• Title/Summary/Keyword: Pulse Oximeter

Search Result 81, Processing Time 0.029 seconds

Case Study of 4-Bar Linkage KAFO in Person With Poliomyelitis (소아마비에서 4절 연쇄 장하지보조기 사례연구)

  • Kim, Jang-Hwan;Kwon, Oh-Yun;Yi, Chung-Hwi;Cho, Sang-Hyun;Cynn, Heon-Seock;Choi, Heung-Sik
    • Physical Therapy Korea
    • /
    • v.20 no.1
    • /
    • pp.18-27
    • /
    • 2013
  • The purpose of this study was to compare the ring lock type knee-ankle-foot orthosis (KAFO) with newly developed 4-bar linkage KAFO on the gait characteristics of persons with poliomyelitis clinically. This 4-bar linkage is the stance control type KAFO which provide the stability during stance phase and knee flexion during swing phase. Two subjects participated in this study voluntarily. We provided the customized 4-bar linkage KAFO then asked the subjects to walk in level surface and stairs under the two different KAFO conditions. The characteristics of gait in the persons with poliomyelitis were evaluated using a 3D motion analysis system and force plate. Additionally 6 minute walk test for physiological cost index were conducted using pulse oximeter to measure the energy consumption. In the results of this study, the differences of 4-bar linkage KAFO compared with ring lock type KAFO are as follows: (1) Walking speed, stride length, and step length on level increased in subjects, (2) The gait symmetry was improved by generated knee flexion and decreased pelvic external rotation on level and stairs walking, (3) Decreased vertical excursion of center of mass and pelvic elevation during swing phase was decreased on level, (4) Knee extension moment, hip flexion moment, hip and knee internal rotation moment of non-braced limb were decreased on level walking, (5) Walking speed in 6-minute walk test was increased and physiological cost index was decreased. These findings indicate that 4-bar linkage KAFO compared with ring lock type KAFO is effective in enhancing pattern, endurance, and energy consumption in level surface and stairs walking.

Level of Obstructive Sleep Apnea of Patients with Ischemic Cardio-cerebrovascular Disease and Affecting Factors (허혈성 심뇌혈관질환자에서 폐쇄성 수면무호흡증 정도 및 영향요인)

  • Kim, Sun Hwa;Hwang, Seon Young
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.4
    • /
    • pp.114-127
    • /
    • 2018
  • This study aimed to investigate the levels of Obstructive Sleep Apnea (OSA), health behavior and sleep quality and to examine the predictors of OSA in patients with ischemic cardio-cerebrovascular disease. 141 patients who were admitted to the vascular unit were recruited and surveyed using structured questionnaires. Saturation of Peripheral Oxygen (SpO2) was measured at three time points using a pulse oximeter. Data were analyzed using SPSS/WIN 20.0. The mean age of the subjects was $64.4{\pm}11.1$ years and 61% was men. The 21.3%(n=30) of the subjects were classified as high-risk for OSA by the cut point and 71.6%(n=101) had low sleep quality. OSA high-risk group showed significant difference in SpO2 in the middle of sleep (p=.006) and at the end of sleep (p=.004) compared to the low-risk group. Multiple logistic regression analysis showed that perceived frequent snoring, smoking, obesity, lack of exercise among health behavior were found as predicting factors on OSA. OSA or persistent snoring should be recognized as a cardiovascular risk factor in the cardiovascular nursing practice. In addition to early treatment of OSA, education and counseling should be provided to patients and their family for prevention of secondary recurrence.

The Effect of Dynamic Balance on Cyber Motion Sickness of Full Immersion Virtual Reality (완전 몰입형 가상현실로 인한 사이버 멀미가 동적 균형에 미치는 영향)

  • Kim, Na-Eun;Kim, Yu-lim;Moon, Sang-cheol;Lee, Dong-hung;Lim, Ho-jeong;Jang, Eun-kyung;Hung, Ji-eun;Kang, Jong-ho
    • Journal of Convergence for Information Technology
    • /
    • v.8 no.1
    • /
    • pp.131-138
    • /
    • 2018
  • The purpose of the study was to explore whether the Cyber Motion sickness used VR causes a change in the dynamic balance and fall. For 39 people who voluntarily participated in this study, this study measured the motion sickness questionnaires, the heart rate and stability of limit test in BioRescue. The study used Samsung Gear VR and applied the games to the To the homeland. The game proceeded 20minutes. Although the value of the stability after a VR application is slightly reduced, it did not reach statistical significance. The motion sickness questionnaires increased, and it had a statistical significant impact. Also Heart rate increased and it had a statistically significant impact. A virtual reality game affect for getting motion sickness but it did not affect the dynamic balance. So, cyber motion sickness caused by virtual reality wear does not result in decreased balance and falls.

