• Title/Summary/Keyword: Pulse Load

Search Result 530, Processing Time 0.035 seconds

Energy Model Based Direct Torque Control of Induction Motor Using IP Controllers

  • Mannan, Mohammad Abdul;Murata, Toshiaki;Tamura, Junji
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.4
    • /
    • pp.405-411
    • /
    • 2012
  • This paper deals with direct torque control of an induction motor (IM) with constant switching frequency. The desired torque is obtained from the speed controller which is designed using the IP controller. Decoupling control of torque and flux is developed based on the energy model of IM using the IP controller strategies. The desired d-axis and q-axis stator voltage components are obtained from the designed controller, which decouples torque and flux. The constant switching frequency can be applied using space-vector pulse width modulation, since the desired stator voltage can be known from the decoupling torque and flux controllers. In order to achieve stable operation of the proposed IP controllers, the gains of the controllers are chosen by setting the poles in negative (left) half of s-plane and by choosing the rising time for the response of the step function. The proposed controller was verified in simulations using Matlab/Simulink and results have proven excellent performance. It was found that the proposed IP controllers can provide excellent performance to track the desired torque and speed and to reject the disturbance of load.

Stabilization Analysis of Piezo-electric Converter for PFM and PWM Control (압전 변압기의 제어 방식에 따른 모델링 및 안정화분석)

  • Yun, Seok-Teak;Park, Seong-Woo;Won, Young-Jin;Lee, Jin-Ho;Kim, Jin-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.401-401
    • /
    • 2009
  • Recently, demands for the development of compact, lightweight power supplies with higher power density and higher efficiency have been increased. Since Piezoelectric Transformer (PT) was emerged in device and material industry, it has been suggested as a viable alternative to the magnetic transformer in some applications. PT has some advantages such as low profile and mechanical energy transfer with little electromagnetic interface (EMI). Also, PT can provide high voltage stepping ratio with good isolation and requires no copper windings saving copper usage especially for large voltage conversion differences. Conventional control of PT converter has mainly two-way. One is the pulse frequency modulation (PFM) control method and the other is the pulse width modulation (PWM) control with frequency fixed method. It is known that the maximum PT efficiency can be obtained when it operates near the resonant frequency of the PT. And, also PT's resonant frequency moves according to the load condition. Therefore, selection of PT converter control method is very difficult. This paper analyzes general piezo-electric converter modeling and proposes a guide-line to selection of control method and stabilization control.

  • PDF

Study on High Voltage Switch Using IGBT (IGBT를 사용한 고전압 스위치에 관한 연구)

  • Park, S.S.;Kim, S.C.;Cho, M.H.;NamKung, W.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.556-558
    • /
    • 1996
  • PLS 2-GeV linac has 11 sets of high power klystron-modulator system as a main RF source for the beam acceleration. The modulators can provide 200-MW peak pulsed power(400-kV, 500-A) with a pulse width of $7.5{\mu}s$(ESW), a maximum pulse repetition rate of 120-Hz at the full power level. The DC power supply provides a 25-kV, 7-Adc and the charging system consists of a charging inductor, charging capacitor, and the diode for reverse current protection. The charged PFN voltage by a LC resonant charging method has two times of the DC high voltage and the pulsed power is delivered to the load by a thyratron switch. To reduced the press of high voltage lit thyratron switch, the command charging is the best method. In this article, the high voltage switch for the command charging method is tested to the start work and the system is presented with the experiment results of the trigger and operational characteristics.

