• 제목/요약/키워드: Pulse condition

Search Result 779, Processing Time 0.029 seconds

Study on Classification of Pulse Condition of the Chronological Medical Practitioners (역대의가(歷代醫家)의 맥상(脈象) 분석(分類)에 대한 연구)

  • Park, Jae-Won;Kim, Byung-Soo;Kang, Jung-Soo
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.22 no.6
    • /
    • pp.1347-1353
    • /
    • 2008
  • Pulse condition is the essential division for conducting pulse diagnosis which is one of the most fundamental and important diagnostics in traditional Korean/Chinese medicine. We studied the pulse condition referred to classics of traditional medicine for a full understanding in present time and come to a conclusion like below. The reference to pulse condition was concluded to 'twenty four pulse conditions' which is the fundamental conception generally accepted in present age since it had first mentioned in "Huangdi Neijing" and after it had passed through "Nanjing", "pulse pattern identification-chapter of normal pulse"of Zhang Zhongjing and reached "Maijing"of Wang Shuhe. Although medical partitioners had different views to some extent about pulse condition, there were no significant differences in the main theoretical frame. Even though there had been a diversity of opinions on the classification of pulse-condition between various medical practitioners, the method of Dae-dae and the method of systematic endeavored by Zhou Xueting and Zhou Xuehai who were medical scholars in the Ch'ing dynasty have been a criterion for the classification of pulse-condition up to date. We were able to recognize that the change of pulse condition caused by pathological situation should be compared to physiological pulse condition for detecting the deficiency and excess by researching the analyzing methods of pulse condition mentioned in the "Lingshu", and the book of Hua Shou and Zhou Xuehai). To sum up, first normal pulse which is the physiological pulse condition should be a standard for detecting physiological pulse condition. Secondly, Zhou Xueting insisted that relaxed pulse should be a standard pulse condition for detecting normal pulse.

A Study on Pulse Condition of Sameumsamyang(三陰三陽) in "Hwangjenaegyeong(黃帝內經)" ("황제내경(黃帝內經)"의 삼음삼양(三陰三陽) 맥상(脈象)에 대한 소고(小考))

  • Baik, You-Sang
    • Journal of Korean Medical classics
    • /
    • v.21 no.3
    • /
    • pp.119-125
    • /
    • 2008
  • Among the various pulse diagnosis contents in "Hwangjenaegyeong(黃帝內經)", we researched the pulse conditions that are belonged to Sameumsamyang(三陰三陽), and made a comparative study with pulse conditions of five organs[五臟], that of six meridians in "Sanghallon(傷寒論)". So from now on, this study would make help to understand standard pulse condition of Sameumsamyang(三陰三陽) diseases for clinical application. In "Hwangjenaegyeong(黃帝內經)", pulse condition of Taeyang(太陽) is expressed to be floating, Yangmyeong(陽明)'s condition to be strong but with a little bit weakness, Soyang(少陽)'s condition to be intermediate between Eum(陰) and Yang(陽), Taeeum(太陰)'s condition to be low and soft, So-eum(少陰)'s condition to be low and weak with some occasional upward tendency, Gweoleum(厥陰)'s condition to be mixed state of Eum and Yang.

  • PDF

Comparative Study of Speed, Size and Depth of Pulse on the Traditional Pulse Diagnosis and Pulse Analyzer (맥의 빠르기, 크기, 깊이에 관한 전통맥진과 기기측정 맥진의 비교 연구)

