• Title/Summary/Keyword: Pulse Rate Sensor

Search Result 98, Processing Time 0.025 seconds

Real-time Intelligent Health and Attention Monitoring System for Car Driver by Measurement of Vital Signal (생체신호 측정에 의한 실시간 지능형 운전자 건강 및 주의 모니터링 시스템)

  • Shin, Heung-Sub;Jung, Sang-Joong;Seo, Yong-Su;Chung, Wan-Young
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.545-548
    • /
    • 2009
  • Recently, researches related to automative mechanism have been widely studied to increase the driver's safety by continuously monitoring the driver's health condition to prevent driver's drowsiness. This paper describes the design of wearable chest belt for ECG and reflectance pulse oximetry for $SpO_2$ sensors based on wireless sensor network to monitor the driver's healthcare status. ECG, $SpO_2$ and heart rate signals can be transmitted via wireless sensor node to base station connected to the server. Intelligent monitoring system is designed at the server to analyze the $SpO_2$ and ECG signals. HRV(Heart Rate Variability) signals can be obtained by processing the ECG and PPG signals. HRV signals are further analyzed based on time and frequency domain to determine the driver's drowsiness status.

  • PDF

Modified Glassy Carbon Electrode with Polypyrrole Nanocomposite for the Simultaneous Determination of Ascorbic acid, Dopamine, Uric acid, and Folic Acid

  • Ghanbari, Khadijeh;Bonyadi, Sepideh
    • Journal of Electrochemical Science and Technology
    • /
    • v.11 no.1
    • /
    • pp.68-83
    • /
    • 2020
  • A fast and simple method for synthesis of CuxO-ZnO/PPy/RGO nanocomposite by electrochemical manner have been reported in this paper. For testing the utility of this nanocomposite we modified a GCE with the nanocomposite to yield a sensor for simultaneous determination of four analytes namely ascorbic acid (AA), dopamine (DA), uric acid (UA), and folic acid (FA). Cyclic voltammetry (CV) and Differential pulse voltammetry (DPV) selected for the study. The modified electrode cause to enhance electron transfer rate so overcome to overlapping their peaks and consequently having the ability to the simultaneous determination of AA, DA, UA, and FA. To synthesis confirmation of the nanocomposite, Field emission scanning electron microscopy (FE-SEM), Raman spectroscopy, and electrochemical impedance spectroscopy (EIS) were applied. The linearity ranges were 0.07-485 μM, 0.05-430 μM, 0.02-250 μM and 0.022-180 μM for AA, DA, UA, and FA respectively and the detection limits were 22 nM, 10 nM, 5 nM and 6 nM for AA, DA, UA, and FA respectively Also, the obtained electrode can be used for the determination of the AA, DA, UA, and FA in human blood, and human urine real samples.

A Study on the Ontology-Based Context Aware System for MBAN (MBAN(Medical Body Area Network)에서의 온톨로지 기반 상황인지 시스템 개발에 관한 연구)

  • Wang, Jong Soo;Lee, Dong Ho
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.7 no.1
    • /
    • pp.19-29
    • /
    • 2011
  • The u-Healthcare system, a new paradigm, provides healthcare and medical service anytime, anywhere in daily life using wired and wireless networks. It only doesn't reach u-Hospital at home, to manage efficient personal health in fitness space, it is essential to feedback process through measuring and analyzing a personal vital signs. MBAN(Medical Body Area Network) is a core of this technology. MBAN, a new paradigm of the u-Healthcare system, can provide healthcare and medical service anytime, anywhere on real time in daily life using u-sensor networks. In this paper, an ontology-based context-awareness in MBAN proposed system development methodology. Accordingly, ontology-based context awareness system on MBAN to Elderly/severe patients/aged/, with measured respiratory rate/temperature/pulse and vital signs having small variables through u-sensor network in real-time, discovered abnormal signs and emergency situations which may happen to people at sleep or activity, alarmed and connected with members of a family or medical emergency alarm(Emergency Call) and 119 system to avoid sudden accidents for early detection. Therefore, We have proposed that accuracy of biological signal sensing and the confidence of ontology should be inspected.

