• 제목/요약/키워드: Pulse analysis system

검색결과 651건 처리시간 0.035초

새로운 일반형 블럭 펄스 적분 연산 행렬을 이용한 선형 시불변 시스템 해석 (Analysis of Linear Time-invariant System by Using a New Block Pulse Operational Matrices)

  • 이해기;김태훈
    • 전기학회논문지P
    • /
    • 제53권4호
    • /
    • pp.175-182
    • /
    • 2004
  • This paper presents a new method for finding the Block Pulse series coefficients, deriving the Block Pulse integration operational matrices and generalizing the integration operational matrices which are necessary for the control fields using the Block Pulse functions. In order to apply the Block Pulse function technique to the problems of state estimation or parameter identification more efficiently, it is necessary to find the more exact value of the Block Pulse series coefficients and integral operational matrices. This paper presents the method for improving the accuracy of the Block Pulse series coefficients and derives generalized integration operational matrix and applied the matrix to the analysis of linear time-invariant system.

비체증(鼻涕證), 해수증(咳嗽證), 효천증(哮喘證) 환자(患者)에 대한 양도락(良導絡) . 맥진검사(脈診檢査)의 진단가치(診斷價値) (The Diagnostic Values of Ryodoraku and Pulse Analysis for a portion of Respiratory Disease)

  • 심봉암;이성헌;정희재;정승기
    • 대한한방내과학회지
    • /
    • 제29권3호
    • /
    • pp.535-542
    • /
    • 2008
  • Objectives : Ryodoraku, which is a physiological function test using electric current, is closely related to skin sympathetic tone. Pulse analysis is known to reflect cardiovascular reactivity. Refer to the previous researches Ryodoraku and pulse analysis have value as tools for diagnosing respiratory diseases. In this study we examined the diagnostic values of Ryodoraku and pulse analysis for respiratory disease patients. Methods : For this study. we conducted Ryodoraku and pulse analysis on 114 people, including 83 respiratory disease outpatients and 31 volunteers who did not have any respiratory symptoms or disease history. The respiratory patients were divided into three subgroups according to their symptoms: rhinorrhea group, cough-sputum group and wheezing-dyspnea group. Then we compared the disease groups with the control group. Results : When all experimental groups were compared with the control group, mean Ryodoraku was significantly lower. Mean H2, mean H3 and mean H6 were significantly lower in the rhinorrhea group (P<0.05), all the test results of Ryodoraku were evidently lower in the cough-sputum group (P<0.01), and most results of Ryodoraku were evidently lower in the wheezing-dyspnea group except H1 (P<0.01). Compared with the control group on pulse analysis, mean YP+/YP- was significantly lower in the wheezing-dyspnea group (P<0.05). Conclusion : Ryodoraku and pulse analysis were found to have a high value as quantitative diagnosis tools reflecting individuals' weakness and firmness. Nevertheless, more research is needed to find the further values.

  • PDF

맥솔(脈率)과 심박변이도(心搏變移度)의 상관성(相關性) 연구(硏究) (Correlation between Pulse-respiration Ratio and Heart Rate Variability)

