• 제목/요약/키워드: Pulse amplitude

검색결과 495건 처리시간 0.038초

광용적맥파 신호를 이용한 수면 중 호흡 추정 (Estimation of Respiration Using Photoplethysmograph During Sleep)

  • 박종욱;이전;이효기;김호중;이경중
    • 대한의용생체공학회:의공학회지
    • /
    • 제34권3호
    • /
    • pp.105-110
    • /
    • 2013
  • Respiratory signal is one of the important physiological information indicating the status and function of the body. Recent studies have provided the possibility of being able to estimate the respiratory signal by using a change of PWV(pulse width variability), PRV(pulse rate variability) and PAV(pulse amplitude variability) in the PPG (photoplethysmography) signal during daily life. But, it is not clear whether the respiratory monitoring is possible even during sleep. Therefore, in this paper, we estimated the respiration from PWV, PRV and PAV of PPG signals during sleep. In addition, respiration rates of the estimated respiration signal were calculated through a time-frequency analysis, and errors between respiration rates calculated from each parameter and from reference signal were evaluated in terms of 1 sec, 10 sec and 1 min. As a result, it showed the errors in PWV(1s: $36.38{\pm}37.69$ mHz, 10s: $36.53{\pm}38.16$ mHz, 60s: $30.35{\pm}38.72$ mHz), in PRV(1s: $1.45{\pm}1.38$ mHz, 10s: $1.44{\pm}1.37$ mHz, 60s: $0.45{\pm}0.56$ mHz), and in PAV(1s: $1.05{\pm}0.81$ mHz, 10s: $1.05{\pm}0.79$ mHz, 60s: $0.56{\pm}0.93$ mHz). The errors in PRV and PAV are lower than that of PWV. Finally, we concluded that PRV and PAV are more effective than PWV in monitoring the respiration in daily life as well as during sleep.

초음파와 맥진기로 살펴본 인영맥의 세기와 경동맥의 상관 요인 연구 (Association of the Strength of Inyoung Pulse and Carotid Artery Using Ultrasonography and Pulse Diagnosis Device)

  • 송민선;이상영;최찬헌
    • 동의생리병리학회지
    • /
    • 제26권5호
    • /
    • pp.610-614
    • /
    • 2012
  • This study was done to identify correlates of carotid artery ultrasonography's measurement and Inyoung pulse in college students. We measured the amplitude of Inyoung pulse, Chongu pulse, ratio of Inyoung to Chongu and ratio of Chongu to Inyoung on 30 college students. Also, We measured the Distance, Diameter), RI(resistivity index), S/D(systolic, diastolic ratio), PI(pulsatility index), PSV(peak systolic velocity), EDV(End diastolic velocity), Vmean using carotid artery ultrasonography. The data was analyzed by Pearson's correlation coefficient using SAS program. The results were as follow. Results showed a positive correlation between Inyoung pulse and diameter by carotid artery. It showed a positive correlation between Inyoung pulse and S/D. Also, It showed a positive correlation between Inyoung pulse and PSV. As a result, the strength of Inyoung pulse related with the diameter of carotid artery and blood flow velocity.

음향탐지를 이용한 트리잉의 열화진단을 위한 정량적 분석에 관한 연구 (A Study on Quantitative Analysis for Treeing Deterioration Diagnosis Using Acoustic Detection)

  • 이덕진;신성권;김재환
    • 조명전기설비학회논문지
    • /
    • 제13권4호
    • /
    • pp.68-74
    • /
    • 1999
  • 본 연구는 고분자재료에서 음향센서를 이용한 부분방전의 음향적 탐지를 행했다. 저밀도 폴리에틸렌에 대한 트리잉파괴 실험에서 음향센서로 얻어진 음향방출 특성의 시간순서대로 측정하여 통계처리를 행했다. 또한 5가지 특성량을 도입하고 $\psi$-AEA-n(위상-음향진폭-펄스수) 패턴을 분석한 결과, 보이드 시료의 AE평균개시진폭 $(\overline{AEA_{inc}})$과 AE 평균최대진폭$(\overline{AEA_{max}})$은 열화중기, AE펄스수, AE평균최대위상각$(\overline{\theta{max}})$은 열화말기를 진단하기 위해서 유용한 음향방출량임을 알 수 있다. 이들 음향방출량은 보이드 시료의 열화진단을 구별하는데 유용한 음향방출량임을 실험결과로부터 얻었다.

  • PDF

Non-Linear dynamic pulse buckling of laminated composite curved panels

  • Keshav, Vasanth;Patel, Shuvendu N.
    • Structural Engineering and Mechanics
    • /
    • 제73권2호
    • /
    • pp.181-190
    • /
    • 2020
  • In this paper, non-linear dynamic buckling behaviour of laminated composite curved panels subjected to dynamic in-plane axial compressive loads is studied using finite element methods. The work is carried out using the finite element software ABAQUS. The curved panels are modelled with S4R element and the nonlinear dynamic equilibrium equations are solved using the ABAQUS/Explicit algorithm. The effect of aspect ratio, radius of curvature and thickness are studied. The importance of orientation of plies in the direction of loading is also reiterated in this study. Vol'mir's criterion is used to calculate the dynamic buckling loads. The panels are subjected to rectangular pulse load of various amplitude and durations and the responses are observed. For particular loading amplitude, a critical value of loading duration is observed beyond which the variation of dynamic buckling load is insignificant. It is also observed that, the value of dynamic bucking load reduces as the loading duration is increased though the reduction is not much after a particular loading duration.

