• Title/Summary/Keyword: Pulse diagnosis analysis

Search Result 131, Processing Time 0.022 seconds

A study on The Pulse taking diagnostics of Nan Jing 1-23 Nan (난경(難經) 1-23난중(難中) 맥학조(脈學條)에 관한 연구(硏究))

  • Kim, Bup-Jin;Park, Won-Hwan
    • The Journal of Dong Guk Oriental Medicine
    • /
    • v.8 no.2
    • /
    • pp.131-154
    • /
    • 2000
  • Nan Jing(Difficult Classic), as a catechism, describes in detail and deeply the ideas in Nei Jing(Huangdi's Internal Classic). The description of Nan Jing is focused on basic theories including theories about some disease and is excellent in identification and analysis. The contents of Nan Jing are as follows: 1-23 Nan-pulse and pulse condition, 24~29 Nan-channels and collaterals, 30~47 Nan-viscera and bowels(Zang Fu organs), 48~61 Nan-disease, 62~68 Nan-acupuncture points, 69~91 Nan-acupuncture. Especially, diagnosis techniques in Nan Jing make 'Only method of cunkou pulse taking' that is a technique for feeling the pulse widely applied in these days in Oriental medicine clear. Thus, this book adjusts the theory of pulse and pulse condition given in 1~23 Nan of 'The Study of Nan Jing' in order to enhance an understanding about the theory of pulse and pulse condition. The text of 1~23 Nan about pulse lore centers on all pulse of human body interconnected each other and cunkou, both ends of the pulse, and contrasts regular pulse with irregular pulse. 1. 10 Nan describes the theory about five kinds of evils and hardness and softness, and unique pulse condition of each bowels. 2. 13 Nan explains that the relative difficulty of medical treatment is determined by the degree of balance or unbalance among three factors-colors, pulse and pulse condition, flesh shape. 3. 14 Nan divides pulse and pulse condition into slow pulse and rapid pulse, and explains separately abnormality, great loss of semen, death caused by slow pulse, and abnormality, great loss of semen, death caused by rapid pulse. 4. 15 Nan about taut pulse(弦), full pulse(鉤), floating pulse(毛), deep pulse(石脈) describes that pulse and pulse condition differs according to four seasons. Therefore, Nan Jing establishes clearly techniques of feeling the pulse in 'Only method of cunkou pulse taking(獨取寸口)' and advances the theory of Nei Jing. Futhermore, Nan Jing is more valuable in that it suggests unique theory different with Nei Jing.

  • PDF

Pulse Diagnosis Algorithm and Digital Filter Design for Development of Digital Biomedical System (전자 맥진기 시스템 개발을 위한 맥파분석 알고리즘과 디지털 필터 설계)

  • Kim, Sang-Ho;Lim, Duk-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.11
    • /
    • pp.4473-4482
    • /
    • 2010
  • The examination of pulse, which is a typical palpation technique in the oriental medicine, has been used conventional analog system for discrimination of 28 pulses. However, the clipping phenomenon in the pulses, which used same feature extraction technique with ECG signals, has been occurred in analog system due to feature extraction method and over amplification from the input signals. It caused inaccurate to analyze the pulse signals. In this paper, we propose a digital filter design technique based on Prony's method for signal modeling and C-spline interpolation for feature extraction from pulse signal to compensate analog pulse detection system. In addition, we suggest a compensated electronic pulse detection system comprising new pulse analyzing algorithm and shape analysis technique for pulses, which were difficult to use in analog system. The feasibility for new proposed system has been confirmed comparing output signals between electronic pulse detection system having proposed filter design techniques with pulse analyzing algorithm and conventional analog system.

Bioengineering Approaches to Quantitation of Diagnosis and Treatment Monitoring for Patients with Liver Cancer: Ultrasonic Image Processing by Kalman Filtering (의공학적 기법에 의한 간암의 검진과 치료경과의 정량 : 칼만 필터링 기법에 의한 초음파 영상 처리)

  • 우광방;남상일
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.1
    • /
    • pp.5-12
    • /
    • 1985
  • In this paper Kalman filtering technique is applied to ultrasound signal to improve resolution capability, Ivhlch is in use of diagnostic imaging systems. The main advantage of Kalman filter algorithm for the analysis of reflected ultrasound signal is its recursive structure which can be easily adapted to tlme varing system. Because soft-tissues, such as liver, act as distributed acoustic low-pass filters which continually change the propagating pulse. tIne can put to practical use above advantage to find a suitable signal generallng model. In state-space description of the system, the 6th order system produces tl)e 1)esc spectral approximation to the source pulse As a result of spectrum analysis, 6th order estimator for two closely spaced ((p.5 mm) reflectors enhances resolution by 4dB-lOdB. By using this result, the possibility to detect even minute tumor is demonstrated.

