• Title/Summary/Keyword: Pulse diagnosis analysis

Search Result 131, Processing Time 0.022 seconds

The Diagnosis technique of Partial Discharges using Antenna (안테나를 이용한 부분방전의 진단기병에 관한 연구)

  • Kim, Young-No;Kim, Jae-Chul;Jeon, Young-Jae;Seo, In-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.217-219
    • /
    • 2001
  • This paper presents new diagnosis technique for detecting a partial discharge(PD) using antenna. The wavelet transform is applied for the analysis of PD pulse signal because it is difficult to identify PD signal using electromagnetic waves detected by antenna. The capabilities of the proposed diagnosis methodology for detecting PD signal is verified on experiment in laboratory.

  • PDF

The Relationship between Risk Factors, Warning Signs, Tongue Diagnosis, Pulse Pattern, Pattern Identification and National Institute of Health Stroke Scale in Acute Stroke Patients (급성기 중풍환자의 위험요인, 경고증상, 전조증상 및 설진, 맥상, 변증과 NIHSS의 관련성 연구)

  • Kim, Mi-Young;Choi, Won-Woo;Park, Su-Kyung;Leem, Jung-Tae;Park, Sung-Wook;Jung, Woo-Sang;Cho, Ki-Ho
    • The Journal of Internal Korean Medicine
    • /
    • v.30 no.4
    • /
    • pp.708-718
    • /
    • 2009
  • Objectives : The aim of this study was to assess the relationship between risk factors, warning signs, tongue diagnosis, pulse pattern, pattern identification and National Institute of Health Stroke Scale in acute stroke patients. Methods : We studied patients hospitalized within 4 wks after their ictus who were admitted at the Internal Medical Department at Kyunghee Oriental Medical Center, Kyunghee University East-West Neo Medical Center, Kyungwon University Songpa Oriental Medical Center, Kyungwon University Incheon Oriental Medical Center, Dongguk University Ilsan Oriental Medical Center from April 2007 to August 2009. We analyzed the relationship between risk factors, warning signs, tongue diagnosis, pulse pattern, pattern identification and National Institute of Health Stroke Scale in acute stroke patients. Results : 1506 subjects were included into the final analysis. 1. In the risk factors, the NIHSS mean score of atrial fibrillation was significantly higher than non-atrial fibrillation. 2. In the warning signs, the NIHSS mean scores of weakness, loss of eyesight, dysarthria, and sensory loss were significantly higher than in the non-warning signs. 3. There were no significant differences in lifestyle, tongue fur color, pattern identification between groups. 4. In the tongue color, the NIHSS mean score of red was significantly higher than pale or pale red. 5. There were significant differences statistically between forceful/weak, fine/not fine, slippery/not slippery pulse and NIHSS score. Conclusion : The above results show the relationship between risk factors, warning signs, tongue diagnosis, pulse pattern, pattern identification and National Institute of Health Stroke Scale in acute stroke patients. These results can be utilized in the future as a basis material.

  • PDF

Correlations between Postpartum Edema and Pulse Energy Measured by 3D Blood Pressure Pulse Analyzer (3D Blood Pressure Pulse Analyzer로 측정한 맥파 에너지와 산후 부종과의 상관성 연구)

  • Lee, Ji-Yeon;Yun, Young-Jin
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.27 no.1
    • /
    • pp.167-175
    • /
    • 2014
  • Purpose: This study was performed to find correlations between Edema Index and Pulse Energy in early postpartum period. Methods: Fiftynine postpartum women were participated in this study which was conducted with Inbody 720 (Biospace Co. Ltd) and 3D Blood Pressure Pulse Analyzer (3D-MAC). Edema Index (Extra Cellular Water/Total Body Water) calculated after body composition analysis and 3D-MAC result (Pulse Energy) were analysed within a week after delivery. Results: The results were as follows 1. Edema Indexes of the upper, lower limbs, trunk and whole body were associated with each other respectively. 2. Edema Indexes and Right Kwan pulse energy had significant positive correlation. 3. Right Kwan pulse energy showed positive correlations with Left Kwan, Right Chon, Right Cheok. Conclusions: Viscera associated with Postpartum Edema are Spleen, Lung, Liver and Vital Gate. The most important thing is thought to be Spleen.