Multi-Valued Image Entropy Coding for input-width reduction of LCD source drivers

  • Sasaki, Hisashi;Arai, Tooru;Hachiuma, Masayuki;Masuko, Akira;Taguchi, Takashi
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.149-152
    • /
    • 2004
  • A new joint source channel coding reduces both input-width and average current consumption to transmit image data to LCD source drivers. As a source coding, it is based on entropy coding of differential pulse code modulation scheme, especially using median edge detector of image predictor. As a channel coding, it is not a simple pulse amplitude modulation, but linked by source entropy to reduce average amplitude. Simulation results show 1/4 width is achievable by 16-valued transmission with keeping conventional current consumption (0.36 to 1.3).

  • PDF

Ultrasonic Measurement of Interfacial Layer Thickness of Sub-Quarter-Wavelength

  • Kim, No-Hyu;Lee, Sang-Soon
    • 비파괴검사학회지
    • /
    • 제23권6호
    • /
    • pp.577-582
    • /
    • 2003
  • This paper describes a new technique for thickness measurement of a very thin layer less than one-quarter of the wavelength of ultrasonic wave used in the ultrasonic pulse-echo measurements. The technique determines the thickness of a thin layer in a tapered medium from constructive interference of multiple reflection waves. The interference characteristics are derived and investigated in theoretical and experimental approaches. Modified total reflection wave g(t) defined as difference between total and first reflection waves increases in amplitude as the interfacial layer thickness decreases down to zero. A layer thickness less than one-tenth of the ultrasonic wavelength is measured using the maximum amplitude of g(t) with a good accuracy and sensitivity. The method also requires no inversion process to extract the thickness information from the waveforms of reflected waves, so that it makes possible to have the on-line thickness measurement of a thin layer such as a lubricating oil film in thrust bearings and journal bearings during manufacturing process.

광섬유 센서를 이용한 부분방전 측정연구 (A Study on Partial Discharge Measurement using Optical Fiber Sensors)

  • 이준호;이철규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.922-924
    • /
    • 1998
  • In this paper, an optical fiber sensor(OF sensor) utilizing the principal of Mach-Zehnder interferometer were proposed to detect the partial discharge signals in insulating oil. At first the AC breakdown signals were detected to check the response of the OF sensor. The detected signals from OF sensor was consistent with that from current probe. After the response checking, simultaneous measurements and continuous recording were made of electrical and the OF sensor signals from partial discharge(PD) produced by IEC(b) electrode system immersed in insulating oil. The continuous recording made it possible to extract basic quantities of PD from the OF sensor signals, such as pulse phase and pulse amplitude distribution. Through the signal analysis, the absolute peaks of the OF sensor PD signal was found to be increased with the amplitude of electrical signals, and these results mean that there is a strong correlation between OF sensor and electrical PD signals. It was demonstrated that the OF sensor in this research had a possibility to detect the PD signals in power apparatus.

  • PDF

Embodiment of Low Operating Voltage in Positive Column AC-PDPs

  • Kim, Hyun;Tae, Heung-Sik;Chien, Sung-Il
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.95-98
    • /
    • 2003
  • The positive column discharge characteristics in the long gap (440 ${\mu}m$) are investigated based on the voltage distribution among three electrodes. In particular, the effects of the amplitude and width of the short pulse applied to the address electrode on the positive column discharge characteristics are examined intensively. By proper controlling of the amplitude and width of the address short pulse, it is found that the positive column discharge in the long gap is well constructed. As a result, under the stable static voltage margin condition, the firing and sustaining voltages are as low as those of conventional short gap(60 ${\mu}m$) discharge($V _f=220V$, $V_s=150V$) and the color purity is improved. Moreover, the luminous efficiency increases up to 60% in comparison with the conventional case.

  • PDF

A Four-quadrant Analog Multiplier Based on Switched-capacitor and Pulse-Width Amplitude Modulation Techniques

  • Siripruchyanun, Montree;Wardkein, Paramote
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -2
    • /
    • pp.739-742
    • /
    • 2002
  • This article proposes a Four-Quadrant Analog Multiplier (4-QAM) applying switched-capacitor and pulse-width amplitude modulation (PWAM) principles. The features of the presented circuit are that it can function as analog multiplier with a wide dynamic range of input signal and no disturbing from deviation of carrier frequency of PWM signal. In addition, the circuit detail is simpler than that of the previously proposed circuits. It is then easy and applicable for employing it into Integrated Circuit (IC) realization to especially operate in low-frequency and low-power applications. The experimental results granted are in correspondence to the theoretical analysis.

  • PDF

초음파 영상 시스템의 Synthetic Focusing을 위한 구면파 발생 방법 (Method Generating Circular Wave for Synthetic Focusing)

  • 오진식;김정준;송태경;안영복
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.215-216
    • /
    • 1998
  • The ultrasonic imaging systems using synthetic aperture beamforming has been formed in the way that one element transmits and then receives a pulse. Because the amplitude of a pulse from one element is too small to propagate a long distance, the SNR(Signal to Noise Ratio)is low. This paper proposes the method to make a circular wave almost equal to one generated by one element using several elements. The amplitude of the wave made up of several elements is much larger than that of one element. And we can improve the SNR.

  • PDF