• Title/Summary/Keyword: Pulse amplitude

Search Result 495, Processing Time 0.031 seconds

Development of Ultrasonic Pulse Compression Using Golay Codes (Golay 코드를 사용한 초음파펄스압축법 개발)

  • Kim, Young-H.;Kim, Young-Gil;Jeong, Peter
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.3
    • /
    • pp.185-193
    • /
    • 1994
  • Conventional ultrasonic flaw detection system uses a large amplitude narrow pulse to excite a transducer. However, these systems are limited in pulse energy. An excessively large amplitude causes a dielectric breakage of the transducer, and an excessively long pulse causes decrease of the resolution. Using the pulse compression, a long pulse of pseudorandom signal can be used without sacrificing resolution by signal correlation. In the present work, the pulse compression technique was implemented into an ultrasonic system. Golay code was used as a pseudorandom signal in this system, since pair sum of autocorrelations has no sidelobe. The equivalent input pulse of the Golay code was derived to analyze the pulse compression system. Throughout the experiment, the pulse compression technique has demonstrated for its improved SNR(signal to noise ratio) by reducing the system's white noise. And the experimental data also indicated that the SNR enhancement was propotional to the square root of the code length used. The technique seems to perform particularly well with highly energy-absorbent materials such as polymers, plastics and rubbers.

  • PDF

The Effects of Sa-Am Acupuncture on Radial Pulse in Healthy Subjects: A Comparative Study of Large Intestine Tonifying and Sedating (대장정격 및 승격 자침이 정상 성인의 맥파에 미치는 영향 비교 연구)

  • Cho, Eun;Lee, Hyun
    • Journal of Acupuncture Research
    • /
    • v.31 no.3
    • /
    • pp.7-18
    • /
    • 2014
  • Objectives : The purpose of this study is to find parameters to compare the effects of Sa-Am acupuncture with large intestine tonifying and sedating on radial pulse in healthy subjects. Methods : Sixty healthy subjects participated in this study, divided into large intestine tonifying acupuncture group, large intestine sedating acupuncture group and control group. Radial pulse was measured by 3 dimensional pulse imaging system(DMP-3000) before, right after, 30 minutes after and 60 minutes after acupuncture at Cun, Guan, and Chi in the acupuncture group and in the control group at the same time points. Results : 1. Angle of main peak and magnitude of fourier component significantly changed by integrated analysis of Cun, Guan and Chi. 2. Amplitude of H1, Pulse Power volume / min, elasticity, AIx / HR, Frequency and magnitude of fourier component significantly changed by analysis of Cun, Guan, and Chi. Conclusions : The effect of Sa-Am acupuncture with large intestine tonifying and sedating in healthy human may be observed on time, amplitude, pulse area, augmentation index and fourier components parameters. The parameters analysed in this study may be used to differentiate the effects between Sa-Am acupuncture with large intestine tonifying and sedating on radial pulse. Further studies on the effects of Sa-Am acupuncture using radial pulse are needed.

Change of arterial pulse wave characteristic by measurement posture and brachial blood pressure (측정 자세 및 상완 혈압에 의한 맥파 특성 변화)

  • Nam, Ki-Chang;Kim, Eun-Gun;Hoe, Hyun;Huh, Young
    • Science of Emotion and Sensibility
    • /
    • v.12 no.3
    • /
    • pp.299-306
    • /
    • 2009
  • In this study, pulse waves were measured at radial artery using non-invasive tonometric pulse pressure measurement system, SphygmoCor(AtCor, Australia), according to subject's posture. Then it was analysed whether the pulse wave parameters, which contain heart activities, change among three different postures (upright stand, sit, and supine). And it was also verified that the pulse wave parameters change among blood pressure level groups(hypotensive, normotensive, and hypertensive). As a results, posture effects were verified in time information of pulse wave rather than amplitude. But some parameters calculated by ratio of two amplitude, such as augmented index(AI) and ratio of central aortic pulse and radial artery pulse, showed significant difference according to postures. In post hoc test, time to the $1^{st}$ and $2^{nd}$ pulse peak(P_$T_1$, and P_$T_2$), ED(ejection duration), and HR(heart rate) showed significant difference among posture groups with each other. In comparison of blood pressure groups, it was verified that the parameters related to amplitude of pulse wave showed significant difference rather than time information.

  • PDF

Single-Phase Inverter System Using New Modulation Method (새로운 변조방식을 사용한 단상 인버터 시스템)

  • Lee, Hyoung-Ju;Won, Hwa-Young;Lim, Seung-Beom;Hong, Soon-Chan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.5
    • /
    • pp.29-36
    • /
    • 2010
  • In this paper, we propose a single-phase inverter system using new modulation method. The proposed system is composed of a buck-boost converter and an inverter and controlled by PWAM scheme. PWAM method is a new modulation method which is the incorporation of PWM(Pulse Width Modulation) and PAM(Pulse Amplitude Modulation) methods. The DC voltage which is the input voltage of buck-boost converter is converted into a variable DC voltage by buck-boost converter. Also, the variable DC voltage which is the output voltage of buck-boost converter is converted into a sinusoidal AC voltage by inverter. The input voltage of inverter is processed by PWM switching in PWM section and bypassed in PAM section. By using PWAM method, switching action is not existed in PAM section and thus the times of switching is reduced. As a result, the switching loss can be reduced.

