• 제목/요약/키워드: Pulse design

검색결과 1,439건 처리시간 0.032초

Microprocessor Embedded 2-Axis Motor Control Chip의 설계 (Design of Microprocessor Embedded 2-Axis Motor Control Chip)

  • 노규진;최성혁;원종백;김종은;박종식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.193-196
    • /
    • 2001
  • In this paper we designed CAMC-SP, the microprocessor embedded 2-axis motor control chip which controls a precise pulse motor by generating the pulse needed to control step motor, DC servo and AC servo motor. This design enables to decrease costs and to minimize a size. First we designed risc type 8-bit microprocessor compatible with PIC16C84, second we designed pulse motor controller. CAMC-SP is integrated of those two block. We designed CAMC-SP by VHDL and we testified to the Performance of it by performing functional simulation.

  • PDF

펄스 옥시미터의 동잡음 제거 필터 설계 (Design of an Adaptive Noise Canceller for the Motion Artifact Removal of a Pulse Oximetry Signal)

  • 김도영;김일환
    • 산업기술연구
    • /
    • 제26권A호
    • /
    • pp.89-93
    • /
    • 2006
  • Pulse oximetry, which monitors non-invasively the oxygen saturation in blood, is influenced by patient's respiration, movement or a factor of an environment. Specially, it's difficult to measure a PPG (Photoplethsmography) signal from the moving patient because of the motion artifact. Accordingly, it is required to extract the pure PPG signal from the PPG signal to measure oxygen saturation. In this paper, we propose an adaptive noise canceller to improve the performance of motion artifact removal. Then we design a hardware system for real time monitoring of the oxygen saturation. The proposed algorithm estimates the slope of transition rate between two different wavelength signals.

  • PDF

고 에너지 밀도 펄스 변압기 설계 (Design of A High Energy Density Pulse Transformer)

  • 남상훈;박성수;하기만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2186-2188
    • /
    • 1999
  • A high frequency and energy density pulse transformer is a critical component of a high voltage power supply in a traveling wave tube (TWT) amplifier system. In this paper, processes of design, manufacturing, and test of the transformer are discussed. Primary voltage of the transformer is 240 V. The transformer secondary have two outputs which are 4100 V (Helix) and 2050 V (Collector). Total output power is 860 W. Normal operating frequency of the transformer is 10 kHz. In high energy density pulse transformers, temperature rise is a main problem during its operation. From our study, it was found that resonant current due to leakage inductance and stray capacitance was the main cause of temperature rise. This happens because of the inherently high turn-ratio in high voltage transformers. Solutions to reduce stray components are presented.

  • PDF

Bar 성형 코일을 이용한 전자기 성형에 관한 기초 연구 (A Fundamental Study on Magnetic Pulse Forming with Bar Forming Coil)

  • 심지연;강봉용;박동환;김일수
    • 한국생산제조학회지
    • /
    • 제20권3호
    • /
    • pp.292-297
    • /
    • 2011
  • MPF(Magnetic pulse forming) process refers to the high velocity and high strain rate deformation of a low-ductility materials driven by electromagnetic forces that are generated by the rapid discharge current through forming coil. The goal of this study was to find the characteristics of dynamic behavior of workpiece and to find the main design process on MPF using bar forming coil. For these purposes, thin Al5053 sheet were used for the experiment. The measured strain data were analyzed by developed electromagnetic FE-model. The main design parameter is location of coil, electromagnetic force. In case of the bar forming coil, there exists the dead regions where the low electromagnetic force applied on the workpiece.

진공스위치 트리거 발생기 설계에 관한연구 (A study on the design of triggering pulse generator for the triggered vacuum switch)

  • 김무상;손윤규;박웅화;이병준
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.201.2-201.2
    • /
    • 2016
  • The triggered vacuum switch (TVS) is widely used as a high power switch in the field of pulsed power application. TVS can produce current of higher than 100 kA within a microsecond after being triggered. A triggering high voltage pulse generator supplies a high voltage signal to the trigger system to initiate the discharge between a trigger pin and one of main electrode. The trigger system, which consists of a tungsten trigger electrode and cylindrical ceramic insulator around it, is normally installed at the center of main cathode electrode. The discharging characteristics of the trigger system strongly depend on the geometry, electrode material, vacuum pressure and so on. In addition, we especially will focus on the developing a triggering pulse generator, which can vary not only value of voltage but also pulse duration, because its properties gives pivot influences on the TVS discharge. To verify such effects, we made a 3.3 kJ TVS set-up initially. Thus we will discuss some of prominent results from 3.3 kJ TVS system. In parallel we will show on the design of 300 kJ TVS system for the high current in the future.

  • PDF

펄스 충실도 개선을 위한 UWB 안테나 설계기법 연구 (A study on the UWB Antenna Design Techniques for Improving Pulse Fidelity)

  • 김종민;강은균
    • 전자공학회논문지
    • /
    • 제50권8호
    • /
    • pp.299-307
    • /
    • 2013
  • 본 논문에서는 임펄스 방사를 위한 UWB 안테나를 펄스 충실도 및 왜곡율 수식을 유도하고 적용하여 펄스 충실도가 개선된 안테나를 설계하는 방법에 대해 연구하였다. UWB 대역에서 지향성 특성을 갖는 안테나는 낮은 방사손실과, 임펄스 방사왜곡이 최소이어야 한다. 이를 위하여 광대역 임피던스 변환기와 마이크로스트립 슬롯라인 천이부 구조를 갖는 안테나 급전부를 설계하였다. 설계 및 제작된 UWB 안테나는 전파 무반사실에서 방사패턴을 측정하였다. 제작된 UWB 안테나의 임펄스 방사에 의한 펄스충실도는 ${\pm}30^{\circ}$ 빔폭내에서 93%이상의 개선된 결과를 얻었다.