Effectiveness and Safety of High-Flow Nasal Cannula Oxygen Delivery during Bronchoalveolar Lavage in Acute Respiratory Failure Patients

  • Kim, Eun Jin;Jung, Chi Young;Kim, Kyung Chan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.81 no.4
    • /
    • pp.319-329
    • /
    • 2018
  • Background: Bronchoalveolar lavage (BAL) is a necessary procedure for diagnosis of various lung diseases. High-flow nasal cannula (HFNC) oxygen delivery was recently introduced. This study aimed to investigate the safety and effectiveness of HFNC oxygen supply during BAL procedure in patients with acute respiratory failure (ARF). Methods: Patients who underwent BAL while using HFNC at a partial pressure of oxygen in arterial blood/fraction of inspired oxygen ($PaO_2/FiO_2$; PF) ratio of 300 or below among patients who had been admitted from March 2013 to May 2017 were retrospectively investigated. Results: Thirty-three BAL procedures were confirmed. Their baseline PF ratio was $166.1{\pm}46.7$. $FiO_2$ values before, during, and after BAL were $0.45{\pm}0.12$, $0.74{\pm}0.19$, and $0.57{\pm}0.14$, respectively. Flow (L/min) values before, during, and after BAL were $26.5{\pm}20.3$, $49.0{\pm}7.2$, and $40.8{\pm}14.2$, respectively. Both $FiO_2$ and flow during and after the procedure were significantly different from those before the procedure (both p<0.001). Oxygen saturation levels before, during, and after BAL measured by pulse oximeter were $94.8{\pm}2.9$, $94.6{\pm}3.5$, and $95.2{\pm}2.8%$, respectively. There were no significant differences in oxygen saturation among the three groups. Complications of BAL procedure included transient hypoxemia, hypotension, and fever. However, there was no endotracheal intubation within 24 hours. Baseline PF ratio in "without HFNC" group was significantly higher than that in "with HFNC" group. There were no differences in complications between the two groups. Conclusion: The use of HFNC during BAL procedure in ARF patients was effective and safe. However, there were no significant differences in oxygen saturation level and complications comparing "without HFNC" group in mild ARF. More studies are needed for moderate to severe ARF patients.

SEDATION PRACTICES IN DENTAL OFFICE : A SURVEY OF MEMBERS OF THE KOREAN ACADEMY OF PEDIATRIC DENTISTRY (진정요법사용에 관한 설문조사)

  • Choi, Young-Sim;Shim, Youn-Soo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.26 no.4
    • /
    • pp.579-588
    • /
    • 1999
  • Monitoring of patients is essential in assuring the safety of sedation in the dental office. The purpose of this study was to explore the utilization and preferences of sedation, utilization of monitoring methods, and the preparation for emergencies during sedation. Members of the Korean Academy of Pediatric Dentistry were surveyed(n=245) from 1998. 10. 1 to 1998. 12. 20 to establish current trends in the use of sedation practices and monitoring methods in Korea. Findings of the survey include: 1. Twenty nine percent of pediatric dentists use sedative agents in their practices. Seventy one percent of pediatric dentists do not use any sedative agents in their practices 2. Thirty nine percent of pediatric dentists who use sedative agents do so without monitoring devices 3. Nitrous oxide inhalation sedation was the most frequently utilized sedation method by pediatric dentists and chloral hydrate was the most frequently utilized sedative by pediatric dentists. Pulse oximeter was the most frequently utilized monitoring method during sedation in dental office. 4. Only twenty eight percent of pediatric dentists obtain the informed consent of the child's legal guardian. 5. Only sixty percent of pediatric dentists prepare for emergencies during sedation.

  • PDF

A Study on the Effect which the Method of Deep Breathing with the Use of Incentive Spirometer has on the function of pulmonary Ventilation - In Upper Abdominal Operation Patients - (Incentive Spirometer를 사용한 심호흡 방법이 폐환기 기능에 미치는 효과에 관한 연구 -상복부 수술 환자를 대상으로-)

