• 제목/요약/키워드: Pulse period

검색결과 569건 처리시간 0.022초

Evaluation of pulse effect on frequency content of ground motions and definition of a new characteristic period

  • Yaghmaei-Sabegh, Saman
    • Earthquakes and Structures
    • /
    • 제20권4호
    • /
    • pp.457-471
    • /
    • 2021
  • This study aims at providing a simple and effective methodology to define a meaningful characteristic period for special class of earthquake records named "pulse-like ground motions". In the proposed method, continuous wavelet transform is employed to extract the large pulse of ground motions. Then, Fourier amplitude spectra obtained from the original ground motion and the residual motion is simply compared. This comparison permits to define a threshold pulse-period (Tp∗) as the threshold period above which the pulse component has negligible contributions to the Fourier amplitude spectrum. The effect of pulse on frequency content of motions was discussed on the light of this definition. The advantage and superior features of the new definition were related to the inelastic displacement ratio (IDR) for single-degree-of-freedom systems with period equal to one half of the threshold period. Analyses performed for the proposed period at three ductility levels u=2,4,6 were compared with the results obtained at half of pulse period derived from wavelet analysis, peak-point method and the peak of product of the velocity and the displacement response spectra (Sv x Sd). According to the results, pulse effects on inelastic displacement ratio seem to be more important when $\frac{T_p^*}{T}=2$ (T is the fundamental vibration period of system). The results showed that utilizing of the proposed definition could facilitate an enhanced understanding of pulse-like records features.

A STUDY ON PULSE RATE SYSTEM

  • Kim, H. K.;S. C. Han;K. K. Min;W. Huh
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.535-537
    • /
    • 1998
  • In this paper, we devised a pulse rate detection system to provide basic clinical index of cold-hot diagnosis of oriental medicine. The system consists of pulse signal detection, respiration signal detection, electrocardiograph detection, A/D conversion and computer system parts. We define a pulse rate by a pulse count to the respiration period inspiration pulse rate by a pulse count to the inspiration period, and expiration pulse rate by a pulse count to the expiration period. The clinical experiments for normal Person to evaluate the pulse rate detection system show the pulse/respiration ratio of 4.30${\pm}$1.03, the pulse/inspiration ratio of 1.60${\pm}$0.32, the pulse/expiration ratio of 2.37${\pm}$0.75.

  • PDF

소아맥진(小兒脈診)의 특성(特性)에 대한 소고(小考) (A study on The Characteristic of Traditional Pediatric Pulse Diagnosis)

  • 백유상
    • 대한한의학원전학회지
    • /
    • 제27권1호
    • /
    • pp.111-122
    • /
    • 2014
  • Objective : The region, observation period, figuration of pulse, pulse frequency, process of diagnosis and related diagnostic methods in traditional pediatric pulse diagnosis were studied in this article. Method : The articles related to traditional pediatric pulse diagnosis in Traditional medical classics, and analysis to the characteristics of it was done, then lastly, the principle of pulse manifestation and the meaning of application to modern times were considered. Result & Conclusion : It is difficult to catch the figuration of pediatric pulse because of dynamic change of body conditions, fast heartbeat and narrow region of pulse. Therefore, the pulse diagnosis appropriated for children have been developed and combined with the special diagnosis methods, for example, palpation of forehead and observation of index finger. The traditional pediatric pulse diagnosis is done with just one finger palpation in the period of 3 to 5 years old to identify the speed, length, size and height of pulse. The standard average of pulse frequency is 7~8 par breath in the period of 3 to 5 years old according to traditional medical classic.

표시기간 중첩 프라이밍 구동기술에 의한 플라즈마 디스플레이 패널의 고속구동특성 (High-Speed Characteristics of Plasma Display Panel using Priming Overlapping with Display Drive Method)

  • 염정덕
    • 전기학회논문지
    • /
    • 제56권11호
    • /
    • pp.2004-2009
    • /
    • 2007
  • A new high-speed drive method for the plasma display panel is proposed. In this method, the address period is inserted for the rest period of the sustain pulses and the priming pulse is applied on the entire panel at the same time overlapping with the sustain period. The ramp shaped priming pulse can be made with a simple drive circuit in this technology and the stable sustain discharge can be induced even by a narrow scan pulse in help of the space charge generated from the address discharge. From the experiments, it is ascertained that the priming pulse hardly influences the sustain discharge. Moreover, the voltage margin of the sustain discharge is almost constant though that of the address discharge broadens with narrowing the scan pulse width. And, if the time interval between the scan pulse and the sustain pulse is within $6{\mu}s$, the voltage margin of the address and the sustain discharges are unaffected though the applied position of the scan pulse is changed. High-speed driving with the address pulse of $0.7{\mu}s$ width was achieved and the address voltage margin of 20V and the sustain voltage margin of 10V were obtained.

