• 제목/요약/키워드: Pulse studies

검색결과 474건 처리시간 0.021초

도깨비봉형 오존발생장치이 펄스커로나 방전에 의한 오존 발생 특성 (High Efficiency Ozone Generation Using a Pyramid-Project-Embossed Rod-to-Cylinder Electrode and a Pulse Corona Discharge)

  • 문재덕;이근택
    • 대한전기학회논문지
    • /
    • 제38권8호
    • /
    • pp.650-657
    • /
    • 1989
  • The conversion efficiency of an ozone generator can be significantly improved by modifying the discharge electrode of a helical strip line rod-to-cylinder type ozone generator to a pyramid-project-embossed rod, and by using a pulse corona discharge. Parametric studies have been carried out to obtain optimum values of peak pulse voltage, pulse forming capacitance, feeder cable and ozone generator capacitance, interelectrode spacing and corona tip density of ozone generator, and feed air flow rate and temperature. The generated ozone concentration was very dependent upon the value of pulse forming capacitance, feeder cable and ozone generator capacitance, and corona tip density. Maximum conversion efficiency was obtained with a pulse forming capacitance of about 500pF, 75pF matched feeder cable and ozone generator, and a corona tip density of 16mm. When operated at optimum values, ozone yield of 79, 99, 80 g/KWh for the different interelectrode type ozone generators tested were obtained, which are approximately 30% higher than that of an industrial ozone generator.

  • PDF

전극길이 및 펄스반복율에 대한 부하임피던스 특성변화에 관한 연구 (A Study on the Characteristics of Corona Critical Voltage on Increasing Load Impedance)

  • 정종한;송우정;전진안;이유수;김휘영;김희제
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계합동학술대회 논문집
    • /
    • pp.184-186
    • /
    • 2002
  • In this paper, we studies EMTP analysis and characteristics of critical voltage of pulse corona and load impedance on variable electrode length. To obtain a stable pulse voltage, we designed a compact pulse generator switched MOSFET and tested their characteristics by adjusting electrode length and pulse repetition. As a result, critical voltage of pulse corona and load impedance on increasing electrode length were decreased. These results indicate we can control critical voltage of pulse corona and suppress arc discharging between two electrodes.

  • PDF

『난경(難經)』의 진맥(診脈) 대법(大法)에 관한 고찰 (A Study on the Great Principle of Pulse Diagnosis in the 『Nanjing』)

  • 장우창;김윤아
    • 대한한의학원전학회지
    • /
    • 제33권4호
    • /
    • pp.83-105
    • /
    • 2020
  • Objectives : This paper aims to examine the system, principle, and fundamentals of the great principle of pulse diagnosis in the 『Nanjing』. Methods : The system, principle, and fundamentals of pulse diagnosis in the 『Nanjing』 were examined within the book's description framework and logical structure in light of its relationship to the 『Huangdineijing』. Previous studies that follow pulse diagnosis of 『Nanjing』 and 『Wangshuhe Maijue』 were referenced. Results & Conclusions : The structure of pulse diagnosis in the 『Nanjing』 is systematically organized under the principle of the three positions and nine indicators as the great principle to which the yinyang and five viscera pulse theories are included. The great principle of the three positions and nine indicators is consisted of a system that allows for a multiple and comprehensive interpretation wherein the theories of yinyang and five elements are interweaved within the pulse diagnosis system, which is comprised of a great principle and particular principles. The theory follows that of the three yin three yang theory of the five circuits and six qi, its principles manifesting as the three positions and nine indicators and integration of pulse and symptoms.

한국인 성인 남성의 체질별 맥상 특성에 관한 연구 (A Study on the Sasang Constitutional Differences in the Pulse Wave of Korean Healthy Adult Men)

  • 김호석;유현희;이시우
    • 한국한의학연구원논문집
    • /
    • 제13권2호통권20호
    • /
    • pp.71-74
    • /
    • 2007
  • Background : Sasang Constitutional Medicine (SCM) is the field of traditional Korean medicine that emphasize four constitutional types for diagnosis and treatment. Appearance, personalities and pathological characteristics are main factors of Sasang constitutional classification. Previous studies carried out by the pulse analyzer showed that the pulse wave can discriminate these types. In addition, It was reported that the pulse wave are affected by age and sexuality. In this study, we investigated the pulse wave characteristics related Sasang constitution types in control group regarding their age and sexuality. Subjects and Method : Two hudred and eighteen volunteers participated in this study: healthy men in $20{\sim}49$ years old. Participants were interviewed and examined to evaluate their health condition and Sasang constitution type. Then they were tested with pulse analyzer when they ere stabilized. The pulse at the radial artery just beside styloid process was measured, because this area is landmark for pulse diagnosis in oriental medicine. 3-D Mac pulse analyzer (Daeyo Medi Co. Ansan. Korea) was used in this study. We analyzed main features of pulse waves with the Sasang condtitution types by the SPSS for Windows (ver 12.0). Results : There was significant difference between Taeum and other types in contact pressure as weil as in coefficient of floating and sinking pulse. Conclusion : By analyzing pulse waves of healthy adult men. we found significant differences exist between Taeum and other types. These pulse differences may characterize Taeum type, and it will be helpful for the evaluation of Taeum type.