  • 양동훈;박영배
    • 대한한의진단학회지
    • /
    • 제10권2호
    • /
    • pp.104-120
    • /
    • 2006
  • Background : Pulse-respiration ratio has been used for estimating subject's status in oriental medicine. Pulse and respiration is strongly associated with autonomic nerve system. But there is no research about correlation between pulse-respiration ratio and autonomic nerve system. Objectives : We performed this study to know correlation between pulse-respiration ratio and HRV(heart rate variability) that shows autonomic nerve system status well and to clarify clinical meaning of pulse-respiration ratio. Methods : After subject's 10 minutes rest, we measured subject's ECG, respiration pattern and HRV. In this research, subject's number is 95(Male 50/Female 45). We calculated pulse-respiration ratio from ECG and respiration pattern. Then, we analyzed correlation between pulse-respiration ratio and HRV parameters in all subjects, 2 group divided by Wan-Maek(P-R ratio 4.28). We tried to compare HRV parameters among Wan-Maek, Sak-Maek and Ji-Maek group. Correlation analysis between pulse-respiration Ratio and Pulse rate, respiration rate is performed. Finally correlation analysis between Respiration and HRV parameters in all subjects, 2 group divided by Wan-Maek(4.28) is studied. Results : 1. Mean pulse-respiration is 4.10${\pm}$0.67, Mean pulse rate is 68.06${\pm}$7.82bpm, Mean respiration rate is 16.81${\pm}$2.72 times per minute in all subjects. 2. Correlation analysis between pulse-respiration ratio and HRV parameters of high pulse-respiration ratio group is not significant. But, in low pulse-respiration ratio group, HFnorm(correlation coefficient 0.306, p= 0.018), lnHF (0.308, p=0.002) is significantly correlated with pulse-respiration ratio. 3. Comparison of HRV parameters among Wan-Maek, Sak-Maek and Ji-Maek Group is not significant. 4. Pulse-respiration ratio is more affected by respiration rate(correlation coefficient-0.17, p=0.000) than pulse rate (correlation coefficient 0.396, p=0.000). 5. Correlation analysis between respiration rate and HRV parameters of high pulse-respiration ratio group is not significant. But, in low pulse-respiration ratio group, HFnorm (correlation coefficient -0.327, p=0.011), LF/HF(0.346, p=0.007), lnHF (-0.355, p=0.006) are significantly correlated with respiration rate. Conclusion : Pulse-respiration ratio and parasympathetic index has positive correlation. The closer Wan-Maek, The higher parasympathetic index in low pulse-respiration ratio group. Respiration rate is more related with pulse-respiration ratio than pulse rate. Respiration is negatively correlated with autonomic parameters. And the slower respiration, the higher parasympathetic index in low pulse-respiration ratio group.

  • PDF

Pulse ESPI System을 이용한 모형교량의 진동특성해석 (Vibration Characteristic Analysis of Bridge Simulator by Pulse ESPI System)

  • 최정구;김경석;장호섭;강명구;김성식
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1433-1437
    • /
    • 2005
  • Until now, strain gage technique and accelerometer for the diagnosis safety of constructions are used widely. However, the limits of these methods are revealed. But Electronic Speckle Pattern Interferometry(ESPI) that uses Pulse Laser is noncontact, whole-field, real-time measuring method also dull to disturbance and can achieve test result in a very short time. It has various strong point in spot application, swift establishment, and dynamic conduct analysis for the entire field of Laser illuminate. This author analyzed vibration characteristic of using the Pulse ESPI System, the diagnosis safety of bridges, to simplify the analysis of the dynamic conduct of a large construction.

  • PDF

펄스코로나 방전의 전극길이, 펄스반복율에 따른 부하 임피던스 변화 특성 및 EMTP 해석 (The EMTP Analysis and Characteristics of Load Impedance on Various Electrode length, Pulse Repetition in Pulse Corona Discharging)

  • 정종한;송우정;전진안;정현주;홍정환;김희제
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권4호
    • /
    • pp.158-163
    • /
    • 2002
  • The pulsed Power system has been widely used to many applications, such as E/P(Electrostatic Precipitator), DeNOx/DeSOx power system, often generator, etc. In this paper, we study EMTP analysis and characteristics of critical voltage and load in impedance on various electrode length of pulse corona. To obtain a stable pulse voltage, we designed a compact pulse generator switched MOSFET and tested their characteristics by adjusting electrode length and pulse repetition. As a re sult, critical voltage of pulse corona and load impedance on increasing electrode length were decreased. These results indicate we can control critical voltage of pulse corona and suppress arc discharging between two electrodes.

웹기반 임상 맥파 데이터 분석 시스템에 관한 연구 (The Study on the Web-Based Analysis System of Oriental Pulse Waveform)

  • 이준영
    • 전기학회논문지P
    • /
    • 제61권1호
    • /
    • pp.9-12
    • /
    • 2012
  • This paper analyzes a web-based clinical management system and conducts research on the pulse. Pulse analysis and the clinical study management system proposed by the web-based research holds significance in that it improves the objectivity and accuracy of pulse diagnosis. In particular, exact data must be analyzed through the clinical interpretation of these studies. Eventually oriental pulse standardization work will be continuously sustained. The findings of this study will help achieve remote diagnosis and consultation and updating of database. Research must be expanded to the development of telemedicine technology to create u-Health that will lead this present era.