  • 김종혜;변영순
    • Journal of Korean Academy of Nursing
    • /
    • v.21 no.3
    • /
    • pp.268-280
    • /
    • 1991
  • The nursing intervention for the prevention of the pulmonary complication and of the function lowering of pulmonary ventilation which emerge with high generation frequency during the nursing of operation patient is necessary for performing the qualitative nursing for operation patient. So, this researcher tried this study so as to obtain the data which can be utilized for the trial of nursing intervention, by grasping the effect that the deep breathing with Incentive Spirometer has on the function of pulmonary ventilation, analysing the factor to have influence on the function of pulmonary ventilation, and applying the effective method of deep breathing to the clinic. By making 42 patients who underwent the operation of upper abdomen after admitting G Hospital in Seoul from Mar. 7, 1991 to Apr.30, 1991 as the object, they were classified into the experiment group that the deep breathing was made with the use of Incentive Spiromenter and the comparison group that the deep breathing exercise was made without the use of Incentive Spirometer. And then, by measuring Tidal Volume and Forced Vital Capacity with Respirometer and $O_2$ Saturation with Pulse Oximeter at preoperation postoperation 24 hours, 72 hours, and 120 hours data were collected. The collected data were analyzed with of, average, standard deviation, x$^2$-test, t-test and ANOVA by SPSS. The result of this study is as follows : 1. As for the hypothesis that the function of pulmonary ventilation at postoperation 24 hours, 72 hours and 120 hours will be better in the experiment group that the deep breathing was made with the use of Incentive Spirometer, in comparison with the comparison group that deep breathing was made without the use of Incentive Spirometer, experiment group and comparison group didn't show the significant difference in Tidal Volume, Foreced Vital Capacity and $O_2$ Saturation at postoperation 24 hours and 72 hours. But experiment group and comparison group showed the significant difference in Tidal Volume at postoperation 120 hours (p<0.01). So, this hypothesis was supported partially. 2. The variables that there were the significant differences about the function of pulmonary ventilation in experiment group at postoperation 24 hours stastically were smoking existence (p<0.05), and the variables that there were not significant differences about the function of pulmonary ventilation were distinction of sex, age, anesthetic duration, smoking extent, body weight, surface area of body, existence of narcotic use, regular exercise existence, and past experience existence of respiratory disease. As above result, it appeared that the method of deep breathing with the use of the Incentive Spirometer is more effective for the function recovery of pulmonary ventilation, in comparison with the deep breathing without use of Incentive Spirometer and that smoking existence was the factor to have influence on the function of pulmonary ventilation. In the aspect of clinic, the trial of nursing intervention of deep breathing with use of Incentive Spirometer is expected. And, in the aspect of study, the study through various operative site patients about the effect of Incentive Spirometer use at the clinic will have to be confirmed.

  • PDF

SEDATION EVALUATION USING BIS INDEX ASSESSMENT WITH AND WITHOUT THE ADDED SUBMUCOSAL MIDAZOLAM (점막하 Midazolam의 병용투여 시 BIS 분석을 이용한 진정 평가)

  • Lee, Young-Eun;Park, Mi-Kyung;Kim, So-Young;Kim, Yun-Hee;Jung, Sang-Hyuk;Baek, Kwang-Woo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.34 no.1
    • /
    • pp.91-98
    • /
    • 2007
  • The aim of this study was to examine the difference of the depth of sedation using the Bispectral index assessment with and without the added submucosal Midazolam to oral Chloral hydrate and Hydroxyzine for pediatric patients. Twenty seven sedation cases were performed in this study Selection criteria included good health(ASA I), 2 to 6 years of age, the need for sedation to receive dental treatment including anesthesia, and restorative procedure over at least two teeth. Patients were randomly classified into one group taking oral Chloral hydrate(60 mg/kg) and Hydroxyzine(1 mg/kg) and the other group recieving Chloral hydrate(60 mg/kg), Hydroxyzine(1 mg/kg) and submucosal Midazolam(0.1 mg/kg). Nitrous Oxide(50%) was used for both group during sedation. Patients were monitored using a pulse oximeter and a Bispectral monitor. A behavior scale was rated as quiet(Q), crying(C), movement(M), or struggling(S) every 2 minutes watching a recorded videotape. Analysis showed a significant difference in mean Bispectral index and SD during sedation across two groups(P<0.001). The group of patients injected with submucosal Midazolam in addition to oral Chloral hydrate and Hydroxyzine showed a lower mean Bispectral index and a narrower SD. PR and SpO2 for both groups remained within the normal values. Submucosal Midazolam improved the sedation quality by deepening sedation depth without compromising safety and enabled the sedation pattern to be kept more stable.

  • PDF

Nocturnal Arterial Oxygen Saturation Monitoring in Patients with Respiratory Disease (호흡기 질환 환자들에서 야간 동맥혈 산소포화도 감시 성적)