A Study on Quantitative Analysis for Treeing Deterioration Diagnosis Using Acoustic Detection (음향탐지를 이용한 트리잉의 열화진단을 위한 정량적 분석에 관한 연구)

  • 이덕진;신성권;김재환
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.4
    • /
    • pp.68-74
    • /
    • 1999
  • Ths paper does acoustic detection of partial discharge using acoustic sensor in polymer. Time sequential rreasurement of acoustic emission characteristic obtained acoustic sensor deal with statistics process. and 5 characteristic quantities were introduced into this paper. Resulting fann analysis of $\psi$-AEA-n pattern (phase-acoustic emission amplitude-pulse number) and AE quantities ,it can know useful statistics quantities that AE average inception amplitude TEX>$(\overline{AEA_{inc}})$ and AE average maximum amplitude TEX>$(\overline{AEA_{max}})$ make diagnosis of the middle stage of deterioration, AE pulse number and AE average maximum phase $(\overline{\theta{max}})$ make diagnosis of the last stage of deterioration. it obtained that these AE quantities are useful for dias,mosis deterioration form experiment results.esults.

  • PDF

Study on the Basic Pulse Indicators for Pattern Identifications in Stroke (중풍환자의 변증에 사용되는 맥진 지표에 관한 연구)

  • Lee, Jung-Sup;Ko, Mi-Mi;Kang, Byoung-Kab;Kim, So-Yeon;Kim, Jeong-Cheol;Oh, Dal-Seok;Lee, In;Kim, Yun-Sik;Bang, Ok-Sun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.5
    • /
    • pp.964-968
    • /
    • 2009
  • The purpose of this study is to select the major pulse indicators and evaluate their significance in discriminating the subtypes of Pattern Identifications (PI) from stroke patients. Decision tree analysis was carried out using clinical data collected from 835 stroke patients with the same subtypes diagnosed identically by two experts with more than 3 year clinical experiences. Among the 10 pulse indicators, 6 major pulse indicators (slow, rapid, strong, weak, slippery, and fine pulse) were selected by decision tree analysis. The accumulated distributions of six pulse indicators in each PI showed that strong was major pulse indicator in Fire-Heat pattern, slippery in Dampness Phlegm pattern, weak in Qi Deficiency pattern. But there were two major combinations in Yin deficiency pattern, weak or fine with rapid pulse and weak or fine without rapid pulse. Therefore, it is suggested that 6 pulse indicators can be used for discrimination of PI in stroke patients, though the combination studies between these pulse indicators and the other PI indicators are left for further study.

A Study on the Relationship between Primary Dysmenorrhea and Pulse Energy Measured by 3D Blood Pressure Pulse Analyzer (원발성 월경곤란증과 맥의 관련성 연구)

  • Lee, Ji-Yeon;Yoon, Young-Jin
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.28 no.4
    • /
    • pp.31-45
    • /
    • 2015
  • Objectives : The purpose of this study is to examine the relationship between the symptoms of primary dysmenorrhea and pulse energy of Chon, Gwan and Cheok. Methods The subjects of this study who had certain range of dysmenorrhea symptom. The degree of dysmenorrhea were assessed by Visual Analog Scale (VAS), Multidimensional Verbal Rating Scale (MVRS), Cox Menstrual Symptom Scale (CMSS) and measured by 3D Blood Pressure Pulse Analyzer(3D-MAC) tests at menstruation start date. Data analysis included descriptive statistics and multiple linear regression using the SPSS/WIN 18.0 program. Results : The induced results are as follows;The induced results are as follows 1. There were no significant relationship between the pulse energy and the sum values of VAS, MVRS and checking part of severity of CMSS. 2. The frequency domain of CMSS were significantly associated with pulse energy. 3. In linear regression models, the model of Left Chon had the especially highest value of explanatory power. (R 2 = 0.517) Conclusions : The pulse energy changes are related to the symptoms of primary dysmenorrhea.

