• Title/Summary/Keyword: Pulse Measurement

Search Result 950, Processing Time 0.023 seconds

Development of Ultrasonic Testing Method for Evaluation of Adhesive Layer of Blaster Tube (토출관 접합계면 평가를 위한 초음파 시험법 개발)

  • Kim, Y.H.;Song, S.J.;Park, J.S.;Cho, H.;Lim, S.Y.;Yun, N.G.;Park, Y.J.
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.8 no.2
    • /
    • pp.46-53
    • /
    • 2004
  • Ultrasonic testing method has been developed to evaluate flaw of adhesive layers in blast tube for the reliability of the rocket nozzle. The ultrasonic reflection from the interface between the steel sheet and the epoxy adhesive is measured with a high-frequency Pulse-echo setup in order to identify contact debonding and missing adhesive in epoxy layer between steel and FRP layers. The steel sheet is resonated by low-frequency ultrasound, and the gap size underneath the measuring location is estimated from the resonance responses. For practical application in industry an automated testing system has been developed where the proposed approach is implemented. The performance of the proposed approach has been verified by actual measurement of gap sizes from the cross-sections of cut specimens using an optical microscope.

Measurements of Correct Operation of a HTS 4-bit Shift Register Circuit (4-비트 고온초전도 Shift Register 회로의 동작 측정)

  • Park, Jong-Hyeog;Kim, Young-Hwan;Kang, Joon-Hee;Hahn, Taek-Sang;Kim, Chang-Hoon;Lee, Jong-Min;Choi, Sang-Sam
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.102-106
    • /
    • 1999
  • We have designed and fabricated a four-bit shift register circuit using YBCO bicrystal junctions and experimentally tested its operations by a computer-controlled digital measurement set-up. Laser ablated YBCO thin films with clean surface were used in this work. The circuit consists of the shift register and two read SQUIDs placed next to each sides of the shift register. The SQUIDs were inductively coupled to the nearby shift register stages. A probe equipped with high speed coax lines were used in this experiment. The major obstacle in testing the circuit was the interference between the read SQUIDs and we solved the problem by finding the correct operation points of the SQUIDs from the simultaneously measured modulation curves. Loaded Data("1" or "0") were successfully shifted from a stage to the next one by a controlled current pulse injected to the bias lines located between the stages and the data shifts were correctly monitored by the read SQUIDs

  • PDF

Development of ultrasonic testing method for the evaluation of adhesive layer of blast tube (토출관 접합계면 평가를 위한 초음파 시험법 개발)

  • Kim, Y.H.;Song, S.J.;Park, J.S.;Cho, H.;Lim, S.Y.;Yun, N.G.;Park, Y.J.
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.230-237
    • /
    • 2003
  • Ultrasonic testing method has been developed to evaluate adhesive layers in blast tube for the reliability of the rocket. The main objective of the present work was to find debonding and missing adhesive in epoxy layer between steel and FRP layers. In this approach, the ultrasonic reflection from the interface between the steel sheet and the epoxy adhesive is measured with a high-frequency pulse-echo setup in order to identify contact debonding and missing adhesive. Then, the steel sheet is excited to resonance by low-frequency ultrasound, and the gap size underneath the measuring location is estimated from the resonance responses. For practical application in industry an automated testing system has been developed where the proposed approach is implemented. The performance of the proposed approach has been verified by actual measurement of gap sizes from the cross-sections of cut specimens using an optical microscope.

  • PDF

A Study on Home Nursing Care Requirement and Activities of Daily Life Among the Elderly at Home (재가노인의 가정간호요구도 및 일상생활능력에 관한 연구)

  • 조선화;김병성;김공현;박형종
    • Korean Journal of Health Education and Promotion
    • /
    • v.11 no.2
    • /
    • pp.125-145
    • /
    • 1994
  • The objectives of this study were to characterize the health status, the requirement of home nursing care, and dependency of daily life of the elderly so that the result could be used to provide basic data necessary for establishing home nursing care practices. The study subjects were 249 elders over 65 years old who resided at home in low income areas of three districts in Pusan. The field survey was conducted from December 27, 1993 through January 27, 1994, with a structured questionnaire. Statistical analysis was done by X²-test and Student's T-test using SPSS/PC/sup +/ program. The result were as follows; 1. Alcohol drinking rate was 50.0% for men and 27.7% for women, and cigarette smoking rate was 77.8% for men and 27.1% for women. 92.9% of elders aged 65-75 exercised regularly as compared to 81.9% of elders aged 75 and over(p<0.05). 2. 63.9% of male and 85.9% of female elders had chronic diseases showing singnificant differences(p<0.01), and both sexes had 1.7 kinds of chronic diseases in average; musculoskeletal diseases were the most common in 25.7%, while 6.8% of the elderly had cardiovascular diseases. 3. Partially movable elderly was 6.9% for men and 6.8% for woman, showing 47.1% of causes being cerebrovascular accidents. 4. The home nursing requirement was the highest for medication(66.3%), intramuscular injection(53.8%), and measurement of blood pressure·body·temperature·pulse rate(47.0%). 5. Among Physical Activities of Daily Life, bathing(10.4%) and movement(4.0%) showed high dependency rates, and among Instrumental Activities of Daily Life, phone calling(25.3%), shopping(24.5%), going out by bus(22.5%) showed high dependency rates. 6. For five categories of home nursing showing high requirements such as physical health examination, blood pressure·temperature·pulas rate measurements, medication, and intravascular injection, the requirements were different by age groups, education, and marital status(p<0.05).