A Multi-megawatt Long Pulse Ion Source of Neutral Beam Injector for the KSTAR

  • Chang, Doo-Hee;Seo, Chang-Seog;Jeong, Seung-Ho;Oh, Byung-Hoon;Lee, Kwang-Won;Kim, Jin-Choon
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 2004년도 추계학술발표회 발표논문집
    • /
    • pp.719-720
    • /
    • 2004
  • A multi-megawatt long pulse ion source (LPIS) of neutral beam injector was developed for the KSTAR. Beam extraction experiments of the LPIS were carried out at the neutral beam test stand (NBTS). Design requirements for the ion source were 120 kV/65 A deuterium beam and a 300 s pulse length. A maximum ion density of $9.1310^{11}$ $cm^{-3}$ was measured by using electric probes, and an optimum arc efficiency of 0.46 A/kW was estimated with ion saturation current of the probes, arc power, and total beam area. An arcing problem, caused by the structural defect of decelerating grid supporter, in the third gap was solved by the blocking of backstream ion particles, originated from the plasma in the neutralizer duct, through the unnecessary spaces on the side of grid supporter. A maximum drain power of 1.5 MW (i.e. 70 kV/21 A) with hydrogen was measured for a pulse duration of 0.5 s. Optimum beam perveance was ranged from 0.75 to 0.85. An improved design of accelerator for the effective control of beam particle trajectory should provide higher beam perveance.

  • PDF

유도전압합성기를 이용한 고전압 펄스발생기 설계 (Induction Voltage Adder for High Power Pulse Generator)

  • 양종원;신진우;류한용;허훈;이우상;김창구;남상훈;소준호
    • 한국군사과학기술학회지
    • /
    • 제16권5호
    • /
    • pp.703-711
    • /
    • 2013
  • In this paper, we have proposed high power generator with Induction Voltage Adder of three cells. IVA which has n cells can generate n-th times high power pulse, is a more stable system than Marx generator in the view of breakdown. We applied amorphous metal magnetic cores as an energy storing material for IVA rather than ferrite cores because of their higher magnetic flux swing to make it more compact system and the loss of it was also considered in the design. For driving the IVA, we design Blumlein pulse generators which are filled with pure water for high dielectric constant and high breakdown field strength, and triggered by single Marx generator. We have presented the PSPICE simulation and its test result.

LED TV 백라이트 소비전력 저감을 위한 스마트 디밍 알고리즘 개발 (Smart Dimming Control Algorithm for Reducing Power Consumption of LED TV Backlight)

  • 류제승;박주희;임성호;김태우
    • 전력전자학회논문지
    • /
    • 제19권4호
    • /
    • pp.320-326
    • /
    • 2014
  • In this paper, the new smart dimming algorithm which is mixed with PWM and PAM control method is proposed for reducing the power consumption of LED TV Backlight. The proposed technique is using the curve characteristics of LED forward voltage and current which is proportionally changing LED forward voltage as changing LED forward current. Therefore, each PWM and PAM control method has different LED forward voltage and current in the same brightness condition. The PWM control method adjusts the brightness of LED TV Backlight by only varying the duty ratio of PWM and constantly sustaining the amplitude of LED forward current and voltage. So, the level of LED forward current and voltage in the PWM control method is relatively high and constant regardless of duty ratio of PWM. On the other hand, the PAM control method adjusts the brightness of LED TV Backlight by directly varying the level of LED forward current. So, the level of LED forward current and voltage in the PAM control method is lowered according to the brightness level. For the above-mentioned reason, the PAM control method has the advantage of reducing the total power consumption of LED TV Backlight at the brightness condition of below 100%, compared with PWM control method. By implementing this characteristic to LED driver circuit with control algorithm in MCU, the power consumption of LED TV Backlight can expect to be reduced. The effectiveness of the proposed method, new smart dimming algorithm, CPWAM(=Conditional Pulse Width Amplitude Modulation), has been verified by experimental results.

고령자의 맥상 특성에 대한 맥파분석적인 연구 (Study on the character of the old aged pulsation)

  • 김경철;이정원;류경호;강희정
    • 대한한의진단학회지
    • /
    • 제12권2호
    • /
    • pp.1-7
    • /
    • 2008
  • Objectives: The basis research of aged people's healthcare technology is very important, because our nation goes into an aged society rapidly. Especially in traditional medicine, pulse shapes of aged people were supposed to weak and empty pulse until now, but any objective measurement and compare research do not taken. Methods and Results: Therefore in this study we design observation study to find characteristic of pulse between younger group (age $20{\sim}30$) and elder group (age $43{\sim}80$) in Busan area. We used 3-dimensional pulse analyzer '3-D MAC' (Daeyomedi Co., Ltd.). And major parameters for comparison are 1) pulse height (h1), 2) applied pressure, 3) pulse power (energy), 4) high pressure duration (w) and 5) R-AI. Conclusions: According to analysis result, elder people's pulse has more large value in pulse height, applied pressure and pulse power than younger's that. It reveals that elder people in modernized lifestyle has Yang symptoms as well Yin symptoms. Consequently we need new method to care elder people's health, and this means more important direction than old text book. From now on verification research with objective diagnosis device like 3-D MAC, must be activated to build of evidence in traditional medicine. Cause traditional medicine's spirit of care and prevention is suitable to care elder people's cardiac and cerebral vascular disease those are have close relation with elder people.

  • PDF