• 제목/요약/키워드: Pulse Measurement

검색결과 947건 처리시간 0.029초

A New Measurement Method of a Radial Pulse Wave Using Multiple Hall Array Devices

  • Lee, Sang-Suk;An, Myoung-Chone;Ahn, Sung-Hoon
    • Journal of Magnetics
    • /
    • 제14권3호
    • /
    • pp.132-136
    • /
    • 2009
  • This study investigated the radial pulse waveform obtained by a medical pulsimeter sensor. A pulse-sensing part array consisting of multiple Hall devices was located over a skin-contacting part with a hard magnetic material. The periodic movement of the magnetic material of the skin-contacting part affected the magnetic field in the pulse-sensing part array and was detected by multiple Hall devices. The analysis of a radial pulse waveform that is measured noninvasively by detecting the changes of the magnetic field can be used to develop a new diagnostic algorithm of oriental medical apparatus.

Girdle 착용이 신체 제 기능에 미치는 영향에 관한 연구 (A Study on the Influence of Wearing-Girdle on the Various Physiological Function)

  • 박영득
    • 대한가정학회지
    • /
    • 제28권1호
    • /
    • pp.1-7
    • /
    • 1990
  • This study was carried out to investigate the influence of the various physiological function caused by girdle wearing. The four experimental methods used in this study are as follows. For example, the Reentgen photographing, body measurement by Sliding Gauge, mensurement of the electrocardiogram, measurement of the pulse and the blood pressure. The results of the investigation were as follows; 1. In the change of the various organs by Roentgen photographing, the diaphragm rised a little than normal position. The heart and stomach inclined to right side and the shape of stomach and duodenum are longer than the length of normal shape. Especially the phlorus of stomach was pressured strongly. 2. In the experimental change by the Sliding gauge and body measurement, the waist, hip and theigh girth of wearing-girdle reduced than at the no-girdle. The protruson of abdomen and hip section of wearing-girdle and the phenomenon of Hip-Up showed. 3. The difference by measurement of the electrocardiogram wasn't showed. The pulse of the wearing-girdle was increased slightly than the no-girdle. 4. The blood pressure of the wearing-girdle decreased slightly than the no-girdle.

  • PDF

Ultrasonic Measurement of Interfacial Layer Thickness of Sub-Quarter-Wavelength

  • Kim, No-Hyu;Lee, Sang-Soon
    • 비파괴검사학회지
    • /
    • 제23권6호
    • /
    • pp.577-582
    • /
    • 2003
  • This paper describes a new technique for thickness measurement of a very thin layer less than one-quarter of the wavelength of ultrasonic wave used in the ultrasonic pulse-echo measurements. The technique determines the thickness of a thin layer in a tapered medium from constructive interference of multiple reflection waves. The interference characteristics are derived and investigated in theoretical and experimental approaches. Modified total reflection wave g(t) defined as difference between total and first reflection waves increases in amplitude as the interfacial layer thickness decreases down to zero. A layer thickness less than one-tenth of the ultrasonic wavelength is measured using the maximum amplitude of g(t) with a good accuracy and sensitivity. The method also requires no inversion process to extract the thickness information from the waveforms of reflected waves, so that it makes possible to have the on-line thickness measurement of a thin layer such as a lubricating oil film in thrust bearings and journal bearings during manufacturing process.

Study on Image Retention in an AC Plasma Display Panel

  • Kim, Sang-Ho;Choi, Kyung-Cheol;Shin, Bhum-Jae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.259-262
    • /
    • 2005
  • Image retention is a kind of fatal shortcoming of the AC PDPs for realizing high-quality picture. In this work, the measurement method of image retention was proposed using temporal measurement of luminance, CIEXYZ tristimulus values, IR emission of reset pulse, and temperaturel. On the base of temporal measurement of luminance, CIEXYZ tristimulus value, and IR emission of reset pulse, the retention time of Ne+5%Xe gas-mixture discharge was about 2 hours after white window image. However, it was about 20 minute on the base of temporal measurement of temperature.

