• Title/Summary/Keyword: Pulse Load

검색결과 530건 처리시간 0.028초

저온 플라즈마의 펄스에너지 전송효율과 Wall Plug 소비전력과의 상호 특성에 관한 연구 (The Study on the Mutual Characteristics Between Transmitting Efficiency of Pulse Energy and Wall Plug Consumed Power of Non-Thermal Plasma)

  • 정종한;정현주;김휘영;정용호;송금영;김근용;김희제
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권10호
    • /
    • pp.506-510
    • /
    • 2002
  • In this paper, we study on the mutual characteristics between transmitting efficiency of pulse energy and wall plug consumed power of non-thermal Plasma for removing environmental pollutive gas of coal plant. To obtain high pulse energy of our system, we used MPC(magnetic pulse compressor) of power switch and tested their characteristics by adjusting electrode length of reactor and charging voltage in capacitor. As a result, we obtained consumed power of wall plug and a compressed pulse of voltage 110kV, rising time 500ns. Impedance of load on increasing electrode length was decreased, but electrical efficiency was increased. These results indicate we can control critical voltage of pulse corona and electrical efficiency of economic cost in power plant.

병렬 또는 직렬로 결합한 나선형 자장압축발전기의 출력특성 분석 (Output Characteristics of Parallel or Serially Connected Helical Magneto-Cumulative Generators)

  • 국정현;이흥호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권11호
    • /
    • pp.647-657
    • /
    • 2004
  • Helical magneto-cumulative generator(HMCG)s are very useful devices in suppling pulsed high current to inductance loads. To apply fast high voltage pulses to high impedance loads, high current outputs of HMCGs are required to be conditioned to higher voltages by using various pulse components such as opening/closing switches and pulse transformer. In this paper, stepping with the trends of requirements for ever-increasing energy in pulsed power applications coupling methods is investigated to obtain higher output energy by connecting several HMCGs in series or parallel way. The coil dimension of HMCGs used in series or parallel connections was 50 mm in diameter and 150 mm in length. The coil was fabricated by using enamel-coated copper wire of 1 mm in diameter. The highest energy amplification ratio and peak voltage of load were achieved from the serially connected four-barrel HMCG system. They were 68 and 34 kV, respectively, when the initial energy of 0.36 kJ was supplied into that system with the load of 0.4 μH. Within the tested range of inductance ratio, energy amplification ratio was found to be highly dependent on the inductance ratio of serial- and parallel-connected HMCG systems to load, which to be optimal around 500 was turned out. The experimental results showed that the output energy and voltage of load are controlled by connecting HMCGs in series or parallel.

119구급대원의 개인보호장비 착용이 혈압·맥박·호흡에 미치는 영향 (Effects of 119 Paramedics Wearing Personal Protective Equipment on Blood Pressure, Pulse, and Breathing)

  • 이승규;공하성
    • 대한안전경영과학회지
    • /
    • 제23권3호
    • /
    • pp.89-96
    • /
    • 2021
  • This study analyzed the physical changes in 119 paramedics transporting equipment at the emergency site and performing post-cardiopulmonary resuscitation through experiments. First, the average heart rate increased by about 25 times comparing CPR was performed without physical load and with personal protective equipment after moving equipment. In the third quartile, it increased to about 27 times. Second, when CPR was performed without physical load, and CPR was performed after moving the equipment with personal protective equipment, both the body temperature was raised and the rising body temperature was measured within normal body temperature. Third, the change in respiration rate increased by 7 times on average comparing CPR was performed without physical load and CPR was performed after moving the equipment while wearing personal protective equipment. In the third quartile, it increased to about 11 times. Finally, the change in blood pressure increased by 26.6 mmHg on average comparing CPR was performed without physical load and with wearing personal protective equipment after moving the equipment, and increased by 31.2 mmHg on average in the third quartile.

Experimental results of Stilting type Pulse Tube refrigerator with inertance tube

  • Hong, Yong-Ju;Park, Seong-Je;Kim, Hyo-Bong;Koh, Deuk-Yong;Park, Young-Don
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권1호
    • /
    • pp.118-122
    • /
    • 2003
  • Pulse tube refrigerator, which has no moving parts at its cold section, is attractive fer obtaining higher reliability, simpler construction and lower vibration than Stilting refrigerator or Gifford-McMahon refrigerator. Commonly used means to achieve optimum performance of Stilting type pulse tube refrigerator is an inertance tube. The use of inertance tube is a simple way to generate the phase shift needed to make pulse tube refrigerator operate as efficiently as Stilting refrigerator. In this study, the performance of the inertance pulse tube refrigerator (IPTR) was investigated experimentally. An in-line type IPTR consists of a linear compressor with two reciprocating pistons driven by linear motors, which makes pressure waves, a regenerator a pulse tube with the inertance tube, and a reservoir, The dynamic pressures (the compressor, pulse tube, reservior) and the temperature at the cold heat exchanger are measured to explore the dependence of the inertance tube on the performance of the IPTR. The experimental results show the dependency of cool-down characteristics, no-load temperature and amplitude of the pressures on the length and diameter of the inertance tube.

Forward형 고압펄스 전원장치를 적용한 오존발생 시스템 의 개발 (Development of Ozone Generating System Applying Forward Type High Voltage Pulse Power Supply)

  • 김동희;원재선;김경식;이광식;정도영;오승훈
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권7호
    • /
    • pp.335-342
    • /
    • 2003
  • This paper presents a forward type high voltage pulse power supply for high voltage small current, which can be designed as a simple circuit configuration and managed easily using Power-MOSFET in the view of commercialization. According to the switching frequency, coupling factor(k) and duty ratio(D), the Principle of basic operation and the characteristics of the proposed pulse power supply are estimated. Simulation results have demonstrated the feasibility of the proposed pulse power supply. Also experimental results are presented to verify theoretical discussion with a lamp type ozonizer as a load. For studying the application at the part of environment of water, When ozonizer gas reacts with a colon bacillus, the sterilization characteristics of a colon bacillus according to the ozone concentration and response time have been investigated. This proposed pulse power supply will be able to be practically used as a pulse power supply in various environment improvement facilities like sterilization of colon bacillus, deodorization, and Nox gas elimination.