Characteristics of Unsteady Flows in a Semi-Induction System by a Variable Volume Helmholtz Resonator (가변 체적 헬름홀츠 공진기에 의한 유사 흡기 시스템의 비정상 유동특성)

  • Kang, K.E.;Kim, K.H.;Kang, H.Y.;Koh, D.K.
    • Journal of Power System Engineering
    • /
    • v.13 no.6
    • /
    • pp.57-62
    • /
    • 2009
  • Unsteady flows in a semi-induction system was investigated to verify their characteristics. A semi-induction system was designed and made to verify the Sow characteristics in an intake system. To attain an intact wave of an intake pulse, a single semi-intake system was adopted as a test rig. The system consists of an intake pipe and a rotary valve as a pulse generator, and a variable volume Helmholtz resonator. The variable volume Helmholtz resonator was mounted in the intake pipe to enhance a breathing capacity and engine performance. The phase and amplitude of the pulsating flow in an unsteady flow system were found to affect the charging capacity significantly. The behavior of pressure wave, their phase and amplitude were investigated in various regions. Some of the results obtained from experiments were described.

  • PDF

Luminance Control by the asymmetric sustain pulse amplitude in ACPDP (AC PDP에서 불평형 Sustain Pulse를 이용한 휘도제어법)

  • Choi, Joon-Young;Kim, Dong-Hyun;Lee, Ho-Jun;Park, Chung-Hoo
    • Proceedings of the KIEE Conference
    • /
    • 2003.10a
    • /
    • pp.33-35
    • /
    • 2003
  • The luminance of at PDP has been controlled by the number of sustain pulses. Therefore, it is very difficult to control the luminance by sustain pulses for a given gray level. This paper deals with a new method to control the luminance by the sustain pulse amplitude in ac PDP. The suggested method can control the luminance by 60% without change of the number of sustain pulses.

  • PDF

Write-in and Retention Characteristics of Nonvolatile MNOS Memory Devices (비휘발성 MNOS기억소자의 기억 및 유지특성)

  • 이형옥;강창수;이상배;서광열
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1991.10a
    • /
    • pp.44-47
    • /
    • 1991
  • Electron injection and memory retention chracteristics of the MNOS devices with thin oxide layer of 23${\AA}$ thick and silicon nitride layer of 1000${\AA}$ thick which are fabricated for this experiment. As a result, pulse amplitude increase oxide current is dominated in linearly increasing region of $\Delta$V$\_$FB/the decreasing region after saturation was due to the increased silicon nirtide current. In low pulse ampiltude $\Delta$V$\_$FB/ is not variated on temperature, but as temperature and pulse amplitude increase. $\Delta$V$\_$FB/ is decreased after saturation. And the decay rate during 10$^4$sec after electron injection was ohiefly dominated by the back tunneling of emission from memory trap to silicon. Memory retention characteristics in V$\_$FB/ stage was better than that of OV retention regardless of injection conditions.

A Novel M-ary Code-Selected Direct Sequence BPAM UWB Communication System

  • Bai, Zhiquan;Kwak, Kyung-Sup
    • ETRI Journal
    • /
    • v.28 no.1
    • /
    • pp.95-98
    • /
    • 2006
  • In this letter, a novel M-ary code-selected direct sequence (DS) ultra-wideband (UWB) communication system is presented. Our purpose is to achieve a high data rate by an M-ary code-selected direct sequence bipolar pulse amplitude modulation (MCSDS-BPAM) scheme. In this system, a particular DS code sequence is selected by the $log_2M$/2 bits from the DS gold code set. This scheme can accomplish both a high data rate without increasing the system bandwidth or changing the pulse shape and improve the BER with an increase of modulation level M even at a lower signal-to-noise ratio (SNR). The receiver signal processing algorithm is given for an MCSDS-BPAM UWB system over an ideal AWGN channel and correlation receivers.

  • PDF

The Characteristics of Terahertz Electromagnetic Pulses by Different Bias Voltage (전압 변화에 따른 테라헤르츠 전자기 펄스의 변화 특성)

  • 전태인;김근주
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.05a
    • /
    • pp.479-482
    • /
    • 2001
  • We have measured terahertz electromagnetic pulses when DC voltage from V up to 90V is applied to the transmitter chip excited by femto-second laser pulse. The femto-second excitation laser pulse was injected to transmitter chip. Finally, we are observed the amplitude of electromagnetic pulse and variation of spectrum. Consequently, the amplitude of spectrum was increased to high frequency according to increase of voltage. At that time, the signal-to-noise rate(SNR) is increased from 250:1 to 10, 000:1.

  • PDF

A Study on the Dielectric Degradation Using Partial Discharge System (부분방전 시스템을 이용한 절연 열화에 관한 연구)

  • 김성홍;이우상;정재용
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.35T no.1
    • /
    • pp.1-6
    • /
    • 1998
  • Our studies diagnose insulation degradation using the method of PD system. In analysis method of degradation, we make use of degradation information that analyzed the phase angle - PD pulse amplitude - degradation time( $\Phi$- PDA - t) pattern and phase angle- PD pulse number - degradation time( $\Phi$- PDN - t) pattern using statistical operators such as skewness(S), kurtosis(K). Secondly using statically operator such as the center of gravity (G), the gradient of the discharge distribution(C), we have analyzed for the prediction of life which we can be obtained the time, occurred of many pulse of small discharge amplitude.

  • PDF