Geoacoustic Model of Coastal Bottom Strata at Jeongdongjin in the Korean Continental Margin of the East Sea (동해 한국대륙주변부 정동진 연안 지층의 지음향 모델)

  • Ryang, Woo-Hun;Kim, Seong-Pil;Kim, Dae-Choul;Hahn, Jooyoung
    • Journal of the Korean earth science society
    • /
    • v.37 no.4
    • /
    • pp.200-210
    • /
    • 2016
  • Geoacoustic modeling is used to predict sound transmission through submarine bottom layers of sedimentary strata and acoustic basement. This study reconstructed four geoacoustic models for sediments of 50 m thick at the Jeongdongjin area in the western continental margin of the East Sea. Bottom models were based on the data of the highresolution air-gun seismic and subbottom profiles (SBP) with sediment cores. P-wave speed was measured by the pulse transmission technique, and the resonance frequency of piezoelectric transducers was maintained at 1MHz. Measurements of 42 P-wave speeds and 41 attenuations were fulfilled in three core sediments. For actual modeling, the P-wave speeds of the models were compensated to in situ depth below the sea floor using the Hamilton method. These geoacoustic models of coastal bottom strata will be used for geoacoustic and underwater acoustic experiments reflecting vertical and lateral variability of geoacoustic properties in the Jeongdongjin area of the East Sea.

A Study on the Neutral Point Potential Variation under Open-Circuit Fault of Three-Level NPC Inverter (3레벨 NPC 인버터 개방성 고장 시 중성점 전압변동에 관한 연구)

  • Park, Jong-Je;Park, Byoung-Gun;Ha, Dong-Hyun;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.333-342
    • /
    • 2009
  • Three-level Diode Clamped Multilevel Inverter, generally known as Neutral-Point-Clamped (NPC) Inverter, has an inherent problem causing Neutral Point (NP) potential variation. Until now, in many literatures NP potential problem has been investigated and lots of solutions have also been proposed. However, under fault and fault tolerant control, distinctive feature for NP potential variation problem was rarely published from the standpoint of reliability. In this paper, NP potential is analytically investigated both normal and faulty conditions under carrier based PWM. Subsequently, relation between fault detection time and size of capacitor is analyzed. This information is explored by simulation and experiment results, which contribute to enhance the reliability of inverter system.

An Optical Fiber Perimeter Guard System Using OTDRs (OTDR을 이용한 광섬유 외곽경비시스템에 관한 연구)

  • Chang, Jin-Hyeon;Lee, Yong-Cheol;Shin, Dong-Ho;Oh, Sang-Gun;Lee, Jong-Youn;Jung, Jin-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.12B
    • /
    • pp.1236-1243
    • /
    • 2010
  • The perimeter defense system was created and its characteristics were evaluated. It was designed to utilize the fiber sensing device, namely OTDR(Optical Time Domain Reflectometer) which has been used for the maintenance of the optical communication network. An OTDR was constituted by a pulse laser with the nature of 1310nm, +15dBm for the observation of 400 meter optical fence. The high-speed 32-bit processor(S3C2440) has applied to MPU(Main Processor Unit) which helps to improve the performance of OTDR algorithms. Consequently, the maximum error was 0.84 meter on the performance test of the 10km monitoring and the pass criteria of ${\pm}1m$ satisfied in all the sections. The alarm delay time was under 3 sec after detecting the disorder. For the case of secondary trespassing after primary trespassing, the optical switch was installed in OTDR to monitor the secondary trespassing and to measure the multi-point detection. Therefore, this paper shows that the detections of secondary trespassing and multi-point is possible by means of optical switch.

Acute Respiratory Failure due to Fatal Acute Copper Sulfate Poisoning : A Case Report (급성 호흡부전으로 사망한 황산구리 중독 1례)