웨이브렛 변환을 이용한 맥파의 인식에 관한 연구 (A Study on the Recognition of Human Pulse Using Wavelet Transform)

  • 길세기;김낙환;박승환;민홍기;흥승홍
    • 융합신호처리학회 학술대회논문집
    • /
    • 한국신호처리시스템학회 2000년도 하계종합학술대회논문집
    • /
    • pp.269-272
    • /
    • 2000
  • It is need to develop and apply a human pulse diagnosis system providing a quantitative and automatic analysis in the the oriental medicine. In order to analyze quantitatively the characteristic of pulsation, each of points had to be recognized accurately notifying the existence and the position of feature point in the wave form. And getting the period of human pulse. Thus, in this paper, it is proposed the preprocessing method of human pulse and the detection method of period by Wavelet Transformation. The human pulse is seprated from each band through Wavelet Transformation and feature points can be recognized through over the fact, and then the parameter of proposed Mac-Jin parameter is measured. Commonly, Human pulse signal has often various noises which are baseline drift, high frequency noise and so on. So it is significant to remove that noises. Thus, in this paper, the one period of human pulse is deciede and the feature points are detected after doing the preprocessing by wavelet transformation. As a result, it could be confirmed that this method is effective as a real program for the auto-diagnosis of human pulse.

  • PDF

HARD X-RAY PULSATIONS IN GX 1+4

  • AGRAWAL P. C.;PAUL B.;RAO A. R.;CHANDA R. K. MAN
    • 천문학회지
    • /
    • 제29권spc1호
    • /
    • pp.219-221
    • /
    • 1996
  • The x-ray pulsar GX 1+4 was observed by us in four balloon- borne experiments carried out from Hyderabad, India during 1991-1995 period with a hard x-ray telescope. The x-ray telescope consists of two collimated large area xenon-filled proportional counters with an effective area of $2400 cm^2$, a field of view of $5^{\circ}{\times}5^{\circ}$ and sensitive in the energy band of 20 - 100 keV. The pulsar was detected in bright state in two of the four experiments and x-ray pulsations with 120 second period were detected clearly. Pulsation period, rate of change of period with time, pulse fraction, pulse profile and energy spectra of the source were determined from these studies. During March 1995 observation, the x-ray pulse of GX 1+4 was found to be double-peaked compared to a single-peak pulse profile detected in December 1993. Details of these results are presented and their interpretation discussed in terms of the current accretion models of x-ray binaries.

  • PDF

임산(臨産) 이경맥(離經脈)에 대한 연구 - 맥리(脈理)와 임상활용을 중심으로 - (Research on the Imminent Labor Pulse - A Focus on Pulse Theory and Clinical Practicality -)

  • 류정아;백상룡;정창현
    • 대한한의학원전학회지
    • /
    • 제26권1호
    • /
    • pp.131-150
    • /
    • 2013
  • Subject : The Imminent Labor Pulse(臨産 離經脈, extra-meridian pulse approaching labor) is one of many practical clinical knowledges, unique to Traditional Korean(Eastern) Medicine. Objective : This research explores the origin and change of perception on the subject throughout history, with objective to sort out practical knowledge applicable in the clinic of today. Also, it draws clinical meaning of pulse diagnosis according to the physiological theories, and suggests directions for future clinical researches. Method : First, the Imminent Labor Pulse was examined based on major publications such as the "Nanjing", "Maijing" and theories of major doctors. Second, this previous study was examined through clinical observation research. Third, further research was carried out on pulse theory according to the Traditional Medical theories. Fourth, their clinical practicality and points of further research were sorted out. These points need to be examined through additional clinical research. Conclusion : The following conclusions could be drawn from study of the Imminent Labor Pulse. From the Imminent Labor Pulse which indicated the beginning of the first period of labor in the "Maijing", it developed into trying to grasp the beginning of the second period of labor which is the actual time of labor, through "Zhubingyuanhoulun" and "Shizaizhifang". By Xueji, another pulse that could be felt on the middle finger of the mother had been discovered. The middle finger is where the Pericardium Meridian flows. The child's connection to the uterus becomes disconnected on the first period, but that with the Pericardium meridian which provides blood meridian to the Taichongmai of the child continues throughout labor until the umbilicus chord is cut. Therefore, this middle finger pulse could serve as showing the heart condition of the mother and child during labor. The time of its appearance and disappearance, and their correlation with the child's heartbeat need to be clinically examined.