  • Ha, In-Young;Youn, Yeo-Chung;Youn, Dae-Hwan;Choi, Chan-Hun;Lee, Young-Su;Lim, Seung-Il;Na, Chang-Su
    • Korean Journal of Acupuncture
    • /
    • v.28 no.1
    • /
    • pp.23-37
    • /
    • 2011
  • Objectives : The pulse diagnosis is an important method in Oriental Medicine. The aim of this study is to measure the similarity of the diagnosis by a traditional method using doctor's hand for feeling of pulse and by pulse diagnosis apparatus using Hwang-Je (HJ) pulse analyser, Hui-Su (HS) pulse analyser on Chon, Kwan and Chuk. Methods : Four korean medical doctors and HJ pulse analyser, HS pulse analyser have measured the speed (遲數), the size (微細弱緩大), and the depth (浮沈) of pulse waves of 23 volunteers. First, four korean medical doctors measured pulse waves of volunteers. And then, the pulse waves of volunteers were measured by HJ pulse analyser, HS pulse analyser. This was performed on the right Chon, Kwan and Chuk. Results : The traditional method and the HJ pulse analyser method had the 60.9% matches on the values of the pulse speed condition, the HS pulse analyser method had the 78.3% matches on the values of the pulse speed condition. The traditional method and the HJ pulse analyser method had the 56.5% (Chon), 65.2% (Kwan), 78.3% (Chuk) matches on the values of the pulse size condition, the HS pulse analyser method had the 65.2% (Chon), 13.0% (Kwan), 39.1% (Chuk) matches on the values of the pulse size condition. The traditional method and the HJ pulse analyser method had the 43.5% (Chon), 26.1% (Kwan), 47.8% (Chuk) matches on the values of the pulse depth condition, the HS pulse analyser method had the 45.5% (Chon), 30.4% (Kwan), 36.8% (Chuk) matches on the values of the pulse depth condition. Conclusions : According to these results, we suggest that the pulse analyser is necessary to develope for its high similarities with the traditional pulse diagnosis.

The Methodic Study on a Standard of Classification of Pulse Condition -a Focus of ${\ulcorner}$The Pulse Studies of Bin-Ho(瀕湖脈學)${\lrcorner}$- (맥상 분류 기준에 대한 방법론적 고찰 - "빈호맥학(瀕湖脈學)"을 중심으로 -)

  • Lee, Ju-Ho;Choi, Hwan-Soo;Kim, Chul-Jung
    • Korean Journal of Oriental Medicine
    • /
    • v.10 no.1
    • /
    • pp.49-61
    • /
    • 2004
  • The Standardization of terms in The Pulse studies(脈學) is a need for development of learning. This study, for the correction of existing misused terms in The Pulse studies, we study on modernly and objectively the terms in The Pulse studies. By a focus of ${\ulcorner}$The Pulse Studies of Bin-Ho(瀕湖脈學)${\lrcorner}$, we studies on the new classification of pulse condition. The error of a existing technical books on Pulse studies begin that the classification of pulse condition is not establish a Standardization. For the correction of existing misused terms in The Pulse studies, we study on the pulse condition is expressed objectively a blood vessel that it is a subject of pulse condition. The expression of blood vessel contain a depth of blood vessel, a speed of pulsation, a curve of blood vessel, thickness of blood vessel, a diameter of blood vessel in expand and contract of blood vessel, a interval in expand and contract of blood vessel, a distinctness on a boundary of blood vessel, a speed of blood flow in blood vessel, a volume of blood flow in blood vessel, a condition of blood in blood vessel, a propelling power of blood vessel. These is standard of the new classification of pulse condition.

  • PDF

A study in Mack-Gyung(脈經) on taking pulse of relative weight to five Viscera attachment system in Nan-Gyung(難經) (난경(難經)에서 안맥(按脈)의 경중(輕重)에 따른 오장배속방법(五臟配屬方法)에 대(對)한 맥경(脈經)과의 비교(比較) 연구(硏究))

  • Nam, Doo-Yeul;Kim, Tae-Hee
    • The Journal of Internal Korean Medicine
    • /
    • v.13 no.1
    • /
    • pp.61-69
    • /
    • 1992
  • In Nan-Gyung, showed that could know the lung condition taking pulse with the weight of three beans, the heart condition taking pulse with the weight of six beans, the spleen condition taking pulse with the weight of nine beans, the liver condition taking pulse with the weight of twelve beans, the kidney condition pressing to bone(骨). This theory is first suggested in Nan-Gyung(難經). In those case, the weight of three, six, nine, twelve beans and pressing to bone don't mean not the real weight but the relative weight(輕重) of taking pulse(按脈). In other words, those represent Boo Jung Chin(浮中沈), which are the conception of the upper, the meddle, the lower part(上中下). So, we could take pulse of the heart and the lung condition in Boo(浮), the spleen condition in Jung(中), and the liver and the kidney condition in Chim(沈). The heart and the lung pulse showed in the Boo(float level) must be seen with Boo-Mack(부맥 : float pulse), the liver and the kidney pulse showed in Chim (sinklevel) must be seen also with Chin-Mack(沈脈 : sink pulse). The result of the method of taking pulse of viscera with relative weight focused on the as pect of mornal pulse(平脈) and disease pulse(病脈) of five viscera in Mack-Gyung publeshed later than Nan-Gyung and special works which made a comprehensive survey the result is as follow. 1. In normal pulse of five viscera, the heart and the lunk pulse were shown with Boo-Mack(浮脈:float pulse) as the central figure, the liver's and the kidney's pulse were shown centering around Chim-Mack(沈脈: sink pulse) and the spleen's pulse was shown with Wan-Mack(緩脈) which is vital force of stomach(胃氣) and seen in only middle part. 2. In disease pulse of five viscera, frequently, the heart and the lung pulse was shown as Chim-Mack(sink pulse), the liver and the kidney pulse was seen as Boo-Mack (float pulse). 3. In the case of normal pulse. the method of taking pulse with relative weight in Nan-Gyung agree with the normal pulse of five viscera in Mack-Gyung. But in the case of disease pulse, they didn't correspond with the other. 4. So the method of taking pulse with relative weight in Nan-Gyung is not the exam pulse which ca be used in the clinical diagnosis but one of the feeling pulse way to bring in the conception of location of the visceras. 5. From now on, the method of taking pulse rdlated to relative weight need to be looked into minutely compared with later physician's theory than Mack-Gyung.