  • PDF

A Study on the Magnetic Circuit Design and Control Method of 2-Phase 8-Pole PM Type Linear Pulse Motor (2상(相)8극영구자석형(極永久磁石形) LPM의 자기회로설계(磁氣回路設計)와 제어방식(制御方式)에 관한 연구(硏究))

  • Kim, Il-Jung;Lee, Eun-Woong;Lee, Min-Myeong;Lee, Myeong-Il
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.47-50
    • /
    • 1991
  • LPM(Linear Pulse Motor) provide direct and precise position control of bidirectional linear motion. LPM is not subject to the same linear velocity and acceleration limitations inherent in systems converting rotary to linear motion such as lead screws, rack and pinion, belt and pulley drives. With LPM, all the thrust force generated by the motor is efficiently applied directly to the load. And speed, distance, and acceleration are easily programmed in a highly repeatable fashion. Potential industrial and application fields of LPM include PCB assembly, industrial sewing machines, automatic inspection, coil winder, medical uses, conveyer system, laser cut and trim systems, semiconductor wafer processing, OA instruments etc. This paper describes various design parameter of LPM such as magnetic ciucuit construction methods, phase number and tooth number per pole, permanent magnet and coil mmf, tooth geometries. And to solve the problems of existing control methods, in this paper, a new control method of the LPM is proposed throughout modern control theory.

  • PDF

A Study on the Detection of Indication of Accident in Electric Equipments with Incandescent Lamps Using Current Monitor (전류 모니터를 이용한 백열등 부하 전기설비에서 사고 징후 검출에 관한 연구)

  • Jee, Seung-Wook;Ok, Kyung-Gea;Kim, Shi-Kuk;Lee, Chun-Ha;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.1
    • /
    • pp.109-115
    • /
    • 2009
  • This paper describes an early detection for indication of electric accident using current waveform which is measured in electric equipments consisted incandescent lamps. At first, it analyzes characteristics of current monitor in resistive electric circuit. In second, the electric equipment is consisted of incandescent lamps. And the electric accident is simulation of tracking according to KS C IEC(Korea Standard C International Electrostatic Commission) 60112 at some part of the electric equipment. The indication of the electrical accident is detected to analyzing current waveform measured by current monitor. As the tracking breakdown, electric accident, processes, as current pulse is bigger and ratio of appearance also is increased irrespective of amount of load.

Operation modes and Protection of VS(Vertical Stabilization) Converter for International Thermonuclear Experimental Reactor (국제 핵융합실험로용 VS(Vertical Stabilization) 컨버터의 운전모드 및 보호동작)

  • Jo, Hyunsik;Jo, Jongmin;Oh, Jong-Seok;Suh, Jae-Hak;Cha, Hanju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.2
    • /
    • pp.130-136
    • /
    • 2015
  • This study describes the structure and operation modes of vertical stabilization (VS) converter for international thermonuclear experimental reactor (ITER) and proposes a protection method. ITER VS converter supplies voltage (${\pm}1000V$)/current (${\pm}22.5kA$) to superconducting magnets for plasma current vertical stabilization. A four-quadrant operation must be achieved without zero-current discontinuous section. The operation mode of the VS converter is separated in 12-pulse mode, 6-pulse mode and circulation current mode according to the magnitude of the load current. Protection measures, such as bypass and discharge, are proposed for abnormal conditions, such as over current, over voltage, short circuit, and voltage sag. VS converter output voltage is controlled to satisfy voltage response time within 20 msec. Bypass operation is completed within 60 msec and discharge operation is performed successfully. The feasibility of the proposed control algorithm and protection measure is verified by assembling a real controller and implementing a power system including the VS converter in RTDS for a hardware-in-loop (HIL) facility.

Analysis, Design, and Implementation of a Zero-Voltage-Transition Interleaved Boost Converter

  • Ting, Naim Suleyman;Sahin, Yakup;Aksoy, Ismail
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.41-55
    • /
    • 2017
  • This study proposes a novel zero voltage transition (ZVT) pulse width modulation (PWM) DC-DC interleaved boost converter with an active snubber cell. All the semiconductor devices in the converter turn on and off with soft switching to reduce the switching power losses and improve the overall efficiency. Through the interleaved approach, the current stresses of the main devices and the ripple of the output voltage and input current are reduced. The main switches turn on with ZVT and turn off with zero voltage switching (ZVS). The auxiliary switch turns on with zero current switching (ZCS) and turns off with ZVS. In addition, the snubber cell does not create additional current or voltage stress on the main switches and main diodes. The proposed converter can smoothly achieve soft switching characteristics even under light load conditions. The theoretical analysis and operating stages of the proposed converter are made for the D > 50% and D < 50% modes. Finally, a prototype of the proposed converter is implemented, and the experimental results are given in detail for 500 W and 50 kHz. The overall efficiency of the proposed converter reached 95.5% at nominal output power.

