• Title/Summary/Keyword: Pulse design

Search Result 1,442, Processing Time 0.034 seconds

Performance improvement of 2 stage GM-type pulse tube Cryocooler for cryopump

  • Park, Seong-Je;Koh, Deuk-Yong;Suh, Jeong-Kyoon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.13 no.4
    • /
    • pp.30-35
    • /
    • 2011
  • This paper describes experimental study and performance improvement of 2 stage Gifford-McMahon (G-M) type pulse tube cryocooler for cryopump. The objective of this study is to improve the efficiency of 2 stage pulse tube cryocooler for substituting 2 stage G-M cryocooler used in cryopump. The target cooling capacities are 5 W at 20 K and 35 W at 80 K for the $1^{st}$ and the $2^{nd}$ stage, respectively. These values are good cooling capacities for vacuum level in medium size ICP 200 cryopump. Design of the 2 stage pulse tube cryocooler is conducted by FZKPTR(Forschungs Zentrum Karlsruhe Pulse Tube Refrigerator) program. In order to improve the performance of 2 stage pulse tube cryocooler, U-type pulse tube cryocooler is fabricated and connecting tubes are minimized for reducing dead volumes and pressure losses. Also, to get larger capacities, orifice valves and double inlet valves are optimized and the compressor of 6 kW is used. On the latest unit, the lowest temperatures of 2 stage pulse tube cryocooler are 42 K ($1^{st}$ stage) and 8.3 K ($2^{nd}$ stage) and the cooling capacities are 40 W at 82.9 K ($1^{st}$ stage) and 10 W at 20.5 K ($2^{nd}$ stage) with 6.0 kW of compressor input power. This pulse tube cryocooler is suited for commercial medium size cryopump. In performance test of cryopump with 2 stage pulse tube cryocooler, pumping speed for gaseous nitrogen is 4,300 L/s and the ultimate vacuum pressure is $7.5{\times}10^{-10}$ mbar.

Dynamic Pressure Characteristics of Pulse Gun Device for Combustion Stability Rating of Liquid Rocket Engines (액체 로켓엔진 연소 안정성 평가를 위한 압력 교란 장치 특성 연구)

  • Seo,Seong-Hyeon;Go,Yeong-Seong;Lee,Gwang-Jin;Park,Seong-Jin;Lee,Su-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.7
    • /
    • pp.94-99
    • /
    • 2003
  • For the assessment of combustion stability of a liquid rocket engine, a device called "Pulse Gun" should be developed first, which can induce artificial perturbations that may lead to excitations of pressure oscillations in a combustion chamber. A model chamber has been used for identifying design parameters of a pulse gun that defines its characteristics. Dynamic pressure measurements showed that shock waves generated from pulse guns are axisymmetric around the axis of a pulse gun barrel. Pressure waves perturbed by a pulse gun induce resonant acoustic frequencies of a model chamber. This fact indicates that successful pressure field perturbations of the KSR-III combustion chamber can be performed by a newly developed pulse gun device. A maximum value of dynamic pressure peaks measured at the opposite point against a pulse gun outlet becomes stronger as charge mass of pulse gun powder increases.

Development of 3.6 MW, 4 ${\mu}s$, 200 pps Pulse Modulator for a High power magnetron (고출력 마그네트론 구동용 3.6 MW, 4 ${\mu}s$, 200 pps 펄스모듈레이터 개발)

  • Son, Y.G.;Jang, S.D.;Oh, J.S.;Cho, M.H.;NamKang, W.;Lee, H.K.;Bae, Y.S.;Lee, K.T.;Son, B.H.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1778-1780
    • /
    • 2004
  • Microwave heating system of KSTAR consists of ECH and LHCD. ECH and LHCD offer the reliability of operation in the beginning of plasma formation and non-inductive current drive for long time steady state operation with maintaining MHD stability, respectively. LHCD demands 5 GHz of frequency and consists of c-band waveguide, 4-port circuitor, dry dummy load, dual directional coupler, E-bend, arc detector. Our system is a lineup type pulse modulator that has 45 kV of output pulse voltage, 90 A of pulse current, 4 us of pulse width. 1:4 step-up pulse transformer, 7 stages of PFN and thyratron tube (E2V, CX1191D) are used in this modulator. The purpose of this paper is to show the modulator design and experimental result.