  • PDF

Partial Discharge Position Tracking Method using a GIS Partial Discharge Signal and Arrival Time Difference (GIS 부분방전 신호와 도착 시간차 분석을 통한 PD발생 위치 추적)

  • Choi, Mun-Gyu;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.9
    • /
    • pp.1297-1301
    • /
    • 2013
  • This paper analyzes of PD occurrence position through an analysis of the arrival time difference between the GIS partial discharge signal. Because of GIS (Gas Insulated Switchgear) is a facility very important power equipment and as part of the equipment that make up the power system, the stabilization of the power industry, which accounted for 88.5% share of GIS substation in the form of a substation is an important equipment for power supply. In the situation where we are gradually expanding the need for preventive diagnosis in order to improve the efficiency of equipment management and failure prevention for Preventive diagnosis. In this paper as a method for extracting pre-defect of failure of GIS Apply the average value method of calculating the 5 times each using a pulse of the first time of the second pulse (${\Delta}t$) with an oscilloscope generation position PD(Partial Discharge). the results of GIS internal inspection, the partial discharge of the actual the position of the partial discharge was confirmed with an accuracy of about 82% of positions. Arrival time difference in the most effective manner if the partial discharge of GIS internal occurs by applying the averaging method and TOA(Time of arrival) method, the partial discharge occurs you through the measurement and analysis of PD signal occurs was confirmed in the experiment are presented and diagnostic methods location tracking.

Systolic blood pressure measurement algorithm with mmWave radar sensor

  • Shi, JingYao;Lee, KangYoon
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.4
    • /
    • pp.1209-1223
    • /
    • 2022
  • Blood pressure is one of the key physiological parameters for determining human health, and can prove whether human cardiovascular function is healthy or not. In general, what we call blood pressure refers to arterial blood pressure. Blood pressure fluctuates greatly and, due to the influence of various factors, even varies with each heartbeat. Therefore, achievement of continuous blood pressure measurement is particularly important for more accurate diagnosis. It is difficult to achieve long-term continuous blood pressure monitoring with traditional measurement methods due to the continuous wear of measuring instruments. On the other hand, radar technology is not easily affected by environmental factors and is capable of strong penetration. In this study, by using machine learning, tried to develop a linear blood pressure prediction model using data from a public database. The radar sensor evaluates the measured object, obtains the pulse waveform data, calculates the pulse transmission time, and obtains the blood pressure data through linear model regression analysis. Confirm its availability to facilitate follow-up research, such as integrating other sensors, collecting temperature, heartbeat, respiratory pulse and other data, and seeking medical treatment in time in case of abnormalities.

A Study on the Waveform Analysis of Left KWAN Pulse Dignosis by the Pressure (단계별(段階別) 가압(加壓)에 따른 좌관부위(左關部位) 맥파(脈波) 변화(變化))

  • Kim, Gyeong-Cheol;Lee, Jeong-Won;Ryu, Kyeong-Ho;Kim, Jong-Hwan;Park, Ju-Yeon
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.13 no.1
    • /
    • pp.19-35
    • /
    • 2009
  • Objectives : In the study on the waveform analysis of radial artery pulse diagnosis, we need to establish fundamentals of contemporary pulse diagnosis research. To achieve certain experimental basis on traditional pulse diagnosis, we have to research the differences of pulse waveform according to pressure (in 5 level) and position (Chon, Gwan, Cheok in radial artery). As a first step, in present thesis, we tried to find the differences of pulse waveform according to pressure. Methods and Results : In this research, we analyzed seven parameters of the waveform at five levels of pressure. The parameters are E(so called 'energy', a representative of pulse strength), h1(height of percussion wave) and h2(height of subincisura). The results were as follows. 1. When we analyzed the change of the waveform according to pressure in the left Gwan, E, hl, h2 and A differed between 1st and 2nd grade, between 1st and 3rd grade, between 1st and 4th grade, between 1st and 5th grade, between 2nd and 3rd grade, between 2nd and 5th grade, between 3rd and 5th grade and between 4th and 5th grade in 95% confidence interval. 2. And t2, t4 differed between 1st and 2nd grade, between 1st and 5th grade, between 2nd and 4th grade, between 2nd and 4th grade, between 2nd and 5th grade, between 3rd and 4th grade, between 3rd and 5th grade and between 4th and 5th grade in 95% confidence interval. 3. W differed between 1st and 3rd grade, between 1st and 4th grade, between 2nd and 3rd grade, between 2nd and 4th grade, between 2nd and 5th grade, between 3rd and 4th grade, between 3rd and 5th grade, and between 4th and 5th grade in 95% confidence interval. 4. And h2/h1 differed between 1st and 4th grade, between 1st and 5th grade, between 2nd and 4th grade, between 2nd and 5th grade, between 3rd and 4th grade & between 3rd and 5th grade in 95% confidence interval. 5. There were differences between 1st and 2nd grade & between 2nd and 5th grade in the case of t4/t2 in 95% confidence interval. And there were differences between 1st and 5th grade, between 3rd and 4th grade, between 3rd and 5th grade & between 4th and 5th grade in the case of W/A in 95% confidence interval. And were differences between 1st and 2nd grade, between 2nd and 3rd grade, between 2nd and 4th grade, between 3rd and 4th grade, between 3rd and 5th grade & between 4th and 5th grade in the case of A/E in 95% confidence interval. Conclusions : As mentioned above, we conclude that the waveform analysis according to five grade pressure in the left Gwan shows the difference of waveform in each grade pressure.