  • PDF

SAR Motion Compensation Using GPS/IMU (GPS/IMU를 이용한 SAR 영상의 요동 보상 기법에 대한 연구)

  • Kim, Dong-Hyun;Park, Sang-Hong;Kim, Kyung-Tae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.1
    • /
    • pp.16-23
    • /
    • 2011
  • This paper suggests a motion compensation technique using GPS/IMU data in order to compensate for phase error caused by undesired motion of radar platform. An actual flight trajectory would be deviate from an ideal straight-constant trajectory with a constant velocity for SAR imaging, due to pitch, roll and yaw motion of aircraft caused by turbulence. This leads to blurred SAR images due to inter-pulse phase errors as well as along-track velocity errors. If the motion compensation is carried out to reduce those errors, SAR image quality can be significantly improved. Simulation results show that the motion compensation technique introduced in this paper is an effective tool to improve SAR image quality against severe motion of radar platform.

Change of RIII Reflex of Primary and Secondary Hyperalgesia Site by High Voltage Pulsed Current (고전압맥동전류에 의한 일차 및 이차통각과민대의 RIII 반사의 변화)

  • Kim, Su-Hyon;Choi, Sug-Ju;Lee, Jung-Woo;Jeong, Jin-Gyu;Kim, Tae-Youl;Kim, Gye-Yeop
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.4 no.1
    • /
    • pp.1-12
    • /
    • 2006
  • This study conducted RIII reflex measurement to examine degree of pain depending on polarity of high voltage pulsed current of primary and secondary hyperalgesia site in hyperalgesia rat by local thermal injury. Hind paw which was injury site was taken as primary hyperalgeisa site, sole which was injury adjacent site was taken as secondary hyperalgesia site, and mechanical pain threshold, thermal pain threshold and root mean square of RIII reflex were measured. This study was conducted with control group I of hyperalgesia rat at hind paw by thermal injury and experimental groups divided into cathodal high voltage treatment group II, anodal high voltage treatment group III and alternate high voltage treatment group IV, applied active electrode of high voltage pulsed current to hind paw directly, placed reference electrode on the sole of injury adjacent site and applied pulse frequency. It measured RIII reflex and obtained the following results: Root mean square of RIII reflex at primary hyperalgeisa site was significantly reduced in group II after 2 days of hyperalgesia. Group II showed significant decrease after 5 and 6 days of hyperalgesia. Root mean square of RIII reflex at secondary hyperalgesia site showed significant reduction in group II after 6 days of hyperalgesia. Consequently it was found that application of high voltage pulsed current of hyperalgesia site reduced RIII reflex at primary hyperalgeisa site and secondary hyperalgesia site by electrical stimuli. Effects by polarity of high voltage pulsed current showed the greatest reduction of pain threshold when cathodal active electrode was used.

  • PDF

Wall Charge Measurement in the Address Period of AC Plasma Display Panel

  • Kim, Dong-Hyun;Lee, Sung-Hyun;Kim, Young-Dae;Park, Jung-Tae;Lee, Gi-Bum;Lee, Jae-Young;Ryu, Jae-Hwa;Park, Chung-Hoo
    • Journal of Information Display
    • /
    • v.1 no.1
    • /
    • pp.42-47
    • /
    • 2000
  • The relationship between driving voltage and the amount of wall charge in the address period of surface discharge type AC Plasma Display Panel has been investigated. The amount of wall charge on each electrode is obtained simultaneously from the current profiles after applying only one addressing discharge pulse. The wall charge $Q_y$ on the scan electrode Y is almost the sum of $Q_x$ on the address electrode X and $Q_z$ on the sustain electrode Z. The $Q_y$ increased with the driving voltage regardless of the kind of electrode, whereas the addressing $T_d$ decreased. The $Q_x$ and $Q_y$ are increased considerably by blocking voltage $V_z$, whereas $Q_x$ is decreased. The $V_z$ dependence of $Q_x$ $Q_y$ and ${\varrho}_z$ in addressing discharge was $-13{\times}10^{-2}$ (pc/$V_z$), and $60{\times}10^{-2}$ ($pc/V_z$) and $70{\times}10^{-2}(pc/V_z)$, respectively.

