• Title/Summary/Keyword: Pulse design

Search Result 1,439, Processing Time 0.028 seconds

System Design and Performance Analysis of 3D Imaging Laser Radar for the Mapping Purpose (맵핑용 3차원 영상 레이저 레이다의 시스템 설계 및 성능 분석)

  • La, Jongpil;Ko, Jinsin;Lee, Changjae
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.90-95
    • /
    • 2014
  • The system design and the system performance analysis of 3D imaging laser radar system for the mapping purpose is addressed in this article. For the mapping, a push-bloom scanning method is utilized. The pulsed fiber laser with high pulse energy and high pulse repetition rate is used for the light source of laser radar system. The high sensitive linear mode InGaAs avalanche photo-diode is used for the laser receiver module. The time-of-flight of laser pulse from the laser to the receiver is calculated by using high speed FPGA based signal processing board. To reduce the walk error of laser pulse regardless of the intensity differences between pulses, the time of flight is measured from peak to peak of laser pulses. To get 3D image with a single pixel detector, Risley scanner which stirs the laser beam in an ellipsoidal pattern is used. The system laser energy budget characteristics is modeled using LADAR equation, from which the system performances such as the pulse detection probability, false alarm and etc. are analyzed and predicted. The test results of the system performances are acquired and compared with the predicted system performance. According to test results, all the system requirements are satisfied. The 3D image which was acquired by using the laser radar system is also presented in this article.

Study on the Optimization of Pulse GTAW Process for Diaphragm with Thin Thickness (극박 다이아프램의 펄스 GTAW 공정 최적화에 관한 연구)

  • Park, Hyoung-Jin;Hwang, In-Sung;Kang, Mun-Jin;Rhee, Se-Hun
    • Journal of Welding and Joining
    • /
    • v.26 no.1
    • /
    • pp.63-68
    • /
    • 2008
  • This paper has aimed to prevent excessive heat input by controlling arc distribution and heat input capacity with pulse GTAW in order to improve weld quality in 0.08mm pressure gauge diaphragm and flange welding parts. A design of experiment was designed using Box-Behnken method to optimize a welding process. The pulse GTAW parameters such as pulse current, base current, pulse duty, frequency and welding speed were set to input variables while hydraulic pressure that represents welding characteristics in diaphragm and flange joint were set to output variables. Based on the test result, a second regression equation was obtained between input and output variables and turned out significant. Besides, an influence of parameters has been confirmed through response surface analysis using the second-order regression equation and optimum welding condition was obtained through a grid-search method. The optimum welding condition was set to pulse current 84.4(A), base current 29.6(A), pulse duty 58.8(%), frequency 10(%), and welding speed 596(mm/min). Then, decent bead shape was acquired with no excessive heat input under the $2.3kgf/cm^2$ of hydrostatic pressure.

Design and Implementation of Pulse Monitoring System for U-Healthcare (U-Healthcare 지원을 위한 맥박 정보 모니터링 시스템의 설계 및 구현)

  • Kwon, Ki-Hyeon;Lee, Hyung-Bong
    • Journal of Digital Contents Society
    • /
    • v.9 no.4
    • /
    • pp.601-606
    • /
    • 2008
  • U-Healthcare is one of the major applications in ubiquitous sensor network. U-Healthcare has potential to become a critical service for the people who immediately require emergency ambulatory attention. This paper describes about the real time pulse monitoring and reporting system, consisting of two components: thus, the one is a reliable bio-sensor that continuously monitors the pulse information of the subject, and the other is the automatic transfer system that transmits pulse information to both his/her family and hospital care system through the Base Station. In the hospital, this bio-information can be used to treat the patient accordingly. I designed the pulse information monitored by a bio-sensor module that transfers the pulse information to both the Base Station and the central monitoring system through transmitting protocols such as Zigbee and TCP/IP, as well as designed the architecture of information packets for the corresponding protocols. Furthermore, the central monitoring system automatically parses the pulse information of the subject into the web database server, which can continuously provides the real time information and status of the subject via an internet browser to the clients who are family members of the subject and the authenticated medical care personnel as well.