  • PDF

A Sham Experiment for the Measurement of Nonlinear Pulse Propagation Characteristics of Blood Vessel Using Bispectral Analysis (바이스펙트럼해석을 이용한 혈관의 비선형 맥동전파특성 계측에 대한 모의실험)

  • 장경영;김경조
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.4
    • /
    • pp.525-532
    • /
    • 1995
  • In this paper, a new try to measure nonlinear propagation characteristics of the pulse along blood vessel by using bispectral analysis is introduced, and the possibility of its application to the medical diagnosis is shown. In this method, the waveforms of pulse motion of blood vessel at two separated measuring points on the wall were detected from Doppler frequency modulation of transmitted probing ultrasonic waves. Then the auto- and crossbispectrum of detected waveforms are calculated to estimate the quadratic NTF (nonlinear transfer function) between the two measuring positions. In order to show relationships between the NTF and the nonlinear propagation characteristics, computer simulations have been performed. As the propagation distance increases, harmonic frequency components in NTF increases broadly due to the nonlinear effect in the propagation of blood pulse. In order to represent this phenomena quantitatively, we propose a new parameter, dispersion ratio of WTF. Basic experimental system was constructed by using 3.5MHz probing ultrasonic waves and the preliminary experiments were carried out on ague phantom and human body. Experimental results showed the validity of the measurement system enoughly.

  • PDF

A Study on the Clinical Use of 7-zone-Diagnostic System (2) - the Comparative Analysis of the Rule and the Decipher for each Equipment - (7구역진단기의 임상응용에 대한 고찰 (2) - 각 제품에 따른 원리와 판독의 비교 -)

  • Song, Beom-Yong
    • Journal of Acupuncture Research
    • /
    • v.23 no.5
    • /
    • pp.11-21
    • /
    • 2006
  • The 7-zone-diagnostic system(ABR-2000, BIO MEDIC 700Plus, CP-6000A, OMD 3000, VEGA-DFM 722) is a diagnostic device which applies pulse signals to predetermined bodily locations. Applying alternating positive and negative stress to tissues with positive and negative pulses first manifests itself as negative and positive wave forms. This system make a diagnosis of functional disorder or some typical organic diseases include stress of the mind or the body, and the energetic situation, reserves. We are known a disorder or disease throw the result charts. And these result represents various characteristic signals are assisted diagnosis and care. These result chart contains disorder flow wave forms and some valuable diagnostic hints or marks. But we have several various products for the 7-zone-diagnostic system. I think that we need the comparative analysis of the general rule and the decipher for each equipment. Because these letters(marks) each product are different, we necessary various plentiful research and suitable statistics in these points. And we must carry out many various research in the future.

  • PDF

Analysis of an Error Accompanying Measured Surface Crack Depth of Concrete Using Ultrasonic Pulse Velocity Method (초음파법에 의한 콘크리트 표면 균열 깊이의 측정오차 분석에 관한 연구)

  • 박석균;최욱
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.175-180
    • /
    • 2003
  • Ultrasonic pulse velocity method is applied many times for measuring surface crack depth of concrete in case of diagnosis of concrete structures. By the way, this method has an error accompanying measured surface crack depth of concrete because there are many uncertainty factors. So, it is necessary to study for an error of this method affected by these uncertainty factors. Two error factors(uncertainty factors) are tested and analyzed in this study. One is for an error according to measuring the propagation time of ultrasonic wave and the arrangement distance of transducers. Another is for an error according to positioning the transducer as a distance to surface crack from the transducer.

  • PDF

A Study on Men's 8-Constitutional Characteristics Using the Oneway Analysis of Variance (일원배치 분산분석을 응응한 남자의 한의학적 8체질 임상특성 연구)

  • Rhee Sang-Beom;Park Young-Bae;Choi Kyung-Mee
    • The Korean Journal of Applied Statistics
    • /
    • v.19 no.2
    • /
    • pp.203-215
    • /
    • 2006
  • In Oriental Medicine, there have been a number of researches in 8-Constitution medicine which classifies human bodies into one of 8 categories. Since the diagnosis of 8-Constitution depending on pulse types is often subjective, standardization of the diagnosis and therapy requires objective characteristics of 8 constitutions. A questionnaire of 80 items about personal symptoms were given to patients while they were classified into one of 8 constitutions based on their pulse types and responses to constitution-based acupuncture therapy. One-way analysis of variance and Duncan's multiple comparison test were used to verify the significant items. Most of the significant items in this study coincided with supposed-to-be clinical characteristics of 8-constitutions.