decades, and has consolidated its foundation through many studies on theories, diagnosis and clinical application. However, there have been few reviews on dissertations of ECM. In this study, we reviewed previously published studies related to ECM. Methods: We reviewed a total of 55 ECM-related studies published from 1965 to 2010 found on PubMed and various domestic Oriental medicine journals. Each thesis was classified as a theoretical, diagnostic, or remedy-related study. Results: 1. In the review of theoretical studies, shortly after ECM's introduction in 1965 by Kwon, the authors found studies on constitutional diseases, diets and food table which helped establish the background of ECM. ECM has further developed by comparing its theories with Sasang constitutional medicine, Huang-di-nei-jing, Saam, and Taegeuk acupuncture theories. 2. Research on diagnosis has been focused on its objectivity and accuracy. Constitution could be diagnosed by pulse-taking. To compensate for the lack of accuracy innate in pulse-taking, the Eight Constitution Questionnaire has been invented. 3. Remedies can be largely divided into acupuncture and diet. There were case studies comparing treatment effect of ECM acupuncture to other treatments. Diet related studies were carried out in the fields of immunology and nutrition. Conclusions: The authors reviewed studies that contributed to improved understanding of theories and clinical implications of ECM. Although there were various approaches to its theoretical and clinical grounds, more clinical research is needed. There is also a need to evaluate the accuracy of the experts' diagnoses of the constitution. The relationship between the diet and constitution also needs further research.

자기 임피던스 센서를 이용한 맥박 측정 장치 (A monitoring apparatus for pulse shape of human heartbeats by magnetic impedance sensors)

  • 김청월;구본주;김종성
    • 센서학회지
    • /
    • 제15권2호
    • /
    • pp.77-83
    • /
    • 2006
  • A monitoring apparatus for pulse shapes of human heartbeats has been developed using an amorphous MI(Magnetic Impedance) sensor. The pulse shapes are successfully obtained from voltage signals due to the variations of magnetic impedance in the amorphous MI sensor, which is attached to a patient's wrist. This voltage signal was fed into a signal processing module to extract the pulse shapes of heartbeats. The signal processing module, which is proposed to detect a weak variations of impedance in MI sensor under a noisy measurement environment, consists of a high frequency current source, an amplifier stage and a synchronous detection circuit. To evaluate the characteristics of a newly developed apparatus, various experiments were performed. The experimental results show that the developed apparatus could be used as a diagnosis tool for traditional Korean medicine with further systematic clinical studies.

The Correlation of Pulse Wave Velocity and Atherosclerotic Risk Factor in Stroke Patients

  • Jin, Bok Hee;Han, Min Ho
    • 대한임상검사과학회지
    • /
    • 제47권1호
    • /
    • pp.28-34
    • /
    • 2015
  • Pulse wave velocity (PWV) is used to non-invasively estimate the severity of arteriosclerosis by measuring arterial stiffness. Increased arterial stiffness measured by PWV stands for progressive arteriosclerosis and is caused by atherosclerotic risk factors. This study is focused on how brachial-ankle pulse wave velocity (baPWV) is related to the leading risk factors for arteriosclerosis or atherosclerosis. Subjects were 114, 69 males and 45 females who are in 60's and had baPWV test for acute stroke. The results are as follows: the group with increased arterial stiffness showed significant increase in HbA1c, total cholesterol, BSBP (brachial artery systolic blood pressure), BDBP (brachial artery diastolic blood pressure), CSBP (central artery systolic blood pressure), CDBP (central artery diastolic blood pressure), augmentation index (AIx) and diabetes mellitus. Correlation analysis between baPWV and atherosclerotic risk factor showed significant relationship in age, HbA1c, LDL cholesterol, BSBP, BDBP, CSBP, CDBP and augmentation index. baPWV was independently related to age and BSBP in multiple linear regression analysis. The group with increased arterial stiffness was independently related to BDBP in multiple logistic regression analysis. This study might be meaningful in evaluating the relationship between arterial stiffness and atherosclerotic risk factor in a new way, and be helped to make various studies for cardiovascular disease.