PSII 펄스 시스템의 동적 플라즈마 부하 회로 모델 개발 (Development of a Circuit Model for the Dynamic Plasma Load in a PSII Pulse System)

  • 정경재;최재명;황휘동;김곤호;고광철;황용석
    • 한국진공학회지
    • /
    • 제15권3호
    • /
    • pp.246-258
    • /
    • 2006
  • 음의 고전압의 인가에 따라 반응하는 동적 플라즈마를 부하로 갖는 PSII(plasma source ion implantation) 펄스 시스템을 분석하기 위한 회로 모델을 개발하였다. 플라즈마 내에 삽입된 평판 전극 앞에서의 플라즈마 쉬스의 움직임은 동적 차일드-랑뮤어 쉬스 모델을 따르는 것으로 가정하였다. 표적 전극에 흐르는 전류는 전극에 인가되는 전압과 서로 영향을 주며 변하므로 동적 플라즈마 부하를 전압 의존 전류 원으로 표현하여 자기모순이 없는 회로 모델을 구현하였다. 회로 해석은 Pspice 프로그램을 이용하여 수행하였으며, 다양한 플라즈마 조건과 펄스인가 조건에서의 실험 결과와 비교하여 회로 모델의 타당성을 검증하였다.

전극의 용량성분을 이용한 공진이득 증폭형 유전가열장치에 관한 연구 (A study on a dielectric heating system for amplifying the resonant gain using the capacitance of electrodes)

  • 김신효;이창우;배한나;조대권
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권9호
    • /
    • pp.940-946
    • /
    • 2015
  • 본 논문에서는 300kHz 이상의 주파수를 사용하는 고전압펄스의 출력이득을 증폭시키는 방법에 대하여 고찰하였다. 종래의 파워스테이지의 전압을 상승시켜 펄스진폭(Pulse-amplitude)을 증폭하는 방식 대신에, 부하의 용량성분과 회로의 기생성분간의 공진을 이용하여 출력이득을 증폭하는 방식으로 연구가 진행되었다. 특히 브릿지형 대신에 Flyback Topology를 적용을 통하여 회로구성을 간소화하고, 출력펄스파형에 출력전극의 용량성분을 부여함에 따라 부하에 가해지는 출력전압의 이득을 증폭시킴으로써, 하드스위칭을 통한 출력회로 내에서의 과부하 및 발열에 따른 손상을 막을 수 있는 장점이 있다. 해당연구는 의료 및 산업용가열분야에 적용되는 유전가열 방식의 접촉형 가열기기의 공간적, 전기적 효율을 제고할 수 있는 한 방법을 제시한다.

Design Considerations for Auto-Connected Multi-Pulse Rectiviers for High Power AC Motor Drives

  • 이방섭
    • 전력전자학회논문지
    • /
    • 제4권5호
    • /
    • pp.413-422
    • /
    • 1999
  • Auto-connected multipulse(12/24pulse) rectifier schemes are cost effective methods for reducing line current hamonics in PWM drive systems. Employing these schemes to enhance utility power quality requires careful attention to several design considerations In particular, excursion of dc-link voltage at no load, effect of pre-existing voltage distortion, impedance mismatches, unequal diode drops on rectifier current sharing and performance, are fully analyzed, Several corrective measures to improve the performance of 12/24­pulse rectifier systems are also discussed. Finally, experimental results on a 460V, 60Hz 400kVA commercial ASD, retrofitted with 12/24pulse rectifier systems are discussed in detail.

  • PDF

Simulations for Square Pulse Generators

  • Jeong I. W.;Lee H. J.;Rim G. H.;Pavlov E. P.;Kim J. S.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 Proceedings ICPE 01 2001 International Conference on Power Electronics
    • /
    • pp.132-135
    • /
    • 2001
  • The design of square pulse generators using pulse forming lines (PFLs) made up of identical L and C, was reviewed in this study. 14 different types of PFLs were analyzed utilizing PSpice simulation results. These PFLs were characterized with respect to their distinct features: the number of forming lines (single or double), the circuit relationship between PFL and load (parallel or series), the types of energy storage (voltage source, current source or a combination of both). The characteristic impedances, output parameters such as pulse width, voltage and current magnitudes, and powers were derived for each scheme. The merits and demerits of the output parameters were also included.

  • PDF

단일 스위치 3상 ZCS 강압형 정류기의 펄스 주파수 제어 (A Pulse Frequency Control of Single-switch Three-phase ZCS Buck Rectifiers)

  • 송중호;김용덕;이동윤;최익;최주엽;유지윤
    • 전력전자학회논문지
    • /
    • 제4권1호
    • /
    • pp.82-90
    • /
    • 1999
  • 본 논문은 단일 스위치 3상 ZCS 강압형 정류기의 펄스주파수 제어기법을 다루고 있다. 제안하는 펄스주파수 제어방법은 거의 정현적인 입력전류를 흐르게 하여 3상 강압형 정류기의 성능을 보여준다. 제안하는 제어구조의 유용성을 검증해 주는 시뮬레이션과 실험 결과는 단일 스위치 3상 ZCS 강압형 정류기의 고역율, 입력전류의 낮은 THD, 부하 변동에 대한 전압의 응답특성들이 뛰어남을 보여준다.