  • PDF

A Study on Pulse Condition Appeared at Classic with Pulse Condition by Electro Pulse Machine (I) (전자맥진기(電子脈診器)의 맥상(脈狀)과 고전(古典)의 제맥체상(諸脈體狀)에 관한 연구(硏究)(I))

  • Kim, Seog-Ha;Hong, Sub-Hee;Jung, Hyun-Jung;Park, Won-Hwan
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.13 no.1
    • /
    • pp.36-44
    • /
    • 2009
  • Object : Pulse feeling(脈診) belongs to pulse feeling or palpation(切診) of methods of diagnosis in oriental medical terminology. Pulse appears at bio-energy condition of body, so it is a important part of disease diagnosis but we have been trouble in diagnosis by difficulty of pulse feeling(脈診). Methods : We investigate the books about pulse feeling, which are involved "Hwangjenaegyong", "Nangyong", "Maggyeng" etc. Conclusion : According to these, this paper helps you understand pulse feeling(脈診) through comparision and studying pulse condition at clasics with electro pulse machine.

  • PDF

The study of non-contact/non-invasive pulse analyzing system using Optical Coherence Tomography (OCT) for oriental pulse diagnosis (비접촉식 광생체단층촬영 기술을 이용한 맥진 연구 -맥의 빠르기, 크기 및 맥력을 중심으로-)

  • Na, Chang-Su;Youn, Dae-Hwan;Kim, Young-Sun;Lee, Chang-Ho;Jung, Woon-Sang;Kim, Jee-Hyun;Choi, Chan-Hun
    • Korean Journal of Acupuncture
    • /
    • v.26 no.2
    • /
    • pp.1-13
    • /
    • 2009
  • Objective: Optical Coherence Tomography (OCT) has emerged as an important optical imaging modality in non-invasive medical diagnostics. Hence, the aim of this study is to measure the similarity of the diagnosis by a traditional method using doctor's hand for feeling of pulse and by the non-contact/non-invasive pulse analyzing system using OCT on Chon(寸), Kwan(關), Chuk(尺). Method: Four korean medical doctors and the non-contact/non-invasive pulse analyzing system using OCT have measured the rapidity, the dimension, and the power of pulse waves of 25 volunteers. First, four korean medical doctors measured pulse waves of volunteers. During measuring, four doctors were separated from each other and so were volunteers. And then, the pulse waves of volunteers were measured by OCT. This was performed on the right Chon(寸), Kwan(關), Chuk(尺). Results: The study showed that the traditional method and the OCT based method had the 88% matches on the values of the slow and rapid pulse condition (遲數), 64% matches on the values of the small and big pulse condition(微細弱緩大[洪]), and 72% matches on the values of the weak and strong pulse condition(虛實). Conclusions: Based on the high similarities of the measurements of two approaches, we suggest that the OCT based pulse diagnosis method is useful for compensating the traditional method for the pulse diagnosis.