  • PDF

전자 밀도 분포 측정을 위한 극단 펄스 레플렉토메터리 (Ultrashort Pulse Reflectometry for the Measurement of Electron Density Profiles)

  • 노영수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권1호
    • /
    • pp.8-14
    • /
    • 2004
  • An O-mode Ultrashort Pulse Reflectometry (USPR) system has been designed and developed for the measurement of electron density profiles on the Sustained Spheromak Physics Experiment (SSPX) spheromak. In the original design of SSPX, peak densities were envisioned to be in the range of 0.5-3${\times}$10$^{14}$ cm$^{-3}$ . The total duration of formation and sustained discharges is typically ∼2 msec. Moreover, diagnostic access on SSPX is severely restricted. Such high density and short duration plasmas coupled with stringent diagnostic access are quite challenging for conventional reflectometer systems. In USPR, the SSPX diagnostic requirements have been successfully satisfied by employing up-converting mixers and monostatic horn/waveguide configuration. As a result, the USPR system has proven its applicability for the density measurement of a future fusion device. In the density profile measurements, the USPR system is capable of routinely generating density profiles with a temporal resolution of 57 $\mu$s. This paper presents details regarding the USPR fundamental principles, associated subsystems and laboratory tests as well as the experimental results obtained on SSPX

중의사의 맥진기 인식에 대한 통계 분석 연구 (The statistical analysis for cognizance on the Chinese oriental medical doctor of the pulse meter-analyzer)

  • 김경철;김종환;신우진;이해웅;박주연;홍상민;두승희;강희정;조영일
    • 대한한의진단학회지
    • /
    • 제13권2호
    • /
    • pp.88-116
    • /
    • 2009
  • Background : EBM (the evidence based medicine) is the direction of the development for oriental medicine. The pulse meter-analyzer is the important part to standardize the pulse diagnosis. When we set up the direction of the study on the pulse meter-analyzer, the awereness about the pulse meter and analyzer of the clinical oriental medical doctors as consumers is very important. Objectives : In order to prepare for the mutual study and the export strategy on the pulse meter-analyzer of Korea and China, the attitude of the study and the grasp of the awereness about the pulse meter-analyzer of the Chinese medical doctors are very important. Methods : We developed the several items as the important factor of the development of the pulse meter and analyzer. They were translated by chinese medical doctor. The investigation for demend was conducted during 3 months in Guangzhou City, Guangdong Province, China. The results of the investigation was done the statistical method of frequency analysis, Chi-squared test, correspondence analysis. Results : The most important differentiation of symptom is the symptom of JANG-BU(臟腑). The method of the utility in the pulse diagnosis is Chon-Gu (寸口) pulse diagnosis and the research on Chon-Kwan-Cheok(寸關尺) is the most important measurement factor. And the typical the old pulse is the little-fine weak pulse. The pulse meter-analyzer is most suitable to the diagnosis of the hypertension and the arteriosclerosis. Conclusion : The development of the pulse analyzer including the requests of Korean and Chinese medical doctors is very important. Specially the researches on the influence factors of the traditional diagnosis and the environment of the measurement are important for developing the pulse analyze.

  • PDF

초음파와 맥진기로 살펴본 인영맥의 세기와 경동맥의 상관 요인 연구 (Association of the Strength of Inyoung Pulse and Carotid Artery Using Ultrasonography and Pulse Diagnosis Device)

  • 송민선;이상영;최찬헌
    • 동의생리병리학회지
    • /
    • 제26권5호
    • /
    • pp.610-614
    • /
    • 2012
  • This study was done to identify correlates of carotid artery ultrasonography's measurement and Inyoung pulse in college students. We measured the amplitude of Inyoung pulse, Chongu pulse, ratio of Inyoung to Chongu and ratio of Chongu to Inyoung on 30 college students. Also, We measured the Distance, Diameter), RI(resistivity index), S/D(systolic, diastolic ratio), PI(pulsatility index), PSV(peak systolic velocity), EDV(End diastolic velocity), Vmean using carotid artery ultrasonography. The data was analyzed by Pearson's correlation coefficient using SAS program. The results were as follow. Results showed a positive correlation between Inyoung pulse and diameter by carotid artery. It showed a positive correlation between Inyoung pulse and S/D. Also, It showed a positive correlation between Inyoung pulse and PSV. As a result, the strength of Inyoung pulse related with the diameter of carotid artery and blood flow velocity.