  • Kim, Gun Bea
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.13 no.1
    • /
    • pp.36-39
    • /
    • 2015
  • Copper sulfate is a copper compound used widely in the chemical and agriculture industries. Most intoxication occurs in developing countries of Southeast Asia particularly India, but rarely occurs in Western countries. The early symptoms of intoxication are nausea, vomiting, diarrhea, and abdominal cramps, and the most distinguishable clue is bluish vomiting. The clinical signs of copper sulfate intoxication can vary according to the amount ingested. A 75-year old man came to our emergency room because he had taken approximately 250 ml copper sulfate per oral. His Glasgow Coma Scale (GCS) score was 14 and vital signs were blood pressure 173/111 mmHg, pulse rate 24 bpm, respiration rate 24 bpm, and body temperature $36.1^{\circ}$ .... Arterial blood gas analysis (ABGa) showed mild hypoxemia and just improved after 2 L/min oxygen supply via nasal cannula. Other laboratory tests and chest CT scan showed no clinical significance. Three hours later, the patient's mental status showed sudden deterioration (GCS 11), and ABGa showed hypercarbia. He was arrested and his spontaneous circulation returned after 8 minutes CPR. However, 22 minutes later, he was arrested again and returned after 3 minutes CPR. The family did not want additional resuscitation, so that he died 5 hours after ED visit. In my knowledge, early deaths are the consequence of shock, while late mortality is related to renal and hepatic failure. However, as this case shows, consideration of early definite airway preservation is reasonable in a case of supposed copper sulfate intoxication, because the patients can show rapid deterioration even when serious clinical manifestation are not presented initially.

  • PDF

PECS Process for Fabrication of Nanostructured Fe-Co Softmagnetic Alloy (나노구조 Fe-Co 연자성 합금의 제조를 위한 PECS 공정 연구)

  • Hong, Sung-Soo;Kim, Dae-Gun;Kim, Young-Do
    • Korean Journal of Materials Research
    • /
    • v.11 no.5
    • /
    • pp.378-384
    • /
    • 2001
  • In this study, nanostructured Fe-Ce powder with grain size of 10nm was produced by MA (mechanical alloying) process and was consolidated by PECS (pulse electric current sintering) process for the fabrication of bulk nanostructured Fe-Co softmagnetic alloy. PECS process was performed at 700, 800, 900 and $^1000{\circ}C$ with holding time ranging from 0 to 15min. The effectiveness of PECS Process to Produce nanostructured bulk specimens was estimated. The optimal PECS process condition for nanostructured Fe-Co powders was found through observing the change of relative density and microstructure with sintering temperature and holding time. The magnetic properties of the sintered specimens were evaluated through the measurement of coercivity and saturation magnetization.

  • PDF

A Wide Input Range, 95.4% Power Efficiency DC-DC Buck Converter with a Phase-Locked Loop in 0.18 ㎛ BCD

  • Kim, Hongjin;Park, Young-Jun;Park, Ju-Hyun;Ryu, Ho-Cheol;Pu, Young-Gun;Lee, Minjae;Hwang, Keumcheol;Yang, Younggoo;Lee, Kang-Yoon
    • Journal of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.2024-2034
    • /
    • 2016
  • This paper presents a DC-DC buck converter with a Phase-Locked Loop (PLL) that can compensates for power efficiency degradation over a wide input range. Its switching frequency is kept at 2 MHz and the delay difference between the High side driver and the Low side driver can be minimized with respect to Process, Voltage and Temperature (PVT) variations by adopting the PLL. The operation mode of the proposed DC-DC buck converter is automatically changed to Pulse Width Modulation (PWM) or PWM frequency modes according to the load condition (heavy load or light load) while supporting a maximum load current of up to 1.2 A. The PWM frequency mode is used to extend the CCM region under the light load condition for the PWM operation. As a result, high efficiency can be achieved under the light load condition by the PWM frequency mode and the delay compensation with the PLL. The proposed DC-DC buck converter is fabricated with a $0.18{\mu}m$ BCD process, and the die area is $3.96mm^2$. It is implemented to have over a 90 % efficiency at an output voltage of 5 V when the input range is between 8 V and 20 V. As a result, the variation in the power efficiency is less than 1 % and the maximum efficiency of the proposed DC-DC buck converter with the PLL is 95.4 %.

Development of 30-Tonf LOx/Kerosene Rocket Engine Combustion Devices(I) - Combustion Chamber (추력 30톤급 액체산소/케로신 로켓엔진 연소장치 개발(I)-연소기)

  • Choi, Hwan-Seok;Han, Young-Min;Kim, Young-Mog;Cho, Gwang-Rae
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.10
    • /
    • pp.1027-1037
    • /
    • 2009
  • The development of a combustion chamber for a 30-$ton_f$ regeneratively-cooled space liquid rocket engine is described. Starting from the development of bi-propellant swirl coaxial injectors, essential technologies were verified through subscale combustion chambers and afterwards applied to the full-scale combustion chambers. A total of 5 full-scale combustion chambers have been utilized to verify ignition, combustion efficiency and stability, cooling, and duration requirements. A total of 46 combustion tests were performed among which 23 tests were parallely performed with stability rating tests using a pulse gun device. The test results have revealed that the 30-$ton_f$ regeneratively-cooled combustion chamber fully complies to the performance and combustion stability requirements and thus concluded that the development is successfully completed.

