• Title/Summary/Keyword: Pulse plant

Search Result 116, Processing Time 0.03 seconds

Effect of Additional Pulse to Remove the Sulfate Film on the Charging Capacity in the Industrial Lead-Acid Battery (극판 피막 분해용 펄스파가 산업용 연축전지의 충전용량에 미치는 영향)

  • Choi, Kwang-Gyun;Yoo, Ho-seon
    • Plant Journal
    • /
    • v.16 no.4
    • /
    • pp.40-44
    • /
    • 2020
  • In this study, after supplying a pulse wave to the 2 V Industrial Lead-Acid Battery electrode plate and repeating the charging and discharging, the discharging time per voltage was analyzed. According to the result of experiment, while the lead-acid Battery that a pulse wave is not supplied decreased about 18 % of discharging capacity than the beginning, the lead-acid Battery that a pulse wave is supplied decreased a little amount much lower than 18 %, of discharging capacity and recorded the 0.56 % decrease, at a minimum, from discharging capacity at the 20 kHz frequency. This means that the sulfate on electrode plate is detached and the positive and negative charge transfer is highly activated at the 20 kHz frequency

Determination of Traces of Selenium in Plant Materials by Cathodic Stripping Voltammetry (Cathodic Stripping Voltammetry법에 의한 식물체 중 극미량 셀렌의 분석)

  • 문동철;홍성화;박만기;김중기;이광우
    • YAKHAK HOEJI
    • /
    • v.29 no.3
    • /
    • pp.144-151
    • /
    • 1985
  • Cathodic stripping voltammetric determination of traces of selenium in plant samples was studied. Stripping peak of selenium (IV) from Cu-Se intermettalic deposit in acidic media containing copper (II) ion is specific, highly sensitive and well defined, is successfully used for the quantitative determination of selenuin down to the level of 1ng/ml. Sample is burnt in a calorimeter bomb under the oxygen pressure of 40atm. and the selenium is absorbed in 0.1M NaOH. After the solution is filtrated, concentrated and acidified with HCl, then passed through a column of cation exchange resin in the $H^{+}$ form(Dowex 50X-8). The column eluate is analyzed for selenium by differential pulse cathodic stripping voltammetric method. Analytical results of selenium for NBS SMR is well agreement with the certified values. Results are given for a series of plant materials.

  • PDF

Speed Control of Induction Motor Using Anti-windup Integral-Proportional Controller (반포화 적분-비례제어기를 이용한 유도전동기의 속도제어)

  • 정재호
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.215-218
    • /
    • 2000
  • The windup phenomenon appears and degrades control performance when a controller with integrating action is used and the plant input is limited. An anti-windup integral -proportional(IP) controller is proposed for the variable-speed motor drives and it is experimentally applied to the speed control of a vector-controlled induction motor driven by a pulse width modulated (PWM) voltage source inverter(VSI). Although the operating conditions like motor load and speed command is changed under the limited plant input it is experimentally verified that the speed response has much improved performance such as no overshoot and fast settling time and the maximum plant input is also effectively utilized.

  • PDF

Anti-windup Integral-Proportional Controller for Variable-Speed Motor Drives

  • Park, Jong-Gyu;Chung, Jae-ho;Shin, Hwi-Beom
    • Journal of Power Electronics
    • /
    • v.2 no.2
    • /
    • pp.130-138
    • /
    • 2002
  • The windup phenomenon appears and degrades control performance when a controller with integrating action is used and plant input is limited. An anti-windup integal-proportional(IP) controller is proposed for the variable-speed moter drives and it is experimentally applied to the speed control of a vector-controlled induction moter driven by a pulse width modulated (PWM) voltage source inverter (VSI). The consistency range of the IP controller is firstly derived and the intergal state is controlled to salisfy always the consistency range according to whether the the controller output is saturated or not. Although the operating condition like moter load or speed command is changed under the limited plant input, It is expermentally verified that the speed response has much improved performance, such as no overshoot and fast settling time, and the maximmum plant input is also effectively utilized.

A Pulser System with Parallel Spark Gaps at High Repetition Rate

  • Lee, Byung-Joon;Nam, Jong-Woo;Rahaman, Hasibur;Nam, Sang-Hoon;Ahn, Jae-Woon;Jo, Seung-Whan;Kwon, Hae-Ok
    • Journal of IKEEE
    • /
    • v.15 no.4
    • /
    • pp.305-312
    • /
    • 2011
  • A primary interest of this work is to develop an efficient and powerful repetitive pulser system for the application of ultra wide band generation. The important component of the pulser system is a small-sized coaxial type spark gap with planar electrodes filled with SF6 gas. A repetitive switching action by the coaxial spark gap generates two consecutive pulses in less than a microsecond with rise times of a few hundred picoseconds (ps). A set of several parameters for the repetitive switching of the spark gap is required to be optimized in charging and discharging systems of the pulser. The parameters in the charging system include a circuit scheme, circuit elements, the applied voltage and current ratings from power supplies. The parameters in the discharging system include the spark gap geometry, electrode gap distance, gas type, gas pressure and the load. The characteristics of the spark gap discharge, such as breakdown voltage, output current pulse and recovery rate are too dynamic to control by switching continuously at a high pulse repetition rate (PRR). This leads to a low charging efficiency of the spark gap system. The breakthrough of the low charging efficiency is achieved by a parallel operation of two spark gaps system. The operational behavior of the two spark gaps system is presented in this paper. The work has focused on improvement of the charging efficiency by scaling the PRR of each spark gap in the two spark gaps system.