Effects of a Static Synchronous Series Compensator (SSSC) Based on a Soft Switching 48-Pulse PWM Inverter on the Power Demand from the Grid

  • Ustun, Taha Selim;Mekhilef, Saad
    • Journal of Power Electronics
    • /
    • 제10권1호
    • /
    • pp.85-90
    • /
    • 2010
  • In this paper the effects of a Static Synchronous Series Compensator, which is constructed with a 48-pulse inverter, on the power demand from the grid are studied. Extensive simulation studies were carried out in the MATLAB simulation environment to observe the compensation achieved by the SSSC and its effects on the line voltage, line current, phase angle and real/reactive power. The designed device is simulated in a power system which is comprised of a three phase power source, a transmission line, line inductance and load. The system parameters such as line voltage, line current, reactive power Q and real power P transmissions are observed both when the SSSC is connected to and disconnected from the power system. The motivation for modeling a SSSC from a multi-pulse inverter is to enhance the voltage waveform of the device and this is observed in the total harmonic distortion (THD) analysis performed at the end of the paper. According to the results, the power flow and phase angle can be controlled successfully by the new device through voltage injection. Finally a THD analysis is performed to see the harmonics content. The effect on the quality of the line voltage and current is acceptable according to international standards.

사상체질별 건강수준에 따른 맥상, 안면, 피부, 음성의 물리량 도출을 위한 문헌고찰연구 (Literature Study for Categorizing Physical Properties of Face, Pulse, Skin and Voice Based on Health State of Sasang Constitutions)

  • 이재철;이유정;김재욱;김상길;강남식;김종열;김상혁
    • 동의생리병리학회지
    • /
    • 제25권4호
    • /
    • pp.755-758
    • /
    • 2011
  • Sasang Constitutional Medicine (SCM) suggests the concept of health condition which is owned of different properties by each Sasang Constitution. But SCM theory has concentrate to explaining different symptoms that distinguish health condition, not much concerned with practical methods like face features, pulse diagnosis, skin surface properties and voice features. Physical properties of practical diagnosis methods from literature finding have been researched. As a result, complexion and face moisture were described to be physical properties related to health State. In scope of pulse diagnosis, depth, rate, contour, width and pressure are related. Skin surfaces' elasticity, moisture, fraction properties were also suggested as factors of health State of Sasang Constitution. We assume that this study would contribute further studies for objectifying and quantifying diagnosis methods to evaluate health state grades of Sasang Constitution.

충격기류식 여과집진기의 내부 유동 시뮬레이션 해석을 통한 압력손실 예측 (Prediction of Pressure Drop Using the Internal Flow Simulation of Pulse Air Jet Bag Filters)

  • 장경민;정은상;서정민
    • 한국환경과학회지
    • /
    • 제29권5호
    • /
    • pp.457-468
    • /
    • 2020
  • With continuous industrial development, the types, and amount of particulate matter (PM) have been increasing. Since 2018, environmental standards regarding PM have become more stringent. Pulse air jet bag filters are suitable for PM under the 20 ㎛ and, can function regardless of size, concentration and type. Filtration velocity and shape are important factors in the operation and design of the pulse air jet bag filters however, few established studies support this theory. In this research, numerical simulations were conducted based on experimental values and, several methods were employed for minimizing the pressure drop. In the pilot system, as the inlet duct velocity was faster than 19 m/sec, flow was not distributed equally and, re-entrainment occurred due to the hopper directional vortex. The multi-inlet system decelerated the hopper directional vortex by 25 ~ 30%, thereby decreasing total pressure drop by 6.6 ~ 14.7%. The guide vane system blocked the hopper directional vortex, which resulted optimal vane angle of 53°. The total pressure of the guide vane system increased by 0.5 ~ 3% at 1.5 m/min conditions. However, the filtration pressure drop decreased by 4.8 ~ 12.3% in all conditions, thereby reducing the operating cost of filter bags.

펄스전원에 의한 수산화가스 발생기에 관한 연구 (A Study on Analysis of the Hydrogen-Oxygen Gas Generator Using Pulse Power Supply)

  • 이정민;강병희;목형수;최규하
    • 전력전자학회논문지
    • /
    • 제6권5호
    • /
    • pp.377-385
    • /
    • 2001
  • 물을 전기분해하여 얻은 일정 부피비를 갖는 수소와 산소 혼합가스를 수산화가스로 명명하며, 이를 역반응시켜서 열 에너지원으로 사용하고 있다. 수산화가스는 경제성, 안전성 및 환경친화적인 고유한 특성을 지니고 있어서 현재 가스용접기에 적용하고 있으며 여러 가지 응용분야에 적용할 수 있도록 연구 중에 있다. 본 논문에서는 수산화가스의 특성에 관하여 고찰하고 발생기용 전원에 대하여 소개하고 이 중에서 아직까지 적용되지 않은 펄스전원을 적용하여 여러 가지 운전주파수에서 비교분석 하였다.

  • PDF