Digitally Controlled Single-inductor Multiple-output Synchronous DC-DC Boost Converter with Smooth Loop Handover Using 55 nm Process

  • Hayder, Abbas Syed;Park, Young-Jun;Kim, SangYun;Pu, Young-Gun;Yoo, Sang-Sun;Yang, Youngoo;Lee, Minjae;Hwang, Keum Choel;Lee, Kang-Yoon
    • Journal of Power Electronics
    • /
    • v.17 no.3
    • /
    • pp.821-834
    • /
    • 2017
  • This paper reports on a single-inductor multiple-output step-up converter with digital control. A systematic analog-to-digital-controller design is explained. The number of digital blocks in the feedback path of the proposed converter has been decreased. The simpler digital pulse-width modulation (DPWM) architecture is then utilized to reduce the power consumption. This architecture has several advantages because counters and a complex digital design are not required. An initially designed unit-delay cell is adopted recursively for the construction of coarse, intermediate, and fine delay blocks. A digital limiter is then designed to allow only useful code for the DPWM. The input voltage is 1.8 V, whereas output voltages are 2 V and 2.2 V. A co-simulation was also conducted utilizing PowerSim and Matlab/Simulink, whereby the 55 nm process was employed in the experimental results to evaluate the performance of the architecture.

New Drug Delivery System Based on a Laser-Induced Shockwave (레이저 유도 충격파를 이용한 첨단 약물전달시스템 개발)

  • Han, Tae-Hee;Lee, Hyun-Hee;Gojani, Ardian B.;Yoh, Jai-Ick
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.1
    • /
    • pp.67-71
    • /
    • 2010
  • Impingement of a high power laser pulse (above 1 GW/$cm^2$) on a metal foil causes its ablation, which is characterized by a rapid expulsion of matter and the initiation of a strong shock wave inside the solid metal. The shock propagates through the foil and reverberates on the rear side, causing its deformation and microparticle ejection, which were deposited on the foil prior to ablation. Based on this principle, we are developing a new drug delivery system - Biolistic gun. Current study is focused on the controllability, stability, efficiency of the system, and characterization of the penetration shapes in various conditions. We have tested the system by applying direct and confined ablation. Several different media combinations were used for confinement-BK7 glass, water, BK7 glass with water, and succulent jelly(ultrasono jelly, RHAPAPHRM). Biological tissue was replicated by a 3% gelatin solution. Present data shows that the confinement results in enhancement of penetration shape reached by 5 um cobalt microparticles. Based on the analysis of the experimental results we observe that the penetration shape of microparticles can be controlled by adjusting the thickness of confinement media.

Operatonal characteristics of the PLS linac vacuum system (PLS 선형가속기 진공계의 운전특성)

  • 김임경;박용정;김경렬;남궁원
    • Journal of the Korean Vacuum Society
    • /
    • v.5 no.4
    • /
    • pp.269-277
    • /
    • 1996
  • The vacuum systems of PLS linac provides average pressure of $2.6\times 10^{-6}$Pa under high power microwave of 54 MW peak with 4.1 $\mu \textrm s$ pulse width and 10 Hz repetition rates. The base pressure of system is$2.4\times 10^{-6}$Pa with 45$^{\circ}C$ cooling water. The outgassing rate of the system is decreased from $3.0\times 10^{-11}Torr-l/sec-\textrm{cm}^2$ at the initial stage after installation to $1\times 10^{-12}Torr-l/sec-\textrm{cm}^2$ at present. Total accumulated microwave energy dose is about 140 GJ per module. All ion pumps are working under saturated regime and effective pumping speeds of 60 I/s, 230 I/s ion pumps are 45 I/s, 65 I/s, 140 I/s under the operating range. Main problems occurred in recent year are troubles of ion pump controller and vacuum gauge controller, vacuum leak of energy doubler window and electron gun ceramic, and water leak in the dummy load of acceleraing columns. Total of 41 troubles with 140. 8 hours down time give good system availability of 98%. Down time can be reduced by high power waveguide valves and water dummy loads under development, and then availability is expected to be increased up to 99.5%.

  • PDF