  • PDF

Pressure Control of a Variable Thrust Solid Propulsion System Using On-Off Controllers (On-Off 제어기를 이용한 가변추력 고체추진 기관의 압력제어)

  • Kwon, Soon-Kyu;Kim, Young-Seok;Ko, Sang-Ho;Suh, Seok-Hoon
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.942-948
    • /
    • 2011
  • Solid propulsion systems have simple structures compared to other propulsion systems and are suitable for long-term storage. However the systems generally have limits on control of thrust levels. In this paper we introduce controllers for combustion chamber pressure using on-off control techniques which have been known for relatively easy implementation and energy efficiency. For this, we use a simple pressure change model by considering only mass conservation within the combustion chamber and we design a classical controllers and on-off controllers with are Pulse Width Modulation(PWM) and Pulse Width Pulse Frequency Modulation (PWPFM). Then we compare the performance results of the controllers through numerical simulations.

  • PDF

Effects of 10 % Lidocaine Spray and Aroma Hand Massage on Pain, Anxiety, Blood Pressure, and Pulse During Arteriovenous Fistula Needling in Hemodialysis Patients (10% 리도카인 분무와 아로마 손 마사지가 혈액투석 동정맥루 천자 시의 통증, 불안, 혈압 및 맥박에 미치는 효과)

  • Song, Ji Mi;Park, Hye-Ja
    • The Korean Journal of Rehabilitation Nursing
    • /
    • v.19 no.1
    • /
    • pp.1-11
    • /
    • 2016
  • Purpose: To determine the effects of 10 % lidocaine spray and aroma hand massage on pain, anxiety, blood pressure, and pulse during arteriovenous (AV) fistula needling in hemodialysis (HD) patients. Methods: This study used a quasi-experimental design. Forty HD patients were assigned to either 10 % lidocaine spray group (n=21) or aroma massage group (n=19). 10 % lidocaine was sprayed 3 times around AV fistula 10 minutes before. Aroma hand massage was performed for 5 minutes with fluids containing 2 % of lavender, peppermint, and geranium concentrate mixture. Pain, anxiety, blood pressure, and pulse were measured during AV fistula needling without any intervention on the first week and during interventions on the second week. Data were analyzed with ${\chi}^2$ test, Fisher's exact test, t-test, paired t-test and MANCOVA. Results: Pain and anxiety were significantly decreased in both the lidocaine spray group and aroma massage group. Aroma hand massage was more effective to reduce pulse during AV fistula needling. Conclusion: The results suggest that 10% lidocaine spray and aroma hand massage may be effective to reduce pain, anxiety, and pulse during AV fistula needling in HD patients.

UWB Pulse Generation Method for the FCC Emission Mask (FCC 방출 전력 마스크에 적합한 UWB 펄스 생성 방법)

  • Park, Jang-Woo;Cho, Sung-Eon;Cho, Kyung-Ryong
    • Journal of Advanced Navigation Technology
    • /
    • v.10 no.4
    • /
    • pp.333-341
    • /
    • 2006
  • This paper analyzes the spectral power properties of various time hopping UWB signals and shows that the power spectral densities of the various signals could have to be determined by the PSD of the pulse used in the signal. The pulse design method by which the FCC emission mask can be utilized fully is proposed. The method combines the arbitrary derivative Gaussian pulse linearly. The coefficients of the linear combination are calculated by the LSE(Least Square Error) method. Various parameters such as the number of coefficients and the types of the basic pulses are considered when calculating the PSD and pulse shapes of the new pulses.

  • PDF

Design and Response Analysis of Wideband Monopulse Radar System Robust to Noise Jamming Signal (잡음 재밍 신호에 강인한 광대역 모노펄스 레이더 시스템 설계 및 응답 특성 분석)

  • Shin, Bohun;Yang, Haejoon;Kim, Changyeol;Park, Soryoung;Noh, Sanguk;Nam, Ilku
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.94-102
    • /
    • 2018
  • In this paper, the wideband mono-pulse radar using AGC and limiter is designed. The output response characteristics of the mono-pulse radar using AGC and limiter are analyzed, respectively. In addition, the output response for jamming input signals is analyzed. The range tracking loop in the mono-pulse radar has robust output response to the noise jamming input signal. Although the output settling response of the AGC-based mono-pulse radar is larger than that of the limiter-based mono-pulse radar, the AGC-based mono-pulse radar has robustness to the noise jamming input signal due to feedback loop.