Characteristics of Capacitor Bank Composed of Eight Paralleled Modules (300kJ${\times}$B 모듈로 구성된 커패시터 뱅크의 특성 분석)

  • Sung, G.Y.;Jung, J.W.;Choi, Y.H.;Kim, J.S.;Chu, J.H.;Lee, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1600-1602
    • /
    • 2001
  • A pulsed power supply of 2.4MJ capacitor bank has been developed to make investigation into electric gun technology. It is made up of eight paralleled 300kJ modules, and can supply various shape of high current pulse by changing charging voltage, inductance, capacitance, and firing time of each module. The 300kJ module has been designed and fabricated for the maximum operating voltage of 22kV, peak current of 150kA, and pulse duration of 1msec. The experiments of the modules were done, and the equivalent circuit of the module was determined. The characteristics of the module were analyzed more deeply through the circuit simulation. The experiments of the paralleled modules with inductance of 20 $\mu$H and load resistance of 100 m$\Omega$ were performed, where the modules were discharged simultaneously and/or sequentially. The results of the experiments were analyzed. The 2.4MJ capacitor bank is currently used as the pulsed power supply for the ETCG (Electro Thermal Chemical Gun) research.

  • PDF

Rapid-Charging Solution for 18650 Cylindrical Lithium-Ion Battery Packs for Forklifts

  • Kim, Dong-Rak;Kang, Jin-Wook;Eom, Tae-Ho;Kim, Jun-Mo;Lee, Jeong;Won, Chung-Yuen
    • Journal of Electrochemical Science and Technology
    • /
    • v.9 no.3
    • /
    • pp.184-194
    • /
    • 2018
  • In this paper, we propose a rapid-charging system for the lithium-ion battery (LIB) packs used in electric forklifts. The battery offers three benefits: reduced charge time, prolonged battery life, and increased charging efficiency. A rapid-charging algorithm and DC/DC converter topology are proposed to achieve these benefits. This algorithm is developed using an electrochemical model, which controls the maximum charging current limit depending on the cell voltage and temperature. The experimental use of a selected 18650 LIB cell verified the prolongation of battery life on use of the algorithm. The proposed converter offers the same topological merits as a conventional resonant converter but solves the light-load regulation problem of conventional resonant converters by adopting pulse-width modulation. A 6.6-kW converter and charging algorithm were used with a forklift battery pack to verify this method's operational principles and advantages.

The Characteristic Comparison of Various PWM Strategies for Generating Pulse Signal of Voltage Source Inverter (전압원 인버어터의 펄스신호를 발생시키기 위한 PWM 방식의 특성 비교)

  • 정동화;이윤종;오원석
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.15 no.5
    • /
    • pp.384-398
    • /
    • 1990
  • This paper compares and shows the characteristics of various PWM strategies used to generate pulse signals of voltage source inverter. We designed the inverter using PTR and constituted the variable speed drive (VSD) system. For each PWM strategy, acoustic noise level, line-to-line voltage and current waveform, and current harmonic spectrum are measured with respect to the VSD of induction motor. The Suboptimal PWM strategy showed the similar harmonic effects to those of the Optimal PWM strategy. In addition, the microprocessor application was available to the former. The TP PWM strategy was excellent in that it could reduce the CPU load and increase the output voltage since the strategy could control only two phase of the three.

  • PDF