  • PDF

다종의 Pulse Oximeter에서 측정된 산소 분압도의 차이와 상호 비교 결과에 대한 보고 (COMPARATIVE STUDY OF SEVERAL TYPE PULSE OXIMETER AND OXYGEN SATURATION EXTRACTED FROM THEM)

  • 유승훈;김응학;권순원;김종수
    • 대한소아치과학회지
    • /
    • 제27권4호
    • /
    • pp.494-498
    • /
    • 2000
  • 진정요법하의 치과진료에서 환자의 상태를 지속적으로 감시하는 것은 매우 중요하다. 여러 방법 중 가장 널리 사용되는 것 중 Pulse Oximeter가 있다. Pulse Oximeter는 비침습적 방법으로 계속해서 동맥혈액의 산소포화도를 측정할 수 있도록 고안된 장치로서 기기에 나타나는 산소포화도$(SpO_2)$는 실제로 측정한 동맥혈액의 산소포화도$(SaO_2)$와 거의 일치하는 것으로 알려져 있다. 본 진료실에 있는 세종류의 Pulse Oximeter를 이용하여 한 환자에게 동시에 두 개의 기기를 적용하였을 경우, 산출값을 상호 비교한 결과, 짧은(3회) 맥박수를 평균하는 기기가 낮은값이 나왔으며, 다른 두개의 Pulse Oximeter와 유의한 차이가 있는 것으로 밝혀졌다. 짧은 맥박수를 평균하는 기기는 반응이 빠르나, 산소포화도의 값이 작게 산출되고, 외부의 신호에 더욱 민감하여, 오류가 존재할 가능성 또한 높다. 기기의 특성을 알아, 술자는 적절한 기기를 선택하는 것이 중요하다.

  • PDF

중풍환자의 변증에 따른 맥상의 분포 (Study on the Pulse Diagnosis for Pattern Identifications in Stroke Patients)

  • 이정섭;강병갑;고미미;김보영;김정철;이인;김윤식;조기호;최선미;방옥선
    • 동의생리병리학회지
    • /
    • 제22권6호
    • /
    • pp.1378-1382
    • /
    • 2008
  • This study is aim to evaluate pulse diagnosis as indicators for classification of the pattern identifications in stroke patients. To get the clinical information, we recruited the onset 1 month stroke patients through the multicenter network which consists of 13 oriental hospitals. The clinical informations about three pairs of pulse wave form and levels of their significancy based on the case report form (CRF) were collected and their distribution in each pattern identification were analyzed. The results are as follows Fire-Heat group shows high portions of floating pulse, rapid pulse and solid pulse. Qi Defficiency group has a greater portion of deep pulse, slow pulse, deficient pulse. The well-defined character of Phlegm-Retained Fluid, Yin Defficiency, Static Blood groups cannot be explained by pulse wave form. These results show a rough relationship between the pulse diagnosis and pattern identifications of stroke therefore, further studies are required to determine the pulse diagnosis as significant indicators of stroke pattern identification.

중풍환자의 변증에 사용되는 맥진 지표에 관한 연구 (Study on the Basic Pulse Indicators for Pattern Identifications in Stroke)

  • 이정섭;고미미;강병갑;김소연;김정철;오달석;이인;김윤식;방옥선
    • 동의생리병리학회지
    • /
    • 제23권5호
    • /
    • pp.964-968
    • /
    • 2009
  • The purpose of this study is to select the major pulse indicators and evaluate their significance in discriminating the subtypes of Pattern Identifications (PI) from stroke patients. Decision tree analysis was carried out using clinical data collected from 835 stroke patients with the same subtypes diagnosed identically by two experts with more than 3 year clinical experiences. Among the 10 pulse indicators, 6 major pulse indicators (slow, rapid, strong, weak, slippery, and fine pulse) were selected by decision tree analysis. The accumulated distributions of six pulse indicators in each PI showed that strong was major pulse indicator in Fire-Heat pattern, slippery in Dampness Phlegm pattern, weak in Qi Deficiency pattern. But there were two major combinations in Yin deficiency pattern, weak or fine with rapid pulse and weak or fine without rapid pulse. Therefore, it is suggested that 6 pulse indicators can be used for discrimination of PI in stroke patients, though the combination studies between these pulse indicators and the other PI indicators are left for further study.