갑기위남정(甲己爲南政) 여위북정설(餘爲北政說)에 관한 연구(硏究) (A Study on the Theory of JiaJi Years(甲己年) as a period of South Politics(南政) and the Rest Eight Years as a period of North Politics(北政))

  • 윤창열
    • 대한한의학원전학회지
    • /
    • 제29권1호
    • /
    • pp.65-76
    • /
    • 2016
  • Objectives : Generally, pulsation is influenced by climate change in the realms of nature. However, there is a theory explaining a phenomenon in which the pulse gets weaker and even absent for no reason, without affected by diseases; this is the Theory of South and North Politics with which medical practitioners need to be familiar when taking the pulse of patients. Methods : The researcher considered all the previous annotations and the original text of SuWen (素問) ZhiZhenYaoDaLun(至眞要大論). Results : In Five Elements' Evolutions, JiaJi(甲己) becomes Tu(土), which turns itself into the king, an honorable duty. JiaJi is a period of South Politics because it looks south to give an order while the rest eight years is a period of North Politics because they are headed north to receive an order. Conclusions : Since South Politics years look south as a standard, Cun(寸) is located at the south and Chi(尺) is at the north. Controlling the Heaven energy(司天) is located at the south and Effecting the Earth energy(在泉) is at the north. Therefore, if Sanyin is Controlling the Heaven energy(三陰司天), the Cun pulse is absent; if Shaoyin is Controlling the Heaven energy(少陰司天), Cun pulses on both wrists are not felt; if Jueyin is Controlling the Heaven energy(厥陰司天), the Cun pulse on the right wrist disappears; if Taiyin is Controlling the Heaven energy(太陰司天), the Cun pulse on the left wrist is not felt. In the case of Chi, if Sanyin is Effecting the Earth energy(三陰在泉), the Chi pulse is absent; if Shaoyin is Effecting the Earth energy(少陰在泉), Chi pulses on both wrists are not felt; if Jueyin is Effecting the Earth energy(厥陰在泉), the Chi pulse on the right wrist disappears; if Taiyin is Effecting the Earth energy(太陰在泉), the Chi pulse on the left wrist is not felt. North Politics years appears conversely as compared with South Politics years.

새로운 맥파 인식 알고리즘을 적용한 자동 맥파 시스템에 관한 연구 (A Study on the Auto-diagnosis Plethysmograph by Novel Algorithm for Radial Pulse Detection)

  • 박승환;홍승홍
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권2호
    • /
    • pp.241-246
    • /
    • 1996
  • This paper describes a new system that detects radial pulse wave and allows the diagnosis of malfunctions of cardiovascular system by analyzing the waveforms with the newly proposed algorithm. The system consists of a sensor part and a data processing part within which a new detection algorithm is incorporated In acquiring radial pulse signal noninvasively, the sensor used in this system is a new combinational fiber-optic sensor which has a detecting Part and a transmitting Part. Also, In order to analyze the characteristics of pulsation quantitatively, the algorithm proposed in this paper is a method that runs in parallel with both the data of ECG and differential pulse simultaneously. these concepts are based upon the idea that thfee Q points of ECG give obious discrimination of one entire period of pulse in any abnormal cases, and newly defined feature lines at the differential counterpart can be used to recogrlize sDme significant points in one period of pulses.

  • PDF

스캔주기 유효성 판별에 의한 레이더 식별 (Radar identification by scan period validation)

  • 김관태
    • 융합정보논문지
    • /
    • 제11권11호
    • /
    • pp.17-22
    • /
    • 2021
  • 전자전에서 레이더 신호 해석은 수신한 레이더 신호에서 추출한 신호제원(방향, 주파수, 펄스반복주기, 펄스 폭, 스캔주기)으로 레이더 종류를 식별하는 기술이다. 그러나 신형 레이더, 위협환경이 고도화되면서 레이더 종류를 식별하는 과정에서 레이더 식별 모호성(Ambiguity)가 발생한다. 본 논문에서는 기존 방법의 문제점을 분석하고 새로운 방법을 제안한다. 이 기술은 레이더 스캔 주기의 펄스 도착시간 차이와 스캔주기 판별 최소 수집 개수로 스캔주기 유효성을 판별한다. 실험에 의하여 입력된 신호세기의 RMS((Root Mean Square)와 무관하게 스캔 주기 결과를 도출하는 것을 입증했다.