  • Choi, In-Seon;Yang, Jae-Beom;Kim, Young-Chul;Chung, Ik-Joo;Kang, Yu-Ho;Koh, Yeoung-Il;Park, Sang-Seon;Lee, Min-Su;Park, Kyung-Ok
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.2
    • /
    • pp.103-110
    • /
    • 1994
  • To find out the predictors of nocturnal arterial oxygen desaturation in patients with respiratory diseases, transcutaneous oxygen saturation($StcO_2$) monitoring studies using a pulse oximeter were performed during sleep in 20 patients. $StcO_2$ was decreased more than 4% from the baseline value in 18 patients(90%) and more than 10%("Desaturator") in 8(40%). Five of the seven patients(71.4%) with awake $PaO_2$<60mmHg and three of the thirteen patients(23.1%) with awake $PaO_2{\geq}60mmHg$ were "desaturators". The awake $PaO_2/FIO_2$ and $PaO_2/PAO_2$ could distinguish "desaturator" from "nondesaturator", and $PaO_2,\;SaO_2$ or $StcO_2$ could not. These results suggest that the nocturnal oxygen desaturation depends on the severity of the underlying disease rather than the baseline $PaO_2$. Anthropomorphic and lung function factors could not separate between "desaturator" and "non-desaturator", and about a quater of patients with a wake $PaO_2{\geq}60mmHg$ developed significant desaturation. Therefore, it is necessary to monitor the nocturnal arterial oxygen saturation in patients with respiratory diseases regardless of their severity of airflow obstruction or awake $PaO_2$.

  • PDF

Long-term oxygen therapy in patients with chronic respiratory failure in one university hospital (호흡부전환자의 재택산소치료 실태: 한 대학병원에서의 관찰)

  • Huh, Jin Won;Lee, Jung Yeon;Hong, Sang-Bum;Oh, Yeon Mok;Shim, Tae Sun;Lim, Chae-Man;Lee, Sang Do;Kim, Woo Sung;Kim, Dong Soon;Kim, Won Dong;Koh, Younsuck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.58 no.2
    • /
    • pp.160-166
    • /
    • 2005
  • Background : Although home oxygen therapy in hypoxemic patients with chronic lung disease has been increasing over the decade in Korea, the present state has not been known well. This study was done to know the situation of home oxygen therapy in a Korean university hospital. Methods : Between January 1, 2000 and August 31, 2003, 86 patients prescribed home oxygen therapy by the pulmonary physicians of Asan Medical Center were investigated using their medical record and questionnaire. Results : Patients (52 men, mean age of 61 years) with home oxygen therapy were increasing by every year. Underlying diseases were COPD (n=29), tuberculous destroyed lung (n=18), bronchiectasis (n=15), ILD (n=12), and others. Baseline $FEV_1/FVC$, FVC, and $FEV_1$ of patients were $58.4{\pm}25.2%$, $54.5{\pm}17.1%$ of predicted, and $41.7{\pm}20.6%$ of pred. Mean oxygen flow was 1.5 L/min and mean duration per day was 14.5 hours. During therapy, mean $PaO_2$ values have increased from 51.2 to 77.7 mm Hg and $PaCO_2$ values have increased from 47.5 to 49.6 mm Hg. Only 16.5% of the subjects were monitored by visiting nurses or pulse oximeter. Three year survival rate was 56.6% and hypercapnic patients showed better prognosis. Conclusion : The patients with home oxygen therapy were increasing yearly and a part of them were monitored. The hypercapnea respiratory failure patients would have better prognosis.

Comparison of Behavioral Response between Intranasal and Submucosal Midazolam Adminstration (소아 진정 치료 시 구강 점막 하와 비점막 Midazolam 투여의 행동 반응 비교)

  • Kim, Yun-Hee;Jung, Sang-Hyuk;Baek, Kwang-Woo
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.35 no.3
    • /
    • pp.427-436
    • /
    • 2008
  • Purpose. The objective of this study was to evaluate the behavioral response and assess the effectiveness of additional intranasal (IN) and submucosal (SM) administration of midazolam during pediatric sedation for dental procedure. Material and methods. Thirty-three cases of healthy (ASAⅠ), uncooperative children aged from 24 to 72 month old at pediatric dental clinic of Ewha Womans University Hospital were selected for this study. Children received oral chloral hydrate 50 mg/kg with hydroxyzine 1.0 mg/kg. After waiting for 45 minutes, midazolam 0.2 mg/kg was administrated via IN route and via SM route randomly maintaining 50% of $N_2O$. A pulse oximeter and a capnograph were used for measuring vital signs ($SpO_2$, PR, RR, $EtCO_2$) throughout the sedation. Behavioral response was evaluated as Quiet (Q), Crying (C), Movement (M) or Struggling (S) in every 2 minutes for 40 minutes. Results. There were also no statistically significant differences in vital signs of the two groups. The behavioral response for the first ten minutes during sedation was a statistically significant difference (P < 0.05) between the two groups. After the first ten minutes, it was revealed that there was no significant difference. Conclusion. This study demonstrated that the addition of IN midazolam to the combination of oral chloral hydrate with hydroxyzine and nitrous oxide/oxygen inhalation is as safe and effective as that of SM midazolam in pediatric sedation for dental procedure.

  • PDF