A Study on Pulse Energy Measured by 3D Blood Pressure Pulse Analyzer in Women Who Complain of Climacteric and Menopausal Symptoms (갱년기증후군 및 폐경 관련 증상을 호소하는 여성의 맥파 분석 연구)

  • Lee, Ji-Yeon;Yoon, Young-Jin
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.28 no.1
    • /
    • pp.73-84
    • /
    • 2015
  • Purpose: The purpose of this study is to analyze the characteristics of the pulse energy in women who complain of climacteric and menopausal symptoms. Methods: We analyzed the values of pulse energy on 45 climacteric and menopausal women. The patients' symptoms were assessed by Kupperman's index and Menopause Rating Scale (MRS). Statistical analysis was performed using SPSS 18.0 for window program, one way ANOVA, pearson correlation coefficient. Results: The results were as follows. 1. The pulse energy of the Left Chon was significantly largest and Left Cheok was comparatively smallest. 2. There was no statistically significant correlation in the pulse energy of Left Chon minus Left Cheok, Kupperman's index, MRS total sum score. Conclusions: The results suggest that the pulse energy of the Left Chon tends to be increased and Left Cheok decreased in climacteric and menopausal women.

Comparative Study between the Finger Photoplethysmographic Waveform of the Old and That of the Young Whose Harmonics Deceased with Notch Filtration (고조파 성분 여과 전후의 지첨용적맥파 파형의 비교)

  • Nam, Tong-Hyun;Shin, Sang-Hoon;Park, Young-Jae;Park, Young-Bae
    • The Journal of Korean Medicine
    • /
    • v.29 no.2
    • /
    • pp.60-70
    • /
    • 2008
  • Objectives: The aim of the present investigation was to determine whether the finger photoplethysmography (PPG) of the young will become analogous to those of the old when the PPG harmonic components in the young decrease. Methods: The PPG was measured in 46 old men (21 males and 25 females) over the age of 60 years and 10 young men (5 males and 5 females). We acquired the representative pulse waveform of old men by averaging the PPG waveforms measured in the old men. after the PPG harmonic components in the young men were diminished with notch filtering, we compared the representative pulse waveform of old men and those of the young men. Results: The PPG waveform of the young males became analogous to the representative pulse waveform of the old as the PPG harmonic components in the young were diminished with notch filtering. Especially after the second harmonic component in the young was diminished with notch filtering, increase of the Pearson's correlation coefficient was prominent. On the other hand, the Pearson's correlation coefficient between the PPG waveforms of the young females and that of the old deceased after the second harmonic component diminished in the young. Conclusions: Decrease of the second harmonic component may be a precondition of typical age-related change of the pulse waveform in the healthy male.

  • PDF

Finite Element Analysis of Packaging Shape for Pulse Diagnosis Sensor (FEM 분석을 통한 맥진센서모듈의 패키징 형태와 응력분포)

  • Shin, Ki-Young;Lee, Sang-Sik;Joo, Su-Bin
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.4 no.3
    • /
    • pp.167-173
    • /
    • 2011
  • Since many blood pressure pulse analyzer made to measurement of a pulse wave in quantitative way has been started, some sorts of pressure sensors are being developed. The result could differ and this cause either type of sensor or module shape, when pulse wave is measured. In this paper, calculate and compare the pressure sensor's stress distribution according to thickness of PDMS coating and existence of guide through Finite Element Method. As a result, the center of pressure sensor's stress increase as much as 24% as it is reduced as much as 0.3 mm that the PDMS coating thichness of pulse diagnostic sensor module, on the other hand the surrouding censor of center sensor's stress is reduced as much as 4.9%, and transmissive proportion of stress is small as little as 2.7%, When coating has guide.

Analysis of Relations Between Physiologic Parameters and Pulse Transit Time on the Ultrasound Therapy (초음파 재활치료 시 PTT와 생리변수의 상관관계 분석)

  • Kim, Sung-Min;Choi, Sang-Hyuk;Lee, Man-Pyo;Choi, Byeong-Cheol;Jung, Whoi-Seong;Park, Sung-Yoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1514-1520
    • /
    • 2007
  • Currently, the signal of the human body is measured with various methods, and a noninvasive investigation of various methods is useful diagnosis method. PTT(Pulse Transit Time) which is noninvasive investigation make use of to estimate the physiological phenomena. PTT has a latent information of cardiovascular system. So we have the experiments for analysis of the relations between PTT and physiological parameters. We examine to correlate to the physiological parameters, an age and degree of paralysis on the ultrasound therapy. The 40 patients who has a such paralysis join our experiment, and we obtain the PTT data that normal condition and states after ultrasound therapy. We study that PTT after the ultrasound therapy for patients who have a paralysis was related to an age and degree of paralysis.