부분방정 측정에서 센서 및 펄스 분석 알고리즘에 따른 노이즈 제거 연구 (A Study of the Noise Discrimination by use of Different Sensors and Pulse Analysis Algorithms in Measuring Partial Discharge)

  • 김지홍;구자윤;김정태
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권4호
    • /
    • pp.183-188
    • /
    • 2006
  • Abstract - In order to investigate the possibility of separating PD(partial discharge) and noises through the pulse analysis by use of a HFCT, pulse shapes measured by a resistive sensor and a HFCT were analyzed and adequate PA(pulse analysis) algorithms were studied. For the purpose, the HFPD detection and PA system has been developed. Also void discharges and air corona were adopted as the artificial defect and noises, respectively. As a result, it is possible to separate partial discharges and noises through the PA method using the $100kHz{\sim}20MHz$ frequency range HFCT. It is expected to apply the developed system to on-site PD measurements for the electric equipments.

Performance Analysis of TH-BPPM and TH-BPAM UWB System and the Applications in Data and Image Transmission

  • Sung, Tae-Kyung
    • 한국항해항만학회지
    • /
    • 제31권2호
    • /
    • pp.159-163
    • /
    • 2007
  • In this paper, we mainly analyze the performance of two ultra wideband communication systems, the classical Time Hopping Binary Pulse Position Modulation (TH-BPPM) UWB system and the Time Hopping Bipolar Pulse Amplitude Modulation (TH-BPAM) UWB system. The performance of TH-BPPM and TH-BPAM is analyzed in detail under an ideal AWGN channel and a correlation receiver. We use the power spectral density function to get the expression of BER of these two UWB systems. It yields simple and exact formulas relating the performance to the system parameters. The analysis shows that TH-BPPM suffers performance degradation with respect to TH-BPAM. Furthermore, we give the computer simulation of both data and image transmission and our simulation results also prove our theoretical analysis.

PA Map(Pulse Analysis Map)을 이용한 새로운 부분방전 패턴인식에 관한 연구 (A Study on the New Partial Discharge Pattern Analysis System used by PA Map (Pulse Analysis Map))

  • 김지홍;김정태;김진기;구자윤
    • 전기학회논문지
    • /
    • 제56권6호
    • /
    • pp.1092-1098
    • /
    • 2007
  • Since one decade, the detection of HFPD (High frequency Partial Discharge) has been proposed as one of the effective method for the diagnosis of the power component under service in power grids. As a tool for HFPD detection, Metal Foil sensor based on the embedded technology has been commercialized for mainly power cable due to its advantages. Recently, for the on-site noise discrimination, several PA (Pulse analysis) methods have been reported and the related software, such as Neural Network and Fuzzy, have been proposed to separate the PD (Partial Discharge) signals from the noises since their wave shapes are completely different from each other. On the other hand, the relevant fundamental investigation has not yet clearly made while it is reported that the effectiveness of the current methods based on PA is dependant on the types of sensors. Moreover, regarding the identification of the vital defects introducible into the Power Cable, the direct identification of the nature of defects from the PD signals through Metal Foil coupler has not yet been realized. As a trial for solving above shortcomings, different types of software have been proposed and employed without any convincing probability of identification. In this regards, our novel algorithm 'PA Map' based on the pulse analysis is suggested to identify directly the defects inside the power cable from the HFPD signals which is output of the HFCT and metal foil sensors. This method enables to discriminate the noise and then to make the data analysis related to the PD signals. For the purpose, the HFPD detection and PA (Pulse Analysis) system have been developed and then the effect of noise discrimination has been investigated by use of the artificial defects using real scale mockup. Throughout these works, our system is proved to be capable of separating the small void discharges among the very large noises such as big air corona and ground floating discharges at the on-site as well as of identifying the concerned defects.

펄스방전 확공형 앵커의 하중전이에 관한 연구 (Load Transfer on Pulsed Power Discharge Anchors)

  • 김성규;김낙경;김재원;주용선;김선주
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.832-839
    • /
    • 2010
  • The pulse discharge anchor is a method to increase the capacity of anchors using electric discharge geotechnical technologies, which is also known as pulse discharge and electric-spark technologies. The pulse discharge anchor has bulbed bond length that is expanded by high voltage electrokinetic pulse energy. 24 anchors were installed in the weathered soil and sandy clay at the Geotechnical Experimentation Site at Sungkyunkwan University in Suwon, Korea and attached strain gauge at 10 anchors. The numerical predictions by Beam-Column analysis were compared with observed measurements in a field load test.

  • PDF