A Study on the Linear Pulse Motor Driving Control-Rod for Korean Nucle Power Plant (한국형 원자로의 제어봉 구동용 선형전동기 설계에 관한 연구)

  • Chang, K.C.;Ha, K.D.;Kang, D.H.;Huh, H.;Kim, J.H.;Kim, J.I.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.46-48
    • /
    • 1998
  • This paper introduces the design method of a variable reluctace liner pulse motor to be analysed by a 3-dimensional problem in the 2-dimension. And it shows the thrust force density with respect to the ratio of the slot width to the teeth width, the height of mover and the height of tooth.

  • PDF

Technical Development of Flue Gas Control at Commercial Plant Using the Non-thermal Plasma Process (저온 플라즈마 공정을 이용한 상용설비의 배연가스 처리 기술개발)

  • Yoo, J.S.;Paek, M.S.;Kim, T.H.;Kim, J.I.;Kim, Y.S.;Choi, S.H.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.939-944
    • /
    • 2001
  • For the application of simultaneous $DeSO_{2}\;&\;DeNO_{x}$ equipment using non-thermal plasma process to the industrial and power plants, the many types of plasma device and process were studied. The e-beam and pulsed plasma corona discharge process are outstanding for the study to apply commercial large-scale plant from among these. In this paper, non-thermal plasma of technical trends and the characteristics of system developed by Doosan heavy industries & construction Co., Ltd. are explained. We have researched pulsed plasma corona discharge process since 1994. At the basis of reasonable results for the pilot plant, we constructed the demonstration plant at a domestic coal-fired power plant in 1999, as the previous step for commercial use. In near future, enough information about designs and costs of commercial-size system will be obtained.

  • PDF

Modeling and Analysis of Zero Voltage Switching PWM Half Bridge DC/DC Converter (영전압 스위칭 PWM 하프 브릿지 컨버터의 모델링 및 분석)

  • 강정일;정영석;노정욱;윤명중
    • Proceedings of the KIPE Conference
    • /
    • 1997.07a
    • /
    • pp.101-110
    • /
    • 1997
  • The circuit effects due to the transformer primary side series equivalent inductance in the Zero Voltage Switching Pulse Width Modulated Half Bridge DC/DC Converter and its impact on the effective duty are analyzed. The steady state equations and the small signal model of the converter are derived incorporating the effects of the complementary control and the utilization of transformer primary side series equivalent inductance. The open plant dynamics are analyzed on the basis of the model derived. The model predictions are confirmed by experimental measurements.

  • PDF

Photosynthetic Characteristics of Polyvinylalcohol-Immobilized Spinach Chloroplasts (Polyvinylalcohol에 고정화한 시금치 엽록체의 광합성특성에 대한 연구)

  • 박인호
    • Journal of Plant Biology
    • /
    • v.34 no.3
    • /
    • pp.215-221
    • /
    • 1991
  • Photoxynthetic properties of polyvinylalcohol (PVA)-immobilized chloroplast especially regarded to stability of photosynthetic electron transport and the fluorescence induction pattern were studied. When isolated spinach chloroplasts were immobilized with PVA, it showed good preservation of photosynthetic electron transport activity, especially PS II activity, during storage at -15$^{\circ}C$, 4$^{\circ}C$ and 2$0^{\circ}C$. And immobilized chloroplasts revealed similar thermostability of whole chain electron transport to free chloroplsts. And the absorption peak of red band of chloroplasts showed the blue-shift of 2-4 nm after immobilization. Fv/Fm ratio of chlorophyll fluorescence slightly decreased after immobilization. White light pulse after continuous light do not induced the additional fluorescence rise. This means chlorophyll fluorescence at room temperature reached to Fmax under continuous light in the immobilized chloroplasts. It seems that PVA may be a good candidate for immobilization matrix for the preservation of photosynthetic function of thylakoids and for the continuous use of chloroplast membranes of higher plants for solar energy storage and conversion.

  • PDF

Modeling and Analysis of the Dynamic Characteristics of Pipe Supporting Hydraulic Snubber in Electric Power Plant (발전소 배관지지용 유압완충기의 동특성 모델링 해석)

  • 이재천;황태영
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.87-91
    • /
    • 1997
  • This paper presents the modeling and analysis of dynamic characteristics of hydraulic snubber in electric power plant. The nonlinear state equations of 9th order to describe the dynamics of the snubber was established by Sirnulink. The simulation results show that the hydraulic snubber reacts as like the conventional shock absolvers to the high pulse shock load. The snubber also shows the peculiar characteristics to the small step load, which are temporary locking displacements of control valves and same steady-state pressures of all internal chambers in the snubber.

  • PDF