  • PDF

A Study on the Way of Pulse-diagnosis by Dongeuibogam (동의보감(東醫寶鑑)중 맥법(脈法)에 관한 연구(硏究))

  • Joo, Shin-Tak;Kim, Jung-Guk;Park, Won-Hwan
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.15 no.1
    • /
    • pp.1-28
    • /
    • 2011
  • Objectives: A study on the importance and consistency of pulse-daignosis in the Dongeuibogam Methods: We used Deyeuk Dongeuibogam of Dongeuibogam publishing company from original photographic edition. Results: The frequency of 27 mek (pulse condition) in Dongeuibogam is as in the following. Bumek (Floating pulse) appeared 120(8.9%) times, wanmek (moderate pulse) appeared 28(2%) times, chokmek (running pulse) appeared 7 (0.5%) times, gyumek (hollow pulse) appeared 19 (1.4%) times, saekmek (uneven pulse) appeared 33 (2.4%) times, sapmek (uneven pulse) appeared 51 (3.8%) times, kyulmek (knotted pulse) appeared 18 (1.3%) times, whalmek (slippery pulse) appeared 69 (5.1%) times, chimek (slow pulse) appeared 43 (3.2%) times, demek (intermittent pulse) appeared 13 (1%) times, silmek (replete pulse) appeared 45 (3.3%) times, bokmek (deep-sited pulse) appeared 29 (2.1%) times, neomek (firm pulse) appeared 4 (0.3%) times, hyunmek (taut pulse) appeared 110 (8.1%) times, yumek (soft pulse) appeared 20 (1.5%) times, dongmek (short and rapid pulse) appeared 16 (1.2%) times, kinmek (tense pulse) appeared 67 (5%) times, yakmek (weak pulse) appeared 46 (3.4%) times, semek (thready pulse) appeared 62 (4.6%) times, hongmek (full pulse) appeared 50 (3.7%) times, jangmek (long pulse) appeared 14 (1%) times, sakmek (rapid pulse) appeared 103 (7.6%) times, mimek (indistinctive pulse) appeared 65 (4.8%) times, danmek (short pulse) appeared 16 (1.2%) times, demek (large pulse) appeared 106 (7.9%) times, chimmek (deep pulse) appeared 112 (8.3%) times, heomek appeared 70 (5.2%) times, sanmek (scattered pulse) appeared 14(1%)times. Conclusions: We can know Donguibogam is given on the basis 27mek (pulse condition), because the frequency of 27mek (pulse condition) is high. But there are another expressions. So we can not say that Donguibogam is consistent in expressing mekbub(the way of pulse-diagnosis).

Study on the Aged-Pulse Condition and the Symptoms Index of a Disease (고령자 맥상과 병증지표 개발을 위한 기초적인 연구)

  • Kim, Gyeong-Cheol;Kim, Hoon;Shin, Soon-Shik;Lee, Hai-Woong
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.12 no.1
    • /
    • pp.149-156
    • /
    • 2008
  • In the situation providing the aged society, the contents of the symptoms of senility centering around the aged-pulse condition were arranged. The results were as follows. In the questions about the aged symptoms, the results of indicating the gradual physical-age following the aged symptoms with the real age(from 40 to 100, 7 grade) and the gradual physical-age following the ageing grade of male and female (the 3 grade of the female / the 4 grade of the male) could have the differentiations. And the distinction of the aged pulse condition was observed two pulse condition ; the one is the minute pulse condition(Mi, Sei ;微細) as lowering function and the other is the Hyun, Ghin(弦, 緊) pulse condition as the blood's tention and contration.

  • PDF

Experimental Study on Optimum Pulse Jet Cleaning Conditions of a Cartridge Filter System (카트리지 필터 여과집진기 충격기류시스템의 최적탈진조건에 관한 실험적 연구)

  • Piao, Cheng Xu;Ha, Hyun Chul;Kim, Sung Joon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.4
    • /
    • pp.542-553
    • /
    • 2015
  • Objectives: Many types of dust collector are used for industrial ventilation, with the most common types being the cylinder bag filter system, rectangular bag filter system and cylinder type cartridge filter system. The cylinder type cartridge bag filter, which has more filtering area than other types of bag filter, can increase the pulse time and extend the useful life of the filter. This can save operational costs and installation area. Materials: This study used cylinder type cartridge bag filter equipment and tested the impact of vibration level and filter pressure with different pulse jet cleaning conditions. The final, cleaning efficiency was calculated through input dust mass and cleaning dust mass Conclusions: Two optimum cleaning condition groups were found. The first condition group was $3kgf/cm^2$ pulse pressure, 15 cm pulse distance, 0.2 s pulse time with an H-10 type nozzle. The second condition group was $3kgf/cm^2$ pulse pressure, 15 cm pulse distance, 0.3 s pulse time with an H-10 type nozzle.