Low Cost and High Sensitivity Flexible Pressure Sensor Based on Graphite Paste through Lamination after O2 Plasma Surface Treatment Process (O2 플라즈마 표면 처리 공정 후 라미네이션 공정으로 제작된 흑연 페이스트 기반의 저비용 및 고감도 유연 압력 센서)

  • Nam, Hyun Jin;Kang, Cheol;Lee, Seung-Woo;Kim, Sun Woo;Park, Se-Hoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.29 no.4
    • /
    • pp.21-27
    • /
    • 2022
  • Flexible pressure sensor was developed using low-cost conductive graphite as printed electronics. Flexible pressure sensors are attracting attention as materials to be used in future industries such as medical, games, and AI. As a result of evaluating various electromechanical properties of the printed electrode for flexible pressure sensors, it showed a constant resistance change rate in a maximum tensile rate of 20%, 30° tension/bending, and a simple pulse test. A more appropriate matrix pattern was designed by simulating the electrodes for which this verification was completed. Utilizing the Serpentine pattern, we utilized a process that allows simultaneous fabrication and encapsulation of the matrix pattern. One side of the printed graphite electrode was O2 plasma surface treated to increase adhesive strength, rotated 90 times, and two electrodes were made into one through a lamination process. As a result of pasting the matrix pattern prepared in this way to the wrist pulse position of the human body and proceeding with the actual measurement, a constant rate of resistance change was shown regardless of gender.

The Mobile Health-Care Garment System for Measurement of Cardiorespiratory Signal (ECG와 호흡 측정이 가능한 모바일 헬스케어 의류 시스템)

  • Kim, Jeong-Do;Kim, Kap-Jin;Chung, Gi-Su;Lee, Jung-Hwan;Ahn, Jin-Ho;Lee, Sang-Goog
    • The KIPS Transactions:PartA
    • /
    • v.17A no.3
    • /
    • pp.145-152
    • /
    • 2010
  • Most wearable system for mobile healthcare applications consists of three parts. The first part is the sensing elements based on bio-signal, the second is the circuit module for control, data acquisition and wireless communication and control and the third is garment with a built-in electrodes and circuits. The existing healthcare garment systems have to find a solution to signal-wire and uncomfortable and inappropriate electrode to long-term attachment. Even if the wireless communication is used for healthcare garment system, the interface between sensors and circuits have to use wires. To solve these problems, this paper use electrode using PEDOT coated PVDF nanoweb for ECG signal and PVDF film sensor for respiratory signal. And, we constructed garment network using digital yarn of 10um, and transmitted ECG and respiratory signal to mobile phone through the integrated circuit with bluetooth called station To evaluate feasibility of the proposed mobile healthcare garment system, we experimented with transmission and measurement of ECG and respiratory signal using nanoweb electrode and digital yarn. We got a successful result without noise and attenuation.

Multimodal Biological Signal Analysis System Based on USN Sensing System (USN 센싱 시스템에 기초한 다중 생체신호 분석 시스템)

  • Noh, Jin-Soo;Song, Byoung-Go;Bae, Sang-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.5
    • /
    • pp.1008-1013
    • /
    • 2009
  • In this paper, we proposed the biological signal (body heat, pulse, breathe rate, and blood pressure) analysis system using wireless sensor. In order to analyze, we designed a back-propagation neural network system using expert group system. The proposed system is consist of hardware patt such as UStar-2400 ISP and Wireless sensor and software part such as Knowledge Base module, Inference Engine module and User Interface module which is inserted in Host PC. To improve the accuracy of the system, we implement a FEC (Forward Error Correction) block. For conducting simulation, we chose 100 data sets from Knowledge Base module to train the neural network. As a result, we obtained about 95% accuracy using 128 data sets from Knowledge Base module and acquired about 85% accuracy which experiments 13 students using wireless sensor.

Sleep Apnea Detection Using a Piezo Snoring Sensor: A Pilot study (코골이용 압전센서를 이용한 수면무호흡 검출에 관한 예비 연구)

  • Urtnasan, Erdenebayar;Lee, Hyo-Ki;Kim, Hojoong;Lee, Kyoung-Joung
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.4
    • /
    • pp.75-80
    • /
    • 2014
  • This paper proposed a method that can automatically classify sleep apnea by using features extracted from pulse rate variability(PRV) signals induced from piezo snoring sensor for patients with obstructive sleep apnea(OSA). We have extracted eight features(NN, SDNN, RMSSD, NN10, NN50, LF, HF and LF/HF ratio) based on time and frequency analyses of PRV. Sleep apnea was classified by a linear discriminant analysis(LDA). A performance was evaluated using snore recordings from 13 patients with OSA (ages: $54.5{\pm}10.5$ years, body mass index: $26.3{\pm}2.5kg/m^2$, apnea-hypopnea index: $19.2{\pm}6.0/h$). The sensitivity and specificity were $78.9{\pm}0.9%$ and $78.9{\pm}0.9%$ for training set and $77.7{\pm}10.9%$ and $79.0{\pm}2.8%$ for test set, respectively. Our study demonstrated the feasibility of implementing a piezo snoring sensor based on a portable device as a simple and cost-effective solution for contributing to the OSA screening.