토노메트리 방식 맥파 측정의 가압 각도에 따른 변동성 평가 (Variation Factor Assessment of Radial Artery Pulse by the Tonometry Angle of the Pulse Pressure Sensor)

  • 정창진;조정희;전민호;전영주;김영민
    • 센서학회지
    • /
    • 제25권2호
    • /
    • pp.138-142
    • /
    • 2016
  • A pulse measurement by tonometry provides useful information for diagnosis, including not only blood pressure and heart rate but also parameters for estimating a condition of the cardiovascular system. Currently, various pulse measurement devices based on the tonometry have been developed. A reliability of these devices is determined by a positioning technic between the sensor and the blood vessel and a controlling technique of the pressurization level. An angle of the sensor for the pulse measurement seems to be highly related with a measured signal, however, the objective studies for this issue have been not published. In this paper, the variation of the pulse signals by tonometry direction was experimentally assessed according to the angle of the sensor. In order for guaranteeing the repeatability of the experiment, we used a pulse generator device, which can generate human pulse signal by using silicon tube and fluid pump, and developed a structure for precise adjustment of the angle and the pressurization level of the sensor. The angle of the sensor was acquired by an inclinometer, which was attached at the opposite side of the sensor. As results, a coefficient of variation (CV) of a maximum amplitude (MA) of the pulse wave was largely increased over the angle range of $-9{\sim}9^{\circ}$. Furthermore, the changes of the pulse shape showed different aspects according to the sign of the angle tilted along the blood vessel. It is expected that the results of this study can be helpful for developing more precise pulse measurement devices based on the tonometry and applying in clinic.

비정격(脾正格) 자침이 정상 성인 맥파(脈波) 변화에 미치는 영향 (The Effects of Sa-Am Spleen-tonifying Acupuncture on Radial Pulse in Healthy Human Subjects)

  • 윤광식;이현
    • Journal of Acupuncture Research
    • /
    • 제30권4호
    • /
    • pp.1-14
    • /
    • 2013
  • Objectives : The purpose of this study is to investigate the effects of Sa-Am spleen-tonifying acupuncture on radial pulse in healthy human subjects. Methods : Forty healthy human subjects participated in this study, divided into acupuncture group and control group. Radial pulse was measured by 3 dimensional pulse imaging system(DMP-3000) before, right after, 30 minutes after and 60 minutes after acupuncture in the acupuncture group. The subjects in the control group didn't received acupuncture but took a rest and then the radial pulse was measured at the same time points as the acupuncture group. The parameters were analyzed by gender, measuring location, and measuring time point. However the time related parameters exceptionally were analyzed without distinction of measuring location. Results : 1. T, variance of period, T2/T, T4/T, (T-T4)/T, T4/(T-T4), and W significantly changed after acupuncture. 2. Pressure, amplitude of H1, amplitude of H2, Amplitude of H4 and pulse energy significantly changed after acupuncture. 3. Pulse area, systolic pulse area and diastolic pulse area significantly changed after acupuncture. 4. Elasticity, AIx and AIx/HR significantly changed after acupuncture. Conclusions : The effect of Sa-Am spleen-tonifying acupuncture in healthy human may be observed on time, amplitude, pulse area and augmentation index. Further studies on the effects of Sa-Am acupuncture using radial pulse are needed.

체계 수준 HEMP 내성 시험을 위한 시험파형 계측 기법 연구 (A Study on the Measurement Method of Test Waveform for System-level HEMP Immunity Test)

  • 여세동
    • 한국군사과학기술학회지
    • /
    • 제22권2호
    • /
    • pp.233-240
    • /
    • 2019
  • High-altitude ElectroMagnetic Pulse(HEMP) is a high-power electromagnetic pulse caused by nuclear explosions at altitudes above 30 km. This pulse can cause serious damage to the electrical/electronic device. Therefore, there are a lot of studies on the effects of HEMP in the literature. When conducting studies on the effects of HEMP, it is essential to measure the simulated HEMP. Depending on the need for measurement, this paper focuses on the HEMP measurement method. This paper proposes a measurement method using frequency domain compensation to extract the correct waveform and solves the offset problem more efficiently than the conventional methods. The proposed method is verified by experiment using HEMP simulator and measurement system in ADD.