  • PDF

Fabrication and Evaluation of Sensor for Measuring Pulse Wave Velocity using Piezo Film and Conductive Textile (압전 필름과 전도성 섬유를 이용한 맥파 전달 속도 측정을 위한 센서의 제작 및 성능평가)

  • Kim, Jung-Chae;Jee, Sun-Ha;Yoo, Sun-Kook
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.135-143
    • /
    • 2012
  • Arterial stiffness is causing the serious problems for human who is suffered from hypertension and metabolic syndrome. So it is important that measure the arterial stiffness for early prevention. Many researches point out that pulse wave velocity(PWV) is the reliable and simple method to predict arterial stiffness. In this paper, we developed the sensing parts that detect the pulse wave and ECG by using piezoelectric film and conductive textile with elastic band. Our system could detect 3ch pulse wave and ECG. Simultaneously, our algorithm extracts the features for calculating the delays among pulse waves. The delays are the significant parameter to estimate PWV, thus we design the experiment for evaluating the performance of our sensing parts. The reference is PP-1000(HanByul Meditech, Korea) that is good for performance evaluation. As a result, the start point of the pulse wave was the most reliable feature for comparing with PP-1000(r=0.691, P=0.00). The results between two operators showed that there is only a slight difference in the reproducibility of the devices. In conclusion, we assume that the suggested sensor could be more comfortable and faithful method for arterial stiffness.

Crosstalk Analysis accrording to Characteristics of Pulse Signal on the Multi Microstriplines unsing the SPICE (SPICE를 이용한 마이크로스트립 다중 전송선로에서 펄스 특성에 따른 선로의 누화특성 해석)

  • 김기래;이영철
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.36T no.1
    • /
    • pp.79-85
    • /
    • 1999
  • The propagation properties of the high speed pulse signal in time domain using the equivalent circuits for the analysis by SPICE on the coupled microstrip lines are investigated. In this paper, the SPICE program is used for the crosstalk analysis on the coupled microstrip lines. The results of crosstalk of coupled microstrip lines compared to one by Branin and FDTD method. And the near-end and far-end crosstalk on coupled lines are analyzed for the square pulse and trapezoidal pulse. The results of this paper are apply To the determination for the geometric structure and the frequency of signal pulse in design of MIC and MMIC by the CAD program.

  • PDF

A Review on Clinical Studies on Gynecological Disease by Using a Pulse Diagnosis Device (맥진기를 활용한 부인과 질환 대상 임상연구 고찰)

  • Kim, Ji-Hye;Kim, Jong-Yeol
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.29 no.3
    • /
    • pp.23-34
    • /
    • 2016
  • Objectives: The purpose of this study was to survey the status of clinical use of a pulse tonometric device (PTD).Methods: We searched domestic and international articles using the PTD from online medical databases including OASIS, RISS, DBpia and PubMed. We selected articles on clinical application of PTD but excluded articles on mechanical design or software programming for developing a new PTD. Finally we found 13 articles and classified the articles according to the disease of clinical study.Results: Out of the 13 articles, 5 were focused on the dysmenorrhea. Three articles were focused on the infertility, two article were focused on the post mastectomy. According to the results, the pulse energy has been widely used in research as the primary outcome.Conclusions: We found out that until now the researches on clinical application of PTD mainly had been performed for producing a variety of PTDs. This results of this study will be used as a useful information during perform a clinical study and clinics. We suggest that the standard operating procedure for PTD will be developed, and researches for development and its application of various new contents will be performed.

Design of Efficient Trapezoidal Filter and Peak Value Detection Circuit for XRF Systems (XRF시스템용 효율적인 Trapezoidal 필터 및 최대값 검출 회로 설계)

  • Piao, Zheyan;Chung, Jin-Gyun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.6
    • /
    • pp.138-144
    • /
    • 2013
  • In XRF systems, various techniques have been developed for the synthesis of pulse shapes using digital methods instead of traditional analog methods. Trapezoidal pulse shaping algorithms can be used for digital multi-channel pulse height analysis in X-ray spectrometer systems. In this paper, an efficient trapezoidal filter architecture is presented. In addition, we present a hardware-efficient peak value detection algorithm. By the proposed algorithm, peak value detection error is decreased by half compared with the conventional algorithm. The proposed Digital Pulse Processing(DPP) algorithm is designed using Verilog HDL and implemented using an FPGA on a test board. It is demonstrated that the implemented DPP board works successfully in practical XRF systems.