Fundamental Study of Degradation Diagnosis using AE Signals with Void Discharge in XLPE Insulation (XLPE 절연체의 트리 채널내 보이드방전에 의한 AE신호로 절연열화 검출 기법 연구)

  • Lee, Sang-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.2
    • /
    • pp.75-80
    • /
    • 2006
  • In this paper, to detect and observation the void discharges pulse signal, AE signals and tree growth characteristics in case the high voltage is applied to a XLPE sample for a power cable. We also examined the partial discharge current pulse and AE signals with the increase of the applied voltage in XLPE insulation. The experimental results show that a branch-type tree grows in the presence of the voids, and a bush-type tree grows in the absence of the voids in both samples. A rate of tree growth increases abruptly in proportional to the deterioration time in the presence of the of the voids, but in the absence of the voids, a rate of tree growth decreases as time goes by and finally a breakdown occurs. The frequency band of AE signals that are generated from the partial discharges in a XLPE sample, one of solid dielectric materials, is about 1.0[MHz].

Development of the Pneumatic Servo Valve

  • Kim, Dong-Soo;Choi, Byung-Oh;Kim, Kwang-Young;Lee, Won-Hee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1146-1151
    • /
    • 2003
  • Pneumatic servo valve is an electro-mechanical device which change electric signals to a proper pneumatic signals, that is, flowrate and pressure. In this study, a pneumatic servo valve was designed and each simulation was conducted on any variation in the flowrate depending upon the magnetic force of the linear force motor and the displacement of the spool. And permanent magnet was used as a material for the plunger of the servo valve. Thereby, a low electrical power consumption type coil was desinged. And a modeling for the coil design was conducted by using the magnetic circuit. also, the feasibility of the modeling was verified by using a commercial magnetic field analysis program. The designed and fabrication of the spool and sleeve, position sensor, servo controller and the dynamic characteristic verified by the experiment.

  • PDF

Determination of Ascorbic Acid, Acetaminophen, and Caffeine in Urine, Blood Serum by Electrochemical Sensor Based on ZnO-Zn2SnO4-SnO2 Nanocomposite and Graphene

  • Nikpanje, Elham;Bahmaei, Manochehr;Sharif, Amirabdolah Mehrdad
    • Journal of Electrochemical Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.173-187
    • /
    • 2021
  • In the present research, a simple electrochemical sensor based on a carbon paste electrode (CPE) modified with ZnO-Zn2SnO4-SnO2 and graphene (ZnO-Zn2SnO4-SnO2/Gr/CPE) was developed for the direct, simultaneous and individual electrochemical measurement of Acetaminophen (AC), Caffeine (Caf) and Ascorbic acid (AA). The synthesized nano-materials were investigated using scanning electron microscopy, X-ray Diffraction, Fourier-transform infrared spectroscopy, and electrochemical impedance spectroscopy techniques. Cyclic voltammetry and differential pulse voltammetry were applied for electrochemical investigation ZnO-Zn2SnO4-SnO2/Gr/CPE, and the impact of scan rate and the concentration of H+ on the electrode's responses were investigated. The voltammograms showed a linear relationship between the response of the electrode for individual oxidation of AA, AC and, Caf in the range of 0.021-120, 0.018-85.3, and 0.02-97.51 μM with the detection limit of 8.94, 6.66 and 7.09 nM (S/N = 3), respectively. Also, the amperometric technique was applied for the measuring of the target molecules in the range of 0.013-16, 0.008-12 and, 0.01-14 μM for AA, AC and, Caf with the detection limit of 6.28, 3.64 and 3.85 nM, respectively. Besides, the ZnO-Zn2SnO4-SnO2/Gr/CPE shows an excellent selectivity, stability, repeatability, and reproducibility for the determination of AA, AC and, Caf. Finally, the proposed sensor was successfully used to show the amount of AA, AC and, Caf in urine, blood serum samples with recoveries ranging between 95.8% and 104.06%.