맥 센서 어레이(array)의 실리콘(silicone) 코팅 두께에 따른 센서 간 간섭효과 (Interference Effects on the Thickness of a Pulse Pressure Sensor Array Coated with Silicone)

  • 전민호;전영주;김영민
    • 센서학회지
    • /
    • 제25권1호
    • /
    • pp.35-40
    • /
    • 2016
  • Pulse diagnosis is one of the representative diagnostic methods in Oriental medicine. In this study, a pulse pressure sensor array coated with silicone, which includes 6 piezo-resistive sensors and 1 thermistor, is fabricated for pulse measurement. It is necessary to coat the pulse sensor array with silicone to avoid the fracture or damage of pressure sensors when the sensor is in contact with the skin and a constant pressure is applied. However, the silicone coating on the pulse sensor array can cause signal interference among the sensors in the pulse sensor array. The interference number (IN), a calculation for expressing the degree of interference among channels, is changed according to the silicone thickness on the pulse sensor array. The IN is increased by a thick silicone coating, but the fabrication error, an important index for the mass production of the sensor array, is reduced by the thickness of the silicone coating. We propose that the thickness of the silicone on the pulse sensor array is an important consideration for the performance of the fabricated sensor and manufacturing repeatability.

펄스 튜브를 이용한 수중 전달 손실 측정에서 간극이 미치는 영향에 대한 고찰 (A Study on the Effect of a Gap in Measurement of Underwater Transmission Loss by Pulse Tube)

  • 서윤호;김상렬;김재승;변양헌;서영수
    • 한국음향학회지
    • /
    • 제34권3호
    • /
    • pp.192-199
    • /
    • 2015
  • 펄스 튜브를 이용하여 시편의 전달 손실 성능을 측정할 경우, 시편 설치를 위해 필연적으로 시편과 펄스 튜브 내벽 사이에 간극이 존재한다. 본 논문에서는 이와 같은 간극이 전달 손실 측정 결과에 미치는 영향에 대해 평가했다. 평면파에 대해 일정 폭 및 길이를 갖는 간극 전과 후 음압의 비를 구하여 전달 계수를 유도하고 측정 대상 시편의 전달 계수와 조합하여 간극이 포함된 시편의 전달 손실을 구했다. 이와 같은 해석 모델을 이론해가 존재하는 10 mm 두께의 스테인리스 스틸 시편에 적용하여 시험 결과와 비교함으로서 해석 모델의 적절성을 보였다. 마지막으로 해석 모델을 통하여 간극크기 및 시편 전달 손실 성능에 따라 전달 손실 측정에 미치는 영향을 분석했다.

The Real-Time Temporal and Spatial Diagnostics of Ultrashort High-Power Laser Pulses using an All-Reflective Single-Shot Autocorrelator

  • Kim, Ha-Na;Park, Seong Hee;Kim, Kyung Nam;Han, Byungheon;Shin, Jae Sung;Lee, Kitae;Cha, Yong-Ho;Jang, Kyu-Ha;Jeon, Min Yong;Miginsky, Sergei V.;Jeong, Young Uk;Vinokurov, Nikolay A.
    • Journal of the Optical Society of Korea
    • /
    • 제18권4호
    • /
    • pp.382-387
    • /
    • 2014
  • An all-reflective, simple noncollinear second harmonic (SH) autocorrelator is described for monitoring the shot-to-shot behavior of ultrashort high-power laser pulses. Two mirrors are used for the dispersion-free splitting of a pulse into two halves. One of the mirrors is able to adjust the delay time and angle between two halves of the laser pulse in a nonlinear crystal. We present the possibility of real-time measurement of the pulse duration, peak intensity (or energy), and the pointing jitters of a laser pulse, by analyzing the spatial profile of the SH autocorrelation signal measured by a CCD camera. The measurement of the shot-to-shot variation of those parameters will be important for the detailed characterization of laser accelerated electrons or protons.