Design and Measurement of SFQ DFFC and Inverter (단자속 양자 DFFC와 Inverter의 설계와 측정)

  • 정구락;홍희송;박종혁;임해용;강준희;한택상
    • Progress in Superconductivity
    • /
    • v.5 no.1
    • /
    • pp.17-20
    • /
    • 2003
  • We have designed and measured a SFQ(Single Flux Quantum) DFFC and an Inverter(NOT) for superconducting ALU(Arithmetic Logic Unit) development. To optimize the circuit, we used Julia, XIC, and L meter for circuit simulations and circuit layouts. The Inverter was consisted of a D Flip-Flop, a data input, a clock input and a data output. If a data pulse arrives at the inverter, then the output reads ‘0’ (no output pulse is produced) at the next clock period. If there is no input data pulse, it reads out ‘1’(output pulse is produced). The DFFC was consisted of a D flip-Flop, an Inverter, a Data in, a Clock in and two outputs. If a data pulse arrives at the DFFC circuit, then the output2 reads ‘1’ at the next clock period, otherwise it reads out ‘1’ to output1. Operation of the fabricated chip was performed at the liquid helium temperature and at the frequencies of 1KHz.

  • PDF

Effects of Pulse Modulations on Particle Growth m Pulsed SiH4 Plasma Chemical Vapor Deposition Process (펄스 SiH4 플라즈마 화학기상증착 공정에서 입자 성장에 대한 펄스 변조의 영향)

  • Kim, Dong-Joo;Kim, Kyo-Seon
    • Journal of Industrial Technology
    • /
    • v.26 no.B
    • /
    • pp.173-181
    • /
    • 2006
  • We analyzed systematically particle growth in the pulsed $SiH_4$ plasmas by a numerical method and investigated the effects of pulse modulations (pulse frequencies, duty ratios) on the particle growth. We considered effects of particle charging on the particle growth by coagulation during plasma-on. During plasma-on ($t_{on}$), the particle size distribution in plasma reactor becomes bimodal (small sized and large sized particles groups). During plasma-off ($t_{off}$), there is a single mode of large sized particles which is widely dispersed in the particle size distribution. During plasma on, the large sized particles grows more quickly by fast coagulation between small and large sized particles than during plasma-off. As the pulse frequency decreases, or as the duty ratio increases, $t_{on}$ increases and the large sized particles grow faster. On the basis of these results, the pulsed plasma process can be a good method to suppress efficiently the generation and growth of particles in $SiH_4$ PCVD process. This systematical analysis can be applied to design a pulsed plasma process for the preparation of high quality thin films.

  • PDF

A study on the in-line type inertance tube pulse tube cryocooler for cooling Superconductor filter

  • Park, Seong-Je;Hong, Yong-Ju;Kim, Hyo-Bong;Kim, Seon-Young;Jung, Woo-Seok
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.4
    • /
    • pp.46-50
    • /
    • 2004
  • The Experimental results of the in-line type inertance tube pulse tube cryocooler for cooling superconductor RF filter are presented in this paper. The pulse tube refrigerator, which has no moving parts at its cold section, is attractive in obtaining higher reliability, simpler construction, and lower vibration than any other small refrigerators. The purpose of this study is to analyze the characteristics of in-line type inertance tube pulse tube refrigerator (IPTR), and to get main factor to improve the performance of the in-line type IPTR. Firstly, design parameters of the in-line IPTR are discussed by ARCOPTR program, and then to find optimal conditions of in-line type IPTR, cool down characteristics according to the variations of the charging pressure, inertance tube volume, regenerator volume and pulse tube volume are measured by the experiment. The lowest temperature of the cold end was about 50 K. Cooling capacity was the highest in the charging pressure of 32 atm. and 5W at 72K. On the other hand, COP of the in-line type IPTR was the highest in the charging pressure of 21 atm. and 0.018 at 77K.