  • PDF

Experiment of an ABS-type control strategy for semi-active friction isolation systems

  • Lu, Lyan-Ywan;Lin, Ging-Long;Lin, Chen-Yu
    • Smart Structures and Systems
    • /
    • v.8 no.5
    • /
    • pp.501-524
    • /
    • 2011
  • Recent studies have discovered that a conventional passive isolation system may suffer from an excessive isolator displacement when subjected to a near-fault earthquake that usually has a long-period velocity pulse waveform. Semi-active isolation using variable friction dampers (VFD), which requires a suitable control law, may provide a solution to this problem. To control the VFD in a semi-active isolation system more efficiently, this paper investigates experimentally the possible use of a control law whose control logic is similar to that of the anti-lock braking systems (ABS) widely used in the automobile industry. This ABS-type controller has the advantages of being simple and easily implemented, because it only requires the measurement of the isolation-layer velocity and does not require system modeling for gain design. Most importantly, it does not interfere with the isolation period, which usually decides the isolation efficiency. In order to verify its feasibility and effectiveness, the ABS-type controller was implemented on a variable-friction isolation system whose slip force is regulated by an embedded piezoelectric actuator, and a seismic simulation test was conducted for this isolation system. The experimental results demonstrate that, as compared to a passive isolation system with various levels of added damping, the semi-active isolation system using the ABS-type controller has the better overall performance when both the far-field and the near-fault earthquakes with different PGA levels are considered.

Chaotic particle swarm optimization in optimal active control of shear buildings

  • Gharebaghi, Saeed Asil;Zangooeia, Ehsan
    • Structural Engineering and Mechanics
    • /
    • v.61 no.3
    • /
    • pp.347-357
    • /
    • 2017
  • The applications of active control is being more popular nowadays. Several control algorithms have been developed to determine optimum control force. In this paper, a Chaotic Particle Swarm Optimization (CPSO) technique, based on Logistic map, is used to compute the optimum control force of active tendon system. A chaotic exploration is used to search the solution space for optimum control force. The response control of Multi-Degree of Freedom (MDOF) shear buildings, equipped with active tendons, is introduced as an optimization problem, based on Instantaneous Optimal Active Control algorithm. Three MDOFs are simulated in this paper. Two examples out of three, which have been previously controlled using Lattice type Probabilistic Neural Network (LPNN) and Block Pulse Functions (BPFs), are taken from prior works in order to compare the efficiency of the current method. In the present study, a maximum allowable value of control force is added to the original problem. Later, a twenty-story shear building, as the third and more realistic example, is considered and controlled. Besides, the required Central Processing Unit (CPU) time of CPSO control algorithm is investigated. Although the CPU time of LPNN and BPFs methods of prior works is not available, the results show that a full state measurement is necessary, especially when there are more than three control devices. The results show that CPSO algorithm has a good performance, especially in the presence of the cut-off limit of tendon force; therefore, can widely be used in the field of optimum active control of actual buildings.

Analysis of the Characteristics of the Feed motor Current for the Estimation of the Cutting Force in General Cutting Environment (일반적 상황에서 2차원 절삭력 추정을 위한 이송모터 전류의 거동분석)

  • Jeong, Young-Hun;Yun, Seong-Hyun;Cho, Dong-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.4
    • /
    • pp.93-100
    • /
    • 2002
  • The current from the feed motor of a machine tool contains substantial information about the machining state. There have been many researches that investigated the current as a measure for the cutting farces. However it has been reported that this indirect measurement of the cutting farces from the feed motor current is only feasible in low frequency. In this research, it was presented that the bandwidth of the current monitoring can be expanded to 130 Hz. And the unusual behavior of the current was examined in this bandwidth. The cross-feed directional cutting force influences the machined surface of the workpiece, which makes it necessary to estimate this force to control the roughness of the machined sulfate. The current exists in the stationary feed motor, and it can give the useful information on the quality of the machined surface. But the unpredictable behavior of the current prevents applying the current to prediction of the cutting state. Empirical approach was conducted to resolve the problem. As a result, the current was shown to be related to the accumulation of the accumulation of the infinitesimal rotation of the motor. rotation of the motor. Subsequently the relationship between the current and the cutting force was identified.