Effects of San-Yin-Jiao (SP6) Acupressure on Anxiety, Pulse and Neonatal Status in Women during Labor (삼음교(SP6) 지압이 산부의 불안, 맥박 및 신생아 상태에 미치는 효과)

  • Lee, Mi-Kyeong
    • Women's Health Nursing
    • /
    • v.9 no.2
    • /
    • pp.138-151
    • /
    • 2003
  • Purpose: In the study effects of San-Yin-Jiao (SP6) acupressure on anxiety and pulse during labor, and on neonatal status were examined. Method: The design was a randomized controlled clinical trial with a double-blind method. Data were collected before (pre) and after (post) treatment using structured questionnaire, anxiety scale, pulse rate, umbilical vein pH and Apgar scores. The experimental group received SP6 acupressure for the duration of each uterine contraction over a period of 30 minutes, but the control group received SP6 touch. Results: The anxiety scores between the two groups increased, but the increase was less in the SP6 acupressure group and the difference was statistically significant (p=0.019). Maternal pulse rate was not significantly different immediately after treatment (p=0.711), at 30 and at 60 minutes (p=0.140 ; p=0.108), but while the SP6 acupressure group had a stable pulse, the SP6 touch group showed an increased rate. There was no significant difference between the two groups for umbilical vein pH (p=0.124), and neonatal Apgar score at one and five minutes (p=0.387 ; p=0.979). Conclusion: These findings strengthen the belief that SP-6 acupressure can be used to relieve anxiety during labor with no side effects to either mother or baby.

  • PDF

An Experimental Study on the Heat Exchangers in the Pulse Tube Refrigerator (맥동관 냉동기 열교환기에 관한 실험적 연구)

  • 남관우;정상권;정은수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.3
    • /
    • pp.284-291
    • /
    • 2000
  • A basic pulse tube refrigerator has been constructed with extensive instrumentation to study the characteristics of the heat exchanger experimentally under the oscillating pressure and the oscillating flow. This paper describes the sequential experiments with the basic pulse tube refrigerator. The experiments were performed for various cycle frequencies under the square pressure wave forms. First, the heat flux was measured through the cycle at the both cold and warm end heat exchangers without the regenerator. In order to enhance the thermal communication capability of the heat exchanger with the gas at low operating frequencies, a unique design of the triangular shape radial fin concept was applied to the heat exchangers. For the fin heat exchanger, the measured heat flux and the calculated heat flux from the two well-known oscillating heat transfer correlations were compared and discussed. Second, the regenerator was added to the pulse tube to make a basic pulse tube refrigerator configuration. The experiment showed the great impact of the regenerator on the temperature and the heat flux profiles. At the warm-end, the cyclic averaged heat flux had its maximum value at the specific operating frequency. The paper presents the explanation of the surface heat pumping effect as well as the experimental data.

  • PDF

Effects of Types of Music in Music Therapy on Anxiety and Vital signs of Surgical Patients Undergoing Operation Using Spinal Anesthesia (음악요법 유형이 척추마취 수술환자의 수술 중 불안 및 활력징후에 미치는 영향)

  • Kim, Yeoun-Ok;Kim, Joo-Hyun
    • Journal of Korean Biological Nursing Science
    • /
    • v.13 no.2
    • /
    • pp.149-155
    • /
    • 2011
  • Purpose: The purpose of this research is to examine types of music (relax music or preferred music that patients have chosen) can effects on anxiety, blood pressure and pulse, and whether there are differences depending on the kinds of music in order to reduce anxiety of surgical patients using spinal anesthesia. Methods: This research's design is quasi-experimental design and non-equivalent control group pretest-posttest experimental design conducted on 60 surgical patients(experimental group 1=relax music therapy group, experimental group 2=preferred music therapy group, and group 3=control group) using spinal anesthesia. The Variables were trait anxiety, state anxiety, blood pressure, and pulse. Results: 1) In the state anxiety, there was a significant difference among the experimental groups 1, group 2 and the control group. 2) There was a significant difference in systolic blood pressure among the experimental group 1, group 2, and the control group. 3) In pulse, no significant difference among the experimental group 1, group 2 and the control group was detected. Conclusion: Regardless of the types of music, music therapy is thought to be effective nursing mediation to mitigate the state anxiety of surgical